• Title/Summary/Keyword: Passage

Search Result 2,430, Processing Time 0.028 seconds

Performance Analysis of a Flow Passage Opening Device through Low Speed Aircraft Captive Flight Tests

  • Jung, Sung-Min;Park, Jeong-Bae
    • International Journal of Aerospace System Engineering
    • /
    • v.4 no.2
    • /
    • pp.5-9
    • /
    • 2017
  • In a pressurized fuel supply system of aircraft, a flow passage opening device is required to keep fuel continuously transferred from one tank to the other. The device utilizes balancing weights in order to follow up an acceleration at special conditions such as negative g. It is very difficult to test the device in a real high-speed and high-altitude test since severe test conditions and expensive supports are needed. Therefore, this paper deals with performance analysis of a flow passage opening device through low speed aircraft captive flight tests (CFT) including roll and negative-g maneuvers. It is shown that balancing weights in the device can open the passage in accordance with fuel position.

The Effect of Partial Blockage of Flow Passage to Performance Change of a Liquid Rocket Engine (유로 단면 부분 폐쇄가 액체로켓엔진 성능 변화에 미치는 영향)

  • Cho, Won Kook
    • Journal of Aerospace System Engineering
    • /
    • v.9 no.4
    • /
    • pp.67-72
    • /
    • 2015
  • The analysis has been performed on the blockage effect at the propellant flow passage in a liquid rocket engine. This simulates an example of emergency situation where flow passage is partially blocked. The analysis method has been validated by predicting the pump head and flow rate within 1% precision against the measured data of turbopump-gas generator coupled test. When the oxidizer passage is reduced it is predicted that the mixture ratio decreases, the oxidizer pump head increases and the gas generator pressure increases. When the fuel passage is reduced it is predicted that the mixture ratio increases, fuel flow rate decreases and the fuel pump head increases.

Difference of Perception and Preference of Color According to Time Passage -Comparison between 1998 and 2004- (시간경과에 따른 색상의 인지도와 선호도의 차이 -1998년과 2004년의 색상 인지도와 선호도 비교 -)

  • Park, Hea-Ryung;Shim, Kue-Nam;Park, Mee-Ryung
    • Fashion & Textile Research Journal
    • /
    • v.8 no.2
    • /
    • pp.191-195
    • /
    • 2006
  • The purpose of this study was to identify the change of perception and preference of color according to time passage. The subjects were university students and for the survey 257 questionnaires in 1998 and 522 questionnaires in 2005 were effectively used to compare the perception and preference of color between the both period. The statistics was performed with frequency analysis and independent t-test in SPSS 10.0. The results were as follows. 1) Color perception according to time passage showed significant differences in red, yellow, green, and blue color. 2) Color preference according to time passage showed significant differences in red, green, and blue color. 3) Color perception among three regions according to time passage showed significant differences in red color in Seoul, yellow color in Seoul, Mokpo and Jeju, green color in Seoul and Mokpo, blue color in Seoul, Mokpo and Jeju, and purple color in Seoul. 4) Color preference among three regions according to time passage showed significant differences in yellow color in Mokpo, green and blue color in Seoul, Mokpo and Jeju.

Pathogenesis of infectious bronchitis virus with different routes of inoculation and the effect of in vivo serial passage in nephropathogenicity using cloacal infection

  • Lee, Chang-Won
    • Korean Journal of Veterinary Service
    • /
    • v.25 no.1
    • /
    • pp.87-96
    • /
    • 2002
  • In this study, we wanted to determine if the respirotropic JMK strain of infectious bronchitis virus(IBV), which has a spike glycoprotein gene that is 99% similar to the nephropathogenic Gray strain of IBV, could adapt and cause lesions in the kidney following intracloacal passage in chickens. Two day old specific pathogen free(SPF) cchickens were infected with Gray and JMK strains by the intraocular and cloacal route. Several tissue samples were collected at various times. Viruses were recovered from more tissues and earlier in the infection from chickens infected cloacally than chickens infected intraocularly. Virus was isolated from the kidney of chickens infected with Gray by the intraocular route and JMK by the intracloacal route, but not from chicken given JMK the intraocular route. Histopathologically, interstitial nephritis was observed in Gray infected chickens. However, viral RNA or antigen were not detected in the kidney by in situ hybridization and immunohistochemistry. We further passaged the JMK strain ten times in two day old SPF chickens using cloacal inoculation. We examined the virus titer and histopathological change in the kidney at each passage level. The amount of virus recovered from the kidney was stable throughout this serial passage and the passaged virus did not caused renal damage. Further, virus could not be isolated from the kidney when chickens were infected with the passaged virus by the intraocular route. We conclude that the JMK strain has a strict upper respiratory tract tropism since cloacal passage did not produce nephrotropism or nephropathogenicity.

