• 제목/요약/키워드: Passive Cooling Method

검색결과 36건 처리시간 0.018초

Effective Thermal Conductivity and Diffusivity of Containment Wall for Nuclear Power Plant OPR1000

  • Noh, Hyung Gyun;Lee, Jong Hwi;Kang, Hie Chan;Park, Hyun Sun
    • Nuclear Engineering and Technology
    • /
    • 제49권3호
    • /
    • pp.459-465
    • /
    • 2017
  • The goal of this study is to evaluate the effective thermal conductivity and diffusivity of containment walls as heat sinks or passive cooling systems during nuclear power plant (NPP) accidents. Containment walls consist of steel reinforced concrete, steel liners, and tendons, and provide the main thermal resistance of the heat sinks, which varies with the volume fraction and geometric alignment of the rebar and tendons, as well as the temperature and chemical composition. The target geometry for the containment walls of this work is the standard Korean NPP OPR1000. Sample tests and numerical simulations are conducted to verify the correlations for models with different densities of concrete, volume fractions, and alignments of steel. Estimation of the effective thermal conductivity and diffusivity of the containment wall models is proposed. The Maxwell model and modified Rayleigh volume fraction model employed in the present work predict the experiment and finite volume method (FVM) results well. The effective thermal conductivity and diffusivity of the containment walls are summarized as functions of density, temperature, and the volume fraction of steel for the analysis of the NPP accidents.

An Examination of Load Cut-off Effect Using Modern Buildings in Korean Traditional Passive Methods

  • Kim, Hwan-yong;Song, Young-hak;Kim, Hyemi
    • Architectural research
    • /
    • 제19권2호
    • /
    • pp.45-52
    • /
    • 2017
  • Recently, as a new perspective to view the architecture in relation to global environmental problems, interest in environmental architecture that conforms to the surrounding environment and nature with nature has been expanded as a part of the natural ecosystem, rather than seeing the building as an independent entity. Traditional Korean architecture creates a comfortable indoor environment by appropriately using the natural energy around, ranging from the arrangement of the building and the space composition to the use of detailed materials and to harmonize the artificial architectural environment without harming the natural ecosystem. The purpose of this study is to propose a method to apply the environmental control techniques of traditional buildings to modern buildings. As a research method, the characteristics of Korean traditional buildings according to the climatic characteristics of Korea were recognized through existing literature data and when applied to methods of traditional buildings, ventilation systems, control through eaves, and humidity control using Hanji the effect of energy load control on traditional buildings was analyzed and identified through existing literature. After analyzing the problems of modern architecture, we analyzed the effect of the environmental control system of traditional architecture on modern architecture. Simulation results show that the application of the environmental control system of traditional buildings to modern buildings reduces the cooling and heating load of modern buildings and has an effect on humidity control. This study suggests that quantitative energy saving will be possible if the environmental control techniques of traditional buildings are appropriately applied to modern buildings.

HEPA Filter형 숨쉬는 벽체용 나노세라믹 여재개발 (Development of Nano Ceramic Structures for HEPA Type Breathing Wall)

  • 김종원;안영철;김길태
    • 설비공학논문집
    • /
    • 제20권4호
    • /
    • pp.274-279
    • /
    • 2008
  • In the perspective of saving energy in buildings, high performance of insulation and air tightness for improving the heating and the cooling efficiency has brought the positive effect in an economical view. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and it is also very harmful to residents because they spend over 90% of their time in the indoor area. Therefore, the ventilation is important to keep indoor environment clean and it can also save energy consumption. In this study, a HEPA type breathing wall is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. To make fine porous structures, polymer nano fibers which were made by electro spinning method are used as a precursor. The nano fibers are coated with SiO2 nano particles and finally the HEPA type breathing wall is made by sintering in the electric furnace at $300\sim500^{\circ}C$. The pressure drops of nano ceramic structure are 8.2, 25.5 and 44.9 mmAq at the face velocity of 2.0, 5.9 and 8.8 cm/s, respectively. Also the water vapor permeability is $3.6g/m^2{\cdot}h{\cdot}mmHg$. In this research, the porous nano ceramic structures are obtained and the possibility for the usage of a material for HEPA type breathing wall can be obtained.

단일 모드 2 kW급 고출력 광섬유 증폭기 내의 광섬유 용융 현상에 관한 연구 (A Study of the Fiber Fuse in Single-mode 2-kW-class High-power Fiber Amplifiers)

