• Title/Summary/Keyword: Particulate emission

Search Result 460, Processing Time 0.024 seconds

Effects of Regular Inspection Facility Standards Improvement on Particulate Matter (PM10) Emissions (정기검사 시설기준 개선이 입자상물질(PM10) 배출에 미치는 영향)

  • Choi, Soungkyu;Kim, Yongdal;Lee, Jaeyoung;Kim, Hogyeong;Noh, Kiseong;Park, Jungsoo
    • Journal of Auto-vehicle Safety Association
    • /
    • v.11 no.1
    • /
    • pp.36-39
    • /
    • 2019
  • The particulate matter that was emitted always come up by atmospheric environmental problem. Running on the road vehicles must have regular inspection at regular period and make sure the emissions of exhaust gases exceed the legal standards. Emission test for the atmospheric environment, but it is not free from the particulate matter. Currently, emission test of vehicle inspection is divided into regular inspection and close inspection. Regular inspection and close inspection differ not only the method of emission test, but also the facility standards that must have for this inspection. According to the "Regulations on the Implementation of Comprehensive vehicle Inspection, etc.", close inspection must have trapping device that is trap particulate matter by emission test to vehicle. However, regular inspection is different. Regular inspection do not specify any criteria for trapping facilities. Therefore, this study is confirm how to prevent the emission of particulate matter to the atmosphere during the year when mandatory trapping facilities are required to trapped particulate matter in the regular inspection.

The Study on the Emission Characteristics of HAPs and PM from the Motor Vehicle Paint Facility (자동차 도장시설에서 발생하는 유해대기오염물질 및 미세먼지의 배출특성에 관한 연구)

  • Kim, Han-Na;Bong, Choon-Keun;Kim, Yong-Gu;Jeon, Jun-Min
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.6
    • /
    • pp.713-721
    • /
    • 2013
  • This study is about emission characteristics of HAPs and particulate matters emitted by spray of paint and organic solvent usually used in vehicle paint facilities. To analyze emission characteristics of HAPs and particulate matters emitted from vehicle paint facilities are calculated based on the measuring emission quantity of pollutants based on the amount of paint used (kg) and unit area ($m^2$) by paint manufacturers (J company, K company, and R company). In cases of paint manufacturers (J, K, and R), average emission factors of VOCs, carbonyl compound, particulate matter, and PAHs per 1 kg of paint were 327.81 g/kg, 5.98 g/kg, 336.70 g/kg, and 0.0078 g/kg respectively. The average emission factors of VOCs, carbonyl compounds, particulate matters, and PAHs by unit area were $171.55g/m^2$, $3.10g/m^2$, $176.27g/m^2$, and $0.0036g/m^2$ respectively.

Study on Performance and An Exhaust Emission by Bio-Diesel Deterioration and Engine Load Rate at Heavy-Duty Diesel Engine (대형디젤기관에서 바이오디젤 열화와 엔진부하에 따른 배출가스특성 및 성능에 관한 연구)

  • Park, Man-Jae;Kim, Mi-Soo
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.3
    • /
    • pp.56-63
    • /
    • 2007
  • Modern diesel vehicle has to comply with the EURO IV, V regulation with low level of particulate matter and smoke emission Moreover, emission standards of each countries are becoming stringent in advanced countries such as USA and Europe. Because Bio-diesel is similar to diesel fuel, it is essential to judge the environmental and health effects deriving from the use of Bio-diesel in diesel engine. The deterioration characteristics of emission in accordance with aging vehicles must be regulated for Bio-diesel. Therefore, under 1200 driving hours, 220,000km driving distance condition and full load, the deterioration characteristics of emission were estimated. We could reduce sulfur contents of fuel, particulate matter and smoke emission by using Bio-diesel and conform the influence of engine performance, emission, and fuel consumption by Bio-diesel deterioration

Distribution of Concentration and Emission of Dust according to Types of Poultry Buildings in Korea (국내 계사(鷄舍) 작업장 유형에 따른 분진 농도 및 발생량 분포)

