• Title/Summary/Keyword: Patient's data

Search Result 2,903, Processing Time 0.043 seconds

A Survey of University Students' Perception of Kindness over Dental Staff in Using Dental Care Services in an Area (일부지역 대학생의 치과의료서비스 이용시 의료진의 친절인식정도 조사)

  • Lee, Chun-Sun;Lee, Kyung-Hee
    • Journal of dental hygiene science
    • /
    • v.10 no.6
    • /
    • pp.473-479
    • /
    • 2010
  • This study purposed to survey D university students' perception of kindness in their use of dental care services in an area of Gyeonggido. For this purpose, we conducted a questionnaire survey of 502 students from October 2, 2008 to March 6, 2009 and analyzed the data. Results obtained from this study are as follows. 1. Of the subjects, 71.3% were female, 67.7% were at the age of 20 or younger, and 89.2% had experience in visiting a dental clinic. Among the subjects who had experience in visiting a dental clinic, 31.1% replied that they were highly interested in oral health, and to the question on the selfperceived current oral health condition, 35.1% replied that there was something wrong in their oral health condition. 2. With regard to correlation between general characteristics and interest in oral health, 79.9% of the male subjects and 83.2% of the female ones were highly interested in oral health. According to age, interest in oral health was highest among those aged 26 or older 92.0%. 3. With regard to correlation between general characteristics and oral health condition, if the presence of dental caries or periodontal disease was considered an indicator of poor oral health, 66.0% of the male subjects and 70.9% of the female ones appeared unhealthy, 72.0% of students aged 26 or older showed satisfaction. 4. The most frequent reason for not visiting a dental clinic was 'Not sick' 34.6%, and among those who had experience, the most frequent reason for visiting was 'To get treatment of sick teeth' 63.0%. With regard to the perceived kindness of dentist and dental hygienist, 40.6% and 45.8% of the subjects, respectively, were highly satisfied. The most frequent reason for satisfaction was 'Comfortable with patient reception' 34.4% and the most frequent reason for dissatisfaction was 'Explain treatment insufficiently' 30.7%. 5. As to perceived kindness according to gender, 60.9% of the male subjects and 56.1% of the female ones were satisfied with dentist's kindness, and 66.9% and 59.6%, respectively, were satisfied with dental hygienist's kindness. According to age, 62.5% of students aged 26 or older showed satisfaction with dentist's kindness and 78.3% of them with dental hygienist's kindness. 6. As to perceived kindness according to correlation between interest in oral health and current selfperceived oral condition, the kindness of dentists(68.0%) and hygienists(67.8%) was perceived higher when interest in oral health was high and not very interested and the kindness of dentists(50.0%) and hygienists(66.78%) when selfperceived oral condition was healthy, and the difference was statistically significant (p<.022 and p<.023, respectively).

From the Onset of Panic Symptoms to Getting to a Psychiatric Treatment : The Change by Improved Public Awareness of Panic Disorder in Korea (증상의 발현부터 치료의 시작까지 : 한국인의 공황장애 인식도 변화가 치료적 접근에 미친 영향)

