• Title/Summary/Keyword: Patch

Search Result 3,484, Processing Time 0.027 seconds

Patch Integrity Verification Method Using Dual Electronic Signatures

  • Kim, JunHee;Won, Yoojae
    • Journal of Information Processing Systems
    • /
    • v.13 no.6
    • /
    • pp.1516-1526
    • /
    • 2017
  • Many organizations today use patch management systems to uniformly manage software vulnerabilities. However, the patch management system does not guarantee the integrity of the patch in the process of providing the patch to the client. In this paper, we propose a method to guarantee patch integrity through dual electronic signatures. The dual electronic signatures are performed by the primary distribution server with the first digital signature and the secondary distribution server with the second digital signature. The dual electronic signature ensures ensure that there is no forgery or falsification in the patch transmission process, so that the client can verify that the patch provided is a normal patch. The dual electronic signatures can enhance the security of the patch management system, providing a secure environment for clients.

The patch tests and convergence for nonconforming Mindlin plate bending elements

  • Park, Yong-Myung;Choi, Chang-Koon
    • Structural Engineering and Mechanics
    • /
    • v.5 no.4
    • /
    • pp.471-490
    • /
    • 1997
  • In this paper, the classical Irons' patch tests which have been generally accepted for the convergence proof of a finite element are performed for Mindlin plate bending elements with a special emphasis on the nonconforming elements. The elements considered are 4-node and 8-node quadrilateral isoparametric elements which have been dominantly used for the analyses of plate bending problems. It was recognized from the patch tests that some nonconforming Mindlin plate elements pass all the cases of patch tests even though nonconforming elements do not preserve conformity. Then, the clues for the Mindlin plate element to pass the Irons' patch tests are investigated. Also, the convergent characteristics of some nonconforming Mindlin plate elements that do not pass the Irons' patch tests are examined by weak patch tests. The convergence tests are performed on the benchmark numerical problems for both nonconforming elements which pass the patch tests and which do not. Some conclusions on the relationship between the patch test and convergence of nonconforming Mindlin plate elements are drawn.

Comparative Pharmacokinetics for Dermal Application of a New SYC-fentanyl Patch in Rabbits (토끼에 있어서 SYC-fentanyl패취제의 경피투여 동태비교)

  • 신호철;이영미;최학수;이정훈;유현석;한상섭
    • YAKHAK HOEJI
    • /
    • v.44 no.2
    • /
    • pp.189-192
    • /
    • 2000
  • We examined a dermal pharmacokinetics for a new SYC-fentanyl patch in rabbits. Determination of fentanyl in the plasma was performed using a gas chromatography with nitrogen-phosphorus detection system and a capillary column. One patch per animal (fentanyl 2.5 mg) was applied to clipped back skin for 72 hours. The plasma fentanyl concentration profile of SYC-patch was similar to that of a conventional patch (Durogesi $c^{R}$, Janssen Co.). No significant difference was observed in the pharmacokinetic parameters, the area under the concentration-time curve (AU $C^{0-}$72hrs/) and the total area under the first moment-time curve (AUM $C^{0-}$7hrs/), between the two patch types. The AU $C^{0-}$7hrs/ and AUM $C^{0-}$72hrs/ of durogesi $c^{R}$ were 183.3$\pm$46.28 ng*hr/ml and 6,450$\pm$1,939ng*h$r^2$/ml, and those of SYC-fentany patch were 217.2$\pm$50.51$\pm$ng*hr/ml and 8,022$\pm$2,245ng*h$r^2$/ml, respectively (n=3). This result indicates that the new SYC patch has a similar bioavailability compared to durogesi $c^{R}$ patch. Therefore, the SYC-patch may be considered as a bioequivalent fentanyl patch.patch.tch.

  • PDF

Characteristics of large patch occurrence at warm-season turfgrass in golf course (골프장의 난지형 잔디에 발생하는 Large patch의 발병 특성)

  • Woo, Hyun-Nyung;Kim, Gi-Rim;Kim, Hye-JIn;Chung, Doug-Young
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.2
    • /
    • pp.243-248
    • /
    • 2011
  • This investigation was conducted to develop an integrated disease management system against large patch disease occurred in a golf course. Large patch, brown patch, and Rhizoctonia blight sometimes are used interchangeably by turfgrass managers and researchers, Large patch disease of zoysiagrass is caused by a soilborne fungus called Rhizoctonia solani. Although this fungus is very similar to the one that causes brown patch disease of cool-season turfgrasses in mid-summer. Large patch development is favored by high thatch and soil moisture. Avoid overwatering the turfgrass, especially in the fall or early spring. Poorly-drained areas are very susceptible to injury from large patch and should be reconstructed (draining tiles, etc) to avoid soil saturation. However, control of yellow patch with fungicides is normally not recommended because the disease has only cosmetic effects and symptoms are usually very short-lived. Therefore, we reviewed the symptom of large patch to look for control method by soil management method.

Effect of the composite patch beveling on the reduction of stresses in 2024-T3 Aluminum structure damaged and repaired by composite, hybrid patch repair

  • Belhoucine, A.;Madani, K.
    • Structural Engineering and Mechanics
    • /
    • v.82 no.1
    • /
    • pp.17-30
    • /
    • 2022
  • The use of composite patches for the reduction of stresses at the level of the damaged zone in aeronautical structures has experienced rapid expansion given its advantages over conventional mechanical processes (riveting, bolting, etc.). Initially, The research axes in this field were aimed at choosing suitable mechanical properties for the composite and the adhesive, then to optimize the shape of the composite patch in order to ensure good load transfer and avoid having a debonding at the level of the edges essentially for the case of a repair by single side where the bending moment is present due to the non-symmetry of the structure. Our work falls within this context; the objective is to analyze by the finite element method the fracture behavior of a damaged plate repaired by composite patch. Stress reduction at the edge is accomplished by creating a variable angle chamfer on the composite patch. The effects of the crack length, the laminate sequence and the nature of the patch as well as the use of a hybrid patch were investigated. The results show clearly that a beveled patch reduces the stress concentrations in the damaged area and even at its edges. The hybrid patch also ensures good durability of the repair by optimizing its stacking sequence and the location of the different layers according to the fibers orientations.