A Feasibility Study on the Flow Passage Shape for an Inline Francis Hydro Turbine

  • Chen, Chengcheng;Singh, Patrick Mark;Inagaki, Morihito;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.2
    • /
    • pp.5-13
    • /
    • 2015
  • The aim of this study is to investigate the feasibility of a new type of casing for the inline Francis hydro turbine. Comparing with the traditional turbine with spiral casing, this turbine is unique for its flow passage shape at the first stage of flow to the turbine, very similar to a pipe, called inline casing. Before the commercialization of this new type of casing, a global investigation of the inline casing must be conducted. Preserving the structural characteristics of simple, compact-size and convenient for manufacture, different shapes of the belt passage, vertical corner and stay vanes are applied to investigate the influence of flow passage shape on the turbine performance. Stable and relatively high efficiency is achieved regardless of flow passage shape difference proving the feasibility of the inline casing used in a hydro turbine.

A Numerical Simulation of Heat and Fluid Flow for Predicting the Effect of Passage Arrangement in Automotive Heat Battery (자동차용 열전지에서 유로배열 효과 예측을 위한 열유동 수치묘사)

  • Lee, K.S.;Kwon, J.W.;Baek, C.I.;Song, Y.K.;Han, C.S.;Kim, D.J.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.5
    • /
    • pp.64-73
    • /
    • 1995
  • A numerical simulation of heat and fluid flow for predicting the effect of passage arrangement in automotive heat battery has been performed. The system is assumed to be a two-dimensional laminar flow and isothermal boundary is applied to the surface of the latent heat storage vessel. In the case of ideal heat battery the flow rate into each flow passage is evenly distributed. The various models are considered in the view of pressure drop and bulk temperature. The effects on the efficiency of the heat battery are examined by varying geometrical factors such as flow passage clearance, length of a inlet and outlet tank and the length of a latent heat storage vessel. The flow clearance is a very important -factor on the efficiency of a heat battery. As the flow passage clearance becomes narrow, the flow distribution becomes uniform and the bulk temperature increases, however the pressure drop is large. Therefore, optimal flow passage clearance has to be chosen. The present work can be used in optimizing heat battery efficiency.

  • PDF

Development of Objective Nasometer Using a Vibratory Sensor and its Clinical Application (진동 센서를 이용한 객관적 비강공명 측정 장치의 개발 및 그 임상적 이용)

  • 최홍식;박용재;김광문
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.6 no.1
    • /
    • pp.46-55
    • /
    • 1995
  • Authors devised an objective test for nasal resonatory disorders using a vibratory sensor(Piezoelectric receiver) which is relatively cheap. The vibratory sensor was covered with duralumin to eliminate contamination of acoustic sound except a small hole which is attached on ala nasi during the test. Electrical signals front the vibratory sensor and the microphone while the subject is phonating vowel/a/ and nasal consonant /ng/ and phonating 8 syllable sentence /papa/ passage and /mama/ passage were digitized with n 12 bit A/D converter. For the evaluation of the hypernasality, the ratio of /ng/ to /a/ and /mama/ passage to /papa/ passage were used instead of individual values to reduce the observational error. For the evaluation of the hyponasality, the cul-de-sac resonation was induced by obstructing the nasal aperture of the ipsilateral side with the finger. In the normal control group, the ratio of /ng/ to /a/ and /mama/ passage to /papa/ passage was larger than 8. In the hypernasality with nasal emission group. the ratio was decreased markedly(p<0.01). When the nasal aperture was obstructed with the finger, the vibratory signals of /a/ and /ng/ were increased markedly in the control group and hypernasality group(p<0.01). However, in the hyponasality group(severe), the increment was minimal. So this system can be used to detect the nasal resonatory disorders objectively and differentiate the hypernasality front hyponasality easily.