  • Choi, Yong-Won;Seo, Ho-Jun;Han, Sang-Woo;Hong, Jin-Pyo;Lee, Kyoung-Uk;Kim, Se-Joo;Lim, Se-Won;Lee, Sang-Hyuk;Yang, Jong-Chul;Lee, Seung-Jae;Park, Seon-Cheol;Gim, Min-Sook;Chae, Jeong-Ho
    • Anxiety and mood
    • /
    • v.15 no.2
    • /
    • pp.61-67
    • /
    • 2019
  • Objective : This study aimed to investigate the general process from the symptom onset to the psychiatric treatment in Korean panic patients and the effect of improved public awareness on it. Methods : This study has a retrospective design. The subjects were the new patients with panic disorder who visited the psychiatric outpatient clinic in twelve university-affiliated hospitals all across Korea. The medical chart was reviewed retrospectively and the data were collected including chief complaints of symptoms, recent stressors, the time to visit the psychiatric outpatient clinic, and visit of other departments and diagnostic approaches for their symptoms. Results : A total of 814 participants were included in the study. The most common department other than psychiatry the panic patients visited were cardiology (28.3%), general internal medicine (16.0%) and neurology (11.4%). The most frequently used diagnostic tests were a echocardiography (17.9%), 24-hour Holter monitoring (11.2%), and brain MRI (8.2%). Only 37.3% of participants visited psychiatric clinic directly. About 80% of participants visited psychiatric department within 1 year after their first panic symptoms and it took $13.8{\pm}13.7weeks$ on average. Comparing before and after 2012, the number of participants increased who visit directly the psychiatric clinic without visiting other departments (p=0.002) and without visiting emergency room (p<0.001). Conclusions : Our results suggest that a substantial number of patients visit departments other than psychiatry when they experience first panic symptoms. However, most patients begin psychiatric treatment within 1 year after their first symptoms and the number of patient are increasing who visit psychiatric department directly without visiting other departments.

Epidemiology of Staphylococcus aureus Bacteremia in Children at a Single Center from 2002 to 2016 (단일 기관에서 2002년부터 2016년까지 발생한 소아 황색포도알균 균혈증의 역학)

  • Lim, Seonhee;Ha, Seok Gyun;Tchah, Hann;Jeon, In Sang;Ryoo, Eell;Son, Dong Woo;Cho, Hye Jung;Sun, Yong Han;Kim, Hyo Jung;Ahn, Jung Min;Cho, Hye-Kyung
    • Pediatric Infection and Vaccine
    • /
    • v.26 no.1
    • /
    • pp.11-21
    • /
    • 2019
  • Purpose: We aimed to investigate the epidemiological characteristics of Staphylococcus aureus bacteremia in Korean children. Methods: We retrospectively collected and analyzed data from the medical records of the patients with S. aureus bacteremia ${\leq}18years$ of age in Gil Medical Center from 2002 to 2016. Results: A total of 212 SAB cases were detected. The annual incidence of SAB from 2002 to 2016 ranged from 0.77 to 1.95 per 1,000 patients hospitalized. The neonate group (<28 days of age) and the pediatric group (28-18 years of age) were 51.4% (n=109) and 48.6% (n=103), respectively. According to the origin of infection, there were 93 cases (43.9%) of community-associated (CA)-SAB and 119 cases (56.1%) of healthcare-associated (HA)-SAB. The rates of HA-SAB among the neonate group and among the pediatric group were 64.2% and 47.6%, respectively (P=0.015). There was no difference in complications between CA-SAB and HA-SAB, but mortality was higher in HA-SAB. The proportion of methicillin-resistance S. aureus (MRSA) was the highest in neonates (88.1%), decreased with age, and was 36.4%-37.5% among children aged ${\geq}5years$. The MRSA proportion was 72.2%, showing no consistent trend over the period. Conclusions: The annual incidence of SAB and the proportion of MRSA in SAB remained constant in the recent 15 years in children. Judicious decision of antimicrobial agents for treatment considering the patient's age and the origin of infection is necessary.

The Effect of the Dental Patients' Perception about Dental Hygienist on the Social Demand of Dental Hygienist (치과 내원환자들의 치과위생사에 대한 인식도가 치과위생사의 사회적 요구도에 미치는 영향)

