• Title/Summary/Keyword: Particulate Concentration

Search Result 945, Processing Time 0.022 seconds

Influence of Aftertreatment System on the Size Distribution of Diesel Exhaust Particulate Matter (후처리 장치에 의한 디젤엔진 배출가스의 미세 입자 입경분포 변화)

  • 권순박;김민철;이규원;류정호;엄명도;김종춘;정일룩
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.7
    • /
    • pp.113-121
    • /
    • 1999
  • Diesel particulate matter is known to be one of the major harmful emissions produced by diesel engines. Diesel particulates are subject to diesel emission regulations and have lately become the focus in the diesel emission control technology. Thus, the aftertreatment system is adopted at the diesel engine exhaust to reduce the particulate emission. Although this benefit is recognized, it is not clear how the aftertreatment system influences quantitatively the particle size distribution distribution. In this study, the particle size distributions of diesel exhaust were measured using the scanning mobility particle sizer with and without the aftertreatment system. There results showed that the diesel particulate filter and plasm system reduced the number of emitted particles by more than 90% and about 80% respectivley in the particle size range of 20nm∼600nm. On the other hand no significant effect of the diesel oxidation catalyst on the particle number concentration was detected.

  • PDF

Characteristics and Management of Particulate Matter(PM2.5) Emission on Cooking Condition (주방 조리시 미세먼지(PM2.5) 배출 특성과 관리방안)

  • Lee, Myeonggu;Jeong, Myeongjin;Kang, Minji
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.1
    • /
    • pp.325-329
    • /
    • 2018
  • There are many pollutants in the residential space due to building materials, ventilation, cooking, etc. Among them, particulate matter is a primary carcinogen and very harmfull to the human body, it occurs mostly in cooking. Therefore, in order to manage the indoor air quality well, it is necessary to evaluate the relationship between the concentration of particulate matter generated during cooking and ventilation method. In this study, we propose a management method and particulate matte which occurs during the kitchen cooking by measuring and analyzing the concenteation change of particulate matter(PM2.5) according to the type of food and the ventilation method.

Experimental Study on Estimation of Oxidation Rate of PM inside of Diesel Particulate Filter (DPF내 포집된 입자상 물질의 산화율 산출을 위한 실험적 연구)

  • Shim, Beomjoo;Park, Kyoungsuk;Jo, Kyuhee;Lee, Hyeongjun;Min, Byeongdu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.2
    • /
    • pp.98-103
    • /
    • 2013
  • Conventional method to estimate mass of particulate matter accumulated in diesel particulate filter is to use pressure difference between upstream and downstream of the filter. Then measured pressure difference should be compared that of clean condition which is no particulate matter accumulated in DPF. During regeneration soot oxidation is also estimated by same method. This methodology, however, has demerit on accuracy because of pressure difference deviation of clean DPFs and pressure difference caused by non-carbon based PM which is different from that of caused by carbon based PM. This study suggests new methodology to estimate accumulated soot oxidation rate through exhaust gas characteristics during regeneration. Results, more high accuracy of soot oxidation was obtained by analysis of relationship between fuel mass and concentration of carbon dioxide and oxygen.

The Relationship between Particular Matter Reduction and Space Shielding Rate in Urban Neighborhood Park (도시근린공원 미세먼지(PM)저감과 공간차폐율과의 관계 - 대구광역시 수성구 근린공원을 중심으로 -)

  • Koo, Min-Ah
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.47 no.6
    • /
    • pp.67-77
    • /
    • 2019
  • The purpose of this study is to analyze how much particulate matter at the center of the urban park is reduced compared to the entrance of the park, where the particulate matter problem is serious. It also endeavored to analyze the relationship between the space closure rate and particulate matter reduction rate in the center of the park through the collection and analysis of experimental data. Seven flat land type urban neighborhood parks in Suseong-gu, Daegu were measured at the same place for three days. The research results are as follows. First, the center of the urban neighborhood park had an average temperature 1.05℃ lower than at the entrance and an average humidity of 2.57% higher. Second, the rate of fine dust reduction was PM1- 17.09%, PM2.5- 17.65%, PM10- 14.99%. As for the reduction rate of particulate matter, the smaller the size of the park, the greater the reduction rate. In addition, the reduction rate at the center of the park was lower on days when particulate matter concentration based on the weather reports was low. The higher the concentration at the park entrance, the higher the reduction rate was. Third, a higher the rate of space closures at the center of the park resulted in a higher effect of particulate matter reduction. Noting this, the relationship between particulate matter reduction and the space closure rate in urban neighborhood parks was clearly shown. We hope to be the basis for more extensive experimental data collection.

