• 제목/요약/키워드: Passive Ventilation System

검색결과 43건 처리시간 0.028초

Semi-active storey isolation system employing MRE isolator with parameter identification based on NSGA-II with DCD

  • Gu, Xiaoyu;Yu, Yang;Li, Jianchun;Li, Yancheng;Alamdari, Mehrisadat Makki
    • Earthquakes and Structures
    • /
    • 제11권6호
    • /
    • pp.1101-1121
    • /
    • 2016
  • Base isolation, one of the popular seismic protection approaches proven to be effective in practical applications, has been widely applied worldwide during the past few decades. As the techniques mature, it has been recognised that, the biggest issue faced in base isolation technique is the challenge of great base displacement demand, which leads to the potential of overturning of the structure, instability and permanent damage of the isolators. Meanwhile, drain, ventilation and regular maintenance at the base isolation level are quite difficult and rather time- and fund- consuming, especially in the highly populated areas. To address these challenges, a number of efforts have been dedicated to propose new isolation systems, including segmental building, additional storey isolation (ASI) and mid-storey isolation system, etc. However, such techniques have their own flaws, among which whipping effect is the most obvious one. Moreover, due to their inherent passive nature, all these techniques, including traditional base isolation system, show incapability to cope with the unpredictable and diverse nature of earthquakes. The solution for the aforementioned challenge is to develop an innovative vibration isolation system to realise variable structural stiffness to maximise the adaptability and controllability of the system. Recently, advances on the development of an adaptive magneto-rheological elastomer (MRE) vibration isolator has enlightened the development of adaptive base isolation systems due to its ability to alter stiffness by changing applied electrical current. In this study, an innovative semi-active storey isolation system inserting such novel MRE isolators between each floor is proposed. The stiffness of each level in the proposed isolation system can thus be changed according to characteristics of the MRE isolators. Non-dominated sorting genetic algorithm type II (NSGA-II) with dynamic crowding distance (DCD) is utilised for the optimisation of the parameters at isolation level in the system. Extensive comparative simulation studies have been conducted using 5-storey benchmark model to evaluate the performance of the proposed isolation system under different earthquake excitations. Simulation results compare the seismic responses of bare building, building with passive controlled MRE base isolation system, building with passive-controlled MRE storey isolation system and building with optimised storey isolation system.

작업장에서의 유해 유기용제 폭로에 관한 연구 (Investigation of toxic organic solvent exposure in work places)

  • 조영민;강상완;오종민
    • 환경영향평가
    • /
    • 제9권1호
    • /
    • pp.75-86
    • /
    • 2000
  • The purpose of this work was to document the conditions regarding organic solvent exposure to the workers in paint industry. Air concentrations of organic solvents were measured by passive personal samplers and analyzed by a gas chromatography. Urine samples for hippuric test were also taken from 330 workers who have worked at seven domestic factories for more than two years. Amongst 25 organic elements detected in the indoor environment of working places, toluene was the most common element, and methanol showed the highest mean concentration(18.2ppm). A few elements including methylethyl ketone and toluene partially exceeded the Korean Permissible Exposure Limit. A lack of environmental facilities such as exhaust ventilation, automatic cleaning system, and personal safety devices at present work plaus brings about various occupational diseases.

  • PDF

3L House의 설계, 시공 및 평가 (The Technology Applied 3 Liter House, Super Energy Saving Building)

  • 박선효;박용승;원종서
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.814-819
    • /
    • 2006
  • This research is on the design and introducing of integrated thermal performance of super energy saying building, called 3 Liter house which can be sustained with 3 liter oil(kerosene) per $yr.m^2$. 3 liter houses(Passive houses) offer extended living comfort with only 15 to 20% of the space heating demand of conventional new building. To achieve this purpose, the efficiency of building components is improved, such as walls, windows or ventilation system and the construction technology is improved, such as the prevention of thermal bridge and the air tightness. The fuel cell is used as alternative energy. Energy consumption of 3L house is 2.08 [liter/$yr.m^2$] in monitoring result of $2006/2/1{\sim}2/7$ and ACH50 is 0.67 in result of Blow Door Test, therefore 3L House is well- insulated and well- airtighted house.

  • PDF

도시철도 역사 신재생에너지 활용을 위한 멀티레벨 인버터 개발 (Multilevel Inverter Development to Utilize Renewable Energy in Urban Railway Station)

  • 신승권;김형철;정호성;박종영;현병수
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.324-330
    • /
    • 2015
  • Energy Saving Methods in existing railway vehicle are considered by active approach such as regenerative energy storage and utilization, eco driving, etc. On the other hands, energy saving measures in railway station are operated by passive method such as reduction of operating time in ventilation system, cooing system and power equipment. To reduce energy and for independence in railway system, it requires an active energy saving measures. It needs to its own power source besides the power source of electric supply company such as renewable energy and regenerative energy and take the advantage of power storage system and stored power are used in optimum time. This paper deal with 3-level NPC inverter and T-type NPC inverter that used in various multi-level topology applicable to the railway system.

