• Title/Summary/Keyword: Partial insulation

Search Result 462, Processing Time 0.029 seconds

The development of the Switchgear Insulation Deterioration Condition Monitoring Equipment by using RFCT (RFCT를 이용한 개폐기 절연열화 상태감시 진단 장치 개발)

  • Choi, Jae-Ok;Kim, Young-Noh;Hwang, Kyung-Jun;Jung, In-Song;Park, Hak-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.404-405
    • /
    • 2008
  • This paper is analyzed that the development of intelligent terminal unit for the switchgear partial discharge diagnosis. It is the core technology for supplying with stable and trust electric as a technology that be economic of the high efficient, the maintain, the confidence and the repair. So the condition diagnosis of the switchgear is necessary by developing inteligent terminal unit.

  • PDF

Detection and Analysis of Partial Discharges in Insulation Oil by a Monopole Antenna (모노폴 안테나에 의한 유중 부분방전의 검출과 분석)

  • Park, Dae-Won;Lee, Jung-Yoon;Kim, Min-Su;Kil, Gyung-Suk;Cheon, Sang-Gyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.10a
    • /
    • pp.69-69
    • /
    • 2011
  • 본 논문에서는 유입변압기의 절연진단을 위한 기초연구로 유중 부분방전에 의해 발생하는 전자파의 검출과 분석에 대하여 기술하였다. 유중 방사전자파 측정에는 공진주파수가 1 GHz인 모노폴 안테나를 제작하였다. 절연유 내부에 침-평판 전극계를 설치하고 0~50 kV까지 고전압을 인가시키면서 유중 부분방전의 발생을 모의하였다. 실험결과, 92.3 pC의 부분방전 발생시 1.28 V의 신호가 검출되었다.

  • PDF

Detection and Analysis of Partial Discharges in Insulation Oil by a Monopole Antenna (마이크로폰을 이용한 코로나 방전의 측정 및 분석)

  • Cho, Hyang-Eun;Park, Dae-Won;Kim, Min-Su;Kil, Gyung-Suk;Cheon, Sang-Gyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.10a
    • /
    • pp.68-68
    • /
    • 2011
  • 본 논문에서는 수배전반의 상태진단을 위하여 코로나 방전에 의해 발생하는 음향신호의 측정 및 분석에 대하여 기술하였다. 침-평판 전극계를 제작하여 코로나 방전을 모의하였으며 음향신호의 측정에는 감도 4 mV/Pa, -3 dB의 주파수 대역이 4 Hz~100 kHz인 마이크로폰을 사용하였다. 코로나 방전에 의한 음향신호의 주파수 분석결과, 주파수 성분은 10 kHz~80 kHz에 분포하였으며 20 kHz~40 kHz의 성분이 가장 우세하게 나타났다.

  • PDF

The Analysis of PD Signal using Neural Network (신경회로망을 이용한 부분방전 신호의 패턴분석)

  • 김종서;박용필;천민우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.567-571
    • /
    • 2004
  • Recently, GIS(Gas Insulated Switchgear) has been recognizing of importance on development of diagnosis technique which is happened problem on confidence for a long time use. Therefore, the measurement and analysis of PD with prior phenomenon of insulation breakdown is used many method of diagnosis for GIS. In this paper, we simulate trouble condition in DS and analysis trouble signal to use electrical and mechanical methods, interpretation of detected signal has analysed with to use ø-q-n pattern and neural network. For this analysis, we have used the induction and AE(acoustic emission) sensors. For the simulation experiment, we make DS for 170 KV GIS and analyze the classification and characteristics of detected signals with the application of neural network algorithm.

The Dielectric loss Properties of Mini-model Superconducting Cable (Mini-model 초전도 케이블의 유전손실 특성)

  • 김영석;곽동순;한철수;김해종;김동욱;김상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.10
    • /
    • pp.946-951
    • /
    • 2003
  • A high-Tc superconducting cable(HTS cable) is expected as an underground power line supplying the electrical power the densely populated city in future. The electrical insulation is very important for develop HTS cable system because it is operated a high voltage and in cryogenic temperature. We manufactured a mini-model cable and measured a tan$\delta$ of cable using schering bridge. The tan$\delta$ of PPLP was lower than that of Tyvek and Kraft at a given temperature, the tan$\delta$ of PPLP was 1.16${\times}$10-3. According to the increase of electric stress the tan$\delta$ increased because partial discharge occurred inside butt gap of mini-model cable. However, the tan$\delta$ decreased by increase of liquid nitrogen pressure. This reason is thought by decrease of part discharge between butt gap by increase of liquid nitrogen pressure.

