• Title/Summary/Keyword: Particulate Concentration

Search Result 945, Processing Time 0.024 seconds

Studies on the Detergency of Particulate Soil using Vacuum Cleaner Dirt as Model (진공청소기 분진을 모델로 한 고형오염의 세척성에 관한 연구)

  • Kang In-Sook;Kim Sung-Reon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.13 no.3 s.31
    • /
    • pp.286-294
    • /
    • 1989
  • This Study has treated the effects of fiber, surfactants, temperature, surfactant concentration, pH, electrolyte, fatty acid contents and mechanical force on the removal of particulate soil from fabric, vacuum cleaner dirt was used as model particulate soil. The fabrics were soiled with mixture of vacuum cleaner dirt and fatty soil, and washed in Terg-O-tometer. The detergency was evaluated by measuring reflectance of a fabric before and after washing. The results were as follows. 1. The fiber type showed a different pattern of soil removal with surfactants. In general, particulate soil removal increased in the following order Acetate>PET. Nylon>Cotton. Particulate soil removal, which is affected by the surfactant type, increased in the following order NPE $(EO)_{10}\leqq$Soap>SLS>DBS>Tween 80. 2. The influence of temperature on the particulate soil removal was very complex because efficiency of removal was varied with surfactant and fiber types. The washing efficiency of NPE $(EO)_{10}$ was highest at around $40^{\circ}C\;and\;60^{\circ}C$ with cotton and PET but the washing efficiency of DBS was the highest at $60^{\circ}C$ with cotton, decreased monotonously with increasing temperature with PET 3. The detergency of particulate soil increased with increasing surfactant concentration at relatively low concentration and then levelled off above some optimum concentration. 4. The removal of particulate soil increased with increasing pH and mechanical force. 5. Effect of electrolyte on the particulate soil removal was depended on the concentration of the surfactant. At low concentration of surfactant, addition of electrolytes improved soil removal but above the some concentration no effect was observed. At high concentration of surfactant, Vie., $0.6\%$ , the maximum washing effect is reached without added electrolyte. These result indicate that added electrolyte only influence the adsorption of surfactant on the soil and fiber 6. Fatty acid content in the soil did not influence on particulate soil removal without regard to surfactants.

  • PDF

Formation of particulate-phase and gas-phase polycyclic aromatic hydrocarbons in cigarette smoke

  • Shimazu, Haruki;Yata, Tsuyoshi;Ozaki, Naoto
    • Advances in environmental research
    • /
    • v.6 no.3
    • /
    • pp.189-202
    • /
    • 2017
  • This study examines the concentrations of particulate-phase polycyclic aromatic hydrocarbons (PAHs) and gas-phase PAHs in sidestream cigarette smoke. Sixteen PAHs were determined for four brands of cigarettes. The volume of the experimental room is approximately $66m^3$. The air samples in the room were collected before and after smoking. The median total of particulate-phase and gas-phase PAH concentrations before smoking $3.13ng/m^3$and $48.0ng/m^3$, respectively. The median concentrations of them after smoking were $10.0ng/m^3$ and $79.6ng/m^3$. The median increases in the total of 16 PAH concentrations per cigarette during smoking were 271 ng for the particulate-phase PAHs and 1960 ng for the gas-phase PAHs. According to the relationship between particulate-phase and gas-phase PAHs after smoking, the two- to four-ring gas-phase PAHs and the higher molecular weight particulate-phase PAHs were probably formed from similar precursors. The relationship between the total suspended particulate (TSP) concentration and the increase in the total particulate-phase concentration of the 16 PAHs per cigarette during smoking were significantly positive. The increase in the total gas-phase concentration of the 16 PAHs tended to increase as the TSP concentration increased. This may indicates that decreasing the amount of TSP produced inhibit the production of PAHs during smoking.

