• Title/Summary/Keyword: Particle measurement

Search Result 1,196, Processing Time 0.047 seconds

Automatic Extraction of Particle Streaks for 3D Flow Measurement

  • Kawasue, Kikuhito;Ohya, Yuichiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.270-273
    • /
    • 1999
  • Circular dynamic stereo has special advantages as it enables a 3-D measurement using a single TV camera and also enables a high accurate measurement without a cumbersome calibration. Annular particle streaks are recorded using this system and the size of annular streaks directly concerns to the depth from TV camera. That is, the size of annular streaks is inversely proportional to the depth from the TV camera and the depth can be measured automatically by image processing technique. Overlapped streaks can be processed also by our method. The flow measurement in a water tank is one of the applications of our system. Tracer particles are introduced into the water in a flow measurement. Since the tracer particles flow with water, three-dimensional velocity distributions in the water tank can be obtained by measuring the all movement of tracer particles. Experimental results demonstrate the feasibility of our method.

  • PDF

Real-time High Resolution PM Monitoring in Seoul (서울지역 미세먼지의 실시간 고해상도 모니터링 방안)

  • Kang, Doo Soo;Bong, Choon Keun;Kim, Dae Seong
    • Particle and aerosol research
    • /
    • v.15 no.2
    • /
    • pp.67-78
    • /
    • 2019
  • Since existing measurement sites are required to construct a high-cost PM measuring device and a measuring site of a large area, there is a limit to the construction of a high-resolution measurement network. Therefore, it is necessary to develop a low-cost, high-performance PM measuring device (as an alternative technology) that can increase the resolution of PM measurement, and it is necessary to establish a base to provide real-time PM information for whole people. Therefore, in this study, the alternative technique (light scattering method) for achieving the above object was examined, performance evaluation was carried out, and it was verified that the light scattering method was usable. Various PM measurement results were compared and analyzed to find PM monitoring points and resolutions we would like to propose.

Determination of the number of 235U target nuclei in the irregular target using a fission time projection chamber

  • Jiajun Zhang;Jun Xiao;Junjie Sun;Mingzhi Zhang;Taiping Peng;Pu Zheng
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.444-450
    • /
    • 2024
  • Based on multiple measurements of ionization loss, the Time Projection Chamber (TPC) combines strong tracking ability with particle identification ability in a large momentum range, which is an important advantage of TPC detection technology over traditional ionization measurement technology. According to these two characteristics of TPC, applying it to the measurement of fission cross-section can greatly improve the measurement accuracy. During the measurement of the fission cross-section, the number of target nuclei is required to be accurately measured. So this paper introduces a method for measuring the number of 235U target nuclei using a fission TPC system. The measurement result agrees with the reference value, and relative error is around 1 %.

Field Measurement of Suspended Material Distribution at the River Confluence (하천 합류부에서의 부유입자 분포에 대한 현장측정)

  • Kwak, Sunghyun;Lee, Kyungsu;Cho, Hanil;Seo, Yongjae;Lyu, Siwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.467-474
    • /
    • 2017
  • Each river confluence has the inherent hydraulic and mixing characteristics coming from its bathymetry and topography. It is necessary to make the measurement covering the spatial extent of studying area in order to catch these 2-dimensional intrinsic characteristics. This study focuses to investigate the hydraulic and mixing characteristics at the confluence of Nakdong and Geumho River, from field measurement of flow, water quality, and suspended particle distribution with ADCP (Riversurveyor M9), multi-parameter water quality sonde (YSI6600V2), and submersible system for in-situ observations of particle size distribution and volume concentration (LISST : Laser In-Situ Scattering & Transmissometry), respectively. From the results, it can be found that the field measurement of suspended particle and water quality distribution can be the useful approach to catch the hydraulic and mixing characteristics at a river confluence.

Effect of DPF Regeneration on the Nano Particle Emission of Diesel Passenger Vehicle (DPF 재생이 경유승용차의 미세입자 배출에 미치는 영향 연구)

  • Kwon, Sang-Il;Park, Yong-Hee;Kim, Jong-Choon;Lee, Chang-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.153-159
    • /
    • 2007
  • Nano-Particles are influenced on the environmental protection and human health. The relationships between transient vehicle operation and nano-particle emissions are not well-known, especially for diesel passenger vehicles with DPF. In this study, a diesel passenger vehicle was measured on condition of DPF regeneration and no regeneration on a chassis dynamometer test bench. The particulate matter (PM) emission from this vehicle was measured by its number, size and mass measurement. The mass of the total PM was evaluated with the standard gravimetric measurement method while the total number and size concentrations were measured on a NEDC driving cycle using Condensation Particle Counter (CPC) and EEPS. Total number concentration by CPC was $1.5{\times}10^{1l}N/km$, which was 20% of result by EEPS. This means about 80% of total particle emission is consist of volatile and small-sized particles(<22nm). During regeneration, particle emission was $6.2{\times}10^{12}N/km$, was emitted 400 times compared with the emission before regeneration. As for the particle size of $22{\sim}100nm$ was emitted mainly, showing peak value of near 40nm in size. This means regeneration decreased the mean size of particles. Regarding regeneration, PM showed no change while the particle number showed about 6 times difference between before and after regeneration. It seems that the regeneration influences on particle number emissions are related to DPF-fill state and filtration efficiency.

