• Title/Summary/Keyword: PatentNOW

Search Result 68, Processing Time 0.036 seconds

Physiological Function of Endothelial Cells Cultured on Polyurethsne Coated by ECM (인조혈관재료 표면에 도포된 혈관내피세포의 생리적 변화에 관한 연구)

  • 이윤신;김용배
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.255-262
    • /
    • 1996
  • Antithrombogenic surFace is one of the most important things to the artificial vascular prostheses. This problem will be solved if the surface of prosthesis is covered with endothelial cells. The attachment and the growth of endothelial cells onto vascular prosthesis are very difficult. So many studies have been concentrated on the attachement of endothelial cell. But no good performance of the in uiwo experiments has been shown until now. In this study, we used the whole extracellular matrix (ECM) excreted from fibroblasts as an underlying matrix, and the endothelial cells were seeded to obtain the long term patency of vascular graft(i.e., for the patent 8 week implanted wafts in the animal model of rat). In order to study the antithrombogenic functions of cultured endothelial cells, prostaglandin(PGF 1 a) synthesis and platelet adhesion were assayed. The concentration of PGF a of stimulated group was sisnificantly higher than that of control group(21.97 $\pm$ 3.45 vs 4.93 $\pm$0.71 pg/1000 cells). The platelet adhesion of the polyurethane sheet covered with endothelial cells was lower than that of polyurethane sheet or sheet covered with ECM(1.04$\pm$0.28, 2.87$\pm$0.77, 2.89$\pm$0.70, % radioactivities, respectively). Endothelial cells grew well on polyurethane coated with ECM, synthesized the prostacyclin and functioned well as antithrombogenic. Therefore the endothelialization onto the ECM excreted from fibroblasts may be a good method for the vfudig prosthesis.

  • PDF

Distal Type of Aortopulmonary Septal Defect with Aortic Origin of Right Pulmonary Artery and Interruption of the Aortic Arch - A Case of Successful Surgical Report -

  • Jeong, Yun-Seop;Song, Myeong-Geun
    • Journal of Chest Surgery
    • /
    • v.24 no.7
    • /
    • pp.693-700
    • /
    • 1991
  • A rare case of the association of distal aortopulmonary septal defect, aortic origin of the right pulmonary artery, intact ventricular septum, patent ductus arteriosus and interrupted aortic isthmus in a 40-day-old infant is reported. The infant was suffered from two operations with an interval of nine days. At the first operation a 10mm polytetrafluoroethylene prosthesis was inserted instead of the interrupted aortic isthmus and ductus was ligated via the left posterolateral thoracotomy. But the patient could not be weaned from the respirator because of large amount of left-to-right shunt. So the total correction was subsequently performed after an interval of nine days. At the second operation, tunneling of the right pulmonary artery to the main pulmonary artery through the aortopulmonary septal defect was performed using the Dacron patch via a longitudinal transaortic approach and a separate autologous pericardial patch was applied to the longitudinally incised margins of the anterior wall of the ascending aorta. The second postoperative course was relatively uneventful except some respiratory distress and nutritional problems. Now he is at 6 months of age and thrives well without any symptom. Because the success of the surgical repair of this complex anomalies depends upon the accurate diagnosis and meticulous design of each step of procedure prior to operation these problems are also discussed.

  • PDF

Understanding Underlying Processes of Water Electrolysis (수소 생산을 위한 물 전기분해 이해 및 기술동향)

  • Lee, Jaeyoung;Yi, Youngmi;Uhm, Sunghyun
    • Applied Chemistry for Engineering
    • /
    • v.19 no.4
    • /
    • pp.357-365
    • /
    • 2008
  • Hydrogen energy becomes more attractive in that it can resolve the exhaustion of fossil fuels and their environmental problems. Until now, water electrolysis has been a interesting technique to produce hydrogen from non-fossil fuels. In principle, water electrolysis is an environmentally friendly technique to split water into hydrogen and oxygen, so that it can be utilized without any limitation of resources. Herein, we introduce basic understanding and three types of water electrolysis. Furthermore, the research trend and patent analysis will be followed along with an outlook.

