• Title/Summary/Keyword: Patient Prescription

Search Result 423, Processing Time 0.024 seconds

Analysis of Photon Characteristics and Absorbed Dose with Cone Beam Computed Tomography (CBCT) using Monte Carlo Method (몬테칼로 기법을 이용한 CBCT의 광자선 특성 및 선량 분석)

  • Kim, Jong-Bo;Kim, Jung-Hoon;Park, Eun-Tae
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.161-169
    • /
    • 2017
  • The cone beam computed tomography(CBCT) which can acquire 3-dimensions images is widely used for confirmation of patient position before radiation therapy. In this study, through the simulation using the Monte Carlo technique, we will analyze the exposure dose by cone beam computed tomography and present the standardized data. For the experiment, MCNPX(ver. 2.5.0) was used and the photon beam spectrum was analyzed after Cone beam was simulated. As a result of analyzing the photon beam spectrum, the average energy ranged from 25.7 to 37.6 keV at the tube voltage of 80 ~ 120 kVp and the characteristic X-ray energy was 9, 60, 68 and 70 keV. As a result of using the water phantom, the percentage depth dose was measured, and the maximum dose appeared on the surface and decreased with depth. The absorbed dose also decreased as the depth increased. The absorbed dose of the whole phantom was 9.7 ~ 18.7 mGy. This is a dose which accounts for 0.2% of about 10 Gy, which is generally used for radiation therapy per week, which is not expected to have a significant effect on the treatment effect. However, it should not be overlooked even if it is small compared with prescription dose.

Development of Tomotherapy couch device capable of yaw-directional correction (Yaw방향의 보정이 가능한 Tomotherapy couch device의 개발)

  • Chae, Moon Ki;Kwon, Dong Yeol;Sun, Jong Lyool;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.139-151
    • /
    • 2018
  • Objectives : A self-made "Tomotherapy couch device" capable of correcting the Yaw direction was fabricated and evaluated for its usefulness. Materials and Methods : "Tomotherapy couch device" capable of correcting the Yaw direction is made of rigid fibreboard with a flexural strength of $200kg/cm^2$. CBCT Image from Novalis Tx and Iso-Align Phantom from MED-TEC were used to evaluate the physical accuracy. The treatment plan was designed using Accuray $Precision^{TM}$ and In House Head and Phantom. Accuray $PrecisionART^{TM}$ and $Precision^{TM}$ was used to evaluate dose. Results : Evaluation results, the self-fabricated device accurately corrected the setup error, Target dose was within 95 %~107 % of all. In order to directly evaluate the OAR dose according to the Yaw change, the absolute dose was measured. As a result, when the error in the Yaw direction was $3^{\circ}$, the specific OAR showed a maximum difference of 18.4 %. Conclusion : "Tomotherapy couch device" capable of correcting the Yaw direction can be manufactured at a lower cost compared to the effect, and it can prevent the patient's MVCT image dose for re-imaging. Accurate radiation therapy without errors can be performed.

  • PDF

The Clinical Features and Risk Factors of Seizure After Doxylamine Intoxication (독실라민 중독시 발생할 수 있는 발작의 특성과 위험인자)

  • Song, Beom-Soo;Lee, Ki-Man;Kim, Sun-Wook;You, Je-Sung;Chung, Tae-Nyung;Park, Yoo-Seok;Jung, Sung-Phil;Goo, Hong-Du;Park, In-Cheol
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.8 no.2
    • /
    • pp.88-96
    • /
    • 2010
  • Purpose: Doxylamine is antihistamine drug that is used as a hypnotic. It is also used for suicidal attempts because it can be easily purchased at the pharmacy without a prescription. There were many articles about the complications after doxylamine intoxication such as a rhabdomyolysis, but only a few articles have reported on seizure. We reviewed the cases of doxylamine intoxication with seizure that were treated in the emergency department. Methods: We reviewed the medical records of the patients who were over 15 years old and who were intoxicated by doxylamine at 3 emergency medical centers from January 2006 to June 2010. We reviewed the patients' age, gender, the dose of doxylamine ingested, if gastrointestinal decontamination was done, the time from intoxication to hospital arrival, the seizure history, treatment of seizure, the electroencephalography (EEG) results, the brain computed tomography (CT) results and the blood test results. Results: There were 168 patients who were intoxicated by doxylamine during the study period. Twelve patients had a seizure episode. The differences between the patients who developed seizure and the patients who did not were the dose and the serum levels of sodium and creatinine. The only clinically meaningful difference was the amount of doxylamine. The amount of doxylamine ingested (>29 mg/kg) predicted the development of seizure with a sensitivity of 75% and a specificity of 92% on the ROC curve. One patient among the seizure patients expired in the emergency department. Conclusion: In case of doxylamine intoxicated patients, there is close relationship between seizure and ingested amount, so close observation needs to be done for the patients who ingest too much because doxylamine can cause death. Further prospective studies are needed for doxylamine intoxicated patients with a seizure episode.

