• Title/Summary/Keyword: Particle separation

Search Result 472, Processing Time 0.028 seconds

Development of volume reduction method of cesium contaminated soil with magnetic separation

  • Yukumatsu, Kazuki;Nomura, Naoki;Mishima, Fumihito;Akiyama, Yoko;Nishijima, Shigehiro
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.1
    • /
    • pp.10-13
    • /
    • 2016
  • In this study, we developed a new volume reduction technique for cesium contaminated soil by magnetic separation. Cs in soil is mainly adsorbed on clay which is the smallest particle constituent in the soil, especially on paramagnetic 2:1 type clay minerals which strongly adsorb and fix Cs. Thus selective separation of 2:1 type clay with a superconducting magnet could enable to reduce the volume of Cs contaminated soil. The 2:1 type clay particles exist in various particle sizes in the soil, which leads that magnetic force and Cs adsorption quantity depend on their particle size. Accordingly, we examined magnetic separation conditions for efficient separation of 2:1 type clay considering their particle size distribution. First, the separation rate of 2:1 type clay for each particle size was calculated by particle trajectory simulation, because magnetic separation rate largely depends on the objective size. According to the calculation, 73 and 89 % of 2:1 type clay could be separated at 2 and 7 T, respectively. Moreover we calculated dose reduction rate on the basis of the result of particle trajectory simulation. It was indicated that 17 and 51 % of dose reduction would be possible at 2 and 7 T, respectively. The difference of dose reduction rate at 2 T and 7 T was found to be separated a fine particle. It was shown that magnetic separation considering particle size distribution would contribute to the volume reduction of contaminated soil.

A Study on the Standard Criteria of Solid Particle Separation Test for Marine Centrifugal Purifier (선박용 정유기 고형분 분리 성능시험 규격기준에 관한 연구)

  • Jeong, Sang-Hu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.8
    • /
    • pp.1028-1034
    • /
    • 2007
  • In order to establish a criteria of solid particle separation performance test on marine centrifugal purifier at factory acceptance test, an investigation had been done on criteria of test standards, regulations and test specifications of purifier manufactures. KS V 7836, fuel oil and lubricating oil purifiers for marine use-centrifugal type, the criteria of solid particle separation is studied in the point of reality, restricts and analysis method. It is proposed that a reasonable criteria and analysis method should be adopted, and the current criteria shall be revised to adequate levels considering reasonable basis and industrial technology levels. Also, the test analysis conceptions, separation efficiency method and particle size restriction method, are reviewed to fulfil separation performance test for marine centrifugal purifiers.

Dry Separation of PVC Film from Plastic Film Mixture by Using Air Table

  • Song, Young-Jun;Hiroki Yotsumoto;Lee, Gye-Seung
    • Resources Recycling
    • /
    • v.11 no.1
    • /
    • pp.37-42
    • /
    • 2002
  • This study was conducted in order to remove Poly vinyl chloride(PVC) from the waste plastic film mixture. The fittings of Air Table was modified to increase the separation efficiency of PVC and PE(poly ethylene). PE and PVC was successfully separated from PVC-PE film mixture with the yield of PE 90% or more and with his grade of 99% or more, using the improved Air Table. The details of the separation condition and results will be discussed in this paper. Dry separation, Waste plastic film, PVC, Air Table. The details of the separation condition and results will be discussed in this paper.

Simulation analysis on the separation characteristics and motion behavior of particles in a hydrocyclone

  • Xu, Yanxia;Tang, Bo;Song, Xingfu;Sun, Ze;Yu, Jianguo
    • Korean Journal of Chemical Engineering
    • /
    • v.35 no.12
    • /
    • pp.2355-2364
    • /
    • 2018
  • We evaluated the effect of particle size and associated dynamics on a hydrocyclone separation process in order to understand the movement of the particle trajectories inside the hydrocyclone via numerical analysis, with particles of acid hydrolysis residues discharged in $TiO_2$ production via the sulfate method as a case study. The values obtained from the numerical simulation were successfully compared with those from experimental tests in the literature, allowing a description of the dynamics of the particles, their acting forces, and their relevant properties together with separation efficiency. The results showed that particle motion is jointly controlled by the drag force, the pressure gradient force and the centrifugal force. With increasing particle size, the influence of the drag force is weakened, whereas that of the centrifugal force and pressure gradient is strengthened. Factors including particle density, slurry viscosity, and inlet slurry flow rate also contribute to a clear and useful understanding of particle motion behavior in the hydrocyclone as a method for improving the separation efficiency.

A Numerical Study on the Triboelectrostatic Separation of PVC Materials From Mixed Plastics for Waste Plastic Recycling

  • Ha, Man-Yeong;Jeon, Chung-Hwan;Park, Doo-Seong;Park, Hae-Jin
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.10
    • /
    • pp.1485-1495
    • /
    • 2003
  • We investigate the triboelectrostatic separation of polyvinylchloride (PVC) from mixed plastics in the laboratory scale triboelectrostatic separation system. The flow and electric fields in the precipitator are obtained from the numerical solution of finite volume method. Using these flow and electric fields, we solved the particle motion equation considering the inertia, drag, gravity and electrostatic forces acted on the particles. The particle trajectories are obtained using a Lagrangian method as a function of different important variables such as Reynolds number, Stokes number, electrostatic force, electric charge and electric field distribution, inclined angle of plane electrodes, particle rebounding, particle charge decay rate after impact on the electrode surface, etc., in order to determine the optimal design conditions. The present predicted results for the cumulative yield represent well the experimental ones.

