Application of the Ultrasonic Detection System for the Power Transformer (전력용 변압기 초음파 측정시스템 적용)

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Kim, Jae-Chul
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.12
    • /
    • pp.553-557
    • /
    • 2005
  • This paper describes the application results of an ultrasonic detection system for the power transformer. The ultrasonic detection system with 6 sensors was applied to detect partial discharge in a 154kV transformer with a dangerous levels of $C_{2}H_{2},\;C_{2}H_4$ and $CH_{4}$ gases. The ultrasonic detection tests were carried out 2 times, respectively, to confirm the existence and location of the partial discharge in the transformer. As a result of internal inspection, the arc trace between the pressure ring and core due to the partial discharge was found at the estimated position based on the amplitude and arriving time of the ultrasonic signals. Therefore, it was verified that the ultrasonic detection system is effective as a preventive diagnosis method for the power transformer. Also, the reliability of the ultrasonic detection system in detecting partial discharges in the transformer was also confirmed. It is expected, therefore, that the ultrasonic detection system will have beneficial effects on applications and verifications in detecting partial discharges for the power transformer.

Analysis of Partial Discharge Patterns in the Pumped Storage Generator Stator Windings (양수발전기 고정자 권선에서 부분방전 패턴의 분석)

  • Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1015-1018
    • /
    • 1999
  • Partial discharge patterns were analyzed in the pumped storage generator stator winding. These were measured using partial discharge analyzer(PDA) and digital partial discharge detector(PDD). Slot discharge was discovered in phase A. Discharges at conductor surface were occurred in phase B and in Phase C. Partial discharge patterns from on-line PDA system were compared with those off-line PDD system. The results of two systems are very same in phase A, B and C.

  • PDF

The Electric Fields Characteristics of Partial Discharges in $SF_6$ ($SF_6$ 가스중 부분방전시 전계 특징)

  • 김해준;박경태;박광서;이현동;김충년;이광식
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.145-149
    • /
    • 2001
  • The most of faults in gas insulation of power facilities are caused by partial discharge. Therefore we simulated partial discharge and measured the radiated electromagnetic wave emitted from partial discharge in SF$_{6}$ gas by biconical antenna. This paper describes time delay and electric fields pulse characteristics of radiated electromagnetic waves with distance(1[m], 3[m], 5[m]) between antenna and discharge source.e.

  • PDF

Characteristic Analysis and Origin Positioning of Acoustic Signals Produced by Partial Discharges in Insulation Oil

  • Park, Dae-Won;Jo, Hyang-Eun;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1468-1473
    • /
    • 2013
  • This paper dealt with the propagation characteristics of acoustic signals produced by partial discharges and the positioning of PD origin in insulation oil to develop insulation diagnostic techniques of oil-immerged transformers. Electrode systems such as needle to plane, plane to plane, and particle electrodes were fabricated to simulate some defects of power transformers. In addition, the frequency spectrum and propagation characteristics of acoustic signals with partial discharge (PD) in insulation oil were analyzed. Although there were differences based on the type of defect, the frequency spectra of the acoustic signals measured by wide and narrow band acoustic emission (AE) sensors were distributed in the range of 50 kHz-400 kHz. Therefore, a narrowband AE sensor is suitable for the diagnosis of oil-immersed power transformers. We could find the position of the PD source with an error margin of 10% in the experiments by calculating the position of the PD occurrence using the time difference of arrival measured by five AE sensors.

A Study on the Detection of Acoustic Signal Produced by Partial Discharges in Insulation Oil and its Positioning (부분방전에 의한 음향신호의 검출과 위치추정에 관한 연구)

  • Kil, Gyung-Suk;Park, Dae-Won;Kim, Il-Kwon;Choi, Su-Yeon;Park, Chan-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.907-911
    • /
    • 2007
  • This paper dealt with the frequency spectrum analysis of acoustic signal produced by partial discharge (PD) in insulation oil and the positioning of PD occurrence to apply in diagnosis of oil insulated transformers. Three types of electrode system ; the needle-plane, the plane-plane, and the wire-wire structure were assembled to simulate partial discharges in oil insulated transformers. A low-noise amplifier and a decoupling circuit were designed to detect acoustic signal with high sensitivity The frequency spectrum of the acoustic signal were 50 kHz ${\sim}$ 260 kHz in the needle-plane, 50 kHz ${\sim}$ 250 kHz in the plane-plane, and 45 kHz${\sim}$195 kHz in the wire-wire electrode system. Their peak frequencies were 145 kHz, 130 kHz and 114 kHz, respectively The position of PD occurrence was calculated by the time difference of arrival (TOA) using three acoustic emission (AE) sensors, and we could find the position within the error of 1 % in the experimental apparatus.