  • Choi, Jung-Mi;Lee, Eun-Ju
    • Journal of dental hygiene science
    • /
    • v.12 no.4
    • /
    • pp.392-403
    • /
    • 2012
  • This study aims at providing the basic data to help establish the right identity of dental hygienist and develop the work of dental hygienists, and thereby investigating the effect of patients' perception of dental hygienist on their social demand of dental hygienist, by conducting a survey of 300 patients visiting dentists around Busan-Gyeongnam region from April 7, 2012 to April 25, 2012. The collected data is statistically analyzed by SPSS (Statistical Packages for Social Science 14.0. SPSS Inc., Chicago, IL, USA). First, I analyzed the frequency by suggesting the demographic and descriptive characteristics of data, and conducted t-test and One-Way ANOVA at 5% of significance level to figure out the degree of perception and social demand of dental hygienists depending on customers' reason for visiting dentists, and also conducted regression analysis to find the effect of the perception of dental hygienist on patient's social demand of dental hygienist. The result suggests that as the perception of the dental hygienists' role, the social demand for dental hygienists' image increases, but as perception of dental hygienists' image increases, the social demand of dental hygienists' image decreases. Therefore, it suggests that as the knowledge about dental hygienists increases, patients demand their service more, while the perception of their image lowers the social demand for their image. It turns out that as the knowledge of dental hygienists increase, the social demand for the knowledge also increases.

Development of Gated Myocardial SPECT Analysis Software and Evaluation of Left Ventricular Contraction Function (게이트 심근 SPECT 분석 소프트웨어의 개발과 좌심실 수축 기능 평가)

  • Lee, Byeong-Il;Lee, Dong-Soo;Lee, Jae-Sung;Chung, June-Key;Lee, Myung-Chul;Choi, Heung-Kook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.73-82
    • /
    • 2003
  • Objectives: A new software (Cardiac SPECT Analyzer: CSA) was developed for quantification of volumes and election fraction on gated myocardial SPECT. Volumes and ejection fraction by CSA were validated by comparing with those quantified by Quantitative Gated SPECT (QGS) software. Materials and Methods: Gated myocardial SPECT was peformed in 40 patients with ejection fraction from 15% to 85%. In 26 patients, gated myocardial SPECT was acquired again with the patients in situ. A cylinder model was used to eliminate noise semi-automatically and profile data was extracted using Gaussian fitting after smoothing. The boundary points of endo- and epicardium were found using an iterative learning algorithm. Enddiastolic (EDV) and endsystolic volumes (ESV) and election fraction (EF) were calculated. These values were compared with those calculated by QGS and the same gated SPECT data was repeatedly quantified by CSA and variation of the values on sequential measurements of the same patients on the repeated acquisition. Results: From the 40 patient data, EF, EDV and ESV by CSA were correlated with those by QGS with the correlation coefficients of 0.97, 0.92, 0.96. Two standard deviation (SD) of EF on Bland Altman plot was 10.1%. Repeated measurements of EF, EDV, and ESV by CSA were correlated with each other with the coefficients of 0.96, 0.99, and 0.99 for EF, EDV and ESV respectively. On repeated acquisition, reproducibility was also excellent with correlation coefficients of 0.89, 0.97, 0.98, and coefficient of variation of 8.2%, 5.4mL, 8.5mL and 2SD of 10.6%, 21.2mL, and 16.4mL on Bland Altman plot for EF, EDV and ESV. Conclusion: We developed the software of CSA for quantification of volumes and ejection fraction on gated myocardial SPECT. Volumes and ejection fraction quantified using this software was found valid for its correctness and precision.

A Study on Practice of Infection Control by Dental Hygienists -With Reference to Seoul and Incheon·Gyeonggi Province- (치과위생사의 감염방지 실천 정도에 관한 연구 - 서울 및 인천·경기도를 중심으로-)