  • PDF

The Necessity of Redefining the Radiological Technologist Independent Law (방사선사법 제정의 필요성)

  • Lim, Woo-Taek;Lim, Cheong-Hwan;Joo, Young-Cheol;Hong, Dong-Hee;Jung, Hong-Ryang;Jung, Young-Jin;Choi, Ji-Won;Yoon, Yong-Su;Kim, Eun-Hye;Yoo, Se-Jong;Park, Myeong-Hwan;Yang, Oh-Nam;Jeong, Bong-Jae
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.545-554
    • /
    • 2021
  • According to the changes of the medical environment of the times, it is necessary to discuss the issues of the doctor's medical guidance and to conduct continuous research so that alternatives can be prepared systematically. Furthermore, in order to enhance the professionalism of radiological technologists and to develop the medical technician system, the new Radiological Technologist Independent Act has been established, which contains the overall contents of the scope of work, professional qualifications, and specialized education of radiological technologists, and provides quality medical services to patients through professional procedures and treatment. In order to increase the level of medical care, the purpose, definition, mission, role, and scope of work specified in the Medical Act, Medical Service Technologists, etc. Act, the Enforcement Decree, and the Enforcement Rules were variously analyzed and new directions were presented. First, the definition of a medical technician should use a generic term so that the factors of conflict and prejudice could be resolved. Second, change the doctor's guide to doctor's prescription; and then legislate the authority to sign and write medical records after examination by radiological technologists, thereby prohibiting unlicensed technicians that seriously endanger patient safety. Third, an accurate definition of radiological technologists' roles should be established; not only selection and management of radiological technologists' work but also procedures and treatment for each radiology field should be specified to suit the current medical system. Fourth, a professional radiological technologists' qualification system and a specialized education system should be established in order to secure human resources that could provide patients trust in procedures and treatment based on professional knowledge and experience in the field of radiology. Fifth, the Education and Evaluation Institute should be operated in Korea education system to educate the professional knowledge and competency for students. In addition, it is necessary to in-depth analysis of foreign cases could be applied to the medical system and education system in Korea; it could strive to nurture systematic human resources.

Issue Analysis on the Deregulation of Telemedicine in the Digital Convergence Era (디지털 융복합시대에 원격의료 규제 완화에 관한 쟁점 분석)

  • Kim, Jin-Suk;Oh, Su-Hyun
    • Journal of Digital Convergence
    • /
    • v.18 no.12
    • /
    • pp.445-457
    • /
    • 2020
  • The purpose of this study is to analyze various issues that may arise from the recent deregulation of telemedicine implemented by the government, propose initiative preparations for the implementation of telemedicine policies, and suggest implications for the basic conditions and direction of the deregulation of telemedicine. Recently, deregulation policy cases in telemedicine include that designation of a special zone for regulatory freedom in Gangwon Province, allowing physician-patient telemedicine and telephone counseling and prescription cases in the COVID-19 crisis. There are four main issues that could arise with the deregulation of telemedicine: safety, effectiveness, differences in access to health care and the economic industry, and legal responsibility. As a initiative preparation, this study proposed a pilot project for telemedicine and enhanced support for face-to-face care complementary tools, vitalizing remote co-operation, policy model that do not disrupt the medical delivery system, and legal maintenance. In conclusion, as a suggestion of basic premise and direction in the implementation of telemedicine deregulation, the implementation of initiative measures to address issues concerning telemedicine, the review and regulation of conditions to be considered in the implementation of telemedicine, and the establishment of a close communication and cooperative sturcture with medical providers.

