Comparison of Partial Discharge Characteristics in SF6 Gas Under AC and DC

  • Jo, Hyang-Eun;Wang, Guoming;Kim, Sun-Jae;Kil, Gyung-Suk
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.6
    • /
    • pp.323-327
    • /
    • 2015
  • In this paper, parameters related with partial discharge (PD) were analyzed in SF6 gas under AC and DC voltages. Three electrode systems (protrusion on conductor, protrusion on enclosure, and free particle) were fabricated to simulate PD defects in a gas-insulated switchgear (GIS). All electrode systems were filled with SF6 gas at 0.5 MPa. PD pulses were detected using an oscilloscope and a data acquisition (DAQ) based on IEC 60270. To analyze the PD characteristics under AC and DC voltages, parameters such as discharge inception voltage (DIV), discharge extinction voltage (DEV), pulse magnitude, repetition rate, and T-F map were compared. From the experimental results, PD was revealed to have different characteristics under AC and DC, and these results may be useful for diagnosis of power facilities operated under HVDC.

Electrical Characteristics of Insulation Paper for Distribution Transformers (배전변압기용 절연지의 전기적 특성)

  • Jung, J.W.;Song, I.K.;Lee, B.S.;Han, J.H.;Kweon, D.J.;Kim, C.Y.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.1-5
    • /
    • 2001
  • This paper describes the electrical characteristics of Nomex paper employed as an insulating material of distribution transformers. The relative permittivities(dielectric constants) and $tan{\delta}$(dielectric dissipation factors) were measured as a dielectric characteristic and the partial discharge inception voltages(PDIVs) and breakdown voltages were also measured as an electrical strength characteristic of Nomex paper. As a result, the permittivity and $tan{\delta}$ of Nomex paper showed temperature and frequency dependency. Especially, the permittivity of 0.18mm Nomex paper was 2.4 according to the ASTM condition. And the PDIVs and breakdown voltages were, almost linearly increased with the thickness of Nomex paper and its electrical strength was better than conventional kraft paper.

  • PDF

Analysis on the Dielectric Characteristics of Gaseous Nitrogen for Developing Eco-friendly High Voltage Apparatuses (친환경 고전압 전력기기 개발을 위한 GN2의 절연특성 분석)

  • Bang, Seungmin;Lee, Onyou;Kim, Junil;Kang, Jong O;Lee, Hongseok;Ko, Taekuk;Kang, Hyoungku
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.356-360
    • /
    • 2014
  • The environmental pollution caused by green-house gases such as $SF_2$ has been becoming the main issue of industrial society. As a part of these efforts, 180 countries signed the Kyoto Protocol in 1997 to cut back on their green-house gas emissions [1]. Therefore, a study on the dielectric characteristics of the $GN_2$ is important for designing a eco-friendly high voltage apparatuses. In this paper, to develop an electrically reliable, stable, and eco-friendly high voltage apparatus, the breakdown voltage and partial discharge inception voltage characteristics in $GN_2$ considering utilization factors are studied for the establishment of insulation design criteria of an high voltage apparatus. Dielectric experiments are performed by using several kinds of sphere-plane electrode systems made of stainless steel. Also, the dielectric characteristics of the $GN_2$ are analyzed by using a Finite Elements Method (FEM) according to various field utilization factors. The results are expected to be applicable to designing the high voltage apparatuses using $GN_2$ as an insulation gas.

PD Occurrence Characteristics according to Voltage and Time in Solid Insulator

  • Park, Sung-Hee;Shin, Dal-Woo;Lim, Kee-Joe;Park, Young-Guk;Kang, Sung-Hwa
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.1
    • /
    • pp.10-14
    • /
    • 2003
  • The occurrence of partial discharge (PD) in solid dielectrics is very harmful because it leads to the deterioration of insulation by electrical, chemical, and thermal reactions as a combined action of the discharged ions bombarding the surface and by the action of chemical compounds that are formed by the discharge. Consequently, if any defects are present in the solid insulation system, performance decreases until the system breaks down. Therefore, removing or suppressing the defect is very important. Voids are a typical defect in the solid insulation system and are very harmful because they deteriorate insulation. As a basic step, studying the properties of PD in voids is important because an accurate knowledge of these properties is required to estimate the deterioration of voids. In this paper, the correlation between the size of voids and internal PD is discussed as a function of the time of the applied voltage and its magnitude. Magnitude, repetition rate, average discharge power, and average discharge current of PD in specimens with large voids were found to be larger than the others in this experiment. The smaller specimens had voids when the magnitude and number of PDs were reduced.

Cavity and Interface effect of PI-Film on Charge Accumulation and PD Activity under Bipolar Pulse Voltage

  • Akram, Shakeel;Wu, Guangning;Gao, GuoQiang;Liu, Yang
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2089-2098
    • /
    • 2015
  • With the continuous development in insulation of electrical equipment design, the reliability of the system has been enhanced. However, in the manufacturing process and during operation under continues stresses introduce local defects, such as voids between interfaces that can responsible to occurrence of partial discharge (PD), electric field distortion and accumulation of charges. These defects may lead to localize corrosion and material degradation of insulation system, and a serious threat to the equipment. A model of three layers of PI film with air gap is presented to understand the influence of interface and voids on exploitation conditions such as strong electrical field, PD activity and charge movement. The analytical analysis, and experimental results are good agreement and show that the lose contact between interfaces accumulate more residual charges and in consequences increase the electric field intensity and accelerates internal discharges. These residual charges are trapped charges, injected by the electrodes has often same polarity, so the electric field in cavities increases significantly and thus partial discharge inception voltage (PDIV) decreases. Contrary, number of PD discharge quantity increases due to interface. Interfacial polarization effect has opposite impact on electric field and PDIV as compare to void.