  • Kim, Ki Youn
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.3
    • /
    • pp.185-193
    • /
    • 2017
  • Objectives: An on-site study was conducted in order to quantify indoor exposure levels and the emission rate of particulate matter for domestic poultry buildings. Materials and methods: Three types of poultry building (caged layer house, broiler house, and layer house with manure belt) as classified by mode of manure treatment and ventilation were investigated in this study. Nine sites per each poultry building were selected and visited for measuring exposure levels and emission rate of particulate matter. Total dust and respirable dust among the particulate matter were analyzed based on the weight method. Emission rates were estimated by dividing emission amount, which was calculated through multiplying indoor concentration ($mg/m^3$), by the ventilation rate ($m^3/h$), into indoor area ($m^2$) and number of poultry reared in the poultry building. Results: Mean exposure levels for total dust and respirable dust in the poultry buildings were $3.91({\pm}1.99)mg/m^3$ and $1.99({\pm}0.89)mg/m^3$, respectively. The emission rates of particulate matter in the poultry buildings were estimated as $4.75({\pm}1.22)mg\;head^{-1}h^{-1}$ and $64.39({\pm}24.95)g\;m^{-2}h^{-1}$ for total dust and $0.58({\pm}0.23)mg\;head^{-1}h^{-1}$ and $7.52({\pm}2.51)mg\;m^{-2}h^{-1}$ for respirable dust, respectively. The distribution patterns for total dust and respirable dust were similar regardless of poultry building type. Among poultry buildings, broiler house showed the highest exposure level and emission rate of total dust and respirable dust, followed by layer house with manure belt and caged layer house. Conclusions: The finding that the broiler house showed the highest exposure level and emission rate of particulate matter can be attributed to sawdust utilized as bedding material, which can be dispersed into the air by movements of the chickens. Thus, a work environmental management solution for optimally reducing dust concentrations is necessary for broiler houses.

PM10 Emission Estimation from LNG G/T Power Plants and Its Important Analysis on Air Quality in Incheon Area (인천 지역 LNG G/T발전소의 미세먼지 (PM10) 배출량 평가 및 주변 대기질 영향 분석)

  • Gong, Bu-Ju;Park, Poong-Mo;Dong, Jong-In
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.5
    • /
    • pp.461-471
    • /
    • 2015
  • Base on emission factors derived from National Institute of Environmental Research, Particulate matter from combined cycle power plants (CCPPs) has been estimated to be a important source of $PM_{10}$. Generally there is no serious emission of particulate matter in CCPPs. because the fuel of them is natural gas. But emission gas after long shut down season has very high dust content. Therefore $PM_{10}$ emission rate is dependent on its operation mode. In this study, particulate dispersion study for new city near CCPPs complex has performed using CALPUFF model for three case. $PM_{10}$ concentration has big difference between normal operation and 2 case start-up condition after long shutdown. In normal operating conditions, daily $0.32{\sim}0.50{\mu}g/m^3$ influence on of the surrounding area. But when 1~2 aerobic high concentration discharged conditions, average concentration is higher about $9.2{\sim}34.1{\mu}g/m^3$ than normal operating conditions.

Emission Characteristics of Particulate Matters from Under-fired Charbroiling Cooking Process using the Hood Method (Hood Method를 이용한 직화구이 음식점의 미세먼지 배출 특성)

  • Lee, Jun-Bok;Kim, Heung-Joo;Jung, Kweon;Kim, Shin-Do
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.4
    • /
    • pp.315-321
    • /
    • 2009
  • Under-fired charbroiling cooking processes are known as important contributors of particulate matter (PM). In this study, we characterized the emission of particulate matters from under-fired charbroiling cooking processes using the hood method. Accumulated mass concentration of $PM_{10}$ was 92.2~99.5% and particle size of 2.0~2.5 ${\mu}m$ was highest. The concentration of PM increased very sharply at the beginning of charbroiling meats and then gradually decreased as the charbroiling continued. PM concentration also increased very sharply when gravy from meat spilled onto the frame of fire. However, mass concentration during charbroiling using only charcoals was very low compared to that of meats. We estimated the emission factors of charcoal, pork belly and pork shoulder respectively; 0.01~0.02 g/kg, 5.02~6.26 g/kg, 2.86~4.15 g/kg of $PM_{2.5}$, 0.01~0.03 g/kg, 7.44~7.91 g/kg, 4.54~5.56 g/kg of $PM_{10}$, and 0.02~0.05 g/kg, 7.59~7.95 g/kg, 4.93~5.68 g/kg of TSP. The emission factors of charcoal were negligible and the emission factors of pork belly were higher than that of pork shoulder. Emission rates of particulate matters from under-fired charbroiling cooking process were estimated as 578,009~1,265,152 kg/yr of $PM_{2.5}$, 917,539~1,598,619 kg/yr of $PM_{10}$ and 996.358~1,606,703 kg/yr of TSP. But emission factors should be verified with an in-stack cascade impactor because the reported method involves some assumptions.