Quantitative Source Estimation of Particulate Matters in Suwon Area Using the Target Transformation Factor Analysis Based on Size Segregation Scheme (입경 분류에 입각하여 목표변환 인자분석법을 이용한 수원지역 분진 오염원의 정량적 기여도 추정)

  • 김동술;이태정
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.1
    • /
    • pp.44-50
    • /
    • 1993
  • The suspended particulate matters had been collected by a cascade impactor having 9 size fragnated stages for 2 years (Dec. 1989 to Nov. 1991) in Kyung Hee University-Suwon Campus. The particulate matters were then collected on each stage by membrane filters. The weight concentration on each stage was estimated by a microbalance and further chemical element concentrations were determined by an XRF system. The study focused on developing of a receptor model using the TTFA (target transformation factor analysis) to apportion aerosol mass with the 30 ambient data sets. Each data set consists of the 8 size-ranged subdata sets characterized by 13 element variables. Even though a couple of sources could not be identified, three to five sources were extracted from each aerosol size-range, and then 9 statistical source profiles were generated. Finally, source contribution of particulate matters on each size-range could be estimated in Suwon area.

  • PDF

The Application of Dump Combustor for Evaluation of DPF(Diesel Particulate Filter) System (DPF 성능 평가를 위한 Dump Combustor의 활용)

  • Nam, Youn-Woo;Lee, Won-Nam;Oh, Kwang-Chul;Lee, Chun-Beom
    • 한국연소학회:학술대회논문집
    • /
    • 2007.05a
    • /
    • pp.98-103
    • /
    • 2007
  • The number of vehicles employing diesel engines is rapidly rising. Accompanying this trend, application of an after-treatment system is strictly required as a result of reinforced exhaust regulations. The Diesel Particulate Filter (DPF) system is considered as the most efficient method to reduce particulate matter (PM), but the improvement of a regeneration performance at any engine operation point presents a considerable challenge by itself. Temperature, gas compostion and flow rate of exhaust gas are important parameters in DPF evaluation, especially regeneration process. Engine dynamometer and degment tester are generally used in DPF evaluation so far. But these test method couldn't reveal the effect of various parameters on real DPF, such as O2 concentration, amount of soot and exhaust gas temperature. This research has studied the possibility using dump combustor that used to take an approach lean premixed combustion in gas turbine for a DPF power and optimized. It is possible that utilize the system as DOC (Diesel Oxidation Catalyst) and SCR(Selective Catalytic Reduction) assessments test as well as DPF evaluation

  • PDF

Computational Simulation by One-Dimensional Regeneration Model of Wall-Flow Monolith Diesel Particulate Filter Trap (벽-유동(Wall-Flow) 모노리스(Monolith) 디젤 입자상물질 필터 트랩의 재생모델에 의한 수치 시뮬레이션)

  • Kim, G.H.;Park, J.K.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.6
    • /
    • pp.41-54
    • /
    • 1995
  • A mathematical model for wall-flow monolith ceramic diesel particulate filter was developed in order to describe the processes which take place in the filter during regeneration. The major output of the model comprises ceramic wall temperature and regeneration time(soot reduction). Various numerical tests were performed to demonstrate how the gas oxygen concentration, flow rate and the initial particulate trap loading affect the regeneration time and peak trap temperature. The model is shown to b in reasonable agreement with the published experimental results. This model can be applied to predict the thermal shock failure due to high temperature during combustion regeneration process.

