• Title/Summary/Keyword: Particulate Concentration

Search Result 945, Processing Time 0.022 seconds

Relationship between Office Residents' Activities and Concentration Distribution of Particulate Contaminants Distribution by Operation of Air Cleaner (공기정화기 가동에 따른 사무실 재실자들의 행동성과 입자상 오염물질의 농도 분포 관계에 관한 연구)

  • Kim, Ki-Youn;Park, Jae-Beom;Kim, Chi-Nyon;Lee, Kyung-Jong
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.4
    • /
    • pp.250-254
    • /
    • 2007
  • The reduction efficiency of air cleaner on particulate contaminants such as dust, airborne bacteria and fungi distributed in the office was relatively higher in case of office with workers than office without workers. This result would be attributed to workers' activities and physical characteristics of particulate contaminants. The air cleaner decreased a concentration of airborne bacteria more than airborne fungi, which implicates that difference of dust adsorption between airborne bacteria and fungi would affect an operation efficiency of air cleaner.

A Study on the Formation of Nitrate in the Atmosphere (환경 대기중 Nitrate의 생성에 관한 연구)

  • 천만영;강공언;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.1
    • /
    • pp.68-73
    • /
    • 1992
  • A study on the formation of particulate nitrate$(NO_3^-)$ and gaseous nitrate$(HNO_3)$ in the atmosphere was carried out in Seoul from Oct 8 to 11 1991. To collect $NO_3^-$ and $HNO_3$ in the ambient air, dual filter pack sampler (47mm$\phi$) was used. In the dual filter pack sampler, the first filter was Teflon filter (poresize 1$\mum$) for collection of $NO_3^-$ and the second filter was Nylon filter (poresize 0.45 $\mum$) for $HNO_3$. Particulate nitrate$(NO_3^-)$ and Sulfate ions were analysed by Ion chromatography. $HNO_3$ concentration was higher in the day time $(9.93\mug/m^3)$ than the night time$(3.50\mug/m^3)$, and Particulate nitrate$(NO_3^-)$ concentration was higher in the night time and early morning$(6.21\mug/m^3)$ than the day time$(4.31\mug/m^3)$. The conversion rate of $NO_x$ to total nitrate$(NO_3^-, HNO_3)$ was 7.57%/hr in the day time and 4.79%/hr in the night time, and total average conversion rate was 5.60%/hr.

  • PDF

A Statistical Assessment of Particulate Exposure Concentration for the Welders and Grinding workers (입자상 물질 폭로농도의 통계적 평가방법에 관한 고찰 -용접·연삭 작업장의 근로자를 대상으로-)

  • Yoon, Young-No;Yi, Kwan-Hyeong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.154-163
    • /
    • 1991
  • Particulate matter exposure leva1 of welders and grinding workers was evaluated in Banwol and Changwon industry complexes. Full period single sample and full period consecutive samples were collected with personal air samplers attached to workers. Compliance difference with 8-hour time weighted average (TWA) was compared by Korean strategy and the classification system recommended by OHSA for employee exposure to particulates. And difference of compliance was compared according to precision of measurement and analysis (total precision). Compliance rate was depended on the total precision, therefore, quality control of measurement and analysis was important.

  • PDF

Preparation of Poly(lactic acid) Scaffolds by the Particulate Leaching (염 추출법에 의한 폴리락틱산 다공성 지지체 가공)

  • Lee, Ji-Hae;Lee, Jong-Rok;Kang, Ho-Jong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.324-331
    • /
    • 2003
  • Particulate leaching method for the preparation of porous PLLA scaffolds was carried out and especially, the effect of PLLA/$CHCl_3$ solution concentration on the salt leaching rate and the pore structure of PLLA scaffolds were considered. It was found that maintaining lower PLLA/$CHCl_3$ concentration and higher $CHCl_3$ evaporation temperature in the preparation of PLLA/NaCl mixtures resulted in the enhancement of salt leaching rat e and higher porosity. This is understood that those conditions could minimize the formation of dense PLLA layer on the surface of PLLA/NaCl mixture as well as introducing better porosity on the surface. Higher salt leaching temperature accelerated the salt leaching rate but it seems that there is no influence on the porosity of PLLA scaffolds.

Performance Evaluation of Window Ventilation System for Reducing Indoor particulate matter (실내 미세먼지 저감을 위한 창호형 환기시스템 성능평가)

  • Yang, Young Kwon;Park, Jin Chul
    • Land and Housing Review
    • /
    • v.10 no.3
    • /
    • pp.1-7
    • /
    • 2019
  • Indoor particulate matter(PM) is a carcinogen and needs to be removed and managed. It is generally reduced and removed through ventilation and filtration. Owing to the recent occurrence of high-concentration fine dust and yellow dust in the atmosphere, however, it is difficult to expect the purification of indoor air through the simple introduction of the outside air. For residential buildings, in particular, they are highly dependent on natural ventilation but the lack of natural ventilation is worsening because concerns over the inflow of external pollutants are increasing. Therefore, this study designed and manufactured a window ventilation system that does not require a duct to improve the maintenance and management problems of general ventilation system, and constructed indoor PM concentration change data through performance evaluation.