Characteristics of Particulate Matter Generated during the Operation of a Small Directly Fired Coffee Roaster (소형 직화식 커피 로스터 이용 시 발생하는 미세먼지 특성 연구)

  • Yu, Da Eun;Kim, Seung Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.236-248
    • /
    • 2020
  • Objectives: The purpose of this study was to evaluate the concentrations of particulate matter generated during coffee roasting and to study various factors affecting the concentrations. Methods: Differences in concentration levels were investigated based on various factors to understand the emission rates of particulate matter over time and to compare the mass and number concentrations according to their size. Sampling was performed in closed laboratories without the operation of air conditioning or ventilation. Optical Particle Sizer(OPS) was used as a measuring device. An OPS measures using a light-scattering method. Sampling was performed for sixty minutes at one-minute intervals. The background concentration was measured for about 30 minutes before starting of coffee roasting. The concentrations of particulate matter generated during coffee roasting were monitored until roasted coffee beans were removed from the roaster and cooled down. Several factors affecting the concentrations of particulate matter were investigated, which includes the origins of green beans, the roasting level, and the input amount of green beans. Results: The results of this study may be summarized as follows: 1) There was no difference in particulate matter concentration levels by the origin of the green beans, but a statistically significant difference in concentration levels by roasting level and the input amount of green beans; The higher the roasting level, the higher was the particulate matter concentration. The more green beans we put in the roaster, the higher were the concentrations; 2) The PM10 mass concentrations increased over time. The average concentration after roasting was higher than the average concentration during roasting; 3) In the distribution of mass and number concentration by particle diameter, the majority of particles was below 2.5 ㎛. Conclusions: Persons who work in roastery cafes can be exposed to high concentrations of particulate matter. Therefore, personal exposure and risk assessment should be conducted for roastery cafe workers.

Characteristics of Nano-Particles Exhausted from Diesel Passenger Vehicle with DPF

  • Park, Yong-Hee;Shin, Dae-Yewn
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.6
    • /
    • pp.533-538
    • /
    • 2006
  • The nano-particles are known to influence the environmental protection and human health. The relationships between transient vehicle operation and nano-particle emissions are not well-known, especially for diesel passenger vehicles with DPF(Diesel Particulate Filter). In this study, two diesel passenger vehicles were measured on a chassis dynamometer test bench. The particulate matter (PM) emission of these vehicles was investigated by number and mass measurement. The mass of the total PM was evaluated using the standard gravimetric measurement method, and the total number concentrations were measured on a ECE15+EUDC driving cycle using Condensation Particle Counter (CPC). According to the investigation results, total number concentration was $1.14{\times}10^{11}$M and mass concentration was 0.71mg/km. About 99% of total number concentration was emitted during the $0{\sim}400s$ because of engine cold condition. In high temperature and high speed duration, the particulate matter was increased but particle concentration was emitted not yet except initial engine cold condition According to DPF performance deterioration, the particulate matter was emitted 2 times and particle concentration was emitted 32 times. Thus DPF performance deterioration affects particle concentration more than PM.

Detergency of Particulate Soil of PET Fabric Finished with Hydrophilic and Hydrophobic Chemicals (친수 및 소수처리 PET직물의 고형오구의 세척성)

  • Kang, In-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.11
    • /
    • pp.1237-1245
    • /
    • 2012
  • The effect of hydrophilicity and hydrophobicity of PET fabric on the detergency of particulate soil were investigated as functions of the concentration of hydrophilic and hydrophobic chemicals, surfactant concentration, ionic strength, adhesion and removal time, and pH. The detergency of the particulate soil was determined by the adhesion of particles to and their removal from fabric, the PET fabric and ${\alpha}-Fe_2O_3$ were used as textile materials and for the model of particulate soil, respectively. The hydrophilic and hydrophobic finish for PET fabric was treated with a polyester, silicone and fluorine organic compound of resin respectively. The adhesion of particulate soil to fabric treated with hydrophobic chemicals were slightly higher but its removal from fabric treated with hydrophobic chemicals was largely higher than fabric treated with a hydrophilic chemical regardless of solution conditions such as the concentration of hydrophilic and hydrophobic chemicals, surfactant concentration, ionic strength, adhesion and removal time, and pH. Therefore, hydrophobic treatment for fabric had a more positive effect than the hydrophilic treatment on the detergency of particulate soil.

