• 제목/요약/키워드: Particle Image Velocimetry

검색결과 642건 처리시간 0.029초

PIV를 이용한 점탄성 유체의 특성 확산시간에 대한 측정 (Experiment of Characteristic Diffusion Time of Viscoelastic Fluid by Particle Image Velocimetry)

  • 전찬열
    • 한국산학기술학회논문지
    • /
    • 제3권4호
    • /
    • pp.251-256
    • /
    • 2002
  • 폴리머용액의 특성확산시간은 낙구의 종말속도를 측정함으로써 결정할 수 있다. 확산시간은 폴리머 용액의 농도가 증가할수록 증가한다. 입자영상유속장치 (PIV)를 이용하여 구주위의 유동현상을 가시화 하였다. 2000 ppm의 경우 30 초 간격으로 떨어뜨렸을때의 속도가 0초( 처음)나 40초후, 50초후에 떨어뜨렸을때와 비교하여 가장 크게 나타났다. 뉴톤 유체에서는 낙구의 전방과 후방에서 구주위의 유동장이 동일하게 나타났다.

  • PDF

PIV기법에 의한 엇갈린 관군 배열 내부의 유동장 측정 (Measurement of Flow Field through a Staggered Tube Bundle using Particle Image Velocimetry)

  • 김경천;최득관;박재동
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.595-601
    • /
    • 2001
  • We applied PIV method to obtain instantaneous and ensemble averaged velocity fields from the first row to the fifth row of a staggered tube bundle. The Reynolds number based on the tube diameter and the maximum velocity was set to be 4,000. Remarkably different natures are observed in the developing bundle flow. Such differences are depicted in the mean recirculating bubble length and the vorticity distributions. The jet-like flow seems to be a dominant feature after the second row and usually skew. However, the ensemble averaged fields show symmetric profiles and the flow characteristics between the third and fourth measuring planes are not so different. comparison between the PIV data and the RANS simulation yields severe disagreement in spite of the same Reynolds number. It can be explained that the distinct jet-like unsteady motions are not to be accounted in th steady numerical analysis.

  • PDF

평행평판 전극사이에서 PIV 기법을 이용한 ER 유체의 유동특성에 관한 실험적 연구 (Experimental Study on Flow Characteristics of ERF Between Two Parallel-Plate Electrodes by using PIV Technique)

  • 장태현;장기원
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2003년도 추계학술대회 논문집
    • /
    • pp.103-106
    • /
    • 2003
  • An experimental investigation was peformed to study the characteristics of ER(Electro-Rheological) fluid water flow in a horizontal rectangular tube with or without D.C volatage. To determine some characteristics of the ER flow, 2D PIV(Particle Image Velocimetry) technique is employed for velocity measurement. This research found the mean velocity distribution with 0 kV/mm, 1.0kV/mm and 1.5kV/mm for Re = 0, 0.62, 1.29 and 2.26. When the strength of the electric field increased, the claster of ERF are clearly strong along the test tube and the flow rate decreased.

  • PDF

병렬평면제트의 유동특성 (Flow Characteristics of Parallel Plane Jets)

  • 김동건;윤순현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.823-826
    • /
    • 2002
  • Experiments were conducted to show the characteristics of the flow on unventilated parallel plane jets. Measurements of mean velocity components and turbulent intensities were carried out with a particle image velocimetry. The measurements range of these experiments was Reynolds number of 5300 based on the nozzle width and the cases of nozzle-to-nozzle distance were 4, 6, 8, and 10 times the width of the nozzle. Results show that a recirculation zone with a sub-atmospheric static pressure was bounded by the inner shear layers of the individual jets and the nozzles plate. The positions, where maximum value of mean turbulent intensities and mean turbulent kinetic energy show, were at the same position with the merging point. The spread of jets in the merging region increases more rapidly than that of jets in the converging and the combined region. As nozzle-to-nozzle distances were increased, it was shown that merging and combined lengths were shorter.

  • PDF

판형-핀 열교환기 분배면의 유동 가시화 연구 (Flow Visualization Study around the Distributor of Plate-fin Heat Exchangers)

  • 정태식;박승하;김창수;김형범
    • 한국가시화정보학회지
    • /
    • 제10권3호
    • /
    • pp.37-41
    • /
    • 2012
  • Plate-fin heat exchanger is a kind of compact heat exchangers with a good performance in heat transfer. It is widely used in various engineering fields such as aerospace, chemical and biomedical industries. Quantitative and qualitative flow visualization study were performed using the water model of commercial plate-fin heat exchanger with header angles of $30^{\circ}$. The Reynolds number was 100. Conventional digital particle image velocimetry was used to measure the instantaneous velocity fields of the header region and the flow visualization using dye injection and hydrogen bubble method were applied to capture the qualitative flow characteristics. The results showed the existence of separation flow region at the junction area and the bottom wall of the exit region.

