• Title/Summary/Keyword: Particulate Contaminants

Search Result 51, Processing Time 0.021 seconds

Removal of tar and particulate from gasification process using pre-coating technology (바이오매스 가스화 공정의 생성가스 중 타르 및 입자 제거를 위한 pre-coating 기술 연구)

  • Kim, Joon-Yub;Choi, Byoung-Kwon;Jo, Young-Min;Kim, Sang-Bum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.804-815
    • /
    • 2019
  • Due to the depletion and environmental problems of fossil fuel, biomass has arisen as an alternative energy source. Biomass is a renewable and carbon-neutral source. However, it is moister and has lower energy density. Therefore, biomass needs thermal chemical conversion processes like gasification, and it does not only produce a flammable gas, called 'syngas', which consists of CO, H2, and CH4, but also some unwanted byproducts such as tars and some particulates. These contaminants are condensed and foul in pipelines, combustion chamber and turbine, causing a deterioration in efficiency. Thus this work attempted to find a method to remove tars and particles from syngas with a filter which adopts a pre-coating technology for preventing blockage of the filter medium. Hydrated limestone powder and activated carbon(wood char) powder were used as the pre-coat materials. The removal efficiency of the tars was 86 % and 80 % with activated carbon(wood char) coating and hydrated limestone coating, respectively.

Temporal and Spatial Variation and Characteristics of Ambient Air Quality in Urban Areas in Gyeonggi Province (경기도 도시지역 환경대기질의 시공간적 추이와 특성)

  • Kim, Jong-Chan
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.3
    • /
    • pp.269-276
    • /
    • 2012
  • Objectives: The purpose of this study was to provide policy directions for air pollution reduction by analyzing the variation in the characteristics of air contaminants around the Gyeonggi Province area. Methods: The data used in the study was obtained from air quality monitoring stations operated by the Gyeonggi Provincial Government. The target area was the air quality management area of the Gyeonggi Province region. Results: The concentration of $PM_{10}$ (particles measuring $10{\mu}m$ or less) in 2009 was $60{\mu}g/m^3$, which has been reduced by about 2.7% per year after improvement countermeasures were emplaced. The air pollution control policy was especially more effective for coarse particulate matter (CPM, $PM_{10-2.5}$). The improvement of $NO_2$ pollution was generally very low, especially in cities which had considerable automobile traffic. The concentration of $SO_2$ pollution was rapidly improved in industrial areas, but did not show any difference for multiple and general cities. The predicted concentration of $PM_{10}$ for 2014 based on the trend over 2001-2009 was $53.4{\mu}g/m^3$, which fails to meet the target concentration of $40{\mu}g/m^3$. The predicted concentration of $NO_2$ shows a very low probability of achieving the target concentration of 22 ppb, and thus the current improvement of air quality has proven unsatisfactory. Conclusion: Air pollution control policy should be enforced according to regional pollution characteristics in order to obtain maximum effectiveness in improvement.

Economical Ventilation Effectiveness to Reduce Hazardous Chemical Emissions for a Nail-Salon Worker

  • KWON, Woo-Taeg;JUNG, Min-Jae;LEE, Woo-Sik;KWON, Lee-Seung;SO, Young-Jin
    • Journal of Distribution Science
    • /
    • v.17 no.7
    • /
    • pp.65-76
    • /
    • 2019
  • Purpose - The purpose of this study is to investigate economical ventilation effectiveness to reduce hazardous materials exposure and damage of workers by analyzing exposure amount of noxious substances under various ventilation conditions of nail salon for indoor environments. Research design, data, and methodology - This study was carried out with cooperation of Nail shop located in SeongNam city to involve an analysis of the environmental impact indoor air quality, pollutant exposure and economical cost-effectiveness in the nail workplace. The hazardous substances were PM-10(Particulate Matter-10㎛), VOCs(Volatile Organic Compounds) and Formaldehyde, which are the major materials of nail workplace. Results - PM-10 is reduced by about 60% with air cleaner, forced artificial ventilation by 32%, and natural ventilation by about 12%. TVOCs and Formaldehyde showed similar efficiency (80~100%) after natural ventilation and ventilation after 60 minutes. The removal efficiencies of VOCs and formaldehyde were similar to those of natural ventilation and mechanical ventilation system. However, in case of dust, natural ventilation was reduced by artificial ventilation system due to inflow of external dust during natural ventilation. Conclusions - If the pollution degree of outdoor air is not high, air volume is high, and natural ventilation is performed when the air conditioning and heating system is not operated. Even at the end of the work, it keeps operating for 60 minutes to remove the pollutants generated. Results of this analysis demonstrated that the worker environment can be improved by adopting institutional legislation and guidelines for ventilation.

