• Title/Summary/Keyword: Passive air sampling

Search Result 39, Processing Time 0.021 seconds

Seasonal Variation of Atmospheric Polycyclic Aromatic Hydrocarbons (PAHs) on Anmyeon Island (안면도에서 대기 중 가스상 PAHs의 계절적 변동)

  • An, Joon-Geon;Yim, Un-Hyuk;Shim, Won-Joon;Kim, Gi-Beum;Kim, Seung-Kyu;Yi, Hi-Il
    • Ocean and Polar Research
    • /
    • v.31 no.2
    • /
    • pp.189-198
    • /
    • 2009
  • Passive air samplers with polyurethane foam (PUF) disks were employed to determine seasonal gas phase variation of polycyclic aromatic hydrocarbons (PAHs) in ambient air on Anmyeon island from March 2007 to January 2008. Sum of 13 PAHs ranged between $3.5\;ng/m^3$ and $27.6\;ng/m^3$. Total PAHs during the heating season was 6.2 times higher than non-heating season. The dominant PAHs components during sampling periods were low and middle molecular weight PAHs including phenanthrene, fluoranthene, pyrene and chrysene. Gas exchange fluxes of PAHs across the air-water interface of the Yellow Sea were calculated using a modified two-film exchange model. PAHs fluxes ranged from $196\;ng/m^2/d$ net volatilization during summer to $3830\;ng/m^2/d$ net absorption during winter. Passive air sampler provides a convenient and cost-effective tool for measuring averaged gas phase PAHs, which was successfully used for calculation of gas exchange flux of PAHs in the Yellow Sea.

Smoke Density and Operation of Fire Detector Influenced by Air Stream (기류순환이 연기농도와 감지기 작동에 미치는 영향)

  • 이복영;이병곤
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.28-32
    • /
    • 2002
  • The performance based design in fire detection system, the effect of high airflow and dilution of smoke produced in any fire situation serve to increase the response time of point-type smoke detectors. This study investigated the smoke density of ceiling, under the air stream and in normal status when fire type is smoldering fires. The result of study, smoke generated in the fire was swept away from nearby spot type smoke detector which failed to actuate because dispersed in diluted form around the room. The concept of performance based design in fire detection system of protected area influenced by high airflow provided the need of active fire detection system such as air sampling smoke detection system.

Comparison of Active and Passive Sampling Methods for Formaldehyde Concentrations Among Workplaces in Some Plywood Industries (능동포집과 확산포집법에 의한 일부합판제조업의 공정별 포름알데하이드 농도 비교)

  • Jang, Mi;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.17-27
    • /
    • 1996
  • This study was designed to survey exposure levels of formaldehyde among workplaces in some plywood industries and to compare three sampling methods including the impinger method(IM, NIOSH method No. 3500), the solid sorbent tube method(SS, NIOSH method No. 2541), and the passive bubbler monitor method(PB, SKC). The survey was conducted in seven particle board manufacturing factories, two resin manufacturing factories and two plywood manufacturing factories in Incheon area during the period from March 6 to April 20, 1995. The workplaces included were the hot/cold press, the roller/spreader, the soaking/drying, and the reaction/mixing areas. The results were as follows; 1. The average(GM, GSD) concentrations of formaldehyde by sampling methods were 0.11(4.43) ppm by IM, 0.27(2.03) ppm by SS, and 0.29(2.04) ppm by PB, respectively. The concentrations by 1M method were statistically very significantly lower than those of SS and PB methods, particularly at low air borne concentrations of formaldehyde (p<0.001). 2. The area average concentrations of formaldehyde by workplaces measured with PB bubblers were 0.23(2.08) ppm from the press, 0.23(1.77) ppm from the spreader, 0.24(1.51) ppm from the soaking, and 0.46(1.96) ppm from the reaction areas, respectively. The personal average concentrations of formaldehyde by workplaces measured with PB bubblers were 0.30(1.77) ppm from the press, 0.33(1.54) ppm from the spreader, 0.36(1.46) ppm from the soaking, and 0.84(1.19) ppm from the reaction areas, respectively. 3. No statistically significant differences of formaldehyde concentrations among workplaces except the reaction area(p<0.001) were found. 4. Formaldehyde concentrations from personal samples were higher than those of from area sam pies in all workplaces studied. But no statistically significant differences of formaldehyde concentrations both area and personal samples were found. In conclusion, this study found that although formaldehyde concentrations in some plywood industries in Incheon area were below the regulatory limit of 1 ppm, they were over the limits recommended by NIOSH and ACGIH. This study also suggests that the impinger method may underestimate true formaldehyde concentrations. It implies that there will be more workplaces not meeting current regulatory limit if either the solid sorbent or passive bubbler methods were used instead of the impinger method. It is suggested that passive monitors will be a reasonable alternative for area and personal sampling of formaldehyde if the accuracy and validity of passive monitors be verified before use.

