• 제목/요약/키워드: Passive components

검색결과 430건 처리시간 0.028초

SAFETY ANALYSIS OF INCREASE IN HEAT REMOVAL FROM REACTOR COOLANT SYSTEM WITH INADVERTENT OPERATION OF PASSIVE RESIDUAL HEAT REMOVAL AT NO-LOAD CONDITIONS

  • SHAO, GE;CAO, XUEWU
    • Nuclear Engineering and Technology
    • /
    • 제47권4호
    • /
    • pp.434-442
    • /
    • 2015
  • The advanced passive pressurized water reactor (PWR) is being constructed in China and the passive residual heat removal (PRHR) system was designed to remove the decay heat. During accident scenarios with increase of heat removal from the primary coolant system, the actuation of the PRHR will enhance the cooldown of the primary coolant system. There is a risk of power excursion during the cooldown of the primary coolant system. Therefore, it is necessary to analyze the thermal hydraulic behavior of the reactor coolant system (RCS) at this condition. The advanced passive PWR model, including major components in the RCS, is built by SCDAP/RELAP5 code. The thermal hydraulic behavior of the core is studied for two typical accident sequences with PRHR actuation to investigate the core cooling capability with conservative assumptions, a main steam line break (MSLB) event and inadvertent opening of a steam generator (SG) safety valve event. The results show that the core is ultimately shut down by the boric acid solution delivered by Core Makeup Tank (CMT) injections. The effects of CMT boric acid concentration and the activation delay time on accident consequences are analyzed for MSLB, which shows that there is no consequential damage to the fuel or reactor coolant system in the selected conditions.

Temperature, Current, and Voltage Dependences of Junction Failure in PIN Photodiodes

  • Park, Sahng-Gi;Sim, Eun-Deok;Park, Jeong-Woo;Sim, Jae-Sik;Song, Hyun-Woo;Oh, Su-Hwan;Baek, Yong-Soon
    • ETRI Journal
    • /
    • 제28권5호
    • /
    • pp.555-560
    • /
    • 2006
  • A PIN photodiode having a low dark current of 1.35 nA and a high external quantum efficiency of 95.3% fabricated for a passive optical network receiver. As the current was increased under a high voltage of 38 V and a temperature of $190^{\circ}C$, it was observed that there is a threshold current at 11 mA which induces a junction failure. Experimental data suggest that the junction failure occurs due to the crystal breaking at the end facet as a result of thermal heat or energetic carriers. This threshold behavior of junction failure is a valuable observation for the safe treatment of photodiodes. As long as the current is limited below the threshold currents, we have not observed failure events of our photodiodes.

  • PDF

공동주택의 에너지 자립을 위한 핵심요소기술의 에너지 성능평가 (Energy Performance Evaluation of Zero Energy Technologies for Zero Energy Multi-House)

  • 윤종호;김병수
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.161-167
    • /
    • 2007
  • Zero Energy Multi-House(ZeMH) signifies a residential building which can be self sufficient with just new and renewable energy resources without the aid of any existing fossil fuel. For success of ZeMH, various innovative energy technologies Including passive and active systems should be well integrated with a systematic design approach. The first step for ZeMH is definitely to minimize the conventional heating and cooling loads over 50% with major energy conservation measure and passive solar features which are mainly related to building design components such as super-insulation, super window, including infiltration and ventilation issues. The purpose of this study is to analyze the thermal effect of various building design components in the early design of ZeMH. The process of the study is presented in the following. 1) selection reference model for simulation 2) verification of reference model with computer simulation program(ESP-r 9.0). 3) analysis of effect according to insulation-thickness, kinds of windows, rate of infiltration. and The simulation results indicate that almost 50% savings of conventional heating load in multi-house can be achieved with the optimum design of building components such as super insulation, super window, infiltration, ventilation.

Anti-allergic and Anti-inflammatory Actions of Cimicifuga heracleifolia: Partial Purification of Active Components

  • Kim, Young-Ran;Park, Soo-Hyung;Kim, Kyeong-Man
    • Biomolecules & Therapeutics
    • /
    • 제2권2호
    • /
    • pp.149-154
    • /
    • 1994
  • Anti-allergic and anti-inflammatory actions of the water extract from Cimicifuga heracleifolia were evaluated in mice and rats. Several criteria were employed to assess the anti-allergic and anti-inflammatory actions of Cimicifuga heracleifolia, such as hyaluronidase activity, mediators-induced vascular permeability changes, 48 hour homologous passive cutaneous anaphylaxis (PCA) histamine release from mast cells, and the carrageenan-induced rat paw edema. To further characterize the active components, the water extract was either extracted with organic solvent or fractionated according to molecular weight, and each fraction was tested for some of anti-allergic parameters. Hyaluronidase activities, both in activating and in activated states, were significantly inhibited by the water extract of Cimicifuga heracleifolia and by some of its subfractions, molecular weight less than 1,000. The water extracts (50~400 mg/kg) significantly inhibited 48 hr homologous PCA and vascular permeability changes induced by chemical mediators (histamine, serotonin, and leukotriene $C_4$) in mice. In the case of histamine-induced vascular permeability changes, more extensive studies were conducted; water extract was either fractionated according to molecular weight or extracted with butanol. Anti-histamine actions were observed only from the water layer, and these active components were of the molecular weight less than 1,000. These anti-allergic actions were observed mainly from mice than from rats. On the other hand, anti-inflammatory actions of the water extract from Cimicifuga heracleifolia were significant in rats.