Evaluation of Workplace Protection Factors for Some Half-Facepiece Respirators in Welding Workplace (일부 반면형 호흡기 보호구에 대한 용접작업장에서의 Workplace Protection Factors(WPF) 평가)

  • Byeon, Sang-Hoon;Na, Myung-Chai;Kim, Hyunwook;Lim, Ho-Sub
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.1
    • /
    • pp.14-22
    • /
    • 1999
  • This study was conducted to evaluate workplace protection factors(WPF) for two half-facepiece respirators (HR-1, HR-2) in welding workplace and to provide data on the workplace performance of negative-pressure, half-facepiece respirators against airborne particulate contaminants. The outside iron oxide(Fe2O3) concentration of welding fume for the respirator HR-1 ranged from 0.177 to $12.508mg/m^3$ with a geometric mean of $1.118mg/m^3$ and the HR-2 respirator showed a iron oxide range of 0.500 to $3.494mg/m^3$ with a geometric mean of $1.082mg/m^3$. But the inside oxide concentration of welding fume for the respirator HR-1 ranged from 0.002 to $0.364mg/m^3$ with a geometric mean of $0.019mg/m^3$ and the HR-2 respirator showed a iron oxide range of 0.012 to $0.639mg/m^3$ with a geometric mean of $0.041mg/m^3$. The iron oxide inside concentrations were significantly less than $5mg/m^3$(TLV) for both of respirators. The WPF were ranged from 3 to 3744 with a geometric mean of 60 for HR-1 and range from 2 to 129 a geometric mean of 26 for HR-2. And, in this study, the 5th percentile of the workplace protection factors for half-facepiece aspirators (HR-1, HR-2) were 11.2 and 7.1, respectively. The correlation relationship between the Quantative Fit Factors(QNFT) and the WPF for half-mask negative pressure respirators were 0.099 and 0.460.

  • PDF

Enhancing the Intrinsic Bioremediation of PAH-Contaminated Anoxic Estuarine Sediments with Biostimulating Agents

  • Bach Quang-Dung;Kim Sang-Jin;Choi Sung-Chan;Oh Young-Sook
    • Journal of Microbiology
    • /
    • v.43 no.4
    • /
    • pp.319-324
    • /
    • 2005
  • Estuarine sediments are frequently polluted with hydrocarbons from fuel spills and industrial wastes. Polycyclic aromatic hydrocarbons (PAHs) are components of these contaminants that tend to accumulate in the sediment due to their low aqueous solubility, low volatility, and high affinity for particulate matter. The toxic, recalcitrant, mutagenic, and carcinogenic nature of these compounds may require aggressive treatment to remediate polluted sites effectively. In petroleum-contaminated sediments near a petrochemical industry in Gwangyang Bay, Korea, in situ PAH concentrations ranged from 10 to 2,900 ${\mu}g/kg$ dry sediment. To enhance the biodegradation rate of PAHs under anaerobic conditions, sediment samples were amended with biostimulating agents alone or in combination: nitrogen and phosphorus in the form of slow-release fertilizer (SRF), lactate, yeast extract (YE), and Tween 80. When added to the sediment individually, all tested agents enhanced the degradation of PAHs, including naphthalene, acenaphthene, anthracene, fluorene, phenanthrene, fluoranthene, pyrene, chrysene, and benzo [a] pyrene. Moreover, the combination of SRF, Tween 80, and lactate increased the PAH degradation rate 1.2-8.2 times above that of untreated sediment (0.01-10 ${\mu}g$ PAH/ kg dry sediment/day). Our results indicated that in situ contaminant PAHs in anoxic sediment, including high molecular weight PAHs, were degraded biologically and that the addition of stimulators increased the biodegradation potential of the intrinsic microbial populations. Our results will contribute to the development of new strategies for in situ treatment of PAH-contaminated anoxic sediments.

CFD simulation of cleaning nanometer-sized particulate contaminants using high-speed injection of micron droplets (초고속 미세 액적 충돌을 이용한 나노미터 크기 입자상 오염물질의 세정에 대한 CFD 시뮬레이션)

  • Jinhyo, Park;Jeonggeon, Kim;Seungwook, Lee;Donggeun, Lee
    • Particle and aerosol research
    • /
    • v.18 no.4
    • /
    • pp.129-136
    • /
    • 2022
  • The line width of circuits in semiconductor devices continues to decrease down to a few nanometers. Since nanoparticles attached to the patterned wafer surface may cause malfunction of the devices, it is crucial to remove the contaminant nanoparticles. Physical cleaning that utilizes momentum of liquid for detaching solid nanoparticles has recently been tested in place of the conventional chemical method. Dropwise impaction has been employed to increase the removal efficiency with expectation of more efficient momentum exchange. To date, most of relevant studies have been focused on drop spreading behavior on a horizontal surface in terms of maximum spreading diameters and average spreading velocity of drop. More important is the local liquid velocity at the position of nanoparticle, very near the surface, rather than the vertical average value. In addition, there are very scarce existing studies dealing with microdroplet impaction that may be desirable for minimizing pattern demage of the wafer. In this study, we investigated the local velocity distribution in spreading liquid film under various impaction conditions through the CFD simulation. Combining the numerical results with the particle removal model, we estimated an effective cleaning diameter (ECD), which is a measure of the particle removal capacity of a single drop, and presented the predicted ECD data as a function of droplet's velocity and diameter particularly when the droplets are microns in diameter.

