• Title/Summary/Keyword: Passive Matrix

Search Result 139, Processing Time 0.027 seconds

Corrosion Behavior of Bimetal Materials (Fe-Ni / Fe-Ni-Mo) for Electromagnetic Switches (전자 개폐기용 바이메탈 소재(Fe-Ni / Fe-Ni-Mo)의 부식거동)

  • Yu-Jeong An;Eun-Hye Hwang;Jae-Yeol Jeon;Sung Jin Kim
    • Corrosion Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.478-483
    • /
    • 2023
  • This study examined the corrosion behavior of bimetal materials composed of Fe-Ni alloy and Fe-Ni-Mo alloy, both suitable for use in electromagnetic switches. Electrochemical polarization and weight loss measurements revealed that, in contrast to Fe-Ni alloy, which exhibited pseudo-passivity behavior, Fe-Ni-Mo alloy had higher anodic current density, displaying only active dissolution and greater weight loss. This indicated a lower corrosion resistance in the Fe-Ni-Mo alloy. Equilibrium calculations for the phase fraction of precipitates suggested that the addition of 1 wt% Mo may lead to the formation of second-phase precipitates, such as Laves and M6C, in the γ matrix. These precipitates might degrade the homogeneity of the passive film formed on the surface, leading to localized attacks during the corrosion process. Therefore, considering the differences in corrosion kinetics between these bimetal materials, the early degradation caused by galvanic corrosion should be prevented by designing a new alloy, optimizing heat treatment, or implementing periodic in-service maintenance.

Diverse Mechanisms of Relaxin's Action in the Regulation of Smooth Muscles and Extracellular Matrix of Vasculature and Fibrosis (혈관과 섬유증의 평활근 및 세포외기질 조절에 대한 릴랙신의 다양한 작용기전)

  • Min, Gyesik
    • Journal of Life Science
    • /
    • v.32 no.2
    • /
    • pp.175-188
    • /
    • 2022
  • Relaxin has been demonstrated to have regulatory functions on both the smooth muscle and extracellular matrix (ECM) of blood vessels and fibrotic organs. The diverse mechanisms by which relaxin acts on small resistance arteries and fibrotic organs, including the bladder, are reviewed here. Relaxin induces vasodilation by inhibiting the contractility of vascular smooth muscles and by increasing the passive compliance of vessel walls through the reduction of ECM components, such as collagen. The primary cellular mechanism whereby relaxin induces arterial vasodilation is mediated by the endothelium-dependent production of nitric oxide (NO) through the activation of RXFP1/PI3K, Akt phosphorylation, and eNOS. In addition, relaxin triggers different alternative pathways to enhance the vasodilation of renal and mesenteric arteries. In small renal arteries, relaxin stimulates the activation of the endothelial MMPs and EtB receptors and the production of VEGF and PlGF to inhibit myogenic contractility and collagen deposition, thereby bringing about vasodilation. Conversely, in small mesenteric arteries, relaxin augments bradykinin (BK)-evoked relaxation in a time-dependent manner. Whereas the rapid enhancement of the BK-mediated relaxation is dependent on IKCa channels and subsequent EDH induction, the sustained relaxation due to BK depends on COX activation and PGI2. The anti-fibrotic effects of relaxin are mediated by inhibiting the invasion of inflammatory immune cells, the endothelial-to-mesenchymal transition (EndMT), and the differentiation and activation of myofibroblasts. Relaxin also activates the NOS/NO/cGMP/PKG-1 pathways in myofibroblasts to suppress the TGF-β1-induced activation of ERK1/2 and Smad2/3 signaling and deposition of ECM collagen.