A Study on the Practice Model for Practical Education for Health and Medical Information Management (보건의료정보관리 실습교육을 위한 실습모델 연구)

  • Choi, Joon-Young
    • Journal of the Health Care and Life Science
    • /
    • v.8 no.2
    • /
    • pp.83-93
    • /
    • 2020
  • In this study, a practical model for health information management education using the EMR education system at universities for nurturing health care information managers was studied. Currently, there is no practical training course for health care information management in the standards for evaluation and certification of health care information management education introduced to strengthen the job competency of health care information managers. Accordingly, the program was constructed so that the practice program suggested as an educational environment in the Health and Medical Information Management Education Evaluation and Certification Manual can be practiced in the EMR education system. In addition, a practical model that can be performed according to the on-site practice guidelines for health and medical information management for each program was studied. Using the health care information management education EMR system, master data management, patient registration, doctor prescription, medical cost calculation, health insurance claim management, form management, discharge registration, cancer registration, unrecorded management, health care data management, health care statistics, A practice model was studied so that practice on information protection/security management can be performed. It will be possible to play a role as a health care information management expert by raising the quality level of health care information management education through systematic and standardized health care information management practice courses at universities. Accordingly, it is necessary to cultivate health care information management experts who develop and manage medical services based on medical data analysis through practical training of health care information managers.

Legal regulations on telemedicine and their problems (원격의료에 대한 법적 규제와 그 문제점)

  • Hyun, Doo-youn
    • The Korean Society of Law and Medicine
    • /
    • v.23 no.1
    • /
    • pp.3-33
    • /
    • 2022
  • In relation to telemedicine in Korea's medical law, there are Articles 17, 17-2, and 34 of the Medical Act. Since 'direct examination' in Articles 17 and 17-2 of the Medical Act can be interpreted as 'self-examination' rather than 'face-to-face examination', it is difficult to see the above regulation as a regulation prohibiting telemedicine. Prohibiting telemedicine only with the concept of medical examination or the 'principle of face-to-face treatment' is against the principle of "nulla poena sine lege"(the principle of legality). However, in order to qualify as 'examination', it must be faithful enough to replace face-to-face examination, so issuing a medical certificate or prescription after a poor examination over the phone is considered a violation of the Medical Act. In that respect, the above regulation can be said to be a regulation that indirectly limits telemedicine. On the other hand, most lawyers interpret that telemedicine between medical personnel and patients is completely prohibited based on Article 34, and the Supreme Court recently ruled that such telemedicine is not permitted even if there is a patient's request. However, this interpretation is not only far from the legislative intention at the time when telemedicine regulations were introduced into the Medical Act of 2002, but also does not match the needs of reality or the legislative trend of foreign countries. The reason is that telemedicine regulations are erroneously legislated. The premise of the legislation is wrong, and there are considerable problems in the form and content of the legislation. As a result, contrary to the original legislative intent, telemedicine was completely banned. In foreign countries, it is difficult to find cases where telemedicine is completely banned and criminal punishment is imposed for it. In order to fundamentally solve the problem of telemedicine, Article 34 of the Medical Act needs to be deleted.

A Case Series of Polycystic Ovary Syndrome with Improved Hyperandrogenism Treated with Korean Medicine (한방 치료로 고안드로겐혈증을 개선한 다낭성 난소 증후군 연속증례연구)

  • Shin, Haegue;Bae, Ji-Yong;Ji, Young-Geun;Ahn, Hae In;Yoon, Youngheum;Kim, Namkwen
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.34 no.3
    • /
    • pp.175-191
    • /
    • 2021
  • Objectives: This study aims to analyze the medical record of eight cases of polycystic ovary syndrome (PCOS) in a local Korean medicine clinic, in order to provide evidence on Korean medicine treatment of PCOS and to suggest the direction of future studies. Methods: The medical records of eight cases diagnosed with PCOS based on 2003 Rotterdam Criteria and whose total testosterone level was 0.53 ng/ml and over were retrospectively analyzed. The primary outcome was total testosterone level, and the secondary outcomes included luteinizing hormone (LH) and follicle stimulating hormone (FSH) levels, LH/FSH ratio, weight, last mentrual period (LMP), numerical rating scale (NRS) score of dysmenorrhea, and other associated symptoms pre- and post-treatment. Korean medicine treatment consists of the complex herbal prescription consisting of Yukmijihwang-tang, Baekho-tang, Daesiho-tang, and Gyejibokryeong-hwan, modified according to symptoms; acupuncture and electroacupuncture on 中脘 (CV12), 下脘 (CV10), 關元 (CV4), 石門 (CV5), 合谷 (LI4), 太衝 (LR3), 三陰交 (SP6), and 懸鍾 (GB39); and indirect moxibustion on 神闕 (CV8). Results: The average total testosterone level lowered statistically significantly after the treatment. The average FSH and LH levels lowered with insignificance, while the average LH/FSH ratio and weight lowered statistically significantly. During the treatment period of three to six months, every patient had the menstrual cycle shortened except for one case; and two cases with infertility problem succeeded in being pregnant. There was no adverse event. Conclusions: The Korean medicine treatment was found effective in treating PCOS, especially regarding hyperandrogenism, amenorrhea or oligomenorrhea, and infertility.