  • PDF

A Study on Organic Solvent Measurement Using Diffusive Sampler (확산포집기를 이용한 공기 중 유기용제 포집에 관한 연구)

  • Park, Mi Jin;Yoon, Chung Sik;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.208-223
    • /
    • 1994
  • The purpose of this study was to evaluate the efficiency of diffusive(or passive) sampler in measuring airbone organic solvents. Diffusive samplers are generally simple in construction and do not require power for operation. The efficiency of the diffusive samplers has not sufficiently been investigated in Korea. Three types of samplers were studied in this study. The sampling and analytical results by passive samplers were compared with results by charcoal tube method recommended by NIOSH(National Institute for Occupational Safty and Health). The following characteristics are identified and studied as critical to the performance passive monitors; recovery, reverse diffusion, storage stability, accuracy and precision, face velocity and humidity, n-Hexane, TCE(trichloroethylene) and toluene were used as test vapors. A dynamic vapor exposure system consisting of organic vapor generator and sampling chamber for evaluating diffusive samplers are made. The results of the study are summarized as follows. 1. NIOSH recommands that the overall accuracy of a sampling method in the range of 0.5 to 2.0 times the occupational health standard should be ${\pm}25$ percent for 95 percent confidence level. Among three types of diffusive samplers, sampler A has permeation membrane and samplers Band C have diffusive areas, samplers A and B met the criterion that overall accuracy for 95% confidence level of the samplers were within ${\pm}25$ percent of the reference value. Sampler C had overall accuracy ${\pm}9.6%$ and ${\pm}11.8%$ in hexane and TCE, respectively. The concentration of toluene was overestimated in sampler C with overall accuracy of ${\pm}43.9%$. 2. The desorption efficiencies of diffusive samplers were 96-107%. 3. There was no significant sampe loss during four weeks of storage both with and without refrigeration. 4. There was no significant reverse diffusion, when the samplers were exposure to clean air for 2 hours after sampling for 2 hours at the level of 2 TLY. 5. In case of 8 hours sampling, relative differences(RD) of concentrations between charcoal tube method and diffusive method were 15-39%, 13-46%, and 4-35% for sampler A, B and C, respectively. The performance was poor in 8 hours sampling for multiple substance monitors. 6. At high velocity(100 cm/sec), samplers B and C overestimated the concentrations of organic vapors, and sampler A with permeation membrance gave better results. 7. At 80% relative humidity, samplers showed no siginificant effect. Low humidity also did not affect the diffusive samplers.

  • PDF

Development and Evaluation of a Carbon Dioxide Diffusive Sampling Method using Barium Hydroxide (수산화바륨을 이용한 이산화탄소 확산측정법의 개발 및 평가)

  • Yim, Bongbeen
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.1
    • /
    • pp.56-63
    • /
    • 2013
  • This study was aimed at developing and evaluating a diffusive sampling method using a barium hydroxide solution as an absorbent for measuring carbon dioxide ($CO_2$) in ambient air. The collected $CO_2$ concentration was calculated by the change of conductivity resulted in the reaction of $CO_3{^{2-}}$ and $Ba^{2+}$ in aqueous solution. The sampling rate for the diffusive sampler was determined 0.218 mL/min, as obtained from the slope of the linear correlation between the $CO_2$ mass collected by the diffusive sampler and the time-weighted $CO_2$ concentration with the active sampling method. The unexposed blank sampler sealed in aluminium foil-polyethylene laminated packets has remained stable during at least one-month storage period. A good correlation was observed between the diffusive sampler and active sampler with a coefficient of determination of 0.956. This diffusive sampler would be suitable for the indoor $CO_2$ concentration monitoring.

A Review on the Sampling and Analytical Methods for Ammonia in Air

  • Das, Piw;Kim, K.H.;Sa, J.H.;Kim, J.C.;Lee, S.R.;Jeon, E.C.
    • Journal of the Korean earth science society
    • /
    • v.28 no.5
    • /
    • pp.572-584
    • /
    • 2007
  • The quantification of ammonia concentrations has received a lot of scientific attention. Numerous devices for the quantification of $NH_3$ in the ambient air have been developed to provide more technical possibilities for research in abating $NH_3$ emission from various source processes. For the proper quantification of $NH_3$, a number of sampling methods have been discussed by grouping them into different categories based on the principle of functioning. In general, active samplers employ pumps to draw air in, while passive samplers are exposed to air over a certain period of time to obtain integrated signature of $NH_3$. In case of the former, impingers and absorption flasks can be employed simultaneously with suitable absorbents to capture $NH_3$ passing through them. The methods of analysis include both in-situ and laboratory determination. In the laboratory, colorimetric or ion chromatographic methods are generally used for its quantification. In the field, a number of real time analyzers have been proven to be useful. These real time analyzers can be grouped according to their principle of operation. These analyzers may use the principle of spectroscopy (e.g. DOAS), photoacousticics (e.g. photoacoustic monitor) or Chemiluminescence ($NO_x$ analyzer). The automated annular denuder sampling system with on-line analyzer is also suitable for continuous monitoring of ammonia in air.