  • PDF

Mechanical Mechanism of Main Tunnels and Cross Passage Construction - A 3D Numerical Investigation

  • Yoo, Chungsik;Shuaishuai, Cui;Ke, Wu;Qianjn, Zhang;Zheng, Zhang;Jiahui, Zhao
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.1
    • /
    • pp.11-23
    • /
    • 2019
  • This paper presents the results of a three-dimensional numerical investigation into the mechanical mechanism of main tunnels and cross passage construction. Aimed at the complex space structure composed of two main tunnels and cross passage, 3D numerical model of the structure and surrounding rock was built to analyze the influence. Comparative analysis of different buried depths were carried out. The results of the study indicate that the stress concentration was occurred in the intersecting linings, especially in the opening side lining, which leads to an unfavorable form of force that is pulled up by the upper and lower sections in the intersecting linings due to the construction of the cross passage. The excavation of the cross passage also destroys the stability of the original soil layer and causes settlement of the surface and main tunnels. Practical implications of the findings are discussed.

Characteristics of Fine Particles during Cold Front Passage in Busan, on March 19, 2020 (부산지역 2020년 3월 19일 한랭전선 통과 시 미세먼지 농도 특성)

  • Jeon, Byung-Il
    • Journal of Environmental Science International
    • /
    • v.30 no.6
    • /
    • pp.475-485
    • /
    • 2021
  • This research investigated the characteristics of fine particles during cold front passage in Busan, on March 19, 2020. The cold front speed was 17.4 m/s (about 63k km/hr), moving from the northwest to the southeast, and with a width of about 64 km. The backward trajectory analysis showed that a southern sea air parcel flowed into Busan before the cold front passage, carrying continental materials from China transported into Busan after cold front passage. The PM10 concentration in Busan showed a rapid increase after passing through the cold front, with PM2.5 showing a high concentration during cold front passage. The PM2.5/PM10 ratio was 0.10 - 0.30. When the cold front passed, SO42-, NO3-, Ca2+, NH4+, Na+, and K+ in PM2.5 showed a rapid increase, with SO42- showing the most significant increase. These results indicated that understanding the characteristics of fine particles during cold front passage in Busan could provide insight into establishing a strategy to control urban air quality.

A Comparison between Low- and High-Passage Strains of Human CytomegalovirusS

  • Wang, Wen-Dan;Lee, Gyu-Cheol;Kim, Yu Young;Lee, Chan Hee
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.10
    • /
    • pp.1800-1807
    • /
    • 2016
  • To understand how human cytomegalovirus (HCMV) might change and evolve after reactivation, it is very important to understand how the nucleotide sequence of cultured HCMV changes after in vitro passaging in cell culture, and how these changes affect the genome of HCMV and the consequent variation in amino acid sequence. Strain JHC of HCMV was propagated in vitro for more than 40 passages and its biological and genetic changes were monitored. For each passage, real-time PCR was performed in order to determine the genome copy number, and a plaque assay was employed to get virus infection titers. The infectious virus titers gradually increased with passaging in cell culture, whereas the number of virus genome copies remained relatively unchanged. A linear correlation was observed between the passage number and the log10 infectious virus titer per virus genome copy number. To understand the genetic basis underlying the increase in HCMV infectivity with increasing passage, the whole-genome DNA sequence of the high-passage strain was determined and compared with the genome sequence of the low-passage strain. Out of 100 mutations found in the high-passage strain, only two were located in an open reading frame. A G-T substitution in the RL13 gene resulted in a nonsense mutation and caused an early stop. A G-A substitution in the UL122 gene generated an S-F nonsynonymous mutation. The mutations in the RL13 and UL122 genes might be related to the increase in virus infectivity, although the role of the mutations found in noncoding regions could not be excluded.