• 제목/요약/키워드: Partial discharge extinction

검색결과 19건 처리시간 0.022초

부분 방전에 의한 실리콘 케이블의 열화 특성에 관한 연구 (A Study on Degradation Properties of Silicone Cable due to Partial Discharge)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.34-39
    • /
    • 2015
  • In this study, the characteristics of partial discharge was measured for the four core silicone cable (0.6/1.0 kV, $1.0SQ{\times}4C$) with insulated part of 15 cm and conductor of 1cm. The following results have been confirmed as a result of this study. When the first line of cable is connected to the positive electrode and the second, third line of cable is connected to the negative electrode, it found that the inception voltage and extinction voltage decreased with increasing the line of negative electrode, and the partial discharge charge quantity(Q) increases, while the number of discharge occurrence has decreased. The inception voltage and extinction voltage of partial discharge has decreased with increasing the degradation rate in the 33%, 67%, 100%. Also, it confirmed that the partial discharge charge quantity(Q) and the number of discharge occurrence has decreased.

Some Problems of the Partial Discharge Burning Time

  • Kinsht Nikolay V.;Katz Marat A.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권6호
    • /
    • pp.319-323
    • /
    • 2006
  • The problem of the partial discharge (PD) extinction is investigated. The transient process takes place in a small spherical inclusion which is located in the dielectric. Both the losses caused by polarization and ohmic losses as the dielectric parameters are taken into account. From the inclusion standpoint the dielectric is considered as an active two-pole element (equivalent generator) and inclusion represents by own current-voltage curve. PD extinction voltage was shown to depend on the polarization loss tangent.

부분방전에 의한 주계전기의 절연성능 평가 (Insulation Performance Estimation of Main Relays by Partial Discharges)

  • 길경석;김일권;박대원;송재용;이강원;조은제
    • 한국철도학회논문집
    • /
    • 제10권4호
    • /
    • pp.388-392
    • /
    • 2007
  • A new dielectric test on main relays of electric traction vehicles, the partial discharge(PD) test, is proposed. The PD test will not affect the insulation performance of specimen during the test and provide much more detailed information on insulation, the types of defects, and so on. Insulation performance of relays is estimated by discharge inception voltage(DIV), discharge extinction voltage (DEV), and apparent charge as a function of test voltage and time. Three main relays of different manufacturing date were estimated by applying AC voltage with three patterns in ranges of $0{\sim}1,200[V]$. From the results, we could estimate insulation state and which types of defects exist in them.

NaCl에 의한 PVC 케이블의 부분방전 열화 특성에 관한 연구 (A Study on Partial Discharge Degradation Properties of PVC Cable due to NaCl)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제28권10호
    • /
    • pp.636-641
    • /
    • 2015
  • In this study, the partial discharge degradation properties for 2-core PVC cable($2cores{\times}1.5mm^2$ cross section, length of 10 cm, 20 cm, 30 cm) following immersion with the salt water that the 2%, 4%, 8% of NaCl is dissolved in 100 g of distilled water for 48 and 96 hours has been measured. The results of this study are as follows. When the degradation time in salt water of 2% NaCl is 48 hours, it found that the number of partial discharge increased as about 40 pps, 50 pps, 90 pps with increasing the length of cable to 10 cm, 20 cm, 30 cm. In case the concentration and degradation time is same, the inception and extinction voltage decreased with increasing the length of cable. When the degradation time in salt water is 96 hours and the length of cable is 20 cm, it found that the number of partial discharge decreased as 3,000 pps, 500 pps, 100 pps with increasing the concentration of NaCl to 2%, 4%, 8%.

실리콘 고무의 부분방전 특성에 관한 연구 (A Study on Properties of Partial Discharge in Silicone Rubber)

  • 이성일;권영천
    • 한국전기전자재료학회논문지
    • /
    • 제24권11호
    • /
    • pp.890-894
    • /
    • 2011
  • In this thesis, the silicone filler with a sample size of 0~75 phr and void size of 2~4.5 mm is prepared in order to diagnose the defect of void which exists in widely used insulation material, silicone rubber. In this silicone rubber sample, electrodes are connected and whilst the voltage changes, applied voltage 7 kV~9 kV is increased constantly over time and discharge quantity, discharge frequency and applied voltage (T-QNV) were measured. The discharge quantity of the applied voltage (VQ) is measured to estimate inception voltage and extinction voltage. In addition, under the condition of maintaining constant applied voltage, discharge quantity and discharge frequency (QN) are measured, and its characteristics are analyzed.

SF6, g3 및 Dry Air 절연에서 PD 특성 비교 분석 (Comparative Analysis of PD Characteristics Under SF6, g3 and Dry Air Insulation)

  • 신한신;김남훈;김성욱;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제33권6호
    • /
    • pp.490-494
    • /
    • 2020
  • Sulphur hexafluoride (SF6) is mostly used as a current-insulating medium in gas-insulated switchgears (GIS), owing to its excellent dielectric strength and arc-extinguishing performance. The global warming potential (GWP) of SF6, however, is 23,900 times that of CO2, and its life time in the atmosphere is 3,200 years. For these reasons, new eco-friendly gases to replace SF6 are required. In this study, the partial discharge (PD) characteristics of green gas for grid (g3) and dry air (N2/O2) were analyzed to compare with those of SF6. A PD electrode system was designed to simulate the protrusion defect in GISs and fabricated for experimentation. To compare the PD characteristics of each gas, the discharge inception voltage (DIV), discharge extinction voltage (DEV), discharge magnitude, discharge pulse number, and phase pattern were analyzed. Results from this study are expected to provide fundamental materials for the design of eco-friendly GISs.

