• 제목/요약/키워드: Partial defect

검색결과 446건 처리시간 0.025초

관상정맥동 결손과 좌상대정맥의 좌심방환류에 대한 수술및 수술방법의 연구;부분형 방실관결손과 공통심방이 동반된 1례 (Unroofed Coronary Sinus and its Surgery; Associated with Partial Atrioventricular Canal Defect and Common Atrium)

  • 이상호
    • Journal of Chest Surgery
    • /
    • 제26권4호
    • /
    • pp.312-315
    • /
    • 1993
  • The malformation consisted of persistent left SVC terminating in left atrium, absence of coronary sinus, and atrial septal defect is considered as a developmental complex anomaly. We observed such a case associated with partial atrioventricular canal defect and common atrium. We operated it by intraatrial roofing [tunneling] along its course of the posterior wall of the left atrium using bovine pericardial patch, which was designed to contain some of thebesian veins, thereby, left superior vena caval and some coronary venous blood would be drained into venous side. Associated lesions were also corrected.

  • PDF

우심증에서 부분 폐정맥 이상환류를 동반한 심방중격결손 -1례 보고- (Partial Anomalous Pulmonary Venous Drainage Associated with Septal Defect in Dextrocardia)

  • 장명;장병철;조범구;홍승록
    • Journal of Chest Surgery
    • /
    • 제12권1호
    • /
    • pp.30-32
    • /
    • 1979
  • Partial anomalous pulmonary drainage is frequently accompanied by an atrial septal defect. The anomaly is entirely compatible with life and the clinical findings are dependent primarily on the proportion of the pulmonary venous return to the right atrium. The anomaly is frequently missed even with complete diagnostic study. In this report we are presenting a case of anomalous pulmonary venous drainage combined with atrial septal defect and dextrocardia and the treatment of this condition.

  • PDF

부분 폐정맥 환류이상과 심방중격 결손증을 동반한 삼중방심의 치험 1례 (Cor Triatriatum Associated with Atrial Septal Defect and Partial Anomalous Pulmonary Venous Return: Report of A Case)

  • 이철주
    • Journal of Chest Surgery
    • /
    • 제18권3호
    • /
    • pp.440-445
    • /
    • 1985
  • Cor triatriatum is a variant of abnormal connection between the pulmonary vein and true left atrium, which is separated from accessory left atrium receiving pulmonary venous blood flow by fibromuscular diaphragm. Usually it is diagnosed after operation because difficulty in visualization of the diaphragm by conventional diagnostic tools. We experienced a rare entity of congenital heart disease diagnosed as car triatriatum with atrial septal defect and partial anomalous pulmonary venous return after completing operation, which was diagnosed as ASD with PAPVR preoperatively. Anomalous right pulmonary venous opening was located at right atrium, secundum type defect of atrial septum was present, and dual chambered left atrium without connection was also seen. Excision of the diaphragm and wide patch repair of ASD including right pulmonary vein were performed with good postoperative results. Herewith, we report this case with review of literatures.

  • PDF

심방중격결손에 동반한 좌상폐정맥연결이상 - 치험 1례 - (An Anomalous Left Upper Pulmonary Venous Connection Associated with ADS(Atrial Septal Defect))

  • 임용택;신용철;정승혁;김병렬
    • Journal of Chest Surgery
    • /
    • 제32권10호
    • /
    • pp.939-942
    • /
    • 1999
  • Partial anomalous pulmonary venous connection is frequently found in any ASD(atrial septal defect) patients. These patients are usually symptomatic, therefore, easily diagnosed as just simple ASD. We experienced a case of a 37-year-old female patient with ASD in which the left upper pulmonary vein was connected to SVC by the left inominate vein. The patient was diagnosed as simple ASD previously. During cardiac catheterization, we found a meaningful oxygen saturation step up between the SVC and its upper portion. Angiogram confirmed PAPVC. The surgical correction of anastomosis of PAPVC with left atrial appendage and direct closure of ASD were done. The patient was discharged 15 days later.