The Effect on Performance with SCM Dynamic Capabilities in the Pharmaceutical Industry : Mediated Through Cooperational Relationship (제약산업의 SCM 동적역량이 성과에 미치는 영향: 협력관계를 매개로 하여)

  • Seo, Young-Kyu;Song, Dohan;Huh, Hoon
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.44 no.3
    • /
    • pp.192-206
    • /
    • 2021
  • The pharmaceutical industry is an industry that provides medicines related to the health and life of the people. The pharmaceutical industry is a traditional regulation industry with the characteristics of R&D(Research and Development), purchasing, manufacturing, distribution and consumption under strict government management. Until now, pharmaceutical companies have continued to make efforts to maintain competitiveness through patent management, new product development, and marketing. However, industries are rapidly changing, including rising costs for developing new products and expanding generic markets. As these changes and uncertainties in the management environment increase, efforts are required to improve the competitiveness of the pharmaceutical industry from a new perspective. In this study, we intend to examine the impact of SCM(Supply Chain Management) dynamic capability of pharmaceutical companies on corporate performance through partnerships to respond to market changes and uncertainties. It was determined that the agility, visibility and flexibility that constitutes the SCM dynamic capabilities would affect the performance of pharmaceutical companies. In this study, the importance of SCM dynamic capabilities and cooperative relationships was identified through surveys by SCM managers of pharmaceutical companies. Consequently, in the pharmaceutical industry, which is a regulatory industry, we have identified that SCM dynamic capabilities and cooperative relationships with partner companies have a significant impact on corporate performance.

Discovering Applicable Lessons for '3D Printing R/D Project' Implementation Through Studying the Process of Adopting Overseas Industrialized Building Production Technological Knowhow in the Korean Context (한국의 공업화건축 공법 도입활용과정 분석을 통한 3D 프린팅기술 개발 방향성 연구)

  • Lee, Sung-Min;Lee, Pil-Won;Cho, Hoo-Young;Lee, Jae-Heon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.4
    • /
    • pp.59-68
    • /
    • 2017
  • This paper aims at finding some lessons applicable to successful implementation of 'The 3D Printing R/D Project' through both examining the process of adopting overseas industrialized housing production technological knowhow by home builders during the 1970's~1980's period and thereafter until now the various efforts to adjust the technologies efficiently to the Korea's unique situation. Some meaningful lessons can be summarized as follows; I) Deep understanding of 3DP technological know-why along with its inheritance, II) Readjusting of R/D period and goals(cf. Global leader Winsun's 15 years experiment), III) Restructuring for more collaborative R/D B&E system among participating researchers IV) Fostering 3DP expert-engineers and technicians from the early stage, V) Clearing legal barriers in users' adopting 3DP methods necessary, VI) Development of appropriate building material besides concrete. Therefore, it is highly recommended that the above-mentioned 6 lessons positively accepted and applied to the Research Implementation Plan in due course, especially by KICT consortium and KAIA under the guidance of Ministry of Land, Infrastructure and Transport.

Development of Investment Casting Technique using R/P Master Model (R/P 마스터모델을 활용한 정밀주조 공정기술의 개발)

  • Im, Yong-Gwan;Chung, Sung-Il;Jeong, Hae-Do
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.6
    • /
    • pp.52-57
    • /
    • 1999
  • Funtional metal prototypes are often required in numerous industrial applications. These components are typically needed in the early stage of a project to determine form, fit and function. Recent R/P(Rapid Prototyping) part are made of soft materials such as plastics, wax, paper, these master models cannot be employed durable test in real harsh working environment. Parts by direct metal rapid tooling method, such as laser sintering, by now are hard to get net shape, pores of the green parts of powder casting method must be infiltrated to get proper strength as tool, and new type of 3D direct tooling system combining fabrication welding arc and cutting process is reported by song etc. But a system which can build directly 3D parts of high performance functional material as metal part would need long period of system development, massive investment and other serious obstacles, such as patent. In this paper, through the rapid tooling process as silicon rubber molding using R/P master model, and fabricate wax pattern in that silicon rubber mold using vacuum casting method, then we tranlsated the wax patterns to numerous metal prototypes by new investment casting process combined conventional investment casting with rapid pototyping & rapid tooling process. with this wax-injection-mold-free investment casting, we developed new investment casting process of fabricating numerous functional metal prototypes from one master model, combined 3-D CAD, R/P and conventional investment casting and tried to expect net shape measuring total dimension shrinkage from R/P part to metal part.