Behavior Characteristics of Density Currents Due to Salinity Differences in a 2-D Water Tank

  • Lee, Woo-Dong;Mizutani, Norimi;Hur, Dong-Soo
    • 한국해양공학회지
    • /
    • 제32권4호
    • /
    • pp.261-271
    • /
    • 2018
  • In this study, a hydraulic model test, to which Particle Image Velocimetry (PIV) system applied, was used to determine the hydrodynamic characteristics of the advection-diffusion of saltwater according to bottom conditions (impermeable/permeability, diameter, and inclination) and the difference of the initial salt. Considering quantitative and qualitative results from the experiment, the characteristics of the density current were discussed. As an experimental result, the advection-diffusion mechanism of salinity was examined by the shape of saltwater wedge and the flow structure of density currents with various bottom conditions. The vertical salt concentration obtained from the experiment was used as quantitative data to calculate the diffusion coefficient that was used in the numerical model of the advection-diffusion of saltwater.

An Experimental Study on Flow Characteristics of ERF Between Two Parallel-Plate Electrodes by Using PIV Technique

  • Chang, Tae-Hyun;Jang, Sung-Cheol
    • Journal of Mechanical Science and Technology
    • /
    • 제18권10호
    • /
    • pp.1763-1771
    • /
    • 2004
  • An experimental investigation was performed to study the characteristics of ER (Electro-Rheological) fluid flow in a horizontal rectangular tube with or without D. C voltage. To determine some characteristics of the ER flow, 2D PIV(Particle Image Velocimetry) technique was employed for velocity measurements. This research found the mean velocity distributions with 0kV /mm, l.0kV /mm and l.5kV /mm for Re=0, 0.62, 1.29 and 2.26. When the strength of the electric field increased, the cluster of ERF was clearly strong along the test tube and the flow rate decreased. The present results will contribute to the economical and compact design of ER fluids system.

Investigation on Airflows in Abnormal Nasal Cavity with Adenoid Vegetation by Particle Image Velocimetry

  • Kim, Sung Kyun;Son, Young Rak
    • Journal of Mechanical Science and Technology
    • /
    • 제18권10호
    • /
    • pp.1799-1808
    • /
    • 2004
  • Knowledge of airflow characteristics in nasal cavity is essential to understand the physiological and pathological aspects of nasal breathing. Several studies have utilized physical models of the healthy nasal cavity to investigate the relationship between nasal anatomy and airflow. Since the final goal of these works is their contribution to the diagnosisand treatment of nasal diseases, the next step on this topic is naturally studies for disordered nasal cavities. In this paper, as the first application, airflows in the normal and abnormal nasal cavities with adenoid vegetation are investigated experimentally by PIV, and comparisons of both cases are appreciated. Dense CT data and careful treatment of model surface under the ENT doctor's advice provide more sophisticatedcavity model. The CBC PIV algorithm with window offset is used for PIV flow analysis. Average and RMS distributions are obtained for inspirational and expirational nasal airflows. Airflow characteristics that are related with the abnormalities in nasal cavity are presented.

교반혼합기 내의 거대유동에 대한 PIV측정 (PIV Measurement of Bulk Flow in a Stirring Mixer)

  • 김상기;김경천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.680-685
    • /
    • 2000
  • Liquid flow in a stirring mixer driven by a six-blade turbine has been investigated experimentally. The flows were quantified by measurements of velocity characteristics. obtained by a Particle Image Velocimetry(PIV). for a blade rotational speed of 100r.p.m. and for two blade clearances from the bottom of the tank. The instantaneous flow fields show that the bulk flow consists of small scale vortices very complicately. However, the mean flow results show that the formation of ring vortices above and below the blade. which depend on the clearance.

  • PDF

공기 유입을 고려한 2유체 분무의 구조에 관한 실험적 연구 (An Experimental Study on Structure of Twin-Fluid Spray with Air Entrainment)

  • 채효철;김동일;오상헌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.925-930
    • /
    • 2000
  • This paper is investigated the entrainment of air into sprays which has significant effects on the combustion efficiency, stability of flame using the air-assisted twin-fluid nozzle in non-burning. The factors which may be expected to affect the entrainment of air by a liquid spray are: Relative velocity of droplet and ambient gas; Drop size and size distribution; Density and other property of the liquid. Here, axial, radial velocity and turbulent kinetic energy of spray droplet was measured with the PIV(Particle Image Velocimetry). Spray characteristics were also visualized using CCD camera. The results indicate that the entrainment rate increases more or less non-linearly with the downstream region.

  • PDF