• Title/Summary/Keyword: Partial resonance

Search Result 224, Processing Time 0.031 seconds

Clinical outcome of ultrasound-guided atelocollagen injection for patients with partial rotator cuff tear in an outpatient clinic: a preliminary study

  • Chae, Sang Hoon;Won, Jae Yeon;Yoo, Jae Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.2
    • /
    • pp.80-85
    • /
    • 2020
  • Background: Atelocollagen has been studied for restoration of rotator cuff tendon. In this study, we attempted to evaluate the clinical outcome of ultrasound-guided atelocollagen injection in an outpatient clinic for patients with partial rotator cuff tear. Methods: We recruited 42 outpatients who visited our hospital from May 2019 to September 2019. Atelocollagen injection was performed in patients with partial rotator cuff tear diagnosed by magnetic resonance imaging and ultrasound. American Shoulder and Elbow Surgeons (ASES), Constant, Korean Shoulder Score (KSS) and Simple Shoulder Test (SST) scores, and range of motion were assessed before injection and after 2 months. Statistically, we analyzed the clinical results using the Wilcoxon signed-rank test. Results: Finally, 15 patients were enrolled for analysis. There was no significant difference between pre- and post-injection in terms of range of motion, ASES (57.0 vs. 60.4), Constant (56.4 vs. 58.9), KSS (64.6 vs. 68.5), and pain-visual analog scale (4.2 vs. 3.7), except function-visual analog scale (F-VAS; 6.3 vs. 7.1) and SST (6.6 vs. 6.9). A significant difference was found in SST (P=0.046) and F-VAS (P=0.009). According to the ultrasound results at 2 months, we found hyperechoic materials in three of seven patients. The most common complication of atelocollagen injection was post-injection pain (53%, 8/15). Conclusions: Ultrasound-guided atelocollagen injection for partial rotator cuff tear showed no significant change in terms of clinical outcomes, except for F-vas and SST score. Tendon regeneration was not clear due to the remnants of atelocollagen present at 2-month follow-up ultrasound. There seems to be alarming post-injection pain for 2 to 3 days in the patients who received atelocollagen injection in an outpatient clinic.

Calculation and Application of Partial Charges (부분 전하의 계산과 응용)

  • Cho, Seung Joo
    • Journal of Integrative Natural Science
    • /
    • v.3 no.4
    • /
    • pp.226-230
    • /
    • 2010
  • Calculation of partial charge is important in chemistry. However, because there are many methods developed, it is of considerable interest to know how to calculate and apply properly to address various chemical problems. For basis set, usually double zeta quality is acceptable, and double zeta polarization function would be enough for most cases. To describe electronic state more accurately, Many electron configurations would be necessary to describe highly strained or anionic species. The NPA population introduced new concept about amide bonds, i.e., the planar geometry of nitrogen atom may not come from resonance, but from the lowering of p-orbital energy by electronegative carbonyl carbon atom. The issues for hypervalent atomic charges was also addressed by various charge derivation scheme. When the charge schemes were applied to organolithium compounds, the ionic nature of boding was revealed. This comes from the fact that previous Mulliken partial atomic charges overemphasized the covalent character, wihout much justification. The other partial charge derivation schemes such as NPA(natural population analysis), IPP (Integrated Projected Population) showed that much more ionic picture. ESP potential derived charges are generally believed to be suitable to describe intermolecular interactions, therefore they are used for molecular dynamics simulations and CoMFA (comparative molecular field analysis). The charge derivation schemes using multipole polarization was mainly applied to reproduce experimental infrared spectroscopy. In some reports these schemes are also suitable for intermecular electrostatic interactions. Charges derived from electron density gradient have shown the some bonds are not straight, but actually bent. The proper choice of charge-calculation method along with suitable level of theory and basis set are briefly discussed.