Effect of the Patch Width on the Radiation Characteristics of a Pin Array Patch Antenna (패치의 폭이 핀 배열 패치 안테나의 방사 특성에 미치는 효과)

  • Yoon, Young-Min;Kim, Tae-Young;Cho, Myung-Ki;Kim, Boo-Gyoun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.1
    • /
    • pp.77-83
    • /
    • 2010
  • Radiation characteristics of $5{\times}4$ pin array patch antennas are compared to those of $5{\times}2$ pin array patch antennas for several substrate thicknesses using the computer simulation. Since the number of unit cells of a $5{\times}2$ pin array patch antenna is half of that of a $5{\times}4$ pin array patch antenna, the number of pins used in a $5{\times}2$ pin array patch antenna is half of that in a $5{\times}4$ pin array patch antenna and the patch width of a $5{\times}2$ pin array patch antenna is very small compared to that of a $5{\times}4$ pin array patch antenna. However, the radiation characteristics of a $5{\times}2$ pin array patch antenna are almost similar to those of a $5{\times}4$ pin array patch antenna.

On-line Phase Tracking of Patch Type EFPI Sensor and Fuzzy Logic Vibration Control (패치형 광섬유 센서를 이용한 구조물의 동특성 감지 및 퍼지 진동 제어)

  • 한재흥;장영환;김도형;이인
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.568-574
    • /
    • 2004
  • On-line phase tracking of an extrinsic Fabry-Perot interferometer (EFPI) and experimental vibration control of a composite beam with a sensing-patch are investigated. We propose a sensing-patch for the compensation of the interferometric non-linearity. In this paper, a sensing-patch that comprises an EFPI and a piezo ceramic(PZT) is fabricated and the characteristics of the sensing-patch are experimentally investigated. A simple and practical logic is applied for the real-time tracking of optical phase of an interferometer. Experimental results show that the proposed sensing-patch does not have the non-linear behavior of conventional EFPI and hysteresis of piezoelectric material. Moreover, it has good strain resolution and wide dynamic sensing range. Finally, the vibration control with the developed sensing-patch has been performed using Fuzzy logic controller, and the possibility of sensing-patch as a sensoriactuator is considered.

  • PDF

Anti-inflammatory and Analgesic Activities, and Skin Irritation Test of Piroxicam Patch (피록시캄 패취제의 소염, 진통 효능 및 피부자극시험)

  • 고광호;조미정;이장훈;노민수;류재련;이진화;안재석;태주호;민동선
    • Biomolecules & Therapeutics
    • /
    • v.2 no.1
    • /
    • pp.71-76
    • /
    • 1994
  • Anti-inflammatory and analgesic activities and skin irritation of piroxicam patch were investigated. Piroxicam patch increased the pain threshold in rat hind paw inflamed by carrageenan and inhibited writhing induced by acetic acid in mice. Piroxicam patch also inhibited the carrageenan-induced edema in rat hind paw as well as the increased vascular permeability induced by histamine in rats. In adjuvant arthritis of rats, piroxicam patch showed anti-inflammatory effects. Skin irritation of piroxicam patch was tested in Newzealand White rabbits and evaluated by Primary Irritation Index of Draize. The results from skin irritation test showed that piroxicam patch seemed practically non-irritating. The result from the present study indicates that piroxicam may be useful without serious side effects as anti-inflammatory analgesics in this patch form.

  • PDF

Patch Plate Repair Method for Steel Structures Combining Adhesives and Stud Bolts

  • Ishikawa, T.;Ikeda, T.
    • International journal of steel structures
    • /
    • v.18 no.4
    • /
    • pp.1410-1419
    • /
    • 2018
  • Recently, a repair method by bonding patch plates is being applied to corroded steel structures. However, one of the issues of patch plate bonding repair is the brittle debonding of the patch plates. Generally, when the delamination of the patch plates occurs, the composite effect acting between the steel members and patch plates abruptly decreases. Therefore, to prevent the brittle debonding of the patch plates, a repair method combining an adhesive and stud bolts is proposed. Till date, tensile and compressive tests have been performed for the proposed method. In this study, plate bending tests were conducted to verify the effectiveness of this method under bending conditions. Furthermore, two types of epoxy resin-based adhesives were prepared to evaluate the effectiveness of the proposed method with different adhesive properties. The test results show that the proposed method is able to prevent the brittle debonding of the patch plates in the case of both epoxy resins.

Radiation Characteristics of Patch Antennas with an Array of Pins for Various Substrate Thicknesses (기판 두께에 따른 핀 배열을 가지는 패치 안테나의 방사 특성)

  • Cho, Myung-Ki;Kim, Tae-Young;Kim, Boo-Gyoun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.10
    • /
    • pp.63-71
    • /
    • 2009
  • The patch antennas with an array of pins with excellent radiation characteristics are investigated for several substrate thicknesses. The patch length of a pin array patch antenna for the maximum suppression of radiation in the horizontal plane decreases as the substrate thickness increases. The radiation in the horizontal plane of a pin array patch antenna is very small compared to that of a conventional patch antenna. The increase of forward radiation and the decrease of backward radiation of a pin array patch are obtained compared to those of a conventional patch antenna. The half-power beamwidth of E-plane radiation pattern of a pin array patch antenna is narrow compared to that of a conventional patch antenna so that the directivity is improved.