The Estimation of Outdoor Insulation According to the Concentration of Surface Discharge (표면방전의 집중에 따른 옥외용 설비의 성능평가)

  • Lim, Jang-Seob;Jeong, Seung-Chun;Lee, Jin;No, Jin-Yang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.212-216
    • /
    • 2001
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outdoor insulator because those testing can carry out very short time in Lab-testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outdoor HV machine/system. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab-testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from procelain insulator, used 22.9[KV] distribution, is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in SD concentration according to applied time.

  • PDF

Properties of PD Pulses accompanying with Electrical Tree in LDPE (LDPE에서 전기트리에 수반된 부분방전 펄스의 특성)

  • Park, Y.G.;Bae, M.H.;Kang, S.H.;Lim, K.J.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1507-1509
    • /
    • 1997
  • Property of insulation of electric machine is severely affected by process of electrical tree growing. Partial discharges(PD) have been used to determine degradation of insulations. In this paper, PD quantities detected and analyzed are PD magnitudes, repetition rates, phase angle distribution of PD pulses, and wavelet transformation. The wavelet transformation is an extended method of fourier transformation. The fourier transformation is a powerful tool for signal analysis, but it can't include informations for time. However the wavelet transformation analysis can include on the informations of time and frequencies at the same time. This paper discusses correlation between process of electrical tree growing and characteristics of PD in LDPE specimens.

  • PDF

A Study on the Dielectric Degradation Using Partial Discharge System (부분방전 시스템을 이용한 절연 열화에 관한 연구)

  • 김성홍;이우상;정재용
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.1
    • /
    • pp.1-6
    • /
    • 1998
  • Our studies diagnose insulation degradation using the method of PD system. In analysis method of degradation, we make use of degradation information that analyzed the phase angle - PD pulse amplitude - degradation time( $\Phi$- PDA - t) pattern and phase angle- PD pulse number - degradation time( $\Phi$- PDN - t) pattern using statistical operators such as skewness(S), kurtosis(K). Secondly using statically operator such as the center of gravity (G), the gradient of the discharge distribution(C), we have analyzed for the prediction of life which we can be obtained the time, occurred of many pulse of small discharge amplitude.

  • PDF

On-line Insulation Diagnostic by PD Monitoring Field Practical of UHF Technique for On-line PD Monitoring (UHF 기술을 이용한 온라인 부분방전 모니터링)

  • Oh, Yong;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.176-180
    • /
    • 2008
  • A field-oriented UHF system for on-line PD monitoring of transformers is designed, which has been installed inside the oil tank of transformer in a substation by two ways: on-line installing mode through the oil-valve and pre-installing mode through the man hole/hand hole cover. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

A Study on the Method for Mitigation of Streaming Electrifiction by the Improvement of Flow Condition in the Oil Folw System of Transformer (변압기 절연유의 순환 계통에서의 흐름 조건의 개선에 의한 유동대전현사의 완화 방법에 관한 연구)

  • 권석두;남상천
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.4
    • /
    • pp.594-600
    • /
    • 1994
  • The maximum charge accumulation in transformers caused by streaming electrification is commonly observed on the bottom area of transformer winding(i.e.the oil inlet of transformer winding). It is because turbulent flows occur in this portion of transformers. Consequently, if we are to reduce the maximum charge accumulation of transformers, it is important that we should have a good understanding of the conditions of the occurence of partial turbulent flows in the oil inlet of transformer winding. With this point in mind, a simple flow model was designed in this study in order to simulate oil flow in the insulation ducts of power transformers. As a method for mitigating charge accummulation, attention was given to (a) a flow path design for the improvement of flow conditions, and (b) the charge tendency of the material used this design. The results of this study show that the above method is useful for mitigating charge accumulation.

  • PDF