  • PDF

Analysis of China's Efforts to Protect Medicinal Resources and the Intellectual Property Rights of Traditional Chinese Medicine - in light of the adoption of the Nagoya Protocol - (중국의 약물자원 및 전통의약 지식재산권 보호 동향 분석 -「나고야의정서」 채택과 관련하여-)

  • Lee, Min-Ho
    • The Korea Journal of Herbology
    • /
    • v.27 no.5
    • /
    • pp.45-53
    • /
    • 2012
  • Objectives : In recent years, the Chinese Government has been providing full support aimed at promoting the excellence of Chinese culture, including Traditional Chinese Medicine (TCM), to the world after recognizing Chinese culture and medicine as elements that can generate national wealth. Methods : In investigating China's awareness of the issues surrounding the intellectual property rights of TCM, as well as its implementation of protective measures, this study analyzed the law and platform policies of the Chinese Government, as well as the designation status of China's intangible cultural heritages and the recent research trend in the TCM field. Results : First, China is taking various protective measures based on laws and institutional devices, including the Patent Act. Second, China is protecting the intellectual property rights of traditional Chinese medicines by registering them as Chinese intangible cultural heritages or UNESCO world heritages. Third, China is seeking to promote TCM throughout the wider world through various research and academic conferences, and by strengthening ties between nations. Conclusions : With the adoption of the international regimes of the WIPO and CBD, and particularly the Nagoya Protocol in 2010, China is seeking to implement measures aimed at maximizing the national interest based on the intellectual property rights of TCM. China began to implement a system of protection of medicinal resources and the related traditional knowledge after recognizing the potential crisis that could occur if Chinese medicine-related patents were taken over by foreign countries. As such, the system now takes various forms.

Bending 30-gauge needles using a needle guide: fatigue life evaluation

  • Jared Joseph Tuttle;Andrew Doran Davidson;Gregory Kent Tuttle
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.5
    • /
    • pp.281-285
    • /
    • 2023
  • Background: Dentists bend needles prior to certain injections; however, there are concerns regarding needle fracture, lumen occlusion, and sharps handling. A previous study found that a 30-gauge needle fractures after four to nine 90° bends. This fatigue life study evaluated how many 90° bends a 30-gauge dental needle will sustain before fracture when bent using a needle guide. Methods: Two operators at Element Materials Technology, an independent testing, inspection, and certification company tested 48 30-gauge needles. After applying the needle guide, the operators bent the needle to a 90° angle and expressed the anesthetic from the tip. The needle was then bent back to a 0° angle, and the functionality was tested again. This process was repeated until the anesthetic failed to pass through the end of the needle due to fracture or obstruction. Each operator tested 24 needles (12 needles from each lot), and the number of sustained bends before the needle fracture was recorded. Results: The average number of sustained bends before needle failure was 40.33 (95% confidence interval = 37.41-43.26), with a minimum of 20, median of 40, and a maximum of 54. In each trial, the lumen remained patent until the needle fractured. The difference between the operators was statistically significant (P < 0.001). No significant differences in performance between needle lots were observed (P = 0.504). Conclusion: Our results suggest that using a needle guide increases the number of sustained bends before needle fracture (P < 0.000001) than those reported in previous studies. Future studies should further evaluate the use of needle guides with other needle types across a variety of operators. Furthermore, additional opportunities lie in exploring workplace safety considerations and clinical applications of anesthetic delivery using a bent needle.