A Study on the Emission and Dispersion of Particulate Matter from a Cement Plant (한 시멘트공장의 분진발생과 대기확산에 관한 조사연구)

  • Chang, Man-Ik;Chung, Yong;Kwon, Sook-Pyo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.16 no.1
    • /
    • pp.67-77
    • /
    • 1983
  • To investigate the an air pollution by particulate matter and its dispersion, a cement plant produceing portland cement 600,000 ton/year and its vicinity were surveyed from Obtober, 1980 to April, 1983. The survey was mainly focused on main stack emmission rate of the cement plant and particle size distribution in the dust, dustfall and total suspended particulate concentration in the area by month and distance from the stack. The results of the study were as follows; 1. The main stack emission rate was surveyed before and after the spray tower was additionally installed to the original E.P bag filter. Before the spray tower installed, the main stack emission rate was higher ($0.64g/Nm^3$) than the emission standard of Korean Environmental Preservation Law's ($0.59g/Nm^3$, amended to $0.4g/Nm^3$ on April 1983), but after the spray tower was installed, its main stack emission rate was markedly decreased to the standard ($0.43g/Nm^3$). 2. $2{\sim}3{\mu}m$ of the particle size was the largest portion (20.8%) of the dust particulate from the main stack and 50% of the frequency distribution was $1.5{\mu}m$ of the size. Most particle size was below $10{\mu}m$. 3. The spray tower reduced the dustfall to $37.81{\sim}9.76\;ton/km^2/month$ while dustfall appeared at $45.29-15.45ton/km^2/month$, in the vicinity of plant before spray tower installed 4. Mean concentrations of total suspended particulate for 24 hours of the various stations were determined in $20.6-200.0{\mu}g/m^3$, 3 stations of tham were higher than the value of Harry and William's arthmetic average standard $130{\mu}g/m^3$. 5. Linear regression between dustfall [X] and total suspended particulate[Y] concentration was an equation, Y=4.024X+11.479.[r=0.91] 6. During the whole seasons in the opposite area 100m apart from the omission source the prevailing wind direction was with estimated more than $30ton/km^2/month$, and the concentration of total suspended particulate for 24 hours averaging time was more than $140{\mu}g/m^3$ in the same area and direction. 7. Assuming the wind direction were constant through the day dustfalls for a day were estimated at $13.40ton/km^2/day,\;10.79ton/km^2/day$ and $4.55ton/km^2/day$ at various distances of 100m, 500m and 1,500m from the emission source respectively. 8. In the simutalion of dustfall and suspended dust by area, Gaussian dispersion model modified by size distribution of particulate matter was not applicated since the emission of dust were from multi sources other them stack. From the above results, it could be applied that the dispersion of dust from the cement plant is estimated and regulated for the purpose of environmental protection.

  • PDF

Measurement of Dry deposition at Seoul, Chunchon and Anmyon-do by Using Filter pack Method (필터팩을 이용한 서울과 춘천, 안면도의 건성 강하량 측정)

  • Kim, Man-Goo;Kang, Mi-Hee;Hong, Young-Min;Park, Ki-Jun;Lee, Bo-Kyung;Lee, Dong-Soo;Kim, San
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.1
    • /
    • pp.19-29
    • /
    • 2001
  • Atmospheric concentrations of acidic pollutant were measured by the 4 stage filter pak method at Chunchon and by the 3 stage filter pack method at Seoul and Anmyon-do from January to December 1998. The sample was collected for 24 hours on every Wednesday. Concentrations of particulate matters were highest at Anmyon-do. The particulate concentration was much higher during the warm season than other seasons. While the particulate concentration was higher during the warm season, the concentration of gaseous matter was higher in winter. Dry deposition flux was calculated by using reported deposition velocities and concentration of pollutants measured in this study. The dry deposition velocities used in this study for SO$_2$, SO$_{4}^{2}$, HNO$_3$,NO$_{3}^{-}$ and NH$_3$ were 0.29, 0.15, 2.08( 2.13 only for Anmyon-do), 0.20 and 1.00cm/sec, respectively. At Chunchon, annual sulfur flux originated from dry deposition was 384 kg/$textrm{km}^2$, and the flux from wet deposition was 782kg/$textrm{km}^2$. Dry deposition of sulfur was 33% of total sulfur deposition. The annual nitrogen flux originated from dry deposition was 1,892kg/$textrm{km}^2$. And the flux from wet deposition was 1,066kg/$textrm{km}^2$. Dry deposition of nitrogen was 64% of total nitrogen deposition. Dry deposition as well as wet deposition have to be considerd in the study on acidification of environment such as soil or watershed.