Filtration Efficiency of Granular Activated Carbons to Polydisperse Ultrafine Particles through the Surface Adsoprtion (그래뉼 타입 활성탄 필터의 100 나노 미만 다분산 초미세먼지 표면흡착 제거 효율 연구)

  • Cho, Kyungil;Kang, Giwon;Shin, Jiyoon;Kim, Changhyuk
    • Particle and aerosol research
    • /
    • v.18 no.3
    • /
    • pp.79-86
    • /
    • 2022
  • Many commercial air purifiers currently have deployed granular activated carbon (GAC) filters for removing volatile organic compounds in the indoor air. GACs are generally used to remove gaseous contaminants in the air through adsorption by the inner surfaces of pores. In addition, airborne particles can be also filtered by the surface adsorption of the GACs, which can improve the life-time of the particulate filters. In this study, the filtration efficiency of GACs to ultrafine particles through surface adsorption was investigated at different volume flow rates by deploying a continuous particle filtration system. The polydisperse sodium chloride (NaCl) particles were generated by a set of an atomizer and a diffusion dryer, and then mixed with particle-free air at different volume flow rates. The penetration of ultrafine particles and pressure drop for each experimental condition were measured to figure out the effect of the volume flow rate on the surface adsoprtion of the GACs to particles, ~ 2 mm. The particle filtration efficiency of the GACs decreased as the volume flow rate increased from 4 to 14 lpm. However, the 5 times thicker GAC filter layer decreased the penetration of ultraparticles than a preious study. The filtration efficiency of the single granule was also higher than the previous result in the literature with smaller granule filter materials.

Evaluation of Air Quality in the Compost Pilot Plant with Livestock Manure by Operation Types (축분 퇴비화시스템 운용방식에 따른 실내 대기오염 평가)

  • Kim, K.Y.;Choi, H.L.;Ko, H.J.;Kim, C.N.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.283-294
    • /
    • 2004
  • Air quality in the livestock waste compost pilot plant at the Colligate Livestock Station was assessed to quantity the emissions of aerial contaminants and evaluate the degree of correlation between them for different operation strategies; with the ventilation types and agitation of compost pile, in this study. The parameters analyzed to reflect the level of air quality in the livestock waste compost pilot plant were the gaseous contaminants; ammonia, hydrogen sulfide, and odor concentration, the particulate contaminants; inhalable dust and respirable dust, and the biological contaminants; total airborne bacteria and fungi. The mean concentrations of ammonia, hydrogen sulfide, and odor concentration in the compost pilot plant without agitation were 2.45ppm, 19.96ppb, and 15.8 when it was naturally ventilated, and 7.61ppm, 31.36ppb, and 30.2 when mechanically ventilated. Those with agitation were 5.50ppm, 14.69ppb, and 46.4 when naturally ventilated, and 30.12ppm, 39.91ppb, and 205.5 when mechanically ventilated. The mean concentrations of inhalable and respirable dust in the compost pilot plant without agitation were 368.6${\mu}g$/$m^3$ and 96.0${\mu}g$/$m^3$ with natural ventilation, and 283.9${\mu}g$/$m^3$ and 119.5${\mu}g$/$m^3$ with mechanical ventilation. They were also observed with agitation to 208.7${\mu}g$/$m^3$ and 139.8${\mu}g$/$m^3$ with natural ventilation, and 209.2${\mu}g$/$m^3$ and 131.7${\mu}g$/$m^3$ with mechanical ventilation. Averaged concentrations of total airborne bacteria and fungi in the compost pilot plant without agitation were observed to 28,673cfu/$m^3$ and 22,507cfu/$m^3$ with natural ventilation, and 7,462cfu/$m^3$ and 3,228cfu/$m^3$ with mechanical ventilation. They were also observed with agitation to 19,592cfu/$m^3$ and 26,376cfu/$m^3$ with the natural ventilation, and 18,645cfu/$m^3$ and 24,581cfu/$m^3$ with the mechanical ventilation. It showed that the emission rates of gaseous pollutants, such as ammonia, hydrogen sulfide, and odor concentration, in the compost pilot plant operated with the mechanical ventilation and with the agitation of compost pile were higher than those with the natural ventilation and without the agitation. While the concentrations of inhalable dust and total airborne bacteria in the compost pilot plant with the natural ventilation and with the agitation, the concentrations of respirable dust and total airborne fungi in the compost pilot plant with the mechanical ventilation and agitation were higher than those with the natural ventilation and without the agitation of compost pile. It was statistically proved that indoor temperature and relative humidity affected the release of particulates and biological pollutants, and ammonia and hydrogen sulfide were believed primary malodorous compounds emitted from the compost pilot plant.

