• Title/Summary/Keyword: Partition Wall

Search Result 84, Processing Time 0.026 seconds

A Study on the Development and Application of Movable Partition Components for Facilitating of Long-life Housing (장수명 주택의 활성화를 위한 가동칸막이벽체 개발현황 연구)

  • Lee, Sung-Ok;Kim, Soo-Am
    • Journal of the Korean housing association
    • /
    • v.21 no.6
    • /
    • pp.91-98
    • /
    • 2010
  • The purpose of this study is to develop the feasibility of movable partition wall components that are able to correspond changes of structure system and spatial configuration by the needs of residents for the activation of long-life housing. The key element of various movable partition wall components, a movable partition wall, was analyzed for problems through both as-is analysis and field installation in Korea and Japan, and then its feasibility was verified. The movable partition wall can break the uniformity of a fixed one, can integrate and separate limited space by changes in the demands of residents, can be easy to separate, and can be independent. The development of the movable partition wall is important for the realization of diverse residential space, ease of remodeling, environment adaptation, promotion of modularization, etc. It is comprised of surfacing materials, core materials, structural materials, and movable parts. The domestic movable partition wall was verified regarding the feasibility of an apartment house through on-site inspections and sound insulation tests by KOHP21, KICT. In conclusion, the construction of long-life housing that has sustainable values in the use of housing is nationally an important assignment, so as to secure good housing stock.

A Numerical Study on Effect of a Partition Wall Height on Wind Pressure Load when KTX passes through a Station (한국고속전철(KTX)이 역사를 통과할 때 격벽의 높이에 따른 풍하중의 변화에 대한 수치해석 연구)

  • Cho D.;Hur N.;Kim S. R.
    • Journal of computational fluids engineering
    • /
    • v.6 no.1
    • /
    • pp.56-62
    • /
    • 2001
  • A high speed train passing through a station may have undesired effects to passengers on platform due to abrupt pressure transients. Therefore it is very important to reduce the possible degree of danger by installing partition walls in passing lanes in designing the stations having passing train. In the present study, a pressure load to a passenger on platform is studied for the cases of various heights of the partition wall to assess the effectiveness of the wall on the passenger safety. From the results, it is seen that the pressure load on a passenger may be largely reduced by the partition wall. The heights of the partition wall for various passing speed are also studied based on the safety regulation.

  • PDF

Technical Development for the Circulating Fluidized Bed Combustor of firing Korean Low Grade Anthracite Coals (Particle Flow Patterns in a Circulating Fluidized-Bed with an internal Nozzle and a Partition Wall) (한국산 저질무연탄 연소용 순환식유동층 연소로 개발(간막이벽과 내부노즐을 설치한 순환유동층내에서의 유체거동))

  • Khee, Kwan-Seok
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.6 no.4
    • /
    • pp.243-248
    • /
    • 1993
  • A Circulating Fluidized-Bed (CFB) with an internal nozzle and a partition wall was proposed. The technique of fluidization is related to operations first used commercially in the fields of metallurgical and mechanical engineering such as the heat treatment of metals and power station combustors. In the modified CFB, an internal nozzle and a partition wall were additionally set in the main bed. This cold mode CFB apparatus made of acrylic resin; the main bed is 1,500mm high and 100mm in the inner diameter, the internal nozzle is 130mm high and 10mm in the inner diameter, and the partition wall is 7mm thick and 100mm in the diameter. Glass beads of $89{\mu}m$ in the mean diameter were employed as bed materials.

  • PDF

A Development of Partition Wall for enhenced Sound Transmission Loss and Air Tightness (차음성능과 기밀성능이 향상된 경량 간막이벽 개발)

  • 배상환;박진우;홍천화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.855-860
    • /
    • 2001
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings. it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But. the required performances of a light-weight wall are not evaluated systematically. As a field survey result. partition walls of house-to-house and room-to-room were not showed their respected performances. so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially. occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Also to suppress indoor air movement. stact effect must be concerned. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings.

  • PDF

Evaluation of Sound Insulation Performance of Extruded Cement Panel with a-Hemihydrate Gypsum

  • Kim, Jin-Man;Choi, Duck-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.6
    • /
    • pp.575-585
    • /
    • 2012
  • The extruded cement panel, which has many advantages as a prefabricated method, has been limited in its application due to its low fire-resistance. However, an extruded cement panel produced by mixing a-hemihydrate gypsum offers dramatically improved fire-resistance and is expected to have wide-ranging applications in the construction sector as an interior material or partition wall between housing units. Sound insulation performance is very important for the partition wall between housing units. In this study, the sound insulation performance of the extruded cement panel produced through the mixture of a-hemihydrate gypsum is reviewed in order to determine its usability for a partition wall between housing units and for interior materials. Through the review it was found that the wall formed using the extruded cement panels produced by mixing the a-hemihydrate gypsum have ★★★ class in sound insulation test, equal or superior compared with the other two types of extruded cement panel walls currently available in the market.

EFFECT OF PARTITION AND SPECIES DIFFUSIVITY ON DOUBLE DIFFUSIVE CONVECTION OF WATER NEAR DENSITY MAXIMUM

  • Sivasankaran, S.;Kandaswamy, P.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.11 no.1
    • /
    • pp.71-83
    • /
    • 2007
  • The double diffusive convection of cold water in the vicinity of its density maximum in a rectangular partitioned enclosure of aspect ratio 5 with isothermal side walls and insulated top and bottom is studied numerically. A thin partition is attached to the hot wall. The species diffusivity of the fluid is assumed to vary linearly with concentration. The governing equations are solved by finite difference scheme. The effects of position and height of the partition, variable species diffusivity and enclosure width are analyzed for various hot wall temperatures. It has been found that adding partition on the hot wall reduces the heat transfer. The density inversion of the water has a great influence on the natural convection. When increasing species diffusivity parameter heat and mass transfer rate is decreased.