Region of Interest Analysis for Standardized Uptake Value Ratio of 18F-fludeoxyglucose PET: Mild Cognitive Impairment and Alzheimer's Disease (경도인지장애와 알츠하이머병 환자의 18F-fludeoxyglucose PET 표준 섭취계수율에 대한 체적 및 피질 표면 기반 관심영역 분석)

  • Kim, Seonjik;Yoon, Uicheul
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.237-242
    • /
    • 2018
  • $^{18}F$-fludeoxyglucose PET (FDG-PET) can help finding an abnormal metabolic activity in brain. In this study, we evaluated an efficiency of volume- and cortical surface-based analysis which were used to determine whether standardized uptake value ratio (SUVR) of FDG-PET was different among Alzheimer's disease (AD), mild cognitive impairment (MCI), and healthy control (HC). Each PET image was rigidly co-registered to the corresponding magnetic resonance imaging (MRI) using mutual information. All voxels of the co-registered PET images were divided by the mean FDG uptake of the cerebellum cortex which was thresholded by partial volume effect (>0.9). Also, the SUVR value of each vertex was linearly interpolated from volumetric SUVR image which was thresholded by gray matter partial volume effect (>0.1). Lobar mean values were calculated from both volume- and cortical surface-based SUVRs. Statistical analysis was conducted to compare two measures for AD, MCI and HC groups. Even though the results of volume (SUVR_vol) and cortical surface-based SUVR (SUVR_surf) analysis were not significantly different from each other, the latter would be better for detecting group differences in SUVR of PET.

A Study for Anatomical Evidence of Anxiety Using Magnetic Resonance Imaging in Patients with Panic Disorder and Complex Partial Seizure (공황장애와 복합부분간질 환자의 뇌자기공명촬영소견을 통한 불안의 해부학적 증거에 대한 연구)

  • Choi, Byung-Hwi;Lee, Young-Ho;Chung, Young-Cho
    • Korean Journal of Biological Psychiatry
    • /
    • v.2 no.1
    • /
    • pp.107-114
    • /
    • 1995
  • This study was to investigate the anatomical evidence of anxiety. MRI was used to study 11 patients with panic disorder and 15 patients with complex partial seizure, and 21 controls. The regions of interest in the MRI were measured with computer-assisted planimetry using the AutoCad and digitizer. The following results were obtained ; 1) The mean age was 49.7(12.4) years in patients with panic disorder and 30.1(7.5) years in patients with complex partial seizure. 2) There were na signi ficant differences between 3 groups in the values of cerebral area, temporal lobe, caudate nucleus, hippocampus, parahippocampus, amygdala, third ventricle and VBR. The right parahippocampal region which attracted most attention in neurobiological studies regarding anxiety, tended to be larger in both study groups compared to the control group, but with no statistical significance. 3) There was lett-right reversal of temporal lobes in both study groups. And these are mainly due to asymmetrical increase in area of the temporal lobe on right side. These results suggest that temporal lobe, especially right temporal, is the anatomical correspondence of anxiety and functional activation of temporo-limbic system may be accompanied by the structural change of temporal lobe.

  • PDF

Comparative Study between MRI and pain, duration, physical examination in 20 patients with knee joint pain (20례 슬통환자의 통증, 이환기간, 물리적 검사법과 MRI소견과의 비교 고찰)