  • PDF

Features Extraction and Mechanism Analysis of Partial Discharge Development under Protrusion Defect

  • Dong, Yu-Lin;Tang, Ju;Zeng, Fu-Ping;Liu, Min
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.344-354
    • /
    • 2015
  • In order to study the development of partial discharge (PD) under typical protrusion defects in gas-insulated switchgear, we applied step voltages on the defect and obtained the ${\varphi}-u$ and ${\varphi}-n$ spectrograms of ultra-high frequency (UHF) PD signals in various PD stages. Furthermore, we extracted seven kinds of features to characterize the degree of deterioration of insulation and analyzed their values, variation trends, and change rates. These characteristics were inconsistent with the development of PD. Hence, the differences of these features could describe the severity of PD. In addition, these characteristics could provide integrated characteristics regarding PD development and improve the reliability of PD severity assessment because these characteristics were extracted from different angles. To explain the variation laws of these seven kinds of parameters, we analyzed the relevant physical mechanism by considering the microphysical process of PD formation and development as well as the distortion effect generated by the space charges on the initial field. The relevant physical mechanism effectively allocated PD severity among these features for assessment, and the effectiveness and reliability of using these features to assess PD severity were proved by testing a large number of PD samples.

Inhomogeneous bonding state modeling for vibration analysis of explosive clad pipe

  • Cao, Jianbin;Zhang, Zhousuo;Guo, Yanfei;Gong, Teng
    • Steel and Composite Structures
    • /
    • 제31권3호
    • /
    • pp.233-242
    • /
    • 2019
  • Early detection of damage bonding state such as insufficient bonding strength and interface partial contact defect for the explosive clad pipe is crucial in order to avoid sudden failure and even catastrophic accidents. A generalized and efficient model of the explosive clad pipe can reveal the relationship between bonding state and vibration characteristics, and provide foundations and priory knowledge for bonding state detection by signal processing technique. In this paper, the slender explosive clad pipe is regarded as two parallel elastic beams continuously joined by an elastic layer, and the elastic layer is capable to describe the non-uniform bonding state. By taking the characteristic beam modal functions as the admissible functions, the Rayleigh-Ritz method is employed to derive the dynamic model which enables one to consider inhomogeneous system and any boundary conditions. Then, the proposed model is validated by both numerical results and experiment. Parametric studies are carried out to investigate the effects of bonding strength and the length of partial contact defect on the natural frequency and forced response of the explosive clad pipe. A potential method for identifying the bonding quality of the explosive clad pipe is also discussed in this paper.

Electrical Conduction in $SrZr_{0.95}Y_{0.05}O_{2.975}$ Ceramics

  • Baek, Hyun-Deok;Noh, Jin-Hyo
    • The Korean Journal of Ceramics
    • /
    • 제5권3호
    • /
    • pp.288-295
    • /
    • 1999
  • Partial conductivities contributed by electron holes, oxygen ions, and protons were caluclated in $SrZr_{0.95}Y_{0.05}O_{2.975}$, using the reported formulae derived from the defect chemistry of HTPCs. Required parameters were obtained from the graphical analysis of total conductivity variation against partial pressure of water vapor and oxygen. Predicted overall conductivities showed a reasonable agreement with experimental measurements. The conductivity of the material showed a linear increase with square root of the water vapor pressure. This increase was due to proton conduction in an almost pure ionic conductivity. The calculation of partial conductivities at $800^{\circ}C$ resulted in an almost pure ionic conductivity at $P_{02}=10^{-10}$ atm and a predominant hole conductivity at $P_{02}=10^{-10}$ atm. Pure proton conduction was not expected at this temperature, contrary to the earlier reports. Discussions were made in relation with reported thermodynamic data and defect structure of the material. It was shown that from the total conductivity dependence on water vapor pressure, the pure ionic conductivity at low oxygen partial pressures could be separated into protonic and oxygen ionic conductivity in $ZrO_2$-based HTPCs.

