International Journal of Aeronautical and Space Sciences
/
v.17
no.2
/
pp.139-148
/
2016
The passive control methods such as horizontal and vertical fences on the lower surface of the bluff body were applied to suppress the vortex shedding and enhance the aerodynamic stability of flow. For investigating the effects of the passive control methods, wind tunnel experiments on the unsteady flow field around a bluff body near a moving ground were performed. The boundary layer and velocity profiles were measured by the Hot Wire Anemometer (HWA) system and the vortex shedding patterns and flow structures in a wake region were visualized via the Particle Image Velocimetry (PIV) system. Also, it is a measuring on moving ground condition that the experimental values of the critical gap distances, Strouhal numbers and aerodynamic force FFT analyses. Through the experiments, we found that the momentum supply due to moving ground caused the vortex shedding at the lower critical gap distance rather than that of fixed ground. The horizontal and vertical fences increase the critical gap distance and it can suppress the vortex shedding. Consequently, the stability characteristics of the bluff body near a moving ground could be effectively enhanced by the simple passive control such as the vertical fences.
International Journal of Aeronautical and Space Sciences
/
v.9
no.1
/
pp.111-120
/
2008
A particle image velocimetry (PIV) technique was employed to investigate the effects of blowing jet on the flow characteristics over stationary and pitch-oscillating airfoils. The Reynolds number was $7.84{\times}10^5$ based on the chord length. It was found that for stationary airfoil cases, continuous and pulsating blowing jets successfully reduced separated wake region at high angles of attack. A comparison study of two different types of jet blowing indicated that pulsating jet is more effective than continuous jet for flow separation control. Pulsating leading-edge blowing postpones flow separation and increased stall angle of attack by $2^{\circ}{\sim}3^{\circ}$. For pitch-oscillating airfoil cases, the PIV results showed that blowing jet efficiently delays the separation onset point during pitch-up stroke, whereas it does not prevent flow separation during pitch-down stroke, even at angles of attack smaller than static ones.
Journal of the Society of Naval Architects of Korea
/
v.49
no.5
/
pp.410-415
/
2012
An experimental study is carried out to investigate the near-wake characteristics of a NACA 0018 foil with a flat plate. Two-frame grey-level cross correlation PIV method is used to measure the local flow characteristic around a pitch damping foil to control the vertical motion of high speed crafts in a circulating water channel. The analysis also includes angles of attack 10 and 20 degrees respectively. Reynolds number $Re{\fallingdotseq}3.5{\times}10^4$ based on the chord length(C=100mm) of NACA0018 has been applied during the whole experiments. The distance between the foil and the flat plate is D/C=0.5, 1.0 and 1.5 respectively. The channel effect according as the distance between the foil and the flat plate has a close relation with the velocity distributions around the foil. In the wake of 20-degree of attack, the complex turbulent flow and a thick boundary layer are formed due to the processes of vortex generation and dissipation.
Journal of the Society of Naval Architects of Korea
/
v.44
no.3
s.153
/
pp.219-227
/
2007
A stereo-PIV (particle image velocimetry) technique is used to investigate the vortical structure of the wake behind a rotating propeller in the present study. A four bladed propeller is tested in a cavitaion tunnel without any wake screen. Hundreds of instantaneous velocity fields are phase-averaged to reveal the three dimensional spatial evolution of the flow behind the propeller. The results of conventional 2-D PIV are also compared with those of the stereo-PIV to understand the vortical structure of propeller wake deeply. The variations of radial and axial velocities in the 2-D PIV results seem to be affected by the out-of-plane motion. generating a little perspective error in the in-plane velocity components of the slipstream. The strong out-of-plane motion around the hub vortex also causes the perspective error to vary the axial velocity component a little at the near wake region. The out-of-plane velocity component had the maximum value of about 0.3U0 in the tip vortices and continued its magnitude in the wake region.
Journal of the Society of Naval Architects of Korea
/
v.44
no.6
/
pp.579-589
/
2007
Contrary to the conventional single-point measuring devices such as LDV, pitot-tube, hot-wire, etc., it would be possible to measure instantaneously 3-D flow fields with a stereoscopic PIV system. In this paper, we present an analysis algorithm for a stereoscopic PIV system using the normalized cross-correlation (NCC) and a 3-D calibration based reconstruction method. The evaluation method based on NCC is one of the most accurate correlation-based methods. We validated the developed algorithm through a benchmarking comparison with 3-D artificial SPIV images and calibration target images.
