• Title/Summary/Keyword: Partial extraction with maintaining 0.1N of extraction solution

Search Result 2, Processing Time 0.015 seconds

The controversial points for the assessment of soil contamination related to the change of pH of extraction solution in using partial extraction in standard method in Korea (국내 토양오염 공정시험방법의 용출법 사용시 용출액의 pH의 변화가 토양 오염 평가에 미치는 문제점)

  • 오창환;유연희;이평구;이영엽
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.294-297
    • /
    • 2000
  • Heavy metals are extracted from Chonju stream sediment, roadside soils and sediments along Honam expressway, soils and tailings from mining area using partial ectraction in Standard Method, partial ectraction method with maintaining 0.1N of extraction solution and acid digestion. In samples having buffer capacity against acid, 0.1N of extraction solution can not be maintained and pH of extraction solution increases up to 8.0 when partial extraction in Standard Method is used. The averages and ranges of (heavy metals extracted using partial extraction in standard method, HPE)/(heavy metals extracted using partial extraction method with maintaining 0.1N of extraction solution, HPEM) values are 0.506 and 0.145~1.126 in Cd, 0.534~ and 0.078~0.928 in Zn, 0.461 and 0.041~1.715 in Mn, 0.359 and 0.011~0.874 in Cu, 0.195 and 0.018~1.785 in Cr, 0.710 and 0.003~3.075 in Pb, and 0.088 and 1.73$\times$10$^{-5}$ ~0.303 in Fe. These data indicate that the difference between HPE and HPEM is big in the order of Fe, Cr, Cu, Mn, Cd, Zn and Pb. It is quite possible that the partial extraction method in Standard Method of soil in Korea is not adequate for an assessment of contamination in area where buffer capacity of soil will be decreased or lost after a long term exposure of soils to environmental damage.

  • PDF

The Effects of pH Change in Extraction Solution on the Heavy Metals Extraction from Soil and Controversial Points for Partial Extraction in Korean Standard Method (용출액의 pH 변화가 토양내 중금속 용출에 미치는 영향과 그에 따른 국내 토양 오염 공정시험방법의 문제점)

  • 오창환;유연희;이평구;이영엽
    • Economic and Environmental Geology
    • /
    • v.36 no.3
    • /
    • pp.159-170
    • /
    • 2003
  • Heavy metals are extracted from Chonju stream sediment, roadside soils and sediments along Honam expressway, soils and tailings from mining area using three different methods (partial extraction in Standard Method, partial extraction method with maintaining 0.1 N of extraction solution and Sequential Extraction Method). In samples having buffer capacity against acid, pH 1 (0.1 N HCl) of extraction solution can not be maintained and pH of extraction solution increases up to 8.0 when partial extraction in Standard Method is used. The averages and ranges of HPE(heavy metals extracted using partial extraction in Standard Method)/HPEM(heavy metals extracted using partial extraction method with maintaining 0.1 N of extraction solution) values are 0.479 and 0.145~0.929 for Cd, 0.534 and 0.078~0.928 for Zn, 0.432 and 0.041~0.992 for Mn, 0.359 and 0.011~0.874 for Cu, 0.150 and 0.018~0.530 for Cr, 0.219 and 0.003~0.853 for Pb, and 0.088 and 1.73${\times}$10$^{-5}$~0.303 for Fe. These data indicate that the difference between HPE and HPEM is large in the order of Fe, Cr, Pb, Cu, Mn, Cd and Zn. The amounts of heavy metals extracted decreases in the follow order; Sum III(sum of fraction I, II, III in sequential extraction)>HPEM>Sum III (sum of fraction I and II)>HPE for Zn, Cd and Mn and Sum III>HPEM>HPE for Cr and Fe. In the case Cr, Sum II is lower than HPEM and higher than HPE. In case of Cu, extracted heavy metals is large in the order Sum IV>HPEM>Sum III HPE. HPE/HPEM value decreases with increasing the amount of HCl used for maintaining 0.1 N of extraction solution. For samples with high buffer capacity, HPE/HPEM value in all elements is lower than 0.2. On the other hand, for samples with low buffer capacity, HPE/HPEM value are over 0.2 and many samples have values higher than 0.6 for Zn, Cd Mn and Cu due to the small difference between Sum II and Sum III, and relatively higher mobility. However, for Fe and Cr, HPE/HPEM value is below 0.2 even for samples with low buffer capacity due to their low mobility and big difference between Sum II and Sum III. This study indicates that the partial extraction method in Korean Standard Method of soil is not suitable for an assessment of soil contamination in area where buffer capacity of soil can be decreased or lost because of a long term exposure to environmental damage such as acidic rain.