  • PDF

Changes in Concentration Levels of Polycyclic Aromatic Compounds Associated with Airborne Particulate Matter in Downtown Tokyo after Introducing Government Diesel Vehicle Controls

  • Kojima, Yuki;Inazu, Koji;Hisamatsu, Yoshiharu;Okochi, Hiroshi;Baba, Toshihide;Nagoya, Toshio
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • The effectiveness of the government regulation on tail-pipe emission for diesel vehicles issued in 2003 in Tokyo was evaluated in this study. Variations in annual average concentrations of polycyclic aromatic hydrocarbons (PAHs) and nitro-PAHs associated with airborne particulate matter were investigated in connection with the variation in airborne elemental carbon (EC) concentration in downtown Tokyo, Japan in 2006-2007 and in 1997-1998. The annual average concentrations of EC, seven different PAHs, and 1-nitropyrene were found to have decreased significantly from 1997-1998 to 2006-2007. The most prominent decrease in atmospheric concentration was observed for 1-nitropyrene, which is a representative nitro-PAH originating from diesel vehicles. This indicated that the government control has worked to considerably reduce both atmospheric mutagens and airborne particulate matter. In contrast, the concentrations of two nitro-PAHs, 2-nitrofluoranthene and 2-nitropyrene, remained the same. These nitro-PAHs are known to be formed by atmospheric nitration of their parent PAHs, and this result suggested factors other than the concentration of parent PAHs and $NO_2$ affects the degree of atmospheric formation of nitro-PAHs.

A Study on the Change of Condensable Particulate Matter by the SO2 Concentration among Combustion Gases (연소 배출가스 중 SO2 농도에 따른 응축성먼지 변화에 관한 연구)

  • Yu, JeongHun;Lim, SeulGi;Song, Jihan;Lee, DoYoung;Yu, MyeongSang;Kim, JongHo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.5
    • /
    • pp.651-658
    • /
    • 2018
  • Particulate matter (PM) emitted from fossil fuel-combustion facilities can be classified as either filterable or condensable PM. The U.S. Environmental Protection Agency (EPA) defined condensable PM as material that is in the phase of vapor at the stack temperature of the sampling location which condenses, reacts upon cooling and dilution in the ambient air to form solid or liquid in a few second after the discharge from the stack. Condensable PM passed through the filter media and it is typically ignored. But condensable PM was defined as a component of primary PM. This study investigates the change of condensable PM according to the variation in the sulfur dioxide of combustion gas. Domestic oil boilers were used as the source of emission ($SO_2$) and the level of $SO_2$ concentration (0, 50, 80, and 120 ppm) was adjusted by diluting general light oil and marine gas oil (MGO) that contains sulfur less than 0.5%. Condensable PM was measured as 2.72, 6.10, 8.38, and $13.34mg/m^3$ when $SO_2$ concentration in combustion gas were 0, 50, 80, and 120 ppm respectively. The condensable PM tended to increase as the concentration of $SO_2$ increased. Some of the gaseous air pollutants emitted from the stack should be considered precursors of condensable PM. The gas phase pollutants which converted into condensable PM should reduced for condensable PM control.

A Study on Green Space Location Selection to Reduce Particulate Matter by Projecting Distributions of Emission Source and Vulnerable Groups - focusing on Seongdong-gu, Seoul - (미세먼지 배출원과 취약계층 분포 추정을 통한 미세먼지 저감 녹지 입지 선정 연구 - 서울시 성동구를 대상으로 -)

  • Shin, Ye-Eun;Park, Jin-Sil;Kim, Su-Yeon;Lee, Sang-Woo;An, Kyung-Jin
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.24 no.1
    • /
    • pp.53-68
    • /
    • 2021
  • The study aims to propose a locating method of green space for reducing Particulate Matter (PM) in ambient air in conjunction with its source traces and vulnerable groups. In order to carry out the aims and purposes, a literature review was conducted to derive indicators of vulnerable area to PM. Based on the developed indicators, the vulnerable areas and green spaces creation strategies for each cluster were developed for the case of Seongdong-gu, Seoul. As a result, six indicators for vulnerability analysis were came out including the vulnerable groups (children's facilities, old people's facilities), emission sources (air pollutant emission workplaces, roads), and environmental indicators (particulate matter concentration, NDVI). According to the six selected indicators, the target area was divided into 39 hexagons and analyzed to result the most vulnerable areas to particulate matter. As a result of comprehensive vulnerability analysis, the Seongsu-dong area was found to be the most vulnerable to particulate matter, and 5 clusters were derived through k-means cluster analysis. Cluster 1 was analyzed as areas that most vulnerable to particulate matter as a result of the comprehensive analysis, therefore urgent need to create green spaces to reduce particulate matter. Cluster 2 was areas that mostly belonged to the Han River. Cluster 3 corresponds to the largest number of hexagons, and since many vulnerable groups are distributed, it was analyzed as a cluster that required the creation of a green spaces to reduce particulate matter, focusing on facilities for vulnerable groups. Three hexagons are included in cluster 4, and the cluster has many roads and lacks vegetation in common. Cluster 5 has a lot of green spaces and is generally distributed with fewer vulnerable groups and emission sources; however, it has a high level of particulate matter concentration. In a situation where various green spaces creation projects for reducing particulate are being implemented, it is necessary to consider the vulnerable groups and emission sources and to present green space creation strategies for each space characteristic in order to increase the effectiveness of such projects. Therefore, this study is regarded as meaningful in suggesting a method for selecting a green area for reducing PM.