THE EFFECT OF HUMAN DBM($GRAFTON^{(R)}$) GRAFT ON SKULL DEFECT IN THE RABBIT (가토의 두개골 결손부에 이식한 human DBM ($Grafton^{(R)}$)의 효과)

  • Kim, Jin-Wook;Park, In-Suk;Lee, Sang-Han;Kim, Chin-Soo;Jang, Hyun-Jung;Kwon, Tae-Geon;Kim, Hyun-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.2
    • /
    • pp.118-126
    • /
    • 2006
  • In oral and maxillofacial surgery, bone graft is very important procedure for functional and esthetic reconstruction. So, many researcher studied about bone graft material like autogenous bone, allograft bone and artificial bone materials. The purpose of this study is to evaluate the quantity of bone generation induced by $Grafton^{(R)}$ graft, human allogenic demineralized bone matrix. Total 24 sites of artificial bony defects prepared using trephin bur(diameter 8 mm) on parietal bone of six adult New Zealand White rabbits. Experimental group had six defect sites which grafted $Grafton^{(R)}$(0.1 cc). Active control group had nine defect sites, into which fresh autogenous bone harvested from own parietal bone was grafted and passive control group had nine defect sites without bone graft. After six weeks postoperatively, the rabbits were sacrificed. The defects and surrounding tissue were harvested and decalcified in 10% EDTA, 10% foamic-acid. Specimens were stained with H&E. New bone area percentage in whole defect area was measured by IMT(VT) image analysis program. Quantity of bone by $Grafton^{(R)}$ graft was smaller than that of autograft and larger than that of empty defects. In histologic view $Grafton^{(R)}$ graft site and autograft site showed similar healing progress but it was observed that newly formed bone in active control group was more mature. In empty defect, quantity and thickness of new bone formation was smaller than in $Grafton^{(R)}$-grafted defect. $Grafton^{(R)}$ is supposed to be a useful bone graft material instead of autogenous bone if proper maintenance for graft material stability and enough healing time were obtained.

X-ray properties measurement of Flat panel Digital X-ray gas detector (평판형 디지털 엑스레이 가스 검출기의 엑스선 특성 측정기술에 관한 연구)

  • Yoon, Min-Seok;Cho, Sung-Ho;Oh, Kyung-Min;Jung, Suk-Hee;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • The Recently, large area matrix-addressed image detectors are investigated for X-ray imaging with medical diagnostic and other applications. In this paper, a new flat panel gas detector for diagnostic X-ray imaging is proposed, and its characteristics are investigated. The research of flat panel gas detector is not exist at all. Because of difficulty to inject gas against to atmospheric pressure. So almost gas detector made by chamber shape. We made flat panel sample by display technique. (ex: PDP, Fed, etc.) The experimental measurements, the transparent electrodes, dielectric layer, and the MgO protection layer were formed in front glass. And, the X-ray phosphor layer and address electrodes are formed in the rare glass. The dark current, the x-ray sensitivity and linearity as a function of electric field were measured to investigate the electrical properties. From the results, the stabilized dark current density and the significant x-ray sensitivity were obtained. And the good linearity as a function of exposure dose was showed in wide diagnostic energy range. These results means that the passive matrix-addressed flat panel gas detector can be used for digital x-ray imaging.

  • PDF

Hybrid Control System Using On-Off Type LQG Algorithm (On-Off 형태의 LQG 알고리즘을 이용한 복합제어 시스템)

  • Jung Hyung-Jo;Yoon Woo-Hyun;Lee In-Won;Park Kyu-Sik
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.18 no.3
    • /
    • pp.227-243
    • /
    • 2005
  • This paper presents a hybrid control system combining lead rubber bearings and hydraulic actuators for seismic response control of a cable stayed bridge. Because multiple control devices are operating, a hybrid control system could improve the control performances. However, the overall system robustness may be impacted negatively by additional active control devices. Therefore, a secondary on-off type controller according to the responses of lead rubber bearings is combined with LQG algorithm to improve the controller robustness. Numerical simulation results show that control performances of the hybrid system controlled by an on off type LQG algorithm are improved compared to those of the passive and active control systems and are similar to those of performance oriented hybrid system controlled by a LQG algorithm with the similar peak and normed control forces. Furthermore, it is verified that the hybrid system with an on-off type LQG controller is more robust for stiffness matrix perturbation than conventional hybrid control of system, and there are no signs of instability in the overall system. The proposed control system also maintains the control performance under not only the design earthquakes but also the other earthquakes. Therefore, the hybrid control system using on-off type LQG algorithm could be proposed as an improved control strategy for seismically excited cable-stayed bridges containing many uncertainties.

