• Title/Summary/Keyword: Patient Flow

Search Result 636, Processing Time 0.027 seconds

Hospital Emergency Department Simulation for Resource Analysis

  • Kozan, Erhan;Diefenbach, Mel
    • Industrial Engineering and Management Systems
    • /
    • v.7 no.2
    • /
    • pp.133-142
    • /
    • 2008
  • The Emergency Department (ED) is an integral part of hospitals. Admissions from the ED account for a significant proportion for a hospital's activity. Ensuring a timely and efficient flow of patients through the ED is crucial for optimising patient care. In recent years, ED overcrowding and its impact on patient flow has become a major issue facing the health sector. Simulation is rapidly becoming a tool of choice when examining hospital systems due to its capacity to involve numerous factors and interactions that impact the system. An analytical simulation model is used to investigate potential impacts by changing the following aspects of ED (physical layouts; number of beds; number and rate of patient arrivals; acuity of illness or injury of patients; access to radiology and pathology services; hospital staffing arrangements; and access to inpatient beds). Results of a significant numerical investigation at a hospital are also presented.

Ideal Internal Carotid Artery Trapping Technique without Bypass in a Patient with Insufficient Collateral Flow

  • Chung, Joon-Ho;Shin, Yong-Sam;Lim, Yong-Cheol;Park, Min-Jung
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.4
    • /
    • pp.260-263
    • /
    • 2009
  • Internal carotid artery (ICA) trapping can be used for treating intracranial giant aneurysm, blood blister-like aneurysms and ICA rupture during the surgery. We present a novel ICA trapping technique which can be used with insufficient collaterals flow via anterior communicating artery (AcoA) and posterior communicating artery (PcoA). A patient was admitted with severe headache and the cerebral angiography demonstrated a typical blood blister-like aneurysm at the contralateral side of PcoA. For trapping the aneurysm, the first clip was placed at the ICA just proximal to the aneurysm whereas the distal clip was placed obliquely proximal to the origin of the PcoA to preserve blood flow from the PcoA to the distal ICA. The patient was completely recovered with good collaterals filling to the right ICA territories via AcoA and PcoA. This technique may be an effective treatment option for trapping the aneurysm, especially when the PcoA preservation is mandatory.

Respiratory air flow measuring technique without sensing element on the flow stream (호흡경로 상에 감지소자가 없는 새로운 호흡기류 계측기술)

  • Lee, In-Kwang;Park, Jun-Oh;Lee, Su-Ok;Shin, Eun-Young;Kim, Kyung-Chun;Kim, Kyung-Ah;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.294-300
    • /
    • 2009
  • Cardiopulmonary resuscitation(CPR) is performed by artificial ventilation and thoracic compression for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Quality of the pre-hospital CPR not only significantly affects the patient's survival rate but also minimizes side effects caused by CPR. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are located on the flow axis. The present study developed a new technique with no physical object on the flow stream but enabling the air flow measurement and easily incorporated with the CPR devices. A turbulence chamber was formed in the middle of the respiratory tube by locally enlarging the cross-sectional area where the flow related turbulence was generated inducing energy loss which was in turn converted into pressure difference. The turbulence chamber was simply an empty enlarged air space, thus no physical object was placed on the flow stream, but still the flow rate could be evaluated. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1 %. The present results can be usefully applied to accurately monitor the air flow rate during CPR.

Noise Removal Algorithm for Accurate Mean Arterial Pressure Measurement in Pressurized Oscillometric Method (가압식 오실로메트릭 측정법에서 정확한 평균 동맥압 측정을 위한 노이즈 제거 알고리즘)

  • Joh, In-hee;Lim, Jung-hyun;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.184-187
    • /
    • 2018
  • The most important factor in the prevention and treatment of cerebral infarction is to increase cerebral blood flow. Methods for increasing cerebral blood flow include drug-based methods, the surgery, invasive procedures directly inserting medical devices into the artery(NeuroFloTM) and so on. The noninvasive cerebral blood flow increasing device proposed in this paper can reduce the burden on the patient because the probability of complication is low and the treatment level can be determined according to the blood pressure state of the patient. In implementing such a noninvasive cerebral blood flow increasing device, it is important to measure the accurate mean arterial pressure for provision the appropriate level of treatment for the patient. Therefore, to remove a noise, analog and digital filters were used and algorithm for peak value detection, pump control algorithms and so on were.