  • Yang, Myung-bok;Jang, Byung-sun;Lee, Dae-yong;Lee, Seung-hoon;Hwang, Byung-chun;Park, Jung-un;Guk, Ui-suk;Lee, Geon-mok
    • Journal of Acupuncture Research
    • /
    • v.19 no.6
    • /
    • pp.221-233
    • /
    • 2002
  • Background and Purpose : MRI(Magnetic Resonance Imaging) has become one of the most sensitive diagnostic tool no evaluate problems of the knee, because it enables us to identify not only osseous tissue but also soft tissues including muscle, fascia, tendon, ligament, meniscus and fat around the knee joint. Objective : To compare between MRI reading and pain, duration, physical examination in patients with pain of knee joint. Methods : 20 patients with pain of knee joint included in this study. This study researched pain-degree, duration, physical examination with pain of knee joint. Using MRI(Horizon Lx 1.0T-GE), we obtained the results. Results : 1. In the distribution of sex; Female rate was 80.0% and male rate was 20.0%. In the distribution of age, above sixty group was the largest group by each 55.0%. 2. In the distribution of MRI reading; 'Meniscus horm tear' was 70.0%, 'Osteoarthritis' was 55.5%, 'ACL partial tear' was 15.0%, 'Bone bruise at tibia, femur' was 15.0%. 3. Correlation between duration of pain and MRI reading showed that acute and subacute stage related various MRI reading, that chronic stage related 'Osteoarthritis' and 'Meniscus horn tear' by each 69.2%, 92.3%. 4. Correlation between pain and MRI reading showed that severe pain(GVI) related 'ACL partial tear, PCL partial tear' by each 100%, that mild pain(GII) related 'Osteoarthritis, Meniscus horn tear' by each 70.0%, 80.0%. 5. Correlation between physical examination and MRI reading showed that Drawer test related ACL partial tear by each 60.0%, that McMurray test related 'Meniscus horn tear' by each 75.0%. 6. Correlation between effect of treatment and MRI reading showed that 'Osteoarthritis, Meniscus horn tear' related good effect, that ACL partial tear related poor effect. Conclusions : These results suggest that acute and sever pain relate 'ACL partial tear, PCL partial tear', that chronic and mild pain related 'Osteoarthritis, Meniscus horn tear'. So it is responsibility to use MRI as a sensitive diagnostic tool in the knee problems.

  • PDF

Stability measurements on the implants of mandibular molar area using OsstellTM (OsstellTM을 이용한 하악구치부 임플랜트의 안정성 측정)

  • Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.3
    • /
    • pp.205-211
    • /
    • 2001
  • The aim of this investigation was to evaluate successfully functioning implants stability in the partially edentulous mandibular molar sites by resonance frequency measurements. Resonance frequency measurement is more objective and clinically non-invasive method than any other methods had been used. In this study, $Osstell^{TM}$ (Integration Diagnostics, Sweden) was used. 15 patients ( 7 males, 8 females ) were received each 2 implants in their mandibular unilaterally partial edentulous molar sites. Total 30 implants were installed, 28 implants were $Br{\aa}nemark^{(R)}$ self-tapping fixtures(MK II, Nobel Biocare, Sweden) and 2 were $3i^{(R)}$(USA) self-tapping fixtures. Minimum of functional loading durations was 12 months and there were no significant marginal bone resorptions and peri-implant problems. From this test, the following results were drawn: 1. Mean ISQ values of implants in the first and second mandibular molar area were $73.66{\pm}4.45$, $71.93{\pm}3.41$, respectively. There was no significant difference between two groups(p>0.05). Also mean ISQ value of total sum was 72.8. 2. Mean ISQ values of implants in males and females group were $71.64{\pm}4.06$, $73.81{\pm}3.76$, respectively. And there was no significant difference between two group(p>0.05). 3. Correlation between implant lengths and ISQ values was weak(r=0.128).

  • PDF

Simultaneous Medial and Lateral Discoid Meniscus in one Knee joint (한쪽 슬관절에서 내측 및 외측에 동시에 발생한 원판형 연골 - 1예 보고 -)

  • Cho, Young-Ho;An, Hyug-Su;Chang, Se-Ang;Nam, Seung-Oh
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.95-98
    • /
    • 2006
  • Most of discoid menisci are lateral and medial discoid meniscus is very rare. There is no report about simultaneous medial and lateral discoid meniscus in one knee joint. A 15-year-old male patient was diagnosed as having a complete medial discoid meniscus with horizontal tear and intact incomplete lateral discoid meniscus by means of magnetic resonance image and arthroscopy. The patient was treated by arthroscopic partial meniscectomy for both discoid menisci.

