• Title/Summary/Keyword: Particle-induced X-ray emission analysis

Search Result 15, Processing Time 0.022 seconds

Estimation of Source Apportionment of Ambient PM2.5 at Western Coastal IMPROVE Site in USA (미국 서부 해안 IMPROVE 측정소에 대한 대기 중 PM2.5의 오염원 기여도 추정)

  • Hwang, In-Jo;Kim, Dong-Sool;Hopke, Philip K.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.1
    • /
    • pp.30-42
    • /
    • 2008
  • In this study, the chemical compositions of $PM_{2.5}$ samples collected at the Redwood National Park IMPROVE site in California from March 1988 to May 2004 were analyzed to provide source identification and apportionment. A total of 1,640 samples were collected and 33 chemical species were analyzed by particle induced X-ray emission, proton elastic scattering analysis, photon induced X-ray fluorescence, ion chromatography, and thermal optical reflectance methods. Positive matrix factorization (PMF) was used to develop source profiles and to estimate their mass contributions. The PMF modeling identified five sources and the average mass was apportioned to motor vehicle (35.8%, $1.58\;{\mu}g/m^3$), aged sea salt (23.2%, $1.02\;{\mu}g/m^3$), fresh sea salt (21.4%, $0.94\;{\mu}g/m^3$), wood/field burning (16.1%, $0.71\;{\mu}g/m^3$), and airborne soil (3.5%, $0.15\;{\mu}g/m^3$), respectively. To analyze local source impacts from various wind directions, the CPF and NPR analyses were performed using source contribution results with the wind direction values measured at the site. These results suggested that sources of $PM_{2.5}$ are also sources of visibility degradation and then source apportionment studies derived for $PM_{2.5}$ are also used for understanding visibility problem.

Development of Polymeric Water Absorbent Film(PWAF) for the Collection of Size-classified Fog Droplets

  • Ma, Chang-Jin;Mikilo-kasahara;Park, Kum-Chan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E1
    • /
    • pp.17-24
    • /
    • 2001
  • For the purpose of collecting fog droplets as a function of size a new sampling method was developed in this study. Formation of 100$\pm$10㎛ thickness of polymeric water absorbent film (PWAF) on a nuclepore filter could be successfully realized. Also applicability of particle induced X-ray emission (PIXE) method to the chemical analysis of size-segregated fog droplets collected on PWAF was examined experimentally with synthetic fog droplets generated from a nebulizer. Absorption capacity of S-PAAS polymeric water absorbent shows marked decreases in the range less than 1 wt% and slight decrease between 1 and 3.5 wt% of every salt concentration. Dependency of absorption capacity on pH shows the maximum at pH 7. No apparent peak which can influence the quantitative analysis of elements dissolved and suspended in fog droplets was found at PIXE spectrum of PWAF blank. PWAF kept the original shape without rupture under the PIXE analytical conditions of beam intensity for 10 to 60 nA and irradiation time of 4∼5 min. It should be said that the proposed new technique in the work is helpful to get more detailed information of fog droplets, to clarify the fog formation processes, and to develop a model of acid deposition process.

Quality Control on Neutron Activation Analysis for Urban Dust by the Proficiency Test (비교숙련도 시험을 통한 도시대기분진에 대한 중성자방사화분석법의 품질관리)

  • Moon, Jong-Hwa;Kim, Sun-Ha;Chung, Yong-Sam
    • Analytical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.433-438
    • /
    • 2002
  • Trace elements in two air filters (V-50, P-50) artificially loaded with urban dust provided from IAEA were determined non-destructively using instrumental neutron activation analysis. Standard reference material (Urban Particulate Matter, SRM 1648) of National Institute of Standard and Technology was used for analytical quality control. About 20 elements in both of loaded filter samples were determined. To evaluate inter-laboratory comparison and proficiency test, analytical data were statistically treated with the results which collected from 49 laboratories, 40 countries participated in this study using neutron activation analysis, particle induced X-ray emission, inductively coupled plasma mass spectroscopy, etc,. From the results of statistical treatment, Z-scores are within ${\pm}2$. Furthermore, accuracy and precision of obtained analytical values are passed according to the criteria of the proficiency test. Consequently, it was proved that analytical quality for air dust samples being performed has been controlled properly.

PIXE Analysis for Elemental Analysis in Aerosol (PIXE 분석법을 이용한 대기분진 중 함유원소 분석)

  • Kim, Duk-Kyung;Choi, Han-Woo;Woo, Hyung-Joo;Kim, Young-Suk;Hong, Wan;Kim, Nak-Bae;Lee, Jin-Hong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.2
    • /
    • pp.90-97
    • /
    • 1994
  • PIXE( Proton Induced X- ray Emission ) analysis has been applied to the analysis of aerosol for the Purpose of pollution monitoring. Coarse and fine Particle fractions were sampled selectively, using Nuclepore filter in stacked filter units, once a month from February to September in 1993 at urban and rural sites. Concentration of 9 elements, Si, S, K, Ca, Mn, Fe, Cu, Zn and Pb was determined without Pretreatment of Samples. Comparison of data between urban and rural site revealed higher elemental concentration level in urban aerosol. From April to May aerosol sampling was carried out daily to observe the effect of Yellow Sand on the composition of aerosol in the Korean Peninsula. During the Yellow Sand period, Si, Ca, Fe content level in aerosol became more than 5 times higher than normal. The elemental concentration of the aerosol samples of Daejeon City was compared with that of two foreign cities. S and Pb( which are fuel- derived elements) levels in Daejeon City aerosol appeared to be lower than those of foreign cities. And it may be due to the leaded-fuel restriction policy of Korean government since 1987.

  • PDF

Characterization of Wintertime Atmospheric Aerosols in Seoul Using PIXE and Supplementary Analyzers

  • Ma, Chang-Jin;Mikio Kasahara;Hwang, Kyung-Chul;Yeo, Hyun-Gu;Park, Kum-Chan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.E
    • /
    • pp.19-27
    • /
    • 2000
  • Particle Induced X-ray Emission (PIXE) and Elemental Analysis Syztem (EAS) were applied to the investiga-tion of the Characteristics and sources of wintertime atmospheric aerosols in Seoul. Atmospheric aerosols were collected by both fine and coarse fractions using a two-stage filter pack sampler from Kon-Kuk university during the winter season of 1999. PIXE was applied to the analysis of the middle and heavy elements with atomic numbers greater than 14(Si) and EAS was applied to the measurement of the light elements such as H, C and N. The fact that 64.2% of mass of fine particles in Seoul consists of the light elements (N, C , and H) suggests that the measurement of light elements is extremely important. The average mass concentration is Seoul was 38.6$\mu\textrm{g}$m(sup)-3. Elements such as Ca, Fe, Mg, and Ti appeared to have very low Fine/Coarse ratios(0.1∼0.4), whereas che-mical components related to anthropogenic sources such as Br, V, Pb, and Zn were observed to accumulate in the fine fraction. In the Asian Dust Storm(ADS) event, the concentation of soil components increased dramatically. Reconstruction of the fine mass concentrations estimated by a newly revised simple model was fairly in good agreement with the measured ones. Source identification was attempted using the enrichment factor and Pearsons coefficient of correlation. The typical elements derived from each source could be classified by this method.

  • PDF