Corrosion Behaviors of TiN Coated Dental Casting Alloys (TiN피막 코팅된 치과주조용 합금의 부식거동)

  • Jo, Ho-Hyeong;Park, Geun-Hyeng;Kim, Won-Gi;Choe, Han-Cheol
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.2
    • /
    • pp.129-137
    • /
    • 2009
  • Corrosion behaviors of TiN coated dental casting alloys have been researched by using various electrochemical methods. Three casting alloys (Alloy 1: 63Co-27Cr-5.5Mo, Alloy 2: 63Ni-16Cr-5Mo, Alloy 3: 63Co-30Cr-5Mo) were prepared for fabricating partial denture frameworks with various casting methods; centrifugal casting(CF), high frequency induction casting(HFI) and vacuum pressure casting(VP). The specimens were coated with TiN film by RF-magnetron sputtering method. The corrosion behaviors were investigated using potentiostat (EG&G Co, 263A. USA) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The corrosion morphologies were analyzed using FE-SEM and EDX. Alloy 1 and Alloy 2 showed the ${\alpha}-Co$ and ${\varepsilon}-Co$ phase on the matrix, and it was disappeared in case of TiN coated Alloy 1 and 2. In the Alloy 3, $Ni_2Cr$ second phases were appeared at matrix. Corrosion potentials of TiN coated alloy were higher than that of non-coated alloy, but current density at passive region of TiN coated alloy was lower than that of non-coated alloy. Pitting corrosion resistances were increased in the order of centrifugal casting, high frequency induction casting and vacuum pressure casting method from cyclic potentiodynamic polarization test.

Robust Analysis of a μ-Controller for a Cable-Stayed Bridge with Various Uncertainties (사장교에서 다양한 불확실성에 대한 μ-제어기의 강인성 해석)

  • Park, Kyu Sik;Spencer, B.F.Jr.;Kim, Chun Ho;Lee, In Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5A
    • /
    • pp.849-859
    • /
    • 2006
  • This paper presents an extensive robust analysis of a ${\mu}$-controller in the hybrid system for various uncertainties using the benchmark cable-stayed bridge. The overall system robustness may be deteriorated by introducing active devices and the active controller may cause instability due to small margins. Therefore, a ${\mu}$-synthesis method that simultaneously guarantees the performance and stability of the closed-loop system (robust performance) with uncertainties is used for active devices to enhance the robustness in company with the inherent reliability of passive devices. The robustness of the ${\mu}$-synthesis method is investigated with respect to the additional mass on the deck, structural stiffness matrix perturbation, time delay of actuator, and combinations thereof. Numerical simulation results show that the proposed control system has the good robustness without loss of control performances with respect to various uncertainties under earthquakes considered in this study. Furthermore, the control system robustness is more affected by the perturbation of structural stiffness matrix than others considered in this study. Therefore, the hybrid system controlled by a ${\mu}$-synthesis method could be proposed as an improved control strategy for a seismically excited cable-stayed bridge containing many uncertainties.