Influence of Aftertreatment System on the Size Distribution of Diesel Exhaust Particulate Matter (후처리 장치에 의한 디젤엔진 배출가스의 미세 입자 입경분포 변화)

  • 권순박;김민철;이규원;류정호;엄명도;김종춘;정일룩
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.7
    • /
    • pp.113-121
    • /
    • 1999
  • Diesel particulate matter is known to be one of the major harmful emissions produced by diesel engines. Diesel particulates are subject to diesel emission regulations and have lately become the focus in the diesel emission control technology. Thus, the aftertreatment system is adopted at the diesel engine exhaust to reduce the particulate emission. Although this benefit is recognized, it is not clear how the aftertreatment system influences quantitatively the particle size distribution distribution. In this study, the particle size distributions of diesel exhaust were measured using the scanning mobility particle sizer with and without the aftertreatment system. There results showed that the diesel particulate filter and plasm system reduced the number of emitted particles by more than 90% and about 80% respectivley in the particle size range of 20nm∼600nm. On the other hand no significant effect of the diesel oxidation catalyst on the particle number concentration was detected.

  • PDF

A Study on Green Space Location Selection to Reduce Particulate Matter by Projecting Distributions of Emission Source and Vulnerable Groups - focusing on Seongdong-gu, Seoul - (미세먼지 배출원과 취약계층 분포 추정을 통한 미세먼지 저감 녹지 입지 선정 연구 - 서울시 성동구를 대상으로 -)

  • Shin, Ye-Eun;Park, Jin-Sil;Kim, Su-Yeon;Lee, Sang-Woo;An, Kyung-Jin
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.24 no.1
    • /
    • pp.53-68
    • /
    • 2021
  • The study aims to propose a locating method of green space for reducing Particulate Matter (PM) in ambient air in conjunction with its source traces and vulnerable groups. In order to carry out the aims and purposes, a literature review was conducted to derive indicators of vulnerable area to PM. Based on the developed indicators, the vulnerable areas and green spaces creation strategies for each cluster were developed for the case of Seongdong-gu, Seoul. As a result, six indicators for vulnerability analysis were came out including the vulnerable groups (children's facilities, old people's facilities), emission sources (air pollutant emission workplaces, roads), and environmental indicators (particulate matter concentration, NDVI). According to the six selected indicators, the target area was divided into 39 hexagons and analyzed to result the most vulnerable areas to particulate matter. As a result of comprehensive vulnerability analysis, the Seongsu-dong area was found to be the most vulnerable to particulate matter, and 5 clusters were derived through k-means cluster analysis. Cluster 1 was analyzed as areas that most vulnerable to particulate matter as a result of the comprehensive analysis, therefore urgent need to create green spaces to reduce particulate matter. Cluster 2 was areas that mostly belonged to the Han River. Cluster 3 corresponds to the largest number of hexagons, and since many vulnerable groups are distributed, it was analyzed as a cluster that required the creation of a green spaces to reduce particulate matter, focusing on facilities for vulnerable groups. Three hexagons are included in cluster 4, and the cluster has many roads and lacks vegetation in common. Cluster 5 has a lot of green spaces and is generally distributed with fewer vulnerable groups and emission sources; however, it has a high level of particulate matter concentration. In a situation where various green spaces creation projects for reducing particulate are being implemented, it is necessary to consider the vulnerable groups and emission sources and to present green space creation strategies for each space characteristic in order to increase the effectiveness of such projects. Therefore, this study is regarded as meaningful in suggesting a method for selecting a green area for reducing PM.