  • PDF

해상 무선통신소자의 응용을 위한 RFIC/MMIC용 소형화된 능동형 90$^{\circ}$ 위상 분배기의 설계 (Design of miniaturized active 90$^{\circ}$ phase divider on RFIC/MMIC for application to maritime wireless communication components)

  • 박영배;윤영
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.406-411
    • /
    • 2005
  • In this paper, we propose an active 90$^{\circ}$ phase divider for application to MMIC. Because of their very large size, conventional passive 90$^{\circ}$ dividers can't be integrated on MMIC. Therefore, highly miniaturized 90$^{\circ}$ dividers are required for a development of highly integrated MMIC. For this reason, active 90$^{\circ}$ divider is indispensable because active phase divider is much smaller than conventional passive dividers, and it can be integrated on MMIC. In this work, we developed active 90$^{\circ}$ divider with emitter inductor, and it was employed for the operation of the balanced mixer in order to verify the performance of the active 90$^{\circ}$ divider. According to the results, it was found that the active 90$^{\circ}$ divider exhibited good RF performances comparable to conventional passive power dividers.

  • PDF

단상 전원의 고조파 제거용 500VA급 Hybrid 필터 개발 (500VA Hybrid filter development for harmonic elimination of a single phase power)

  • 박종연;이후찬;이봉진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.249-253
    • /
    • 2006
  • Because of the high cost for the active power filter, passive filters have been widly used to absorb harmonic currents of nonlinear loads and can also improve the power factor. They are not often optimal filters because the passive filters are designed with the fixed load conditions. In this paper we proposed the method which only the necessary harmonic filters are operated by detecting the various harmonic current components. By the experimental results using the proposed system for the 500VA rectifier load, we concluded that the researched hybrid filter is cost effective and the performance is better than the passive filter.

  • PDF

TEC를 이용한 인공위성 열제어 시스템의 특성 고찰

  • 김귀순;이수상;장영근;최해진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 1999년도 제12회 학술강연회논문집
    • /
    • pp.24-24
    • /
    • 1999
  • This study addresses the effectiveness of TEC(Thermoelectric cooler) application for spacecraft thermal control. The required radiator area and power consumption characteristics of active thermal control using TEC are compared with the passive control at BOL and EOL through unsteady thermal analyses by calculating external heat fluxes. When the component operating temperature is low enough in TEC active control, the required radiator area can be smaller than the passive thermal control. TEC also needs less power consumption than the passive control under the condition that the temperature of cooling pars is low enough and/or the design temperature margin of the components is narrow enough.

  • PDF

Performance Evaluation of Bidirectional Optical Amplifiers for Amplified Passive Optical Network Based on Broadband Light Source Seeded Optical Sources

  • Kang, Byoung-Wook;Kim, Chul-Han
    • Journal of the Optical Society of Korea
    • /
    • 제15권1호
    • /
    • pp.4-8
    • /
    • 2011
  • We have evaluated the performances of bidirectional optical amplifiers which were suited for the cost-effective implementation of amplified bidirectional passive optical networks (PONs). First, we measured the maximum gains of two simple bidirectional optical amplifiers implemented without using any optical components for the suppression of reflected signals. From the results, the maximum gains of two simple bidirectional amplifiers with a broadband light source (BLS) seeded optical source were limited to be 27 dB due to the reflection-induced in-band crosstalk, when the reflectance coefficients were measured to be -33 dB in both directions. Then, we have also implemented a bidirectional optical amplifier with two band splitters for the amplified bidirectional PON where the two different wavelength bands were allocated to the downstream and upstream signals transmission. In our measurement, we confirmed that the maximum gain of bidirectional optical amplifier with two band splitters could be increased to more than 30 dB owing to the efficient suppression of in-band crosstalk.

전력변환장치의 고조파 영향 및 연구동향 (Harmonic Effects and Consideration in Power Converter and Component)

  • 조성준;김태완;우명호;서광덕
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.467-470
    • /
    • 2001
  • Power electronic converters generate the harmonic voltage and current, and these harmonics have the harmful effects on the various components. For example, passive components such as capacitor and inductor, transformer, motor and other components are mainly affected in the power electronic system. Thus, the design and manufacturing of the power converters, which have the harmonic-free or mitigation strategies, are required. In particular, the lifetime and durability of these components are main requirement for enhancing the overall stability of the system. So, in this paper, the harmonics-related problems to the neighbouring components and mitigation research trends are presented.

  • PDF

인버터 에어컨용 능동역률보상회로 설계 및 효과 (Design and Effects of Power Factor Correction Circuit for Inverter Air-Conditioner)

  • 박병욱;권경안
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.27-30
    • /
    • 1998
  • In this paper, the inverter air-conditioner with Power Factor Correction(PFC) circuit is Presented for obtaining the good system efficiency and cost merit compared with the conventional inverter air-conditioner. The detailed design procedures for getting the optimal passive components are implemented. Through the simulation and experimental results, it is shown that the system efficiency can be improved. Using the designed components, the prototype system is builted and tested to verify the additional good performances of the proposed circuit.

  • PDF