월성 원전 주딘의 대기중 $^l4C$ 포집기술

  • 강덕원;김언희
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.671-676
    • /
    • 1998
  • 방사성 $\beta$핵종 중의 하나인 $^{14}$ C은 중수로에서 상대적으로 많이 방출된다. 본 연구에서는 국내 유일의 중수로 원전인 월성 원자력발전소에서 배기구를 통해 환경으로 방출된 $^{14}$ C을 감시하기 위한 두 가지 타입의 대기시료 포집기술을 개발하였다. 하나는 전원을 이용하는 능동시료포집법(active air sampling)이며, 다른 하나는 전원을 사용하지 않는 수동시료포집법(passive air sampling)이다. 시료분석의 재현성 측면에서는 능동시료포집법이 보다 나은 것으로 알려져 있으나 시료채취 장소의 제한성 등으로 인해 최근에 들어와 수동시료포집법의 사용을 선호하고 있다. 본 연구를 통해 두가지 시료 채취법에 대한 측정오차의 신뢰성을 검증하기 위해 동위원소 분별효과를 비교 평가해 본 결과, 측정상의 오차가 약 2% 정도로 나타나 시료채취가 간단한 수동시료포집법의 사용타당성 및 활용 가능성을 입증하였다.

  • PDF

A Study on the Characteristics of Ambient Volatile Organic Compounds in Gimhae (김해 지역 대기 중 휘발성유기화합물 특성연구)

  • Bong, Sang-Hun;Jeong, Seong-Wook;Park, Heung-Jai;Kim, Woo-Seong;Kim, Sung-Hun
    • Journal of Environmental Science International
    • /
    • v.17 no.8
    • /
    • pp.871-878
    • /
    • 2008
  • In this study, we measured volatile organic compounds in Gimhae city, South Korea. We selected twenty site and measured volatile organic compounds in ambient air by passive sampler when at sampling intervals of two month from April to December 2005. Passive sampler was exposed for fifteen day in ambient air. And samples were analyzed by GC/FID for volatile organic compounds. The results of each measured functional zone, mean concentration of each compound measured were generally higher the industrial complex area and traffic pollution area than residental area. Each area showed similar pattern for the observation period. concentration of measured each compound were the following order: winter > fall > spring > summer.

The Study on the Effects of Air Pollution on the Material Damages in Northeast Asia

  • Kim, Sun-Tae;Yasuaki Maeda
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.E2
    • /
    • pp.51-61
    • /
    • 2003
  • The material exposure tests have been carried out since 1993 to evaluate the relationship between air pollution and material corrosion with the cooperation of the researchers in Japan, China, and Korea. The test pieces such as bronze, copper, marble, and carbon steel have been exposed under both unsheltered and rain-sheltered outdoor condition separately at 18 sampling sites in East Asia. At the same time, the concentration of SO$_2$ and NO$_2$ has been measured simultaneously with passive sampler. The meteorological data were collected from the AWS (Auto-mated weather station) In each country and chemical compositions of wet deposition were also analyzed by the bulk sampling of rainfall every month. As the results, it was found that the corrosion rates of test pieces in the ambient air were appeared to be in the order of carbon steel > marble > bronze copper. The corrosion rates of test pieces in the unsheltered outdoor condition were 2.34 to 5.88 times larger than those in rain-sheltered condition. It was also found that the corrosion rate in the heavy polluted area in China was the highest, and the corrosion rates of the metal pieces were generally proportional to SO$_2$ concentration. Between two sites in Korea, the test pieces at Daegu site showed higher corrosion rates that would be due to the higher SO$_2$ concentration.

Nitrogen Dioxide Measurement with Diffusive Passive Samplers at the Curbside Points in Daejeon (확산측정기를 이용한 대전시 도로변에서의 이산화질소 측정)

  • Yim, Bong-Been;Kim, Sun-Tae;Yang, Heung-Mo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.143-152
    • /
    • 2008
  • This study investigates the variation and spatial distribution of nitrogen dioxide($NO_2$) concentrations measured with passive diffusive samplers at 40 curbside points in Daejeon. Average $NO_2$ concentration was $39.8{\pm}18.0\;ppb$ (n=1,127) and the significant difference in concentrations by regional groups (Dong-gu, Jung-gu, Seo-gu, Daedeok-gu, Yuseong-gu) was not observed. The frequency distribution of $NO_2$ concentration was found to be a normal distribution with the high frequency in the concentration range of 30 to 40 ppb (20 to 25%). Average $NO_2$ concentration measured during the rainy periods was lower than that measured during the non-rainy periods and the decrease of concentration by rainfall was about 16% (7 ppb). The variation of $NO_2$ concentrations measured by passive diffusive samplers during the sampling period was similar to that continuously measured at the air quality monitoring station.