  • PDF

Non-linear vibration and stability analysis of an axially moving rotor in sub-critical transporting speed range

  • Ghayesh, Mergen H.;Ghazavi, Mohammad R.;Khadem, Siamak E.
    • Structural Engineering and Mechanics
    • /
    • v.34 no.4
    • /
    • pp.507-523
    • /
    • 2010
  • Parametric and forced non-linear vibrations of an axially moving rotor both in non-resonance and near-resonance cases have been investigated analytically in this paper. The axial speed is assumed to involve a mean value along with small harmonic fluctuations. Hamilton's principle is employed for this gyroscopic system to derive three coupled non-linear equations of motion. Longitudinal inertia is neglected under the quasi-static stretch assumption and two integro-partial-differential equations are obtained. With introducing a complex variable, the equations of motion is presented in the form of a single, complex equation. The method of multiple scales is applied directly to the resulting equation and the approximate closed-form solution is obtained. Stability boundaries for the steady-state response are formulated and the frequency-response curves are drawn. A number of case studies are considered and the numerical simulations are presented to highlight the effects of system parameters on the linear and nonlinear natural frequencies, mode shapes, limit cycles and the frequency-response curves of the system.

Medulloblastoma Manifesting as Sudden Sensorineural Hearing Loss

  • Terakawa, Yuzo;Tsuyuguchi, Naohiro;Takami, Toshihiro;Ohata, Kenji
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.1
    • /
    • pp.51-53
    • /
    • 2011
  • We present a rare case of medulloblastoma which presented with unilateral sudden sensorineural hearing loss as an initial symptom. A 19-year-old man was admitted to our hospital with a chief complaint of dizziness and facial numbness on the right side. His illness had begun two years previously with sudden hearing loss on the right side, for which he had been treated as an idiopathic sudden hearing loss. Magnetic resonance imaging demonstrated abnormal signals located mainly in the right middle cerebellar peduncle. We performed partial resection of the tumor by suboccipital craniotomy. The histopathological diagnosis was medulloblastoma. Intrinsic brain tumor is an extremely rare cause of sudden sensorineural hearing loss and is therefore easily overlooked as was in the present case. The present case highlights not only the need to evaluate patients with sudden sensorineural hearing loss by magnetic resonance imaging but also the importance of paying attention to intrinsic lesions involving the brainstem. Although this condition like the presented case might be rare, intrinsic brain tumor should be considered as a potential cause of sudden sensorineural hearing loss, as it may be easily missed leading to a delay in appropriate treatment.

Signal amplification by reversible exchange in various alcohol solvents

  • Jeong, Hye Jin;Namgoong, Sung Keon
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.25 no.4
    • /
    • pp.64-69
    • /
    • 2021
  • In the developed NMR hyperpolarization techniques, Signal amplification by reversible exchange (SABRE) technique is thought to be a promising method to overcome the low sensitivity of bio-NMR/MRI. Most experiments using SABRE have been done in methanol, which is biologically harmful solvent. Therefore, more biological friendly solvent, such as ethanol can be more appropriate solvent to be applicable in bio-NMR and MRI. As the proof of concept, successful hyperpolarization on pyridine via SABRE is carried out in ethanol and its enhancement factor is calculated to be more than 150 folds. To investigate more about its possibility of hyperpolarization in different alcohol solvents, methanol and propanol are used for SABRE in the same condition. The overall polarization trend in different external magnetic field is similar but its polarization number is decreased with higher molecular weight solvents (the order from methanol to propanol). This result indicates that the efficiency of SABRE is different from solvent system despite its same functional group and similar properties. Higher para-hydrogen concentration, higher partial pressure of para-hydrogen, and deuterated solvent can increase the hyperpolarization in any solvents. With these series of successful SABRE results, future studies on SABRE in more biofriendly environment, on more various solvent systems, and with more substrates are needed and it will be the firm basis for applying the SABRE system on the future bio-NMR/MRI.