Stereo cameras calibration bases on Epipolar Rectification and its Application

  • Chaewieang, Pipat;Thepmanee, Teerawat;Kummool, Sart;Jaruvanawat, Anuchit;Sirisantisamrid, Kaset
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.246-249
    • /
    • 2003
  • The constraints necessary guarantee using the comparison of these extrinsic parameters, which each Rotation matrix and Translation Vector must be equal to the either, except the X-axis Translation Vector. Thus, we can not yet calculate the 3D-range measurement in the end of camera calibration. To minimize this disadvantage, the Epipolar Rectification has been proposed in the literature. This paper aims to present the development of Epipolar Rectification to calibrate Stereo cameras. The required computation of the transformation mapping between points in 3D-space is based on calculating the image point that appears on new image plane by using calibrated parameters. This computation is assumed from the rotating the old ones around their optical center until focal planes becomes coplanar, thereby containing the baseline, and the Z-axis of both camera coordinate to be parallel together. The optical center positions of the new extrinsic parameters are the same as the old camera, whereas the new orientation differs from the old ones by the suitable rotations. The intrinsic parameters are the same for both cameras. So that, after completed calibration process, immediately can calculate the 3D-range measurement. And the rectification determines a transformation of each image plane such that pairs of conjugate Epipolar lines become collinear and parallel to one of the image axis. From the experimental results verify the proposed technique are agreed with the expected specifications.

  • PDF

Vision-based Obstacle Detection using Geometric Analysis (기하학적 해석을 이용한 비전 기반의 장애물 검출)

  • Lee Jong-Shill;Lee Eung-Hyuk;Kim In-Young;Kim Sun-I.
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.3 s.309
    • /
    • pp.8-15
    • /
    • 2006
  • Obstacle detection is an important task for many mobile robot applications. The methods using stereo vision and optical flow are computationally expensive. Therefore, this paper presents a vision-based obstacle detection method using only two view images. The method uses a single passive camera and odometry, performs in real-time. The proposed method is an obstacle detection method using 3D reconstruction from taro views. Processing begins with feature extraction for each input image using Dr. Lowe's SIFT(Scale Invariant Feature Transform) and establish the correspondence of features across input images. Using extrinsic camera rotation and translation matrix which is provided by odometry, we could calculate the 3D position of these corresponding points by triangulation. The results of triangulation are partial 3D reconstruction for obstacles. The proposed method has been tested successfully on an indoor mobile robot and is able to detect obstacles at 75msec.

Skin Penetration and Localization Characteristics of Lipogel Containing Ascorbyl Palmitate (아스코르빈산 팔미테이트를 함유한 리포겔의 피부 투과 및 잔류 특성)

  • Lee, Sang-Kil;Woo, Hye-Seoung;Lee, Yeon-Ah;Kwon, Yong-Nam;Choi, Young-Wook
    • Journal of Pharmaceutical Investigation
    • /
    • v.31 no.4
    • /
    • pp.225-232
    • /
    • 2001
  • The present study was carried out to observe the effect of liposome dispersed gel formulation (Lipogel) on topical delivery of ascorbyl palmitate (AsP). Neutral and negatively charged MLV liposomes containing AsP were prepared with dimyristoylphosphadtidylcholine (DMPC) and dicetyl phosphate (DCP), and dispersed to poloxamer gel matrix. In the hydrolysis study in rat's skin homogenates, AsP hydrolyzed to ascorbic acid (AsA) according to the first-order kinetics with the rate constant of $2.46{\times}10^{-2}\;min^{-1}$. In the passive skin penetration study using Franz diffusion cell, lipogel systems exhibited the greater values in the flux $(J_s)$ and the amount penetrated $(Q_p)$ compared to control hydrogels containing diethyleneglycol monoethyl ether $(Transcutol^{\circledR})$ as a solubilizing agent and a penetration enhancer for AsP. The total amount penetrated $(Q_{Total})$, which is expressed as a summation of $Q_P\;and\;Q_L$, for lipogel system was about 1.4 times higher in average than that of control hydrogel. However the amount localized in the skin $(Q_L)$ was similar in both formulations. As a result, lipogel system enhanced the skin penetration of AsP, possibly due to the increase in local concentration of AsP by preferential adsorption of liposome to the skin and the enhancing effect of phospholipid in liposome composition. Moreover it was expected that the penetrated AsP would generate AsA during skin penetration by the skin esterase. In conclusion, lipogel formulation was considered as a good candidate for topical delivery of AsP.

  • PDF