  • PDF

전력케이블에서 교류전압과 진동파 전압을 이용한 부분방전 측정 (Partial Discharge Detection for the Power Cables using AC and Oscillating wave Voltage)

  • 김정태;김남준;이전선;구자윤
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권4호
    • /
    • pp.247-252
    • /
    • 1999
  • In this paper, in order to investigate availability of the OW-PD measurement method which has been proposed as an alternative of AC-PD measurement method to an after laying test and/or diagnosis for the power cable system, partial discharges owing to the needle-type defect integrated into the cable have been measured using AC and OW(Oscillating Wave) voltages. In the AC-PD measurement, the magnitude, phase and pulse number of partial discharges have been changed with the duration of voltage application, which can be analyzed through the relation with the process of the electrical tree initiation and propagation. In addition, the characteristics of partial discharges using OW voltage are appeared to be similar to those in case of AC-PD measurement and to be different with the shapes of electrical tree. From these results, it is concluded that the OW-PD measurement method is available to the tests for the cable system.

  • PDF

부분 탈상피화 둔부 전위 피판을 이용한 천미골 털둥지굴의 수술적 치료 (Surgical Treatment of Sacrococcygeal Pilonidal Sinus with the Partial Deepithelized Gluteal Transposition Flap)

  • 남두현;신호성;박은수;김용배
    • Archives of Plastic Surgery
    • /
    • 제35권4호
    • /
    • pp.446-449
    • /
    • 2008
  • Purpose: Pilonidal sinus is a frequent disease that occurs mostly in hairy young men, defined as chronic inflammation and infection of the postsacral sinuses. Wide excision of the affected area is the treatment of choice. Many techniques have been described to cover the defect. However none appears to be the ideal procedure to prevent infection, recurrence, and delayed wound healing. We present the results of an alternative technique that we performed by using partial deepithelized gluteal transposition flap for reconstruction of the defect following wide excision. Methods: From October 2004 to September 2007, we performed the partial deepithelized gluteal transposition flap method on 6 patients. We modified the transposition flap techniques by deepithelialising the medial parts of the flap and burying them under the opposing edge of the flap. The results were compared with previous studies and evaluated regarding duration of surgery, size of defect, hospitalization periods, and complications. Results: All the flaps were healed well with no partial or complete loss of the flap. Hospitalization and immobilization periods were acceptably shortened. Recurrence was not seen. The aesthetic outcome was also satisfactory and all patients were satisfied with the results. Conclusion: The main advantage of our techniques is using healthy tissues to obliterate the dead space, to provide an extra-cushion, and to prevent deep dehiscence. We believe that the partial deepithelized gluteal transposition flap is a good alternative method for treatment of pilonidal sinus.

Defect Chemistry of BaTiO_3$ Codoped with Mn and Nb

  • Han, Young-Ho;Shin, Dong-Jin
    • The Korean Journal of Ceramics
    • /
    • 제4권2호
    • /
    • pp.68-71
    • /
    • 1998
  • The effect of Mn and Nb additions on the electrical properties of BaTiO$_3$ has been studied by means of equilibrium electrical conductivity as a function of temperature, oxygen partial pressure(Po$_2$) and composition. If the manganese ion is added to the normal Ti site, i.e. BaTi$_{1-x}Mn_xO_{\delta-6}$, the equilibrium conductivity shows strong evidence of acceptor-doped behavior. The conductivity minimum, corresponding to the transition from oxygen excess, p-type behavior to oxygen deficient, n-type behavior with decreasing Po$_2$, is displaced to lower Po$_2$ and is broadened and flattened. The partial replacement of Mn ion with Nb decreases the acceptor-doped effect and the total replacement exhibits a typical donor-doped behavior. It was confirmed that unlike undoped or other acceptor-doped behavior. It was confirmed that unlike undoped or other acceptor-doped samples, for the p-type region, the electrical conductivity follows the 1/6th power dependence of oxygen partial pressure.

  • PDF