Characteristics of indoor air quality in the overground and underground railway stations (지상과 지하역사의 실내공기질 특성과 외기영향 평가)

  • Namgung, Hyeong-Kyu;Song, Ji-Han;Kim, Soo-Yeon;Kim, Hee-Man;Kwon, Soon-Bark
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.17-25
    • /
    • 2016
  • In this study, the air quality of underground and overground railway stations was evaluated focusing on the degree of influence of the outside air quality. The measured components were particulate matter ($PM_{10}$), carbon dioxide ($CO_2$), carbon monoxide (CO), nitrogen dioxide ($NO_2$), formaldehyde (HCHO), ozone ($O_3$), total airborne bacteria (TAB), total volatile organic carbon (TVOC), and Radon (Rn), which are included in the maintenance standards and recommended standards of the Indoor Air Quality Management Act. Also, the indoor/outdoor concentration ratios of $PM_{10}$, $NO_2$, and $O_3$ were calculated to estimate the influence of the outdoor air quality. The concentrations of $PM_{10}$ HCHO, TVOC, $NO_2$, and Rn in the underground stations were found to be higher than those in the overground stations. These results indicate that the (present) generation of contaminants are caused by the indoor source of the underground station. The ozone concentration of the overground stations was higher than that of the underground stations, which indicates that the outdoor ozone concentration influenced that of the overground stations directly. Thus, methods of improving the IAQ should take into consideration the types of contamination.

Exposure Assessments of Environmental Contaminants in Ansim Briquette Fuel Complex, Daegu(I) - Effect zone of environmental pneumoconiosis and fugitive dust - (대구 안심연료단지 환경오염물질 노출 평가(I) - 환경성 진폐증 및 비산먼지 영향권역 -)

  • Jung, Jong-Hyeon;Oh, In-Bo;Phee, Young-Gyu;Nam, Mi-Ran;Hwang, Mi-Kyoung;Bang, Jin-Hee;Jeon, Soo-Bin;Lee, Sang-sup;Yu, Seung-do;KimS, Byung-Seok;Yoo, Seok-Ju;Lee, Kwan;Lim, Hyun-Sul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.366-379
    • /
    • 2015
  • Objectives: The objective of this study is to assess airborne particulate matter(PM) pollution and its effect on health of residents living near Ansim Briquette Fuel Complex in Daegu metropolitan region. Methods: The California Puff(CALPUFF) dispersion model, version 5.8, which can estimate the dispersion direction and range of airborn $PM_{10}$ was used to determine the possible areas affected by $PM_{10}$ pollutants emitted from Ansim briquette fuel complex. The CALPUFF modeling with 200 m grid-cell resolution was performed based on $PM_{10}$ emissions estimated from the amount of coal consumption in the fuel complex for four months in 2012. The Weather Research and Forecasting(WRF) fields were processed using CALMET to produce CALPUFF-ready meteorological inputs. Also, the distance from Ansim Briquette Fuel Complex to the residence of each environmental pneumoconiosis patient was analyzed. In addition, the affecting region of the pollutants emitted from briquette factories in Ansim Briquette Fuel Complex was determined. Results: CALPUFF modeling results showed that the highest concentrations of $PM_{10}$ were found near around the fuel complex. The modeled $PM_{10}$ distributions were characterized by significant decreases in concentration with distance from the complex. Seasonally, the highest concentration of $45{\mu}g/m^3$ was calculated in October which was mostly due to the distinct variation of amount of emission. Additional modeling with the maximum $PM_{10}$ emission of about 88 tons per year in 1986 showed that the highest concentration in October was nearly increased by 8 times than the concentration modeled with emission of 2010. As a result of medical examination and interviews for the residents in Ansim Briquette Fuel Complex and its surroundings, 8 environmental pneumoconiosis patients were found. These patients do not have occupational exposure and history. These patients have lived 0.3~1.1 km area in Ansim Briquette Fuel Complex and its surroundings. Conclusions: Airborne particles emitted from Ansim Briquette Fuel Complex can contribute to significant increase in $PM_{10}$ concentration in residential areas near around the complex. Especially, the residents near fuel complex may exposed to the pollutants emitted from the factories in Ansim Briquette Fuel Complex.