Environmental Planning Contermeasures Considering Spatial Distribution and Potential Factors of Particulate Matters Concentration (미세먼지 농도의 공간적 현황 및 잠재영향인자를 고려한 환경계획적 대응 방향)

  • Sung, Sun-Yong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.23 no.1
    • /
    • pp.89-96
    • /
    • 2020
  • Adverse impact of Particulate Matters(PM10, PM2.5; PMs) significantly affects daily lives. Major countermeasures for reducing concentration of PMs were focused on emission source without considering spatial difference of PMs concentration. Thus, this study analyzed spatial·temporal distribution of PMs with observation data as well as potential contributing factors on PMs concentration. The annual average concentration of PMs have been decreased while the particulate matter warnings and alerts were significantly increased in 2018. The average concentration of PMs in spring and winter was higher than the other seasons. Also, the spatial distribution of PMs were also showed seasonality while concentration of PMs were higher in Seoul-metropolitan areas in all seasons. Climate variables, emission source, spatial structure and potential PM sinks were selected major factors which could affects on ambient concentrations of PMs. This paper suggest that countermeasures for mitigating PM concentration should consider characteristics of area. Climatic variables(temperature, pressure, wind speed etc.) affects concentrations of PMs. The effects of spatial structure of cities(terrain, ventilation corridor) and biological sinks(green infrastructure, urban forests) on concentration of PMs should be analyzed in further studies. Also, seasonality of PMs concentration should be considered for establishing effective countermeasures to reduce ambient PMs concentration.

Distribution and Behaviors of In-Situ Suspended Particulate Matters of Gwangyang Bay (광양만내의 현장 부유입자물질 분포와 거동)

  • Lee, Byoung-Kwan;Kim, Seok-Yun;Cho, Hyun-Man
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.99-105
    • /
    • 2010
  • The concentration and size analysis of in-situ suspended particulate material were measured using an optical instrument, LISST-100, in the bottom layer at the three inlets of the Seomjin River Estuary, mouth of Gwangyang bay, and Gwangyang bay-side of the Namhae Bridge. In the Seomjin river estuary and mouth of Gwangyang bay-side of the Namhae Bridge, the in-situ mean grain size of the suspended material changed from a uni-modal distribution with a dominant peak at a coarse fraction to a bi-modal distribution with a secondary peak at the finer particles. Seomjin River. The interactions between suspended particulate concentration and beam attenuation coefficient of suspended particulate matters depended on the supply of finer and coarser particles in the mouth of Gwangyang Bay and Seomjin River. So, interactions reflected difference of the concentration, mean size and sorting of suspended particulate matters. The difference of interaction showed dynamic behaviors to the resuspension and deflocculation processes increased river discharge. This showed that it may be possible to use the interactions between the suspended particle concentration and beam attenuation coefficient to monitor the temporal and spatial distributions of in-situ particles.

Effects of Regeneration Parameters on Oxidation of Particulate in a Diesel Particulate Trap System (디젤 입자상물질 후처리 장치에서 입자상물질의 연소에 미치는 재생 인자의 영향)

  • Kim, J. U.;Cho, H.;Kim, H. U.;Park, D. S.;You, C.;Kim, E. S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.2
    • /
    • pp.168-177
    • /
    • 1998
  • The effects of the regeneration parameters such as inlet gas temperature, space velocity, oxygen concentration of the exhaust gas, and initial particulate loading on the oxidation of the particulate inside ceramic cordierite filter have been investigated through an engine experiment. As the inlet gas temperature increases, the remarkable filter temperature occurs owing to the rapid combustion rate. Though the higher space velocity affirms the safe regeneration, it also requires much fuel consumption of the burner. For that reason, the space velocity should be compromised considering the fuel economy. The excessive accumulation of the particulate may cause undesirable regeneration temperatures inside filer even under the optimized regeneration condition. The inlet gas temperature should be selected to overcome the variation of the oxygen concentration which is inherent feature of the diesel engine. It is the most important factor in the regeneration control techniques.