Proceedings of the Korean Nuclear Society Conference
/
1998.05a
/
pp.590-595
/
1998
차세대 원자로(KNGR : Korea Next Generation Reactor)에는 새로운 안전개념으로서 피동형 안전주입탱크(Safety Injection Tank. SIT)의 도입을 고려하고 있는데, 이러한 피동형 유량조절기능은 안전주입탱크내의 유체기구(Fluidic device)인 볼텍스챔버(vortex chamber)에 의해 이루어진다. 볼텍스챔버는 내부에서 발생되는 와류강도에 따라 유동저항의 강도가 달라짐을 이용하여 유량을 피동적으로 조절할 수 있는 유체기구이다. 본 연구에서는 볼텍스챔버의 유동특성을 관찰하기 위하여 소규모 실험장치를 구축하고, 이를 이용하여 실험을 수행하였다. 본 연구는 두 단계로 수행되었다. 제1단계 실험에서는 볼텍스챔버의 기하학적 특성이 안전주입탱크의 안전주입수 방출특성에 미치는 영향에 대한 거시적 관점에서의 연구로서. 볼텍스챔버의 기하학적 변수(유입구 및 방출구의 직경)가 안전주입수의 방출과정에서 발생되는 SIT 내의수위 거동, 안전주입수의 방출유량 특성등에 미치는 영향에 대해 중점적으로 고찰하였다 제2단계 실험에서는 1단계 실험에서 관찰된 안전주입탱크의 여러 가지 방출특성과 볼텍스챔버 내부 유동장의 유동특성과의 관련성을 규명하기 위해 PIV (Particle Image Velocimetry)를 이용하여 볼텍스챔버의 기하학적 변수에 따른 유동장 내부의 국소 유속분포를 측정하였다.
Transactions of the Korean Society of Automotive Engineers
/
v.12
no.6
/
pp.103-110
/
2004
The major trend in global automotive market is changing drastically in the way that a vehicle FECPS(Front End Cooling Pack System) is designed and manufactured as an assembly part. The system can encompass many functions, be assembled into a vehicle as a module, and reduce the production cost as well as time. The FECPS consists of an impact beam, an aluminum condenser and a radiator, a carrier and a cooling fan with a BLDC motor. In order to predict the performance of a FECPS accurately, it is essential to properly model the air flow field through various heat exchangers, such as a condenser or a radiator. In this study, the flow field of the system is measured by a PIV(Particle Image Velocimetry) system. The result is compared with that measured with multi-channel anemometer.
Journal of the Society of Naval Architects of Korea
/
v.41
no.4
/
pp.30-37
/
2004
Flow characteristics of the inflow ahead of a rotating propeller attached to a container ship model were investigated using a two-frame PIV (Particle Image Velocimetry) technique. Ensemble-averaged mean velocity fields were measured at four different blade phases. The mean velocity fields show the acceleration of inflow due to the rotating propeller and the velocity deficit in the near-wake region. The axial velocity distribution of inflow in the upper plane of propeller is quite different from that in the lower plane due to the thick hull boundary layer. The propeller inflow also shows asymmetric axial velocity distribution in the port and starboard side. As the inflow moves toward the propeller, the effect of phase angle variation of propeller blade on the inflow becomes dominant. In the upper plane above the propeller axis the inflow has very low axial velocity and large turbulent kinetic energy, compared with the lower plane. The boundary layer developed along the bottom surface of stern hull forms a strong shear layer affecting vortex structure of the propeller near-wake.
Chul H. Jo;Young S. Shin;Sung G. Hong;Kyoung H. Min;Chung, Kwang-Sic
Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
/
2001.05a
/
pp.254-259
/
2001
There are advantages in the installation of dual subsea pipelines over two separate single lines. In many case it can reduce the cost for trench, back-filling and installation. However the installation of dual pipelines often requires technical challenges. Dual Pipelines should be placed to be stable to external loading not only during the installation but also in the design life. Dual pipelines in trench can reduce the influence of external forces. To investigate applied forces as slope changes, number of experiments are conducted with PIV (Particle Image Velocimetry) in a circulating water channel. Numerical approaches are also made to compare with experimental results. The velocity fields around dual pipelines in trench are investigated and analysed. Comparison of both results show similar pattern of flow around dual pipelines. it is proved that the trench slope affects the pipeline stability significantly. The results can be applied in the stability design of dual pipelines in trench section. The complex flow patterns can be referenced effectively linked in the understanding of fluid around circular bodies in trench.
In this study, flow and creation and dissipation of vorticity around rectangular floating breakwater is investigated both experimentally and numerically. The PIV system(Particle image velocimetry) is employed to obtain the velocity field in the vorticity of rectangular structure. The numerical model, combined with ${\kappa}-{\varepsilon}$ turbulence model and the VOF method based on RANS equation, is used to analyze the turbulence structure. In the results of this study, the vorticity is found around conner of rectangular structure at all time domain, and creation and dissipation of vorticity are closely related to wave period. Separation points of phase of vortex due to flow separation for longer period waves are faster then for shorter period waves.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.