  • PDF

Partition method of wall friction and interfacial drag force model for horizontal two-phase flows

  • Hibiki, Takashi;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1495-1507
    • /
    • 2022
  • The improvement of thermal-hydraulic analysis techniques is essential to ensure the safety and reliability of nuclear power plants. The one-dimensional two-fluid model has been adopted in state-of-the-art thermal-hydraulic system codes. Current constitutive equations used in the system codes reach a mature level. Some exceptions are the partition method of wall friction in the momentum equation of the two-fluid model and the interfacial drag force model for a horizontal two-phase flow. This study is focused on deriving the partition method of wall friction in the momentum equation of the two-fluid model and modeling the interfacial drag force model for a horizontal bubbly flow. The one-dimensional momentum equation in the two-fluid model is derived from the local momentum equation. The derived one-dimensional momentum equation demonstrates that total wall friction should be apportioned to gas and liquid phases based on the phasic volume fraction, which is the same as that used in the SPACE code. The constitutive equations for the interfacial drag force are also identified. Based on the assessments, the Rassame-Hibiki correlation, Hibiki-Ishii correlation, Ishii-Zuber correlation, and Rassame-Hibiki correlation are recommended for computing the distribution parameter, interfacial area concentration, drag coefficient, and relative velocity covariance of a horizontal bubbly flow, respectively.

Seismic interactions between suspended ceilings and nonstructural partition walls

  • Huang, Wen-Chun;McClure, Ghyslaine;Hussainzada, Nahidah
    • Coupled systems mechanics
    • /
    • v.2 no.4
    • /
    • pp.329-348
    • /
    • 2013
  • This study aims at observing the coupling behaviours between suspended ceilings and partition walls in terms of their global seismic performance using full-scale shake table tests. The suspended ceilings with planar dimensions of $6.0m{\times}3.6m$ were tested with two types of panels: acoustic lay-in and metal clip-on panels. They were further categorized as seismic-braced, seismic-unbraced, and non-seismic installations. Also, two configurations of 2.7 m high partition wall specimens, with C-shape and I-shape in the plane layouts, were tested. In total, seven ceiling-partition-coupling (CPC) specimens were tested utilizing a unidirectional seismic simulator. The test results indicate that the damage patterns of the tested CPC systems included failure of the ceiling grids, shearing-off of the wall top railing, and, most destructively, numerous partial detachments and falling of the ceiling panels. The loss of panels was mostly concentrated near the center of the tested partition wall. The testing results also confirmed that the failure mode of the non-seismic CPC systems was brittle: The whole system would collapse suddenly all at once when the magnitude of the inputs hit the capacity threshold, rather than displaying progressive damage. Overall, the seismic capacity of the unbraced and braced CPC systems could be up to 1.23 g and 2.67 g, respectively; these accelerations were both achieved at the base of the partition wall. Nonetheless, for practical applications, it is noteworthy that the three-dimensional nature of seismic excitations and the size effect of the ceiling area are parameters that exacerbate the CPC's seismic response so that their actual capacity may be dramatically decreased, leading to important losses even in moderate seismic events.

Amendment for Plasterboard Partition Wall of LH Construction Specifications (LH 전문시방서의 석고보드 복합패널 관련 개정(안))

  • Choi, Soo-Kyung;Yoon, Sang-Chun;JI, Suk-Won
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.213-214
    • /
    • 2019
  • In order to apply the drywall system to the interior wall of the post & beam structure, the existing detail drawings and construction specifications must be revised. LH selected drywall systems suitable for post & beam apartment housings and revised their standard detail drawings and construction specifications. This paper describes the major revision of the plasterboard partition wall in the LH construction specifications and standard detail drawings. The main policy of the revision work was to prevent defects by ensuring the construction quality and to eliminate adverse effects on the subsequent processes.

  • PDF

A study on the sound insulation performance of partition wall between units of apartment house (공동주택 세대간 차음성능에 관한 연구)

  • Ju, Mun Ki;Oh, Yang Ki
    • KIEAE Journal
    • /
    • v.10 no.3
    • /
    • pp.51-56
    • /
    • 2010
  • The sound insulation performance is one of the important factor that determined the amenity of housing life in residential building. Especially, Apartment house represents a korea habitation. So the importance of privacy and noise problems between habitable rooms are emphasized in these habitation. This study investigates and find a problem of sound insulation performance of partition wall of the apartment house in current state. The measurements were carried out in apartment house with and without a stair hall. And the measurements also carried out in current state and installing a sound absorbing material in receiving room and changing a front door and installing a inner door. In spite of the same partition wall, difference results were showed according to the stair hall. It is appeared that sound insulation performance without stair hall is 6-7dB(Dw) higher than that with stair hall. In case of without stair hall, sound insulation performance is Dw 49 for single number quantity for airbone sound. And In case of changing a front door and installing a inner door sound insulation performance is Dw 57 for single number quantity for airbone sound. The Results of measuring on the changes a front door and installed a inner door indicated that the flanking sound through front door influenced the sound insulation performance.