Electrical Characteristics of Polymer Insulators with Field Aging (현장열화에 따른 폴리미애자의 전기적 특성)

  • 한재홍;이병성;김찬영;한용희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.522-525
    • /
    • 1999
  • The electrical characteristics of 3 year field-aged polymer insulators which dismounted from five regions were investigated. There was a little difference in PD inception voltage depending on the manufacturers and the regions. The results between PD and SD showed a close relation. There were no significant changes in electrical properties. So, it can be considered that the field-aged insulators are sound for the present.

  • PDF

Evaluation of Winding Insulation of IGBT PWM Inverter-Fed Low-Voltage Induction Motors

  • Park Doh-Young;Hwang Don-Ha;Kim Yong-Joo;Kang Do-Hyun;Lee Young-Hoon;Kim Dong-Hee;Lee In-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.470-474
    • /
    • 2001
  • IGBT inverters have switching rise times of 0.2-2 $\mu$ sec, and have been believed to cause insulation stresses and premature motor failures. Inverter driven induction motors with high speed switching and advanced PWM techniques are widely used for variable speed applications. Recently, the insulation failures of stator winding have attracted many concerns due to high dv/dt of IGBT PWM inverter output. In this paper, the detailed insulation test results of 19 low-voltage induction motors are presented. Different types of insulation techniques are applied to 19 motors. The insulation characteristics are analyzed with partial discharge, discharge inception voltage, and dissipation factor tests. Also, breakdown tests by high voltage pulses are performed, and the corresponding breakdown voltages are obtained.

  • PDF

Experimental Investigation on Dielectric and Thermal Characteristics of Nanosized Alumina Filler Added Polyimide Enamel

  • Sugumaran, C. Pugazhendhi
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.978-983
    • /
    • 2014
  • The polymer nano composite possess good priority recently for engineering applications. Especially the electrical insulating materials attract the high performance of nano composites. In this work the ballmill synthesiation process of nano sized Alumina ($Al_2O_3$), the preparation of new nano composite material with an content of enamel and synthesized Alumina as 1wt%, 3wt% and 5wt%. Experimental investigation has been carried out for the prepared nano composites materials with respect to dielectric parameter measurements such as dielectric loss (tan ${\delta}$), dielectric constant (${\varepsilon}$), dielectric strength under various temperature. The partial discharge level also measured for all the samples and the PD inception voltage is also observed and compared. Weight loss of the material has been analyzed through TGA. It has been experimentally proved that 3wt% of Alumina nano filler added enamel has significant improvement in the dielectric and thermal properties.

Analysis of Partial Discharge Characteristics in SF6 Gas Insulation (SF6 가스절연에서 부분방전의 특성분석)

  • Kim, Sun-Jae;Wang, Guoming;Park, Seo-Jun;Kil, Gyung-Suk;An, Chang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.7
    • /
    • pp.429-434
    • /
    • 2016
  • This paper deals with the characteristics of partial discharge (PD) for the purpose of a condition based maintenance (CBM) of gas insulated switchgears (GIS) in power equipment. Four types of electrode systems such as a protrusion on enclosure (POE), a particle on spacer (POS), a free particle (FP) and a Floating were designed and fabricated. PD pulses were measured using UHF sensor with a frequency range of 300 MHz~1.4 GHz and a DAQ with a sampling rate of 250 MS/s. Discharge inception voltage (DIV), discharge extinction voltage (DEV), and phase resolved partial discharge (PRPD) were analyzed depending on electrode systems. The average DIV in the POS was 28.8 kV. It was about 1.7 times higher than that in the FP, which was the lowest value of 17.2 kV. The FP shuffled and jumped at the applied voltage of 23.5 kV. Over 95% of PD pulses in the POE were generated in the negative polarity ($181^{\circ}{\sim}360^{\circ}$) of applied voltage. The results showed the phase (${\Phi}$)-magnitude (dBm) of PD pulses by UHF sensor, a cluster was formed separately depending on electrode systems.

Design and Fabrication of a Partial Discharge Analyzer (부분방전 분석장치의 설계 및 제작)

  • Song, Jae-Yong;Moon, Seung-Bo;Cha, Myung-Soo;Kil, Gyung-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1517-1518
    • /
    • 2006
  • This paper describes the design and fabrication of a partial discharge(PD) analyzer to evaluate insulation performance for low-voltage electrical and electronic devices. The analyzer consists of an adjustable AC power supply, a coupling network, an amplifier, a shielding encloser, a sample-hold (S/H) circuit and a data acquisition (DAQ) board. The analyzer holds the height of PD pulse for $10{\mu}s$ by the S/H circuit, and this makes possible to measure PD pulses having fast rise and short duration by a low speed analog-to-digital (A/D) converter. The data are transmitted to the personal computer through the DAQ board, and the designed analysis program calculate apparent charges, discharge inception and extinction voltages.

  • PDF