• Title/Summary/Keyword: Pass Analysis

Search Result 1,180, Processing Time 0.039 seconds

A Study on the Design and Characteristics of thin-film L-C Band Pass Filter

  • Kim In-Sung;Song Jae-Sung;Min Bok-Ki;Lee Won-Jae;Muller Alexandru
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.4
    • /
    • pp.176-179
    • /
    • 2005
  • The increasing demand for high density packaging technologies and the evolution to mixed digital and analogue devices has been the con-set of increasing research in thin film multi-layer technologies such as the passive components integration technology. In this paper, Cu and TaO thin film with RF sputtering was deposited for spiral inductor and MOM capacitor on the $SiO_2$/Si(100) substrate. MOM capacitor and spiral inductor were fabricated for L-C band pass filter by sputtering and lift-off. We are analyzed and designed thin films L-C passive components for band pass filter at 900 MHz and 1.8 GHz, important devices for mobile communication system. Based on the high-Q values of passive components, MOM capacitor and spiral inductors for L-C band pass filter, a low insertion loss of L-C passive components can be realized with a minimized chip area. The insertion loss was 3 dB for a 1.8 GHz filter, and 5 dB for a 900 MHz filter. This paper also discusses a analysis and practical design to thin-film L-C band pass filter.

Safety Improvement of Centrally Installed "Hi-pass" Lane of Express Highway (고속도로 중앙하이패스차로 안전성 개선에 관한 연구 - 서울외곽순환고속도로 본선영업소를 중심으로 -)

  • Yoo, Bong-Seok;Lee, Soo-Beom;Park, Wan-Yong;Do, Hyun-Gu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1D
    • /
    • pp.1-10
    • /
    • 2010
  • Safety improvement has been a continuous challenge, especially at toll gate of express highway where traffic conflict often occurs due to frequent lane change by drivers of "Hi-pass" lane and regular "TCS" lane. As a part of research on safety at toll gate, this study videotaped traffic conflict data between vehicles using centrally located "Hi-pass" lane and regular "TCS" lane and analyzed accident risk. According to the correlation analysis of vehicle speed, relative vehicle speed, and sudden vehicle deceleration rate due to traffic conflict, when the relative vehicle speed between centrally located "Hi-pass" lane and regular "TCS" lane increases, sudden vehicle deceleration rate also increases. One of the findings is that centrally located "Hi-pass" lane at toll gate shows different location for traffic conflict, and frequency of traffic conflict and the relative vehicle speed was also different based on vehicle lane use. TA (Time to Accident) analysis shows that accident rate is high at toll gate where Hipass lane is installed in center lane, when the occurrence of sudden vehicle deceleration and deceleration time of vehicles rise for vehicles on "Hi-pass" lane. Furthermore, if the expressway entrance/exit point is closely located to toll gate, TA showed a low value. Thus, it is necessary to reduce the relative vehicle speed in order to improve safety. The Study presents reduction of the relevant vehicular speed and prevention of accidents at the centrally installed "Hi-pass" lane as an important strategy for safety improvement at toll gate.

Effectiveness and Technical Considerations of Solitaire Platinum 4×40 mm Stent Retriever in Mechanical Thrombectomy with Solumbra Technique

  • Yi, Ho Jun;Sung, Jae Hoon;Lee, Dong Hoon;Song, Seung Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.1
    • /
    • pp.30-38
    • /
    • 2021
  • Objective : The Solitaire Platinum 4×40 mm stent retriever contains radiopaque markers with a long length. We evaluated the effect of Solitaire Platinum 4×40 mm stent retriever in Solumbra technique thrombectomy, and compared it with shorter Solitaire stent retrievers. Methods : A total of 70 patients who underwent Solumbra technique thrombectomy with equal diameter (4 mm) and different length (40 vs. 20 mm) Solitaire stent retrievers were divided into two groups : the Solitaire Platinum 4×40 mm stent (4×40) group and the Solitaire FR 4×20 mm stent or Solitaire Platinum 4×20 mm stent (4×20) group. The clinical outcomes, Thrombolysis in Cerebral Infarction score, the first pass reperfusion status, and complications were evaluated and compared between the two groups. Multivariate analysis was performed to evaluate the predictive factors for reperfusion and complete reperfusion from the first pass. Results : Higher first-pass reperfusion and complete reperfusion were achieved in the 4×40 group (68.0% and 48.0%) than in the 4×20 group (46.7% and 33.3%; p=0.004 and 0.007, respectively). In multivariate analysis, radiopaque device and longer stent retriever were correlated with first-pass reperfusion (p=0.014 and 0.008, respectively) and first-pass complete reperfusion (p=0.022 and 0.012, respectively). Conclusion : Our study demonstrated the usefulness of the Solitaire Platinum 4×40 mm stent retriever, which led to higher first-pass reperfusion and complete reperfusion rates than the Solitaire FR 4×20 mm stent or the Solitaire Platinum 4×20 mm stent, especially in Solumbra technique thrombectomy.

Residual Stress and Displacement Analysis of Thick Plate for Partial Penetration Multi-Pass Weldment (후판의 부분용입 다층용접에 대한 잔류음력 및 변형해석)

  • Kim, Seok;Bae, Sung-In;Song, Jung-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.11
    • /
    • pp.1813-1819
    • /
    • 2001
  • Partial penetration welding Joint defines that groove welds without steel backing, welded from on side, and groove weeds welded from both sides but without back gouging, that is. it has an unwelded portion at the root of the weld. In this study we analysed fur residual stress and displacement distribution on partial penetration welding condition of thick plate metal. For 25.4mm thick plate, theoretical residual stress and displacement analysis by finite element method using ABAQUS was carried out and compared with the experimental result using hole-drilling method. In results of the condition of partial penetration, it appeared that longitudinal stress at welding area was a little difference and transverse stress did not have any effect by partial penetration multi-pass welding. From a point of welding distortion in partial penetration multi-pass welding, it seemed to be better to control root face smaller than 6.35mm.