  • Park, Hyang-Sook;Choi, Jung-Young;Sim, Su-Hyun;Kim, Jin-Soo;Choi, Boo-Keun;Jang, Hee-Kyung
    • Journal of dental hygiene science
    • /
    • v.8 no.4
    • /
    • pp.275-281
    • /
    • 2008
  • Background: This research aims to provide basic data for dental hygienists to implement the infection control after understanding the level of their implementation of infection control in case they have been trained of infection control or not. Method: The respondents in this research are the dental hygienists who worked in the Incheon or Gyeonggi areas between June 16 and July 5, 2008 and who attended complementary training conducted by the Seoul Branch of Korean Dental Hygienists Association in April 2008. A total of 191 questionnaires were distributed to them, and the frequency of the collected data was analyzed using SPSS WIN 12.0. Moreover, cross-tabulation analysis (${\chi}^2$) whose significance level was 0.05, was applied to the data in order to verify the statistical significance of the survey method. Result: There was significant difference in their practice to wear gloves and/or a mask, use a disposable apron and the time to change the apron depending upon the respondents' workplace. There was significant difference in the time to change their apron depending upon the respondents' time of service. 91.6% had been trained in the infection control: of them, 70.7% trained at their school. It was found that 68.6% of the respondents who had been trained in the infection control would wash their hands before treating a patient. 50.3% of the respondents who had been trained in the prevention of contamination would wear their gloves as needed for a basic treatment. Conclusion: Considering the above results of this research, it is concluded that it is necessary to provide practicing dental hygienists with many opportunities for systematic and practical training so that they may faithfully follow the guidelines for the prevention of contamination and to encourage hospitals to have a greater store of relevant facilities, equipment and supplies.

  • PDF

The Etiologies and Initial Antimicrobial Therapy Outcomes in One Tertiary Hospital ICU-admitted Patient with Severe Community-acquired Pneumonia (국내 한 3차 병원 중환자실에 입원한 중증지역획득폐렴 환자의 원인 미생물과 경험적 항균제 치료 성적의 고찰)

  • Lee, Jae Seung;Chung, Joo Won;Koh, Yunsuck;Lim, Chae-Man;Jung, Young Joo;Oh, Youn Mok;Shim, Tae Sun;Lee, Sang Do;Kim, Woo Sung;Kim, Dong-Soon;Kim, Won Dong;Hong, Sang-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.5
    • /
    • pp.522-529
    • /
    • 2005
  • Background : Several national societies have published guidelines for empirical antimicrobial therapy in patients with severe community-acquired pneumonia (SCAP). This study investigated the etiologies of SCAP in the Asan Medical Center and assessed the relationship between the initial empirical antimicrobial regimen and 30 day mortality rate. Method : retrospective analysis was performed on patients with SCAP admitted to the ICU between March 2002 and February 2004 in the Asan Medical Center. The basic demographic data, bacteriologic study results and initial antimicrobial regimen were examined for all patients. The clinical outcomes including the ICU length of stay, the ICU mortality rate, and 30 days mortality rates were assessed by the initial antimicrobial regimen. Results : One hundred sixteen consecutive patients were admitted to the ICU (mean age 66.5 years, 81.9 % male, 30 days mortality 28.4 %). The microbiologic diagnosis was established in 58 patients (50 %). The most common pathogens were S. pneumoniae (n=12), P. aeruginosae (n=9), K. pneumonia (n=9) and S. aureus (n=8). The initial empirical antimicrobial regimens were classified as: ${\beta}$-lactam plus macrolide; ${\beta}$-lactam plus fluoroquinolone; anti-Pseudomonal ${\beta}$-lactam plus fluoroquinolone; Aminoglycoside combination regimen; ${\beta}$-lactam plus clindamycin; and ${\beta}$-lactam alone. There were no statistical significant differences in the 30-day mortality rate according to the initial antimicrobial regimen (p = 0.682). Multivariate analysis revealed that acute renal failure, acute respiratory distress syndrome and K. pneumonae were independent risk factors related to the 30 day mortality rate. Conclusion : S. pneumoniae, P. aeruginosae, K. pneumonia and S. aureus were the most common causative pathogens in patients with SCAP and K. pneumoniae was an independent risk factor for 30 day mortality. The initial antimicrobial regimen was not associated with the 30-day mortality.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

Clinical Features and the Natural History of Dietary Protein Induced Proctocolitis: a Study on the Elimination of Offending Foods from the Maternal Diet (식품 단백질 유발성 직결장염의 임상 소견과 식이 조절에 관한 연구)