A Continuous Particle-size Sorter Using Negative a Dielectrophoretic Virtual Pillar Array (음의 유전영동에 의한 가상 기둥 어레이를 이용한 연속적 입자 크기 분류기)

  • Chang, Sung-Hwan;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.11
    • /
    • pp.824-831
    • /
    • 2008
  • We present a continuous size-dependent particle separator using a negative dielectrophoretic (DEP) virtual pillar array. Two major problems in the previous size-dependent particle separators include the particle clogging in the mechanical sieving structures and the fixed range of separable particle sizes. The present particle separator uses the virtual pillar array generated by negative DEP force instead of the mechanical pillar array, thus eliminating the clogging problems. It is also possible to adjust the size of separable particles since the size of virtual pillars is a function of a particle diameter and applied voltage. At an applied voltage of 500 kHz $10\;V_{rms}$ (root mean sqaure voltage) sinusidal wave and a flow rate of $0.40\;{\mu}l\;min^{-1}$, we separate $5.7\;{\mu}m$-, $8.0\;{\mu}m$-, $10.5\;{\mu}m$-, and $11.9\;{\mu}m$-diameter polystyrene (PS) beads with separation purity of 95%, 92%, 50%, and 63%, respectively. The $10.5\;{\mu}m$- and $11.9\;{\mu}m$-diameter PS beads have relatively low separation purity of 50% and 63%. However, at an applied voltage of $8\;V_{rms}$, we separate $11.9\;{\mu}m$-diameter PS beads with separation purity over 99%. Therefore, the present particle separator achieves clog-free size-dependent particle separation, which is capable of size tuning of separable particles.

Dry separation of PVC film from waste plastic film mixture using Air Table

  • Song, Young-Jun;Hiroki Yotsumoto;Eisetsu Oi
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.734-737
    • /
    • 2001
  • A study was conducted in order to remove PVC from the waste plastic film mixture. The fittings of Air Table was modified to increase the separation efficiency of PVC. By using the improved air table, the PE and PVC was successfully separated from PVC-PE film mixture with the yield of PE 90% or more and with the content of PVC in PE 1% or less. The detail of the separation condition and result will be discussed in this paper.

  • PDF

Electrostatic Charging Measurement and PVC Separation of Triboeletrostatically Charged Plastic Particles using a Fluidized Bed Tribocharger

  • Shin, Jin-Hyouk;Lee, Jae-Keun
    • Journal of ILASS-Korea
    • /
    • v.7 no.2
    • /
    • pp.7-15
    • /
    • 2002
  • A particle flow visualization, electrostatic charging measurement and separation of triboelectrically charged particles in the external electric field by a fluidized bed tribocharger are conducted for the removal of PVC particles from mixed waste plastics. The laboratory-scale triboelectrostatic separation system consists of the fluidized bed tribocharger, a separation chamber, a collection chamber and a controller. PVC and PET particles can be imparted negative and positive surface charges respectively due to the difference of triboelectric charging series between particles and particles in the fluidized bed tribocharger, and can be separated by passing them through an external electric field. To visualize these charged particles, He-Ne laser is used with cylindrical lenses to generate a sheet beam. In the charging measurement, the particle motion analysis system (PMAS), capable of determining particle velocity and diameter. is used to non-intrusively measure particle behavior in high strength electric field. The average charge-to-mass ratios of PVC and PET particles are $1.4\;and\;1.2{\mu}C/kg$, respectively. The highly concentrated PVC (91.9%) can be recovered with a yield of about 96.1% from the mixture of PVC and PET materials for a single-stage processing. The triboelectrostatic separation system using the fluidized tribocharger shows the potential to be an effective method for removing PVC from mixed plastics for waste plastic recycling.

  • PDF

A Study on the Preparation of a Linear Low Density Polyethylene particles by Thermally Induced Phase Separation (열유도 상분리에 의한 선형 저밀도 폴리에틸렌 입자 제조에 관한 연구)

  • Park, Keun-Ho;Jang, Young-Min
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.386-392
    • /
    • 2011
  • We are crystallized to the linear low density polyethylene(LLDPE) particles by a thermally induced phase separation(TIPS). TIPS process based on the phase separation mechanism was performed for the LLDPE system which undergoes liquid-solid phase separation. The linear low density polyethylene particle formation occurred by the nucleation and growth mechanism in the metastable region. Although the growth rates depended on the experimental conditions such as the polymer concentration and temperature, the particles were larger when the polymer concentration was higher or temperature was higher. The particles were observed by SEM. The LLDPE particle size distribution became broader when the polymer concentration was higher.