• Title/Summary/Keyword: Passive monitoring

Search Result 223, Processing Time 0.028 seconds

A Study on Heating Energy Monitoring of a Rural Detached House Applying Passive House Design Components (패시브 하우스 디자인 요소를 적용한 농촌지역 단독주거건물의 난방에너지 모니터링 연구)

  • Cho, Kyung-Min;Lee, Tae-Goo;Han, Young-Hae
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.39-46
    • /
    • 2013
  • Recently, the field of construction is putting a variety of effort into reducing CO2, since global warming is being accelerated due to climate changes and the increase of greenhouse gas. For reduction of CO2 in the field of construction, it is required to make plans to cut down heating energy of buildings and especially, it is urgently needed to cut down energy of residential buildings in rural area where occupies the majority of consumption of petroleum-based energy sources. Therefore, this research compared and analyzed the actual energy consumption, by evaluating energy performance of a detached house applying passive house design components for reduction of energy. As the result, energy consumption showed remarkable differences, according to the operation of a heat recovery ventilation unit which is one of passive house design components, and building energy consumption displayed remarkable differences, too, depending on the difference of airtightness performance during building energy simulation conducted in process of design. Based on these results, the importance of airtightness performance of passive house was verified. The result of the actual measurement of energy consumption demonstrated that LNG was most economical amongst several heat resources yielded, on the basis of LPG source energy consumption measured within a certain period of time, and it was followed by kerosene. LPG was analyzed to have a low economic efficiency, when used for heating.

Performance Evaluation of Dynamic Bandwidth Allocation Algorithm for XG-PON with Traffic Monitoring (Traffic Monitoring 방식의 XG-PON 동적대역할당의 성능평가)

  • Han, Man Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.449-450
    • /
    • 2015
  • This paper describes performance evaluation results of a new dynamic bandwidth allocation algorithm for an XG-PON (10-Gbps-capable passive optical network) system without using an explicit request. An ONU (optical network unit) does not send its request to an OLT (optical line termination). The OLT monitors the upstream bandwidth usage of the ONU to estimate the request of the ONU.

  • PDF

Dynamic Bandwidth Allocation Algorithm of XG-PON using Traffic Monitoring (Traffic Monitoring 방식의 XG-PON 동적대역할당 방법)

  • Hong, Sung Hark;Han, Man Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.705-706
    • /
    • 2014
  • This paper proposes a new dynamic bandwidth allocation algorithm for an XG-PON (10-Gbps-capable passive optical network) system. In the XG-PON system, an ONU (optical network unit) does not explicitly send it request to an OLT (optical line termination). The OLT monitors the upstream bandwidth usage of the ONU to estimate the request of the ONU. Then the OLT performs a dynamic bandwidth allocation process based on the estimated requests.

  • PDF

Dynamic Bandwidth Allocation Algorithm of XG-PON using Traffic Monitoring (Traffic Monitoring을 이용한 XG-PON 동적대역할당 알고리즘)

  • Hong, Sung Hark;Han, Man Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.152-153
    • /
    • 2014
  • This paper proposes a new dynamic bandwidth allocation algorithm for an XG-PON (10-Gbps-capable passive optical network) system in which an ONU (optical network unit) does not explicitly send its request to an OLT (optical line termination). To estimate the request of the ONU, the OLT monitors the upstream bandwidth usage of the ONU and periodically allocates a probe slot to the ONU.

  • PDF

Calculation Method for the Concentration of Persistent Organic Pollutants (POPs) Collected by Passive Air Samplers (수동대기채취기를 이용한 잔류성유기오염물질의 농도산정)

  • Choi, Sung-Deuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.2
    • /
    • pp.217-227
    • /
    • 2013
  • Passive air samplers (PAS) have been developed since the early 2000s and widely used for the atmospheric monitoring of persistent organic pollutants (POPs). PAS are useful especially for the investigation of source-receptor relationship of POPs because they provide higher spatial resolution data. In Korea, however, only a few research groups have conducted POPs monitoring using PAS. One of the reasons for the limited application of PAS might be due to a complicated calculation method for air concentration. In this study, therefore, we introduced the principle of polyurethane foam (PUF)-PAS, which has been most widely used in the world, and provided an example of the calculation of air concentration of polycyclic aromatic hydrocarbons (PAHs). As all data tables and equations for this calculation were provided, this method can be used for the conversion of the amount of POPs (ng) in a PUF disk to air concentration ($ng/m^3$).

Characteristics of PAHs Absorbed on Pine Needles (소나무잎에 침착된 PAHs 특성)

  • Chun, Man-Young
    • Environmental Analysis Health and Toxicology
    • /
    • v.23 no.3
    • /
    • pp.213-220
    • /
    • 2008
  • The characteristics of PAHs accumulated on pine needles which were used as passive samplers of atmospheric POPs were studied. Atmospheric PAHs were accumulated on pine needles. The absorbed rate of PAHs was higher in gaseous state than in particulate and is not constant. The accumulation rate did not change too much among different classes of pine trees. Therefore young pine needles is better as a passive sampler of atmospheric PAHs for short monitoring period.

A Study of Health & Disaster Monitoring Measurement using Ubiquitous Active Communication Digital Datalogger System for Railway Structures (유비쿼터스 기반 통신의 철도구조물에 대한 재난감지용 능동형 데이터로거 시스템 연구)

  • Lee, Seong-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.470-475
    • /
    • 2011
  • The objective of this study is the developement health & disaster monitoring measurement using ubiquitous active communication digital datalogger system for monitoring measurement of railway construction sites. For the replacement of current passive data communication, ubiquitous active communication digital datalogger system is studied for the first time with in a country. Therefore data communication method and analyzing program of automatic measurement data is developed for the global positioning automatic digital datalogger system. The results of this study will be using both real time automatic monitoring measurement and health & disaster monitoring measurement of railway structures.

  • PDF

Development of a Passive Sampler using a Fluorescence Material for the Ambient Ozone (형광물질을 이용한 대기 중 오존 Passive Sampler의 개발)

  • 임봉빈;정의석;김선태
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.4
    • /
    • pp.483-491
    • /
    • 2004
  • The purpose of this study is to develop an ozone passive sampler and to evaluate its performance p-Acetamidophenol using as the reagent for ozone reacts specifically with the ambient ozone to produce a fluorescence material (p-acetamidopheonl dimer). The volume of absorbent solution and the extraction time determined at suitable conditions for measuring ozone were 100$\mu$L and 60 min, respectively. The changes of fluorescence were observed with incresing the storage period of passive samplers in ambient air. but the cool storage in a refrigerator did not remarkably influence the increase of fluorescence. The measurement for the precision oi the passive sampling was carried out with duplicate measurement of passive samplers. The intra-class correlation coefficients of passive samplers using dry and wet filters were 0.992 and 0.962, respectively The results from field validation tests indicated practical agreement (dry filter: r=0.963, wet filter: r=0.995) between the passive sampler and an UV photometric $O_3$ analyzer. The limit of quantification of ozone passive samplers with sampling time of 8 hr (wet filter) and 24 hr (dry filter) were 8.0 ppb and 2.7 ppb, respectively.