  • Choi, Seon Yun;Park, Moon Ho;Choi, Won Joung;Kang, Una;Oh, Hoon Kyu;Kam, Sin;Hwang, Jin-Bok
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.8 no.1
    • /
    • pp.21-30
    • /
    • 2005
  • Purpose: The aim of this study was to identify the clinical features and natural history of dietary protein induced proctocolitis (DPIPC) and to detect the causative foods of DPIPC, and to evaluate the effect of elimination of the foods on the course of the disease. Methods: Between March 2003 and July 2004, data from 30 consecutive patients with DPIPC who were followed for over 6 months, was reviewed. The diagnostic criterion used for DPIPC was an increase in the number of eosinophils in the lamina propria (${\geq}60per$ 10 high-power fields). In breast feeding mothers, 5 highly allergenic foods were eliminated from the maternal diet for 7 days, namely, allergenic food groups such as dairy products, eggs, nuts and soybean, fish and shellfish, and wheat and buckwheat. We observed the disappearance or appearance of hematochezia after elimination or challenge with the offending foods. Results: Before diagnosis infants were breast-fed (93.3%) or formula-fed (6.7%). Mean age at symptom onset was $11.5{\pm}5.1$ (5~24) weeks, and mean age at diagnosis was $17.8{\pm}9.5$ (8~56) weeks. Duration from symptom onset to diagnosis was $6.3{\pm}6.7$ (0~36) weeks. Mean peripheral blood eosinophil count was $478{\pm}320$ (40~1,790)/$mm^3$ and eosinophilia (> $250/mm^3$) was observedin 90.0% of patients. None of patients were found to have an increased serum IgE level. Of 15 patients that received sigmoidoscopy, nodular hyperplasia with erosion was observed in 93.3%. Of 27 patients whose mother ate the diet eliminated the 5 food groups, hematochezia diappeared in 74.1% of patients. Offending foods were identified as dairy products (37.5%), wheat and buckwheat (27.5%), fish and shellfish (20.0%), nuts and soybean (7.5%) and eggs (7.5%). A free maternal diet without patient's clinical symptoms was achieved at $29.4{\pm}8.7$ (9~44) weeks of patient's age, and a free baby diet without blood in stools was achieved at $37.5{\pm}9.7$ (12~56) weeks of age. Conclusion: DPIPC commonly occurs in exclusively breast-fed babies. Elimination of the above-mentioned 5 hyper-allergenic food groups from the maternal diet for 7days enables the detection of the offending foods. DPIPC is a transient disorder and 96.0% of patients can tolerate the offending foods at 12 months of age.

  • PDF

Suitability of Measuring a Kidney Depth with Assessment of Glomerular Filtration Rateusing 99mTc-DTPA in the Ectopic Kidney and Pediatric Patients (99mTc-DTPA를 이용한 사구체여과율 검사에서 이소성 신장과 소아 환자의 신장 깊이 측정방법의 적절성)

  • Choi, Jae Min;Lee, Young Hee;Shim, Dong Oh
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.62-67
    • /
    • 2014
  • A glomerular filtration rate (GFR) study is a test that uses radioactive materials or tracers (radiopharmaceuticals) and a computer to see how well the kidneys are working. Asan Medical Center analyzed and compared data between kidney depth, acquired from kidney donors' CT image and acquired from Gates method's GFR value that are calculated by Tonnesen equation. This study was able to confirm that kidney depth measured from CT image was higher than the Gates Method's GFR value, which was calculated by Tonnessen equation; the direct relationship among pathologic results is confirmed. Particularly, kidney donor whose kidney was at the pelvic area had direct relationship with other clinical results. During the GFR test, it is necessary to confirm the location of kidney has no change with reference of CT image. If kidney depth is manually corrected using CT image when we measures GFR of deformed or horse-shoe kidney, it would be possible to acquire the compatible value which is equivalent to clinical result. There would be a possible issue of appropriateness that whether the applied GFR using CT image's kidney depth has clinical validity. In case of a pediatric patient, the GFR derived from Tonnesen was quiet underestimated while manual method and Gordon stay in normal range. Which results may be correct among them? There have been many reports about kidney depth, to be an accurate index of GFR in children. As one of the study performers, we should contemplate what the best option for pediatric patients would be.

  • PDF