Evaluation of Dose Variation according to Air Gap in Thermoplastic Immobilization Device in Carbon Ion (탄소입자 치료 시 열가소성 고정기구의 공기층에 따른 선량 변화 평가)

  • Ye-jin Na;Ji-Won Jang;Se-Wuk Jang;Hyo-Kuk Park;Sang-Kyu Lee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.33-39
    • /
    • 2023
  • Purpose: The purpose of this study is to find out the dose variation according to thickness of the air gap between the patient's body surface and immobilization device in the treatment plan. Materials and Methods : Four conditions were created by adjusting the air gap thickness using 5 mm bolus, ranging from 0 mm to 3 mm bolus. Immobilization was placed on top in each case. And computed tomography was used to acquire images. The treatment plan that 430 cGy (Relative Biological Effectiveness,RBE) is irradiated 6 times and the dose of 2580 cGy (RBE) is delivered to 95% of Clinical Target Volume (CTV). The dose on CTV was evaluated by Full Width Half Maximum (FWHM) of the lateral dose profile and skin dose was evaluated by Dose Volume Histogram (DVH). Result: Results showed that the FWHM values of the lateral dose profile of CTV were 4.89, 4.86, 5.10, and 5.10 cm. The differences in average values at the on the four conditions were 3.25±1.7 cGy (RBE) among D95% and 1193.5±10.2 cGy (RBE) among D95% respectively. The average skin volume at 1% of the prescription dose was 83.22±4.8%, with no significant differences in both CTV and skin. Conclusion: When creating a solid-type immobilization device for carbon particle therapy, a slight air gap is recommended to ensure that it does not extend beyond the dose application range of the CTV.

  • PDF

A Dosimetric Evaluation of Large Pendulous Breast Irradiation in Prone Position (Large Pendulous Breast 환자의 방사선 치료에 있어서 엎드린 자세의 유용성 평가)

  • Hong, Chae-Seon;Ju, Sang-Gyu;Park, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.37-43
    • /
    • 2008
  • Purpose: To evaluate dosimetry results of three different techniques for whole breast irradiation after conservative surgery of large pendulous breast patient. Materials and Methods: Planning computed tomography (CT) scans for three techniques were performed on a GE Hi-speed advantage CT scanner in the supine (SP), supine with breast supporting Device (SD) and prone position on a custom prone mattress (PP). Computed tomography images were acquired at 5 mm thickness. The clinical target volumes (CTV), ipsilateral lung and heart were delineated to evaluate the dose statistic, and all techniques were planned with the tangential photon beams (Pinnacle$^3$, Philips Medical System, USA). The prescribed dose was 50 Gy delivered in 25 fractions. To evaluate the dose coverage for CTV, we analysed percent volume of CTV receiving minimum of 95%, 100%, 105%, and 110% of prescription dose ($V_{95}$, $V_{100}$, $V_{105}$, and $V_{110}$) and minimal dose covering 95% ($D_{95}$) of CTV. The dosimetric comparison for heart and ipsilateral lung was analysed using the minimal dose covering 5% of each organs ($D_5$) and the volume that received >18 Gy for the heart and >20 Gy for the ipsilateral lung. Results: Target volume coverage ($V_{95}$ and $V_{100}$) was not significantly different for all technique. The V105 was lower for PP (1.2% vs. 4.4% for SP, 11.1% for SD). Minimal dose covering 95% ($D_{95}$) of target was 47.5 Gy, 47.7 Gy and 48 Gy for SP, SD and PP. The volume of ipsilateral lung received >20 Gy was 21.7%, 11.6% and 4.9% for SP, SD and PP. The volume of heart received >18 Gy was 17.0%, 16.1% and 9.8% for SP, SD and PP. Conclusion: Prone positioning of patient for large pendulous breast irradiation enables improving dose uniformity with minimal heart and lung doses.

  • PDF