  • PDF

Delayed fatal rupture of vertebral artery after treated with flow-diverter in fibromuscular dysplasia patient: A case report and review of the literature

  • Min-Woo Kim;Eun-Sung Park;Eun Suk Park;Dae-Won Kim
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.26 no.2
    • /
    • pp.204-209
    • /
    • 2024
  • Fibromuscular dysplasia (FMD) is a noninflammatory arterial diseases that affects predominantly women. Multiple studies have demonstrated an increased prevalence of FMD in patients who experience carotid or vertebral artery dissection (VAD). This case report presents a 57-year-old female who presented with a headache and was diagnosed with partially thrombosed giant aneurysm of vertebral artery. This aneurysm was successfully treated with flow-diverter and coil, but new onset rupture of vertebral artery was detected two weeks later, leading to internal trapping. This case report underscores the need for awareness and understanding of treatment of dissection and aneurysm in patient who is suspected FMD.

Hyperperfusion in DWI Abnormality in a Patient with Acute Symptomatic Hypoglycemic Encephalopathy

  • Park, Ji Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.2
    • /
    • pp.106-108
    • /
    • 2017
  • The perfusion change in acute symptomatic hypoglycemic encephalopathy (ASHE) is not well known. We present the perfusion-weighted imaging of a patient with ASHE. The area of diffusion-weighted imaging abnormalities and adjacent normal-appearing white matter showed increased cerebral blood volume and flow, and shortening of time-to-peak.

Bronchial Artery Embolization of Massive Hemoptysis -2 cases- (대량 객혈에 대한 기관지동맥 색전술 -치험 2례-)

  • 강경훈
    • Journal of Chest Surgery
    • /
    • v.21 no.6
    • /
    • pp.1117-1123
    • /
    • 1988
  • Prolapse of the aortic valve is the main cause of insufficiency of the aortic valve as a complication of ventricular septal defect. Aortic insufficiency gets worse by the progress of prolapse of aortic valve due to lack of support of the valve and the hemodynamic effect of blood flow through the ventricular septal defect. This produces typical clinical picture, that may be serious and threatening when it is untreated. Type and timing for the surgical treatment of the ventricular septal defect with aortic insufficiency is considered. Among 113 ventricular septal defect, 9 patients of ventricular septal defect with associated aortic insufficiency were experienced from June. 1983 to June 1988 at the Department of Thoracic and Cardiovascular Surgery, Chon-Buk University Hospital. Male was 6 patients and female was 3 patients. Ages were from 7 years to 24years. 5 patients were from 10 to 19 years age. 3 patients were below 10 years age. The ratio of pulmonary blood flow to systemic f low [Qp/Qs] was 1.53 and in pulmonary vascular resistance, normal or slight increase was 7 patients, moderate 1 patient, and severe 1 patient. Ventricular septal defect was subpulmonic in 5 patients and infracristal in 4 patients. Prolapse of right coronary cusp was 7 patients, right and non coronary cusp 1 patient and non coronary cusp 1 patient. Teflon patch closure of ventricular septal defect was undertaken in 3 patients and primary closure in 1 patient. Among the 4 patients of defect closure alone, one patient performed valve replacement 7 months later due to progressive regurgitation and cardiac failure and the result was good. The other 3 patients were good result. Closure of ventricular septal defect and aortic valvuloplasty performed in 4 patients. 2 patients of these required valve replacement for the sudden intractable cardiac failure and died due to low cardiac output. The cause of intractable cardiac failure was tearing of repaired valve at the fixed site. The other 2 patients were good result. Closure of ventricular septal defect and valve replacement performed in 1 patient with good result.