The Electric Field Distribution Characteristic Of Outdoor ECT Using the Preventive Diagnostic Sensor (예방진단센서가 내장된 옥외용 ECT의 전계분포특성)

  • Lee, Han-Joo;Cho, Sung-Hoon;Jung, Eui-Hwan;Yoon, Jae-Hoon;Lim, Kee-Joo;Kang, Sung-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.27-27
    • /
    • 2010
  • The exact partial discharge pulse should be measured in order to estimate the discharge source in the solid insulation and diagnose the degree of deterioration. Partial discharges generated in the insulation occur in the internal voids or at the edge of the insulation, have unique characteristics following the type and location. When external voltage is applied, Partial discharges occurred in the restrictively presented voids increase the quantity of electrical charge at the discharge onset voltage. The discharge characteristics have remained constant as space is filled by the impurity such as a compound of gases accompanied with discharge. In this study, How to design the insulation about the problems of the built-in diagnostics in the transformer is discussed by the interpretation of electric field.

  • PDF

A Study on the Design and Fabrication for Partial Discharge Measurement in 22.9kV XLPE Power Cable using Planar Patch Sensor (22.9 kV XLPE 전력케이블에서 부분방전 측정을 위한 Planar Patch Sensor 설계 및 제작 연구)

  • Lim, Kwang-Jin;Yang, Sang-Hyun;Kyawsoe, Lwin;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.265-266
    • /
    • 2008
  • The objective of this paper is to effectively detect partial discharges in XLPE power cables. In this field, we have been usually applied several sensors for such partial discharges. This study used a type of beyond compare antenna based on the influence of background noises. Also, we designed a new structure that is able to easily apply in the adhesion of planar patch types for XLPE power cables in measurement sensitiveness elevation. A high frequency simulation tool (CST-MWS) was applied to the antenna used in this study, and it was used to evaluate certain characteristics. We fabricated an antenna using the simulation data obtained from a specific test. After checking the sensitivity of this Planar Patch Sensor in the Lab, it was tested in an actual site. This paper analyzed the data as a part of time and frequency domain using an oscilloscope and spectrum analyzer, respectively.

  • PDF

A Study on the Design and Fabrication for Partial Discharge Measurment in 22.9kV Underground Power Cable using Planar Loop Sensor (22.9kV급 지중전력케이블의 부분방전 측정을 위한 평면루프센서 설계 및 제작 연구)

  • Shin, Dong-Hoon;Lim, Kwang-Jin;Lwin, Kyawsoe;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.210-211
    • /
    • 2007
  • The objective of this paper is to effectively detect partial discharges in underground power cables. In this field, we have been usually applied several sensors for such partial discharges. This study used a type of beyond compare antenna based on the influence of background noises. Also, we designed a new structure that is able to easily apply in the adhesion of planar loop types for underground power cables in measurement sensitiveness elevation. A high frequency simulation tool (CST-MWS) was applied to the antenna used in this study, and it was used to evaluate certain characteristics. We fabricated an antenna using the simulation data obtained from a specific test. After checking the sensitivity of this Planar Loop Sensor in the Lab, it was tested in an actual site. This paper analyzed the data as a part of time and frequency domain using an oscilloscope and spectrum analyzer, respectively.

  • PDF

Measurement of Electromagnetic Wave Generated by Partial Discharges in an Insulation Oil (유중 부분방전에 의한 방사전자파의 측정)

  • Park, Dae-Won;Lee, Jung-Yoon;Cho, Hyang-Eun;Kim, Min-Su;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1453-1458
    • /
    • 2011
  • This paper dealt with the measurement and analysis of electromagnetic waves generated by partial discharges in insulation oil to develop insulation diagnostic techniques for power transformer. Two types of narrow-band monopole antennas with the resonant frequency of 500 MHz and 1 GHz were designed and fabricated. We simulated defects which consist of a needle electrode with curvature radius of 10 ${\mu}m$ and a plane electrode with diameter of 60 mm in insulation oil. From the experiment, the maximum output voltage of the fabricated antennas was measured; 620 $mV_{max}$ for 500 MHz resonant frequency and 920 $mV_{max}$ for 1 GHz resonant frequency.

  • PDF

The Analysis of Partial Discharges Pattern using Discrete Wavelet Transform (이산 웨이브렛변환에 의한 부분방전패턴 분석)

  • 이현동;김충년;지승욱;박광서;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.183-187
    • /
    • 2000
  • This paper deals with multiresolution analysis of wavelet transform for partial discharge(PD), both corona and surface discharge. Multiresolution analysis was used for performing discrete wavelet transform. PD signals was decomposed into "approximation" and "detail" components until 4 levels by using discrete wavelet analysis. In this paper, daubechies family is adopted for the research of the characteristics of PD signals. The results show that in corona discharge the segment 7, 8, 9, 10, 11 values of defined variable is increased with discharge process, so phase distribution is characterized by 210~330 ranges. In case surface discharge in expoxy insulator inserted, defined variable values is fairly symmetric discharge pattern because coupled both corona and dielectric bounded discharges. We can confirmly discriminate the type PD source. the type PD source.

  • PDF