Effect of Performance of Aerosol Charge Neutralizers on the Measurement of Highly Charged Particles Using a SMPS (에어로졸 중화기의 성능이 고하전 입자의 크기분포 측정에 미치는 영향)

  • Ji, Jun-Ho;Bae, Swi-Nam;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1498-1507
    • /
    • 2003
  • A SMPS(scanning mobility particle sizer) system measures the number size distribution of particles using electrical mobility detection technique. An aerosol charge neutralizer, which is a component of the SMPS, is a bipolar charger using a radioactive source to apply an equilibrium charge distribution to aerosols of unknown charge distribution. However, the performance of aerosol charge neutralizers is not well known, especially for highly charged particles. In this study, the effect of the particle charging characteristics of two aerosol charge neutralizers on the measurement using a SMPS system was experimentally investigated for highly charged polydisperse particles. One has radioactive source of $^{85}$ Kr (beta source, 2 mCi) and the other has $^{210}$ Po (alpha source, 0.5 mCi). The air flow rate passing through each aerosol charge neutralizer was changed from 0.3 to 3.0 L/min. The results show that the non-equilibrium character in particle charge distribution appears as the air flow rate increases although the particle number concentration is relatively low in the range of 1.5∼2x10$^{6}$ particles/㎤. The low neutralizing efficiency of the $^{85}$ Kr aerosol charge neutralizer for highly charged particles can cause to bring an artifact in the measurement using a SMPS system. However, the performance of the $^{210}$ Po aerosol charge neutralizer is insensitive to the air flow rate.

Determination of In-focus Criteria In Image Processing Method for Particle Size Measurement (입경측정을 위한 영상처리기법에서 입자 초점면 존재 판단 기준의 설정)

  • Koh, Kwang Uoong;Kim, Joo Youn;Lee, Sang Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.3
    • /
    • pp.398-407
    • /
    • 1999
  • In the present image processing technique, the concept of the gradient indicator(GI) has been introduced to find out the depth-of-field in sizing large particles ranging from $30{\mu}m$ to $30{\mu}m$ where using of the concept of the normalized contrast value(VC) is not appropriate. The gradient indicator is defined as the ratio of the local value to the maximum possible value of the gray-level gradient in an image frame. The gradient indicator decreases with the increases of the particle size and the distance from the exact focal plane. A particle is considered to be in focus when the value of the gradient indicator at its image boundary stays above a critical value. This critical gradient indicator($GI_{critical}$) is defined as the maximum gradient indicator($GI_{max}$) subtracted by a constant ${\Delta}GI$ which is to account for the particle-size effect. In the present ca.so, the value of ${\Delta}GI$ was set to 0.28 to keep the standard deviation of the measured particles mostly within 0.1. It was also confirmed that, to find the depth-of-field for small particles(${\leq}30{\mu}m$) with the same measurement accuracy, tho concept of the critical normalized contrast($VC_{critical}$) is applicable with 85% of the maximum normalized contrast value($VC_{max}$). Finally, the depth-of-field was checked for the size range between $10{\mu}m$ and $300{\mu}m$ when the both in-focus criteria ($GI_{critical}$ and $VC_{critical}$) were adopted. The change of the depth-of-field with the particle size shows good linearity in both the VC-applicable and the GI-applicable ranges with a reasonable accuracy.

Application of PIV in a Transonic Centrifugal Impeller

  • Hayami Hiroshi;Hojo Masahiro;Aramaki Shinichiro
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.1-5
    • /
    • 2001
  • A particle image velocimetry (PIV) was applied to a flow measurement in a transonic centrifugal impeller. A phase locked measurement technique every $20\%$ blade pitch enabled a reconstruction of a velocity field over one blade pitch. The measured velocity field at the inducer of impeller clearly showed a shock wave generated on the suction surface of a blade.

  • PDF

A Study on Bubbly Flow using PIV Measurement (PIV 법을 이용한 기포유동에 관한 연구)

  • 배대석;권오봉
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.898-903
    • /
    • 2001
  • The particle image velocimetry with liquid crystal tracers is used for visualizing and analysis of the bubbly flow in a vertical temperature gradient. This method allows simultaneous measurement of velocity and temperature field at a given instant of time Quantitative data of velocity were obtained by applying the MQD technique to visualized image. The paper describes the method, and presents the transient velocity patterns of bubbly flow.

  • PDF