열열화된 PVC 케이블의 부분방전 진단 (Partial Discharge Diagnosis of Thermal Degradated PVC Cable)

  • 송기태;이성일
    • 한국전기전자재료학회논문지
    • /
    • 제24권3호
    • /
    • pp.208-214
    • /
    • 2011
  • In this thesis, the partial discharge according to applied voltage and variations of cross-sectional area and length of the conductor related to general condition for using cable was measured in order to study degradation diagnosis for 2-Core cable of the PVC insulator used in industrial fields for other safety installations. Also the thermal degradation conditions under various installation circumstances of cables were studied by assuming degradation conditions with each different degradation rate (50%, 67%, 100%) such as variation in degradated temperature, thermal exposure time, normal state, partially degradated state and overall degradated state for thermal degradation diagnosis. The quantity of electric discharge (V-Q) according to applied voltage was measured for measurement of inception voltage and extinction voltage. The quantity of electric discharge and the number of electric discharge (Q-N) were measured with applied voltage kept constantly. In addition, pictures were taken using SEM (scanning electron microscope) to compare the surface of external insulator to degradated state of internal insulator according to thermal degradation temperature and also compare the surface of external insulator to degradated surface state of internal insulator according exposure time of cables to thermal stress.

Comparison of Partial Discharge Characteristics in SF6 Gas Under AC and DC

  • Jo, Hyang-Eun;Wang, Guoming;Kim, Sun-Jae;Kil, Gyung-Suk
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권6호
    • /
    • pp.323-327
    • /
    • 2015
  • In this paper, parameters related with partial discharge (PD) were analyzed in SF6 gas under AC and DC voltages. Three electrode systems (protrusion on conductor, protrusion on enclosure, and free particle) were fabricated to simulate PD defects in a gas-insulated switchgear (GIS). All electrode systems were filled with SF6 gas at 0.5 MPa. PD pulses were detected using an oscilloscope and a data acquisition (DAQ) based on IEC 60270. To analyze the PD characteristics under AC and DC voltages, parameters such as discharge inception voltage (DIV), discharge extinction voltage (DEV), pulse magnitude, repetition rate, and T-F map were compared. From the experimental results, PD was revealed to have different characteristics under AC and DC, and these results may be useful for diagnosis of power facilities operated under HVDC.

부분방전 분석장치의 설계 및 제작 (Design and Fabrication of a Partial Discharge Analyzer)

  • 송재용;문승보;차명수;길경석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1517-1518
    • /
    • 2006
  • This paper describes the design and fabrication of a partial discharge(PD) analyzer to evaluate insulation performance for low-voltage electrical and electronic devices. The analyzer consists of an adjustable AC power supply, a coupling network, an amplifier, a shielding encloser, a sample-hold (S/H) circuit and a data acquisition (DAQ) board. The analyzer holds the height of PD pulse for $10{\mu}s$ by the S/H circuit, and this makes possible to measure PD pulses having fast rise and short duration by a low speed analog-to-digital (A/D) converter. The data are transmitted to the personal computer through the DAQ board, and the designed analysis program calculate apparent charges, discharge inception and extinction voltages.

  • PDF

XLPE 케이블 절연체에서의 가지형 전기트리 성장에 따른 부분방전 위상 특성 연구 (A Study on the Partial Discharge Phase Properties with Branch Type Eleotrical Tree Growth in XLPE Cable Insulation)

  • 강동식;선종호;김위영;이홍식;박정후
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권5호
    • /
    • pp.213-221
    • /
    • 2002
  • In order to improve the reliability of XLPE cables, it is necessary to find the useful diagnostic parameter according to long term aging. This paper described the change of partial discharge(PD) phase Properties of XLPE cable insulation with branch type electrical tree degradation. for long term aging. To understand the PD Properties with $\phi$ -q-n distributed shape of XLPE insulation, specimens were prepared by 22.9㎸ distribution cable and made in a type of block(16${\times}$16${\times}$3[mm]). Ogura needles having tip radius of l0${\mu}{\textrm}{m}$ were inserted into each block pieces. The measuring system was consisted of PD detector, digitizer for digital conversion, VXI system for signal processing. The PD properties of the specimens were measured from initiation of tree to breakdown and their characteristics were analyzed. We analyzed the relationship between electrical properties(PD Quantity, PD initiation angle, PD extinction angle, PD occurrence angle : (PD extinction angle - PD initiation angle)) and the normalized aging rate. We found PD parameter, PD initiation angle and occurrence angle, which are a useful diagnostic parameter in estimating the branch type electrical tree for XLPE insulation condition.