• Title/Summary/Keyword: Partial defect

Search Result 446, Processing Time 0.03 seconds

Partial Anomalous Pulmonary Venous Return - Report of 1 case - (부분 폐정맥환류이상 1례 보고)

  • 조대윤
    • Journal of Chest Surgery
    • /
    • v.21 no.1
    • /
    • pp.148-151
    • /
    • 1988
  • We experienced 2 years and 5 months old male patient with partial anomalous pulmonary venous return of the left lung into the coronary sinus without atrial septal defect. After incising the atrial septum and the wall between the left atrium and the coronary sinus, we made the roof of the coronary sinus and closed the artificial atrial septal defect, with using patch, then we could change the direction of the blood flow from the coronary sinus into the left atrium. The patient was discharged on the 13th postoperative day after uneventful postoperative course.

  • PDF

A Study on the Partial Discharge Location Method using 2 Sensors (2개 센서를 이용한 부분방전 위치추정 기법 연구)

  • Kim, Jeong-Tae;Kim, Dong-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.251-256
    • /
    • 2012
  • This study deals with the location of partial discharges(PDs) for power cables and GIS using 2 PD sensors and long coaxial signal cables. Throughout the experiments by use of simulated PD pulses and corona discharges in the power cable system, it is found out that the impedance matching between the coaxial signal cable and the measuring equipment should be done for good S/N ratio and the on-site measurement using more than 100m-long coaxial signal cable is possible. In addition, new PD location algorithm with the polarities of PD pulses and the arrival time difference between two pulses was proposed and was proved through the partial discharge experiments for the cable joint defect and artificial void defect.

Partial Discharge Characteristics of void in Nano-composites Materials (나노복합재료의 보이드 부분방전 특성)

  • Jeong, I.B.;Choi, H.M.;Kim, W.J.;Cho, K.S.;Choi, K.J.;Kim, J.H.;Yeon, K.H.;Hong, J.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.397-398
    • /
    • 2009
  • In oder to investigate of partial discharge of nano-composites materials, we have studied partial discharge appling voltage from 5 to 30 [kV] to make an artificial defect with the epoxy adding to 0, 0.4, 0.8, and 1.6 [wt%], respectively. The experimental result, we have found that $SiO_2$ of 0.4 (wt%] was superior to others also, it is found that the effect of isolate diagnosis to get the slope for the discharged electric charge distribution.

  • PDF

Signal Characteristics of Ultra-high Frequency Radiation from Partial Discharge in Insulation Oil (절연유에서 부분방전에 의한 극초단파 신호 특성분석)

  • Ju, Hyoung-Jun;Goo, Sun-Geun;Park, Ki-Jun;Han, Ki-Seun;Yoon, Jin-Yul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.56-59
    • /
    • 2008
  • We have designed 4 types(void in insulation paper, protrusion electrode, floating electrode, surface discharge) of partial discharge(PD) defect to simulate typical faults found in oil filled power transformers. Ultra-high frequency(UHF) radiation due to PD was measured using a UHF measuring system and a conventional PD measuring system, simultaneously. Electromagnetic radiation spectra of these defects show UHF radiation up to about 1.5-2 GHz range. The phase resolved partial discharge(PRPD) patterns of UHF radiation from the PD defects were also measured and the pattern reveals distinct feature for each defect types. The UHF measuring could be used to detect PDs in oil filled transformers and analysis of the PRPD pattern should provide useful information on origin of PD signal.

Chracteristics of Partial Discharge Patterns Subjected to Different Defects at the Epoxy/Rubber Interface (에폭시/고무 계면에서의 결함에 따른 부분방전 특성)

  • Kim, Dong-Uk;Kim, Jeong-Nyeon;Baek, Ju-Heum
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.5
    • /
    • pp.199-204
    • /
    • 2002
  • In order to recognize the deterioration of insulation system by partial discharge (PD), the characteristics of PD patterns which are occurring at the interface between epoxy and rubber materials in extra high voltage cable joints, have been investigated. The artificial defects such as voids, metal particles, insