• 제목/요약/키워드: Passive resistance

검색결과 327건 처리시간 0.026초

Precursor Events in Environmentally Assisted Cracking Behaviour of Light Metals

  • Raja, V.S.
    • Corrosion Science and Technology
    • /
    • 제15권4호
    • /
    • pp.153-158
    • /
    • 2016
  • Light metal alloys of Mg, Ti, and Al undergo environmentally assisted cracking (EAC). Passive film breakdown and pitting are not only precursor events for stress corrosion, but can accelerate hydrogen evolution that is responsible for hydrogen embrittlement. This is clearly demonstrated in the case of Mg and Ti alloys. The so-called innocuous precipitates, which do not directly participate in either alloy strengthening or EAC can be effective precursors for initiating EAC. This aspect is highlighted using high strength aluminium alloys. Such behaviours lead to a paradigm shift in the design of alloys with resistance to EAC.

Mitigation of motions of tall buildings with specific examples of recent applications

  • Kareem, Ahsan;Kijewski, Tracy;Tamura, Yukio
    • Wind and Structures
    • /
    • 제2권3호
    • /
    • pp.201-251
    • /
    • 1999
  • Flexible structures may experience excessive levels of vibration under the action of wind, adversely affecting serviceability and occupant comfort. To ensure the functional performance of a structure, various design modifications are possible, ranging from alternative structural systems to the utilization of passive and active control devices. This paper presents an overview of state-of-the-art measures that reduce the structural response of buildings, including a summary of recent work in aerodynamic tailoring and a discussion of auxiliary damping devices for mitigating the wind-induced motion of structures. In addition, some discussion of the application of such devices to improve structural resistance to seismic events is also presented, concluding with detailed examples of the application of auxiliary damping devices in Australia, Canada, China, Japan, and the United States.

TMD effectiveness for steel high-rise building subjected to wind or earthquake including soil-structure interaction

  • Kontoni, Denise-Penelope N.;Farghaly, Ahmed Abdelraheem
    • Wind and Structures
    • /
    • 제30권4호
    • /
    • pp.423-432
    • /
    • 2020
  • A steel high-rise building (HRB) with 15 stories was analyzed under the dynamic load of wind or four different earthquakes taking into consideration the effect of soil-structure interaction (SSI) and using tuned mass damper (TMD) devices to resist these types of dynamic loads. The behavior of the steel HRB as a lightweight structure subjected to dynamic loads is critical especially for wind load with effect maximum at the top of the building and reduced until the base of the building, while on the contrary for seismic load with effect maximum at the base and reduced until the top of the building. The TMDs as a successful passive resistance method against the effect of wind or earthquakes is used to mitigate their effects on the steel high-rise building. Lateral displacements, top accelerations and straining actions were computed to judge the effectiveness of the TMDs on the response of the steel HRB subjected to wind or earthquakes.

열공압 방식의 polydimethylsiloxane 마이크로 펌프의 제작 및 특성 (Fabrication and Characteristics of Thermopneumatic-Actuated Polydimethylsiloxane Micropump)

  • 김진호;문민철;김주호;김영호;김한수;한경희;김용상
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권6호
    • /
    • pp.342-346
    • /
    • 2004
  • A thermopneumatic-actuated polydimethylsiloxane (PDMS) micropump has been fabricated and their properties are characterized. The diffusers are used as a flow-rectifying element instead of passive check valves. The advantages of the proposed microvalve are of the low cost fabrication process and the transparent optical property using PDMS and indium tin oxide (ITO) glass. We presented the PDMS micropump that is easily integrated with the in-channel PDMS microvalves on the same substrate. The flowrate of the micropump increases linearly as the applied pulse voltage to the ITO heater increases. The fabricated ITO heater resistance is 6.54k$\Omega$. The peak of the flow rate is observed at the duty ratio of 10% for the applied pulse voltage of 55V at 6Hz and the maximum flow rate of 78nl/min is measured.

A Novel Switched-Capacitor Based High Step-Up DC/DC Converter for Renewable Energy System Applications

  • Radmand, Fereshteh;Jalili, Aref
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1402-1412
    • /
    • 2017
  • This paper presents a new high step-up dc/dc converter for renewable energy systems in which a high voltage gain is provided by using a coupled inductor. The operation of the proposed converter is based on a charging capacitor with a single power switch in its structure. A passive clamp circuit composed of capacitors and diodes is employed in the proposed converter for lowering the voltage stress on the power switch as well as increasing the voltage gain of the converter. Since the voltage stress is low in the provided topology, a switch with a small ON-state resistance can be used. As a result, the losses are decreased and the efficiency is increased. The operating principle and steady-states analyses are discussed in detail. To confirm the viability and accurate performance of the proposed high step-up dc-dc converter, several simulation and experimental results obtained through PSCAD/EMTDC software and a built prototype are provided.

Corrosion Characteristics of Amorphous Alloy Ribbon ($Fe_{70}Cr_5Si_{10}B_{15}$ and $Co_{70}Cr_5Si_{10}B_{15}$) in Hydrochloric Acid Aqueous Solution

  • Choi, Chil-Nam;Hyo, Kyung-Yang;Yang, Myung-Sun
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2001년도 정기총회 및 봄 학술발표회 초록집
    • /
    • pp.236-237
    • /
    • 2001
  • In this study, experiments were carried out to measure the variations in the corrosion potential and current density of polarization curves with amorphous $Fe_{70}Cr_5Si_{10}B_{15}$ and $Co_{70}Cr_5Si_{10}B_{15}$ alloy ribbon. The results were particularly examined to identify the influences of corrosion potential including various conditions such as hydrochloric acid, temperature, salt, pH, and oxygen. The optimum conditions were established with variations including temperature, salt, pH, oxygen, corrosion rate, and resistance of corrosion potential. The mass tranfer coefficient(${\alpha}$) value was determined with the Tafel's slope for the anodic dissolution based on the polarization effect with optimum conditions. The second anodic current density peak and maximum passive current density were designated as the critical corrosion sensitivity($I_{r}/I_{f}$).

  • PDF

한 개의 FTFN을 이용한 고역통과 필터의 설계 (A study on the Design of a High pass filter using single FTFN)

  • 이영훈
    • 한국컴퓨터정보학회논문지
    • /
    • 제7권3호
    • /
    • pp.56-59
    • /
    • 2002
  • 본 논문에서는 한 개의 FTFN과 3개의 수동소자를 사용하여 직 병렬 R-L 및 C-D 이미턴스 회로를 실현하였다. 또한, 설계된 회로소자의 이론적 해석의 유용함을 입증하기 위하여 설계된 소자를 써서 high pass filter를 설계하고, AD844 macro model을 이용하여 HSPICE 에 의해 컴퓨터 시뮬레이션을 수행하였다. simulation결과는 이론적인 결과와 잘 일치하였으며, 따라서 이 회로는 통신 또는 전자장치에 유용하게 이용 될 수 있다.

  • PDF

Strengthening of isolated square footings using passive wrapping systems

  • Lu, Xingji;Aboutaha, Riyad S.
    • Computers and Concrete
    • /
    • 제27권1호
    • /
    • pp.41-54
    • /
    • 2021
  • This paper introduced three new strengthening systems for isolated footings: BFRP wrapping system, CFRP wrapping system, and steel jacketing system. The proposed systems are more practical than the current traditional methods, which involves installing many dowel bars and splicing reinforcing steels to join new and old concrete segments. In the proposed three new systems, BFRP wraps, CFRP wraps, or steel jackets are installed on the exterior surface of the enlarged footing, with construction adhesive or a few steel dowels being applied to the contact surfaces. To investigate the effectiveness of three systems, forty-four models were constructed in ABAQUS, with different parameters being considered. All footings investigated failed in punching shear, including original and retrofitted footings. According to FEA results and parametric studies, the three strengthening systems were capable of improving the punching shear resistance of footings. By introducing a new factor η, the punching shear equation in Eurocode 2 was modified to predict the punching shear resistances of the strengthened footings. A linear formula was developed to present the relationship between the new factor η and the investigated parameters.

Numerical study on the post-earthquake fire behavior of intermediate steel moment frames

  • Parvizizadeh, Shayan;Kazemi, Mohammad Taghi
    • Earthquakes and Structures
    • /
    • 제22권2호
    • /
    • pp.137-145
    • /
    • 2022
  • As steel is highly sensitive to temperature variations, fire exposure is more destructive in the case of steel structures in comparison to the concrete ones. The performance of an intermediate three-story steel moment frame with 4 spans was studied under the service load, thermal load and post-earthquake fire in this paper. Also, the effects of passive fire-protection materials such as ordinary cement-based and fire-retardant coatings were investigated. To model and analyze the structure; Abaqus software is utilized. In order to apply the earthquake effect, the push-over analysis method is employed. Changes in the stories deflection, endurance time and growth of nonlinear regions due to losses in the steel stiffness and strength, are among the issues considered in this study. As an interesting finding, the beams protected by ordinary cement-based coating could sustain the fire exposure at least for 30 minutes in all cases. The mentioned time is increased by employing a new fire-retardant protection, which could prevent significant loss in the structure resistance against fire, even after 60 minutes of exposure to fire.

알칼리성 환경에서 부동태 피막 개선에 대한 양쪽성 이온 및 인산염 그룹을 갖는 염화물 이온의 역할 (Role of chloride ions with Zwitterions and phosphate groups on the improvement of the passive film in alkaline environment)

  • 트란득탄;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.43-44
    • /
    • 2022
  • In this study, the optimum amount of chloride ions is used to collaborate with hybrid corrosion inhibitor for carbon steel rebar treatment in simulated pore concrete (SCP) solution is discovered. The corrosion inhibition performance of hybrid inhibitors is carried on by open circuit potential (OCP), electrochemical impedance spectroscopy (EIS), and potentiodynamic polarization (PP). The highest corrosion inhibition resistance is found in case of LP-C2 after 240 h exposure. Surface studies including scanning electron microscopy (SEM), and atomic force microscopy (AFM) were used to figure out the surface morphology of the steel rebar treated with hybrid inhibitors in order to collaborate well with electrochemical studies. Anodic type inhibition action was confirmed by potentiodynamic polarization study.

  • PDF