Animal Experiments on an Antithrombogenic Small-Caliber Vascular Prostheses and Vascualr Patch : Observation in Canine Models (항혈전성 소구경 인조 혈관 및 봉합편에 대한 동물 실험)

  • 김수철;김원곤;유세영
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.63-72
    • /
    • 2003
  • Although a variety of synthetic vascular grafts are available in modern vascular surgery, no ideal prosthesis ha,4 yet been developed. Small-caliber vascular grafts with low flow, as used in the lower extremity, continue to become thrombosed at unacceptable rates. We have developed and evaluated the new antithrombogenic blood contacting surfaces in canine model. Material and Method: Two now antithrombogenic blood contacting surfaces(Polyvinylalcohol -Polyurethane(PVA-PU) blend and natural Graphite-polyurethane(G-PU) blend) have been developed and evaluated in canine model, using vascular grafts and patches. The luminal surfaces of the test vascular grafts(5 mm ID) were fabricated by dipping a glass rod in PVA-PU blend solution(50 % PVA) using phase separation method. Mongrel dogs of either sex weighing 18-22 kg were anesthetized by endotracheal intubation using halothane and their lungs were ventilated with a volume-cycled ventilator, Maintenance anesthesia with 0.5-1.0% halothane and supplemental oxygen was used. Two pairs were used for comparison in the bilateral femoral arteries for both vascular grafts(PVA-PU vs. PU) and vascular patches(G-PU vs. PU). Bilateral groin incisions were made and the arteries were exposed and clamped. After an excision of 1 cm of the artery between clamps, a grail of 2.5 cm in length was implanted end-to-end using 6-0 polypropylene suture. The vascular patch was implanted as a form of on-lay patch. Animals were sacrificed at 1, 2, 4, 6, 8 and 16 weeks for vascular grafts and 1, 2. 4 and 6 weeks for vascular patches. Result The vascular grafts of PVA-PU blends showed patent lumina in the 2 and 16 weeks animals, while those of PU showed a patent lumen in 2 weeks animal. PVA-PU graft of 16 weeks showed a fairly clean luminal surface. A light microscopic finding of this graft demonstrated good tissue infiltration through porosity, The animals with vascular patches showed patent arteries in both groups except 2 weeks animal. Scanning electron microscopy of the luminal surfaces of G-PU patches in 4 and 6 weeks animals showed endothelial cell covering with microvilli. PU patches showed qualitatively less endothelial cell covering. Conclusion: In conclusion, PVA-PU and G-PU blends can be a promising blood contacting surfaces for application in a synthetic vascualr graft. However, further animal study is needed to determine the real long-term effects of these methods of surface modifications.

Tracheoplasty for Congenital Tracheal Stenosis-Two case reports- (선천성 기관 협착 환자의 기관성형술 2예)

  • Lim Hong Gook;Lee Chang-Ha;Hwang Seong Wook;Lee Cheul;Kim Jae Hyun;Seo Hong Joo;Jung Sung Chol
    • Journal of Chest Surgery
    • /
    • v.38 no.8 s.253
    • /
    • pp.583-588
    • /
    • 2005
  • Congenital tracheal stenosis can be a life-threatening disease, especially in cases involving the long-segment of the trachea. When patients are symptomatic immediately after birth or develop an accompanying complex cardiac anomaly, surgical repair can be a considerable challenge. We experienced a tracheoplasty in one early infant weighing 2.6 kg and one neonate who had ventilator dependency from long-segment congenital tracheal stenosis and congenital cardiac anomaly. One early infant, who had diffuse stenosis of distal trachea after ventricular septal defect closure, underwent resection and extended end to end anastomosis. One neonate who had diffuse stenosis of proximal trachea with tetralogy of Fallot (TOF), underwent slide tracheoplasty with total correction for TOF Postoperative chest computed tomography showed widely patent trachea. Both infants are now well without symptoms.