  • PDF

A Study on the Performance and Particulate Emission Characteristics for the Hydrogen-Premixed Diesel Engine (수소 혼소 디젤 기관의 성능 및 미립자상 물질의 배출 특성에 관한 연구)

  • 채재우;한동성;이상만;전영남;정영식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.2
    • /
    • pp.34-41
    • /
    • 1993
  • In order to reduce harmful substances such as particulates and nitric oxides emitted from diesel engine, man kinds of methodology like high pressure spray of diesel fuel oil, exhaust gas recirculation, emulsified fuel usage and dual fuelling have been studied. Dual fuelling of a diesel engine with hydrogen which is well-known as the clean fuel and has excellent combustibility is expected to be effective in reducing harmful substances from diesel engine. This experimental study was conducted to investigate the effect of premixed hydrogen with intake air on the performance and particulate emission characteristics using a single cylinder, prechamber type diesel engine. As a result, it was clarified that a hydrogen-premixed diesel engine can be operated in the state of lower particulate emission and slightly aggravated fuel economy, compared with the conventional diesel engine.

  • PDF

Experimental Investigation of Nano-sized Particulate Matter Emission Characteristics under Engine Operating Conditions from Common Rail Diesel Engine (커먼레일 디젤엔진의 운전조건이 나노크기 입자상 물질 배출특성에 미치는 영향에 관한 실험적 연구)

  • Lee, Hyung-Min;Myung, Cha-Lee;Park, Sim-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.508-514
    • /
    • 2010
  • The objective of this work presented here was experimental study of steadystate and cold start exhaust nano-sized particle characteristics from common rail diesel engine. The effect of the diesel oxidation catalyst (DOC) on the particle number reduction was insignificant, however, particle number concentration levels were reduced by 3 orders of magnitude into the downstream of diesel particulate filter (DPF). In high speed and load conditions, natural regeneration of trapped particle occurred inside DPF and it was referable to increase particle number concentration. As fuel injection timing was shifted BTDC $6^{\circ}CA$ to ATDC $4^{\circ}CA$, particle number concentration level was slightly reduced, however particle number and size was increased at ATDC $9^{\circ}CA$. Nucleation type particle reduced and accumulation type particle was increased on EGR condition.

A Study on the Size Distribution and Chemical Component of Suspended Particulate during the Period of Sandy Dust Phenomena (黃砂現象時 粉塵의 粒度分布와 化學組成에 關한 硏究)

  • Lee, Min-Hee;Han, Eui-Jung;Shin, Chan-Ki;Han, Jin-Suk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.4 no.2
    • /
    • pp.57-66
    • /
    • 1988
  • Sandy dust phenomena was observed from April 19 to 23, 1988 in Seoul and suspended particulate was collected by Andersen air sampler during this period. The samples were analyzed for 16 components $(SO_n^{2-}, NO_3^-, Cl^-, PO_4^{3-}, NH_4^+, F^-, Al, Fe, K, Cu, Mn, Na, Pb, Mg, Ca, Cd)$. The conclusions are as follwes: 1. Total suspended particulate concentation during the period of sandy dust phenomena was 489 $\mug/m^3$ (ordinary times: 140-125 $mug/m^3$) 2. The water - soluble ion component concentration of suspended particulate during the period of sandy dust phenomena was few and the metal concentration of that was more than that of ordinary times. 3. The cumulative frequency distribution of suspended particulates in logarithmic diagram did not show similar to normal log distribution during the period of sandy dust phenomena. 4. $SO_4^{2-}, NO_3^-, Cl^-, and PO_4^{3-}$ was onsided to coarse particle, and $NH_4^+$ and F to fine particle in the size distribution of water - soluble ion components during the period of sandy dust phenomena. 5. Metal concentration was high and Al, Fe, Cu, Mn, Na, Mg, and Ca was onsided to coarse particle, and K, Pb, and Cd to fine particle in the size distribution of metal components. 6. During the period of sandy dust phenomena the quantity of respirable particle (< 1 $\mum$) was about 3 times and that of metal components were about 2 - 11 times than that of ordinary times. 7. The concentrations of $NO_3^-, Cl^-, NH_4^+$ at ordinary times were 1.1 - 4 time than that of the period of sandy dust phenomena.

  • PDF