에코센터의 생태건축기술에 관한 연구 - 건축재료와 태양에너지활용시스템을 중심으로 - (A Study on the Eco-Tecnique of EcoCenter - Focused on the Building Material and Solar System -)

  • 최영호;심우갑
    • KIEAE Journal
    • /
    • 제4권2호
    • /
    • pp.65-72
    • /
    • 2004
  • Ecological architecture enables people to recycle and reuse architectural resources within the category of ecosystem and also to minimize the effect on environment in a whole process, including architectural planning, usage and exhaustion to use sustainable energies. Rammed earth wall construction method utilized in EcoCenter located in Crystalwaters ecological village in Austrailia is a good example, which maximizes its advantages and also covers its limits to use soil and wood as structural resources. In a case of wood, they used non-treated timber to minimize environmental load and utilized used materials in openings. In the roofs, aluminum coated steel which is plated with zinc collects rain effectively even though it is not regenerable. Nontoxic finishes and insulation in floor and ceiling with used papers are able to minimize its environmental load. Solar energy system applied in EcoCenter enables them to market extra energy with electricity companies as well as support needs of its own buildings to utilize photovoltaic panel system with PV panels. Passive solar system is planned effectively in heating and cooling to apply regenerative walls in a use of rammed earth wall construction and natural ventilation systems through openings.

Prismatic Solar Hybrid Collector 시스템의 에너지 성능 평가에 관한 연구 (Energy Performance Assessment Study of Prismatic Solar Hybrid Collector System)

  • 박준언;김기세;이의준;정모
    • 한국태양에너지학회 논문집
    • /
    • 제23권2호
    • /
    • pp.51-58
    • /
    • 2003
  • PSHC(Prismatic Solar Hybrid Collector) is a passive solar system composed of prismatic acrly glazing, glazing and ventilating fan. This PSHC system is applied to effectively reduce heating ventilation load as well as lighting load. But so far no method appraising thermal performance of this PSHC system has been developed yet. To assess thermal performance of the PSHC system, a prototype PSHC experimental facility and TRNSYS subroutine type-205 model have been developed in Korea Institute of Energy Research (KIER). The results indicated that l)TRNSYS empirical model of PSHC has been properly modeled with actual performance data, 2)a more reliable source of weather data such as NASA and KIER weather station have been also obtained, and therefore, 3)the annual energy performance of PSHC could be assessed based on this proposed TRNSYS model.

급성 폐손상 환자에서 Adaptive Support Ventilation 적용 시 호흡지표의 양상 (Evaluation of Respiratory Parameters in Patients with Acute Lung Injury Receiving Adaptive Support Ventilation)

  • 이규성;정우영;정윤정;박주헌;신승수;황성철;박광주
    • Tuberculosis and Respiratory Diseases
    • /
    • 제70권1호
    • /
    • pp.36-42
    • /
    • 2011
  • Background: Adaptive support ventilation (ASV), an automated closed-loop ventilation mode, adapts to the mechanical characteristics of the respiratory system by continuous measurement and adjustment of the respiratory parameters. The adequacy of ASV was evaluated in the patients with acute lung injury (ALI). Methods: A total of 36 patients (19 normal lungs and 17 ALIs) were enrolled. The patients' breathing patterns and respiratory mechanics parameters were recorded under the passive ventilation using the ASV mode. Results: The ALI patients showed lower tidal volumes and higher respiratory rates (RR) compared to patients with normal lungs ($7.1{\pm}0.9$ mL/kg vs. $8.6{\pm}1.3$ mL/kg IBW; $19.7{\pm}4.8$ b/min vs. $14.6{\pm}4.6$ b/min; p<0.05, respectively). The expiratory time constant (RCe) was lower in ALI patients than in those with normal lungs, and the expiratory time/RCe was maintained above 3 in both groups. In all patients, RR was correlated with RCe and peak inspiratory flow ($r_s$=-0.40; $r_s$=0.43; p<0.05, respectively). In ALI patients, significant correlations were found between RR and RCe ($r_s$=-0.76, p<0.01), peak inspiratory flow and RR ($r_s$=-0.53, p<0.05), and RCe and peak inspiratory flow ($r_s$=-0.53, p<0.05). Conclusion: ASV was found to operate adequately according to the respiratory mechanical characteristics in the ALI patients. Discrepancies with the ARDS Network recommendations, such as a somewhat higher tidal volume, have yet to be addressed in further studies.