A Study on the Emission and Dispersion of Particulate Matter from a Cement Plant (한 시멘트공장의 분진발생과 대기확산에 관한 조사연구)

  • Chang, Man-Ik;Chung, Yong;Kwon, Sook-Pyo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.16 no.1
    • /
    • pp.67-77
    • /
    • 1983
  • To investigate the an air pollution by particulate matter and its dispersion, a cement plant produceing portland cement 600,000 ton/year and its vicinity were surveyed from Obtober, 1980 to April, 1983. The survey was mainly focused on main stack emmission rate of the cement plant and particle size distribution in the dust, dustfall and total suspended particulate concentration in the area by month and distance from the stack. The results of the study were as follows; 1. The main stack emission rate was surveyed before and after the spray tower was additionally installed to the original E.P bag filter. Before the spray tower installed, the main stack emission rate was higher ($0.64g/Nm^3$) than the emission standard of Korean Environmental Preservation Law's ($0.59g/Nm^3$, amended to $0.4g/Nm^3$ on April 1983), but after the spray tower was installed, its main stack emission rate was markedly decreased to the standard ($0.43g/Nm^3$). 2. $2{\sim}3{\mu}m$ of the particle size was the largest portion (20.8%) of the dust particulate from the main stack and 50% of the frequency distribution was $1.5{\mu}m$ of the size. Most particle size was below $10{\mu}m$. 3. The spray tower reduced the dustfall to $37.81{\sim}9.76\;ton/km^2/month$ while dustfall appeared at $45.29-15.45ton/km^2/month$, in the vicinity of plant before spray tower installed 4. Mean concentrations of total suspended particulate for 24 hours of the various stations were determined in $20.6-200.0{\mu}g/m^3$, 3 stations of tham were higher than the value of Harry and William's arthmetic average standard $130{\mu}g/m^3$. 5. Linear regression between dustfall [X] and total suspended particulate[Y] concentration was an equation, Y=4.024X+11.479.[r=0.91] 6. During the whole seasons in the opposite area 100m apart from the omission source the prevailing wind direction was with estimated more than $30ton/km^2/month$, and the concentration of total suspended particulate for 24 hours averaging time was more than $140{\mu}g/m^3$ in the same area and direction. 7. Assuming the wind direction were constant through the day dustfalls for a day were estimated at $13.40ton/km^2/day,\;10.79ton/km^2/day$ and $4.55ton/km^2/day$ at various distances of 100m, 500m and 1,500m from the emission source respectively. 8. In the simutalion of dustfall and suspended dust by area, Gaussian dispersion model modified by size distribution of particulate matter was not applicated since the emission of dust were from multi sources other them stack. From the above results, it could be applied that the dispersion of dust from the cement plant is estimated and regulated for the purpose of environmental protection.

  • PDF

A Study on the Performance and Particulate Emission Characteristics for the Hydrogen-Premixed Diesel Engine (수소 혼소 디젤 기관의 성능 및 미립자상 물질의 배출 특성에 관한 연구)

  • 채재우;한동성;이상만;전영남;정영식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.2
    • /
    • pp.34-41
    • /
    • 1993
  • In order to reduce harmful substances such as particulates and nitric oxides emitted from diesel engine, man kinds of methodology like high pressure spray of diesel fuel oil, exhaust gas recirculation, emulsified fuel usage and dual fuelling have been studied. Dual fuelling of a diesel engine with hydrogen which is well-known as the clean fuel and has excellent combustibility is expected to be effective in reducing harmful substances from diesel engine. This experimental study was conducted to investigate the effect of premixed hydrogen with intake air on the performance and particulate emission characteristics using a single cylinder, prechamber type diesel engine. As a result, it was clarified that a hydrogen-premixed diesel engine can be operated in the state of lower particulate emission and slightly aggravated fuel economy, compared with the conventional diesel engine.

  • PDF