  • PDF

The Concentration of TSP and Heavy Metals in the Indoor Air of Local PC Rooms (지방 일개도시 PC방에서의 실내공기중 TSP농도와 TSP내 중금속 농도)

  • Cha Hyun Su
    • Journal of Korean Public Health Nursing
    • /
    • v.16 no.1
    • /
    • pp.190-200
    • /
    • 2002
  • This study was carried out to investigate and analyze TSP of the PC rooms. The concentration of the total suspended particulate and heavy metals contained in the total suspended particulate of the 15 PC rooms located in one local city were measured. The statistical correlation coefficients between the total suspended particulate and factors of the indoor condition (number of fan or size of pc room, illumination), between the heavy metals and factors of the indoor condition were studied. The results are as follows: 1. The factors of the indoor condition of the 15 PC rooms are as follows. Average illumination was 24 luxes. Average number of computers installed were 37. Average number of the fans was 7. and the size of investigated PC rooms was $139.94m^2$. 2. The mean age of the subjects was 21.8 years old. they $(51.5\%)$ used the 15 pc rooms for fewer than 2 hours per one day. 3. The mean concentration of total suspended particulate (TSP) is lower in the evening ${139.085\;(2.462)\;{\mu}g/m^3}$ than the night ${166.216(2.609){\mu}g/m^3}$. 4. The mean concentration of total suspended particulate was industrial work area) residential area) commercial area. 5. The distribution of heavy metals were indicated as Zn>Cr>Pb>Cd in the indoor air at PC rooms. and the concentration rate of Zn was the highest among heavy metals. but this increase didn't show any relationship with many factors of indoor condition (number of fan or size of pc room, lighting) 6. The concentration of TSP & heavy metals didn't have any relationship between the factors of indoor environment (number of fans, size of pc room, lighting).

  • PDF

Effects of Mixed Characteristics of Oily Soil on Detergency of PET Fabric in Oily/Particulate Soil Mixed System (지용성/고형오구의 혼합오염계에서 지용성오구의 혼합특성에 따른 PET직물의 세척성)

  • Kang, In-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.10
    • /
    • pp.1242-1251
    • /
    • 2011
  • This study investigates the effect of mixed characteristics of oily soil such as mixed ratio, polarity of oily soil on contact angle of fabric, removal of oily and particulate soil from PET fabric in oily/particulate soil mixed system. The contact angle of fabric in the surfactant solution with suspended oily soil was examined as a fundamental environment of detergency of soil from fabrics. Detergency was investigated as function of mixed ratios of oily/ particulate soil, type of oily soil, surfactants concentration, surfactant type and temperature of detergency in surfactant solution. The contact angle of fabric in surfactant solution sharply increased with mixing nonpolar oily soil; in addition, the contact angle slightly increased with increasing contents of oily soil and decreased with increasing surfactant concentration. The removal of oily and particulate soil from fabric was higher in the solution mixed with polar versus nonpolar oily soil. The detergency increased with increasing surfactant concentration and the increased temperature of surfactants solution that were relatively improved in NPE compared to DBS solutions, The results indicated that the detergency of oily and particulate soil showed a similar trend in oily/ particulate mixed soil systems. The general contact angle of fabric was well related with the detergency of oily and particulate soil in oily/particulate mixed soil system, therefore, the primary factor determining the detergency of soil in oily/particulate mixed soil system may be the contact angle of fabric caused by wettability.