  • 이준수;이광현;정환성;김동준;이정환;조민식
    • 한국광학회지
    • /
    • 제31권1호
    • /
    • pp.7-12
    • /
    • 2020
  • 본 연구에서는 단일 모드 2 kW급 고출력 광섬유 증폭기에서 발생한 광섬유 용융 현상을 융착점 냉각 특성에 따라 실험적으로 분석한 결과를 소개한다. 레이저 출력에 따른 펌프 광 결합기와 주증폭기 이득 광섬유 사이의 융착점 온도를 레이저 출력에 따라 측정하였다. 융착점 온도는 레이저 출력 1.2 kW까지는 20℃에서 32℃까지 온도 상승 기울기 0.01℃/W로 증가율이 작았으나 1.2 kW 이후부터 온도 상승 기울기 0.08℃/W로 융착점 온도가 급격하게 증가하였고 1.96 kW 출력에서 동작 중 광섬유 용융 현상에 의해 광섬유 증폭기가 손상되었다. 손상된 펌프 광 결합기의 전송 광섬유 코어에는 광섬유 용융의 전형적인 탄환모양손상 형상이 나타났다. 이후 수냉식 냉각판을 적용하여 융착점 부위의 냉각 성능을 향상시킨 후 레이저 출력 특성 변화를 조사하였다. 최대 출력 2.05 kW에서 광섬유 융착점 온도는 35.8℃였고 레이저 출력에 따른 온도 상승 기울기는 0.007℃/W로서 급격한 증가 없이 일정하게 유지되었다. 광섬유 증폭기에서 광섬유 용융 현상은 발생하지 않았으며 최대 출력 2.05 kW에서 모드 불안정성 역시 발생하지 않았다. 최대 출력 2.05 kW까지 빔 프로파일은 안정적인 가우시안 형태였으며 빔 품질 1.3 이하를 유지하였다.

전투차량용 분배함의 노이즈 감소를 위한 릴레이 응용 (The Application of Relays for Noise Reduction in the Combat Vehicle Distribution Box)

  • 곽대환;박동민;오은빈;김창욱
    • 한국산학기술학회논문지
    • /
    • 제21권8호
    • /
    • pp.235-240
    • /
    • 2020
  • 본 연구에서는 전투차량용 분배함에 적용된 회로기판에서 전자파 적합성(electromagnetic compatibility, EMC) 시험 간 발생한 전도 노이즈의 원인을 분석하고, 이를 개선하는 방안을 마련하였다. 규격 미충족 분배함에 대한 분석을 진행한 결과, 분배함 내 회로기판의 컨버터 및 반도체 스위칭 소자가 전도노이즈를 유발하는 것을 확인할 수 있었다. 해당 회로카드는 체계장비에 탑재되어 발전기 및 배터리로부터 전원을 공급받아 전력이 필요한 각 구성품으로 공급하는 장치이다. 규격 미충족 구성품은 냉방장치 가동을 위한 회로를 포함하는데 부하특성 확인 결과, 반도체 스위칭 소자가 냉방장치의 켬 혹은 끔 상태를 유지하는 용도로 사용된다는 것을 확인할 수 있었다. 이를 개선하기 위하여 수동필터를 추가하여 노이즈를 감소시키는 첫 번째 방법과, 노이즈의 근원이 되는 컨버터 및 반도체 스위칭 소자를 릴레이로 대체하는 두 번째 방법을 제안하였다. 두 방법에 대해 발생하는 전도 노이즈를 측정한 결과, 두 방법 모두 효과가 있었으나 기존 컨버터 및 스위치를 릴레이로 대체하는 것이 노이즈 감소에 유리함을 확인하여, 필터를 추가하는 것보다 노이즈가 발생하는 원인을 제거하는 방법을 적용하기로 하였다. 최종적으로 릴레이를 적용하여 전투차량용 분배함을 개선하였으며 체계적합성 역시 만족하는 것을 확인하였다.

ZEB 활성화를 위한 부하기준 산정 방법 연구 (A Study on the Calculation Method of Load standard for ZEB activation)

  • 이항주;김인수
    • 에너지공학
    • /
    • 제26권4호
    • /
    • pp.92-99
    • /
    • 2017
  • 국내에서는 국토부 7대 신산업, 산업부 8대 신산업으로 제로에너지빌딩이 지정되었으며, 건물외피의 단열성능 극대화와 건물 기기 효율향상 및 신재생 보급 확대를 위해 부처간 융합을 통해 제로에너지빌딩 보급 활성화 달성을 목표로 하고 있다. 국내에서 시행 중인 제로에너지빌딩 인증제에 해당되는 건물에너지효율등급 1++이상이 되는 건축물들의 부하(냉방, 난방, 급탕, 조명, 환기)들의 에너지소요량을 분석하여 대략적인 부하들의 수준을 파악하고 제로에너지빌딩 인증제 고도화를 위한 기초 자료로 활용될 수 있도록 하는 목적이 있다. 제로에너지빌딩 인증에 해당되는 건축물은 2017년 기준 61개 가량 되는 것으로 파악되고 있으며, 패시브 측면과 액티브 측면을 고려하여 5대 부하별 대략적인 기준 값과 1차 에너지소요량을 산정하였다. 부하기준 산정을 위한 데이터의 표본이 적어 명확한 기준이 된다고 보기는 어려우나 앞으로 제로에너지빌딩 인증 기준을 고도화하기 위해 다양한 방법들을 적용하여 해석할 필요성이 있다고 판단된다.