  • PDF

Effects of Magnetic Therapy to Improve on Pain Threshold, Blood Flow, and Balance in Patient with Knee Osteoarthritis (자기장 치료법이 무릎 뼈관절염 환자의 통증 역치, 혈류량 및 균형능력에 미치는 영향)

  • Kyong-Hun Kim;Dong-Hoon Kim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.3
    • /
    • pp.127-135
    • /
    • 2023
  • Purpose : This study was performed to evaluate the effects of magnetic therapy (MT) on pain threshold, blood flow, and balance in patients with knee osteoarthritis. Methods : A single-blind, randomized controlled trial (RCT) was conducted with 30 patient with knee osteoarthritis. They were randomly allocated 2 groups; magnetic therapy group (MTG; n=15) and placebo magnetic therapy group (PG; n=15). The MTG group received 30 minutes magnetic therapy and 20 minute conservative physical therapy (Hotpack, ICT), magnetic therapy was conducted in magnetic therapy device (OM-100, NUGA, Korea). In the placebo magnetic group received 30 minutes placebo magnetic therapy and 20 minute conservative physical therapy. Each group performed 50 minutes a day 3 times a week for 8 weeks. The primary outcome pressure pain threshold test, blood flow, balance ability were measured by a pressure threshold meter (Commander algometer, JTECH medical, USA), laser dofler image (Moor LDI2-IR, Moor instruments, USA), balance measurement system (BioRescue, Marseille, France). The measurement were performed before and after the 8 weeks intervention period. Results : Both groups demonstrated significant improvement of outcome in pain threshold, blood flow, and balance ability during intervention period. magnetic therapy group revealed significant differences in pain threshold, blood flow, and balance as compared to the placebo magnetic therapy group groups (p<.05). Our results showed that magnetic therapy was more effective than placebo therapy on pain threshold, blood flow, and balance in patients with knee osteoarthritis. Conclusion : Our findings indicate that magnetic therapy can improve pain threshold, blood flow, and Balance, highlight the benefits of magnetic therapy. This study will be able to be used as an intervention data for recovering pain threshold, blood flow, and balance in patients with knee osteoarthritis.

Development of an Anaesthesia Ventilator by Volume Control Method and a Gas Monitoring System (가스 모니터 및 볼륨 제어 방식의 마취기용 인공 호흡기 개발)

  • Lee, Jong-Su;Seong, Jong-Hun;Kim, Yeong-Gil
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.4
    • /
    • pp.42-48
    • /
    • 2000
  • Generally an operator would take notice at putting a patient under anesthesia. If the operation is executed in mistake, the patient is exposed to danger. The object of this Paper is that a system is developed for an accuracy of system and a convenience of user interface to prevent an operation of several elements of risk by mistake. The part of electrical system particularly is made for convenience of a manipulation using electrical switch and encoder. A real-time monitoring system is developed for an airway pressure and a gas concentration of carbon dioxide of patient using graphic LCD(liquid crystal display). Moreover, this flow control system could be developed control with accuracy by feedback control method. This is implemented using flow control valve and flow sensor. The implemented system gives convenience and precision of a manipulation of variable value using developed technique. This system shows guaranteed stabilization and confidence of anesthesia ventilator by notifying us that patient's state and information in case of being out of alarm range of variable value.

  • PDF

Power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow: A technical report

  • Oh, Song Hee;Seo, Yu-Kyeong;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.301-306
    • /
    • 2019
  • Purpose: This report presents a procedure for performing power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow and illustrates its application to practical patient cases. Materials and Methods: The salivary gland was scanned using ultrasound equipment (GE LOGIQ5 Expert® device; GE Medical Systems, Milwaukee, WI, USA) to identify pathological findings related to the patient's chief complaint. To identify the orifice of the main duct, it should be cannulated using a lacrimal dilator. After inserting the catheter into the cannulated main duct, the position of the catheter within the duct was confirmed by ultrasound. A contrast agent was injected until the patient felt fullness, and ultrasound (B-mode) was used to confirm whether the contrast agent filled the main canal and secondary and tertiary ducts. Then, power Doppler ultrasound was performed to determine whether the salivary gland had increased blood flow. Results: In 2 cases in this report, a power Doppler ultrasound scan showed a significant increase in blood flow after contrast medium injection, which was not observed on a preoperative scan. Conclusion: Power Doppler ultrasound was found to be a simple, safe, and effective tool for real-time sialography monitoring.