Passive Sampler를 이용한 유물 전시관내 폼알데하이드 농도 모니터링 (Monitoring of Formaldehyde Concentration in Exhibition Hall Using Passive Sampler)

  • 이선명;임보아;김서진
    • 보존과학회지
    • /
    • 제33권5호
    • /
    • pp.319-329
    • /
    • 2017
  • 이 연구에서는 Passive sampler를 이용하여 연구대상으로 선정된 2곳의 유물 전시관 내부의 폼알데하이드 농도를 2012년 5월부터 2013년 4월까지 1년간 공간별로 모니터링 하였다. 이 결과, 유물 전시관 내부의 폼알데하이드 농도는 외기에 비해 5배~36배 이상 높은 수치를 나타냈다. 각 전시실과 진열장 내부는 오염원, 공기조화설비, 환경관리에 따라 농도 수준을 달리하였다. 유물 전시관 내 폼알데하이드 농도 수준을 주시험법에 준하여 보정한 결과, 대부분이 환경부의 실내공기질 관리법에서 고시하는 전시실 유지기준($100{\mu}g/m^3$) 뿐만 아니라 일본 국립동경박물관에서 권고하는 문화재 보존환경 기준(약 $50{\mu}g/m^3$)을 모두 초과하였다. 전시실과 진열장 내 폼알데하이드의 농도는 모두 여름>가을>봄>겨울 순으로 높았으며 온 습도가 높은 여름철에 농도 방출량이 증가하였다. 온 습도환경 변화에 따른 폼알데하이드의 농도는 모두 양의 상관관계를 나타냈다. 온도의 경우 $R^2$값이 0.8~0.9의 범위로 폼알데하이드 농도가 습도에 비해 온도에 대한 의존 경향이 큰 것을 알 수 있다. 유물 전시관 내 폼알데하이드 방출 특성 분석은 실내공기질을 개선하는데 기초자료로 활용될 수 있을 것이다.

대학 네일아트 실습 중 발생하는 휘발성 유기화합물의 공기 중 농도 평가 (Evaluation of Airborne Volatile Organic Compounds Concentrations During Nail Art Practicing for College Students)

  • 박윤경;최인자;최혜영;안재경;최상준;김수진;김현서
    • 한국산업보건학회지
    • /
    • 제29권4호
    • /
    • pp.452-463
    • /
    • 2019
  • Objectives: The purpose of this study is to evaluate airborne concentrations of volatile organic compounds(VOCs) during nail art practice by college students. Methods: Personal samples for students were measured using passive samplers(OVM 3500) during three kinds of practice, including polish nail, gel nail and acrylic French sculpture at two universities located in Gyeongsangbuk-do Province. We also monitored area concentrations using active samplers and real-time total VOC monitors(ppbRAE 3000). All samples were analyzed with a gas chromatography flame ionized detector. Statistical analysis for monitored data were conducted using a web-based Bayesian toolkit, EXPOSTATS(www.expostats.ca). Results: Twenty-four personal samples and ten area samples were collected and five chemicals(acetone, butyl acetate, ethyl acetate, ethyl methacrylate(EMA) and methyl methacrylate(MMA)) were detected. Acetone was detected in all personal samples and ranged from 2.58 ppm to 50.3 ppm. EMA was detected in all personal and area samples with a maximum concentration of 9.78 ppm during acrylic French sculpture. Personal exposure levels to acetone, butyl acetate and mixtures were significantly higher with high occupant density (p<0.05). Geometric mean (GM) concentrations of 3.61 ppm for EMA personal samples were significantly higher than that of area samples, 1.5 ppm (p<0.05). Since there was no local ventilation, total VOC concentration continued to increase as the practice progressed. Conclusions: In order to minimize VOCs exposure for trainees, it is necessary to introduce a local ventilation system and maintain adequate occupant density.

투명단열재가 적용된 축열벽 시스템의 최적구성 선정에 관한 연구 (A study on the Optimum Design Configuration of Passive Solar TI-wall system)

  • 김병수;윤종호;윤용진;백남춘
    • KIEAE Journal
    • /
    • 제3권2호
    • /
    • pp.37-44
    • /
    • 2003
  • The aim of this study was to analyze the thermal performance through Test-Cell of TI-wall in domestic climate. This study was carried out as follows: 1) The TI-wall was studied for ability to reduce heat loss through the building envelope and analyzed to TIM properties. 2) Test models of TI-wall were designed through the investigation of previous paper and work, measured for winter and spring, and the thermal effects were analyzed. The type of the TIM used in test model is small-celled(diameter 4mm and thickness 50mm) capillary and cement brick(density $1500kg/m^3$) was used by thermal mass. 3) Test-cell of TI-wall was calibrated from measured data and the dynamic simulation program ESP-r 9.0. In these simulations, the measured climate conditions of TaeJon were used as outdoor conditions, and the simulation model of Test-cell was developed. 4) The sensitivity analysis is executed in various aspects with standard weather files and ESP-r 9.0, and then most suitable system of TI-wall are predicted. Finally, The suitable system of TI-wall was analysed according to sizes of air gap, kinds, thickness, and the surface absorption of therm wall. The result is following. In TI-wall, Concrete is better than cement brick, at that time the surface absorption is 95%, and the most efficient thickness is 250mm. As smaller of a air gap, as reducer of convection heat loss, it is efficient for heating energy. However, ensuring of a air gap at least more than 50mm is desirable for natural ventilation in Summer.