Residual Stress and Fracture Analysis of Thick Plate for Partial Penetration Multi-pass Weldment (후판 부분용입 다층용접의 잔류음력 및 파괴 해석)

  • Kim, Seok;Shim, Yong-Lae;Bae, Sung-In;Song, Jung-Il
    • Journal of Welding and Joining
    • /
    • v.19 no.6
    • /
    • pp.636-642
    • /
    • 2001
  • Partial penetration welding joint defines the groove welds that applies the one side welding which does not use steel backing and both side welding without back gouging, that is, the partial penetration welding joint leaves an unwelded portion at the root of the welding area. In this study, we analyzed the residual stress and fracture on the thick metal plates that introduced the partial penetration welding method. As results of using above mentioned welding method, we could draw a conclusion that longitudinal stress and traverse stress occurred around the welding area was so minimal and did not affect any influence. We also performed the fracture behavior evaluation on the partial penetration multi-pass welding with 25.4mm thick plate by using theJ-integral, which finally led us the conclusion that the partial penetration multi -pass welding method is more applicable and effective in handling the root face with less than 6.35mm.

  • PDF

Performance Analysis on a Low Pass Filter of a CT Saturation Detecting Algorithm Using Difference of the Secondary Current (차분을 이용한 변류기 포화 검출 알고리즘의 저역통과 필터의 영향 분석)

  • Kang, Young-Cheol;Ok, Seung-Hun;Yun, Jae-Sung;Kim, Dae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.249-251
    • /
    • 2001
  • This paper presents performance analysis on a low pass filter of a CT saturation detecting algorithm using difference. At the instants of beginning/end of saturation, the shapes of the secondary current are changed significantly though secondary currents are continuous. At the instants, the second-order or third-order difference of the secondary current has big values because of discontinuity of the first order difference. Thus, the third difference of the current is used to detect the beginning/end of CT saturation. An antialiasing low pass filter removes high frequency components and causes phase lag. A CT saturation detecting algorithm using difference of CT secondary currents is affected by the low pass filter. The algorithm is tested with cutoff frequencies of the filter for the two sampling rates of 64[S/C] and 32 [S/C]. The results of various test cases indicate satisfactory performance of the algorithm.

  • PDF

Residual Stress and Fracture Analysis of Thick Plate for Partial Penetration Multi-Pass Weldment

  • Kim, Seok;Shim, Yong-Lae;Song, Jung-Il
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.9
    • /
    • pp.1033-1039
    • /
    • 2002
  • Partial penetration welding joint refers to the groove weld that applies to the one side welding which does not use steel backing and to both side welding without back gouging, that is, the partial penetration welding joint leaves an unwelded portion at the root of the welding area. In this study, we analyzed the residual stress and fracture on the thick metal plates that introduced the partial penetration welding method. According to the above-mentioned welding method, we could draw a conclusion that longitudinal stress and traverse stress occurred around the welding area are so minimal and do not affect any influence. We also performed the fracture behavior evaluation on the partial penetration multi pass welding with 25.4 mm thick plate by using the J-integral, which finally led us the conclusion that the partial penetration multi-pass welding method is more applicable and effective in handling the root face with less than 6.35 mm.

RESEARCH ON THE IMPROVEMENT OF FORGEABILITY OF SNCM STEEL

  • Park I.W.;Jung D.J.;Je J.S.;Joun M.S.;Kang S.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10b
    • /
    • pp.80-85
    • /
    • 2003
  • This research represents enhancement of forgeability of SNCM522H steel. Output Shaft (OP Shaft) has been used as a subject for the study. OP Shaft is used as component of power train for automobiles. To develop I pass cold forging process instead of existing 2 pass process for OP Shaft, studies in terms of process design and heat treatment were performed. To verify the new process, CAE simulations were performed. And hardness test, microstructural analysis and tensile tests after heat treatment were carried out to evaluate the validity of proposed heat treatment cycle. The 2 pass forging process could be reduced as 1 pass process through improvement of process and heat treatment cycle.

  • PDF

Analysis of Sagnac Loop Band-pass Filter in Incorporating Fiber Bragg Gratings (FBG를 삽입한 사냑 루프 대역 통과 필터의 해석)

  • Jung, Eun-Joo;Jeong, Myung-Yung;Kim, Chang-Seok
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.2
    • /
    • pp.105-110
    • /
    • 2007
  • A tunable band-pass filter of fiber Bragg gratings incorporating the Sagnac loop interferometer configuration is presented. The proposed band-pass filter with extinction ratio 20 dB has practical advantages in terms of price and performance in comparison with the conventional band-pass filter using a circulator.

Application of Critical Damage Value to Continuous Drawing Process using FEM (연속 인발공정에서 유한요소법을 이용한 Critical Damage Value 의 적용)

  • 박동인;김병민;고대철
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10a
    • /
    • pp.291-295
    • /
    • 2003
  • The occurrence of ductile fracture is the working limit of many metal forming processes. It is necessary to predict the criteria and to apply the condition in a process design. Over the years. the way for clarifying conditions have been studied and presented. However such a way needs lots of experiments and analysis. In this study, in order to determine the critical damage value of a used material Cu 4N, it was performed a tensile test and FEM analysis by using DEFORM 2D. For applying the obtained critical damage value it was also performed a upsetting test by using DEFORM 2D. The way of determining a critical damage value which is presented in this study will make possible to find easily it which is one of the working limit factor. And the way of determining a critical damage value will make possible to find in multi-pass drawing process.

  • PDF