• Title/Summary/Keyword: Patient Outcome Assessment

Search Result 212, Processing Time 0.018 seconds

Treat-to-Target Strategy for Asian Patients with Early Rheumatoid Arthritis: Result of a Multicenter Trial in Korea

  • Song, Jason Jungsik;Song, Yeong Wook;Bae, Sang Cheol;Cha, Hoon-Suk;Choe, Jung-Yoon;Choi, Sung Jae;Kim, Hyun Ah;Kim, Jinseok;Kim, Sung-Soo;Lee, Choong-Ki;Lee, Jisoo;Lee, Sang-Heon;Lee, Shin-Seok;Lee, Soo-Kon;Lee, Sung Won;Park, Sung-Hwan;Park, Won;Shim, Seung Cheol;Suh, Chang-Hee;Yoo, Bin;Yoo, Dae-Hyun;Yoo, Wan-Hee
    • Journal of Korean Medical Science
    • /
    • v.33 no.52
    • /
    • pp.346.1-346.11
    • /
    • 2018
  • Background: To evaluate the therapeutic benefits of the treat-to-target (T2T) strategy for Asian patients with early rheumatoid arthritis (RA) in Korea. Methods: In a 1-year, multicenter, open-label strategy trial, 346 patients with early RA were recruited from 20 institutions across Korea and stratified into 2 groups, depending on whether they were recruited by rheumatologists who have adopted the T2T strategy (T2T group) or by rheumatologists who provided usual care (non-T2T group). Data regarding demographics, rheumatoid factor titer, anti-cyclic citrullinated peptide antibody titer, disease activity score of 28 joints (DAS28), and Korean Health Assessment Questionnaire (KHAQ) score were obtained at baseline and after 1 year of treatment. In the T2T group, the prescription for disease-modifying antirheumatic drugs was tailored to the predefined treatment target in each patient, namely remission (DAS28 < 2.6) or low disease activity (LDA) ($2.6{\leq}DAS28$ < 3.2). Results: Data were available for 163 T2T patients and 162 non-T2T patients. At the end of the study period, clinical outcomes were better in the T2T group than in the non-T2T group (LDA or remission, 59.5% vs. 35.8%; P < 0.001; remission, 43.6% vs. 19.8%; P < 0.001). Compared with non-T2T, T2T was also associated with higher rate of good European League Against Rheumatism response (63.0% vs. 39.8%; P < 0.001), improved KHAQ scores (-0.38 vs. -0.13; P = 0.008), and higher frequency of follow-up visits (5.0 vs. 2.0 visits/year; P < 0.001). Conclusion: In Asian patients with early RA, T2T improves disease activity and physical function. Setting a pre-defined treatment target in terms of DAS28 is recommended.

Early Clinical Experience in Aortic Valve Replacement Using On-X$^{circledR}$Prosthetic Heart Valve (On-X$^{circledR}$ 기계판막을 이용한 대동맥판 치환술의 조기 임상 경험)

  • 안병희;전준경;류상완;최용선;김병표;홍성범;박종춘;김상형
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.651-658
    • /
    • 2003
  • Since the first implanted in September 1997, the use of On-X prosthetic heart valve has been increasing around in the world. This study was designed to assess the feasibility, safety, and the postoperative hemodynamics with this new valve in clinical setting. Material and Method: The current study was carried out on 52 patients undergoing aortic valve replacement with this prosthesis between April 1999 to August 2002 at Chonnam National University Hospital to evaluate the surgical results. 52% of the patients were male and the average age at implant was 50$\pm$13 years. The study followed the guidelines of the AATS/STS. Preoperatively, 32(61.5%) patients were in NYHA functional class III or IV and 2 patients had previous aortic valve surgery. Concomitant cardiac surgery was performed in 71.1%. The implanted valve sizes were 19 mm in 13 patients, 21 mm in 26, 23 mm in 10 and 25 mm in 3, respectively. Mean follow-up was 16.6$\pm$10.5 months (1∼39 months). Echocardiographic assessment was performed pre- and immediate postoperatively, as well as 3, 6, 12 months after surgery, evaluating pressure loss and regression of left ventricular hypertrophy. Result: Mean cardiopulmonary bypass time was 191$\pm$94.7 minutes with an aortic cross-clamp time of 142$\pm$51.7 minutes. There was no early and late mortality, Freedom from adverse events at 1 year in the study were as follows: thromboembolism, 95.6$\pm$6%; bleeding events, 90.2$\pm$4%; paravalvular leakage 92.3$\pm$4%; and overall valve-related morbidity at 1 year was 76.6$\pm$3%. There were no cases of valve thrombosis, prosthetic valve endocarditis and structural or non-structural failure. Left ventricular function at 12 months after surgery (EF=62.7$\pm$9.8%) revealed a statistically significant improvement compared to preoperative investigation (EF=55.8$\pm$15.9%, p=0.006). Left ventricular mass index was 247.3$\pm$122.3 g/$m^2$ on preoperative echocardiographic study, but regressed to 155.5$\pm$58.2 g/$m^2$ at postoperative 1 year (p=0.002). Over the follow-up period a further decrease of peak transvalvular gradients was observed in all patients: 62.5$\pm$38.0 mmHg on preoperative assessment, 18.2$\pm$6.8 mmHg at immediate postoperative period (p < 0.0001), 7.6$\pm$5.09 mmHg (p<0.0001) at 6 month, 18.0$\pm$10.8 mmHg (p<0.0001) at 1 year. Conclusion: The On-X prosthetic heart valve performs satisfactorily in the first 1 year period. Clinical outcome by examining NYHA functional classification revealed especially good results. Effective regression of left ventricular hypertrophy and statistically significant decrease of transvalvular gradient were observed over the first year, but longer-term follow-up of this patient group is needed to establish the expected rates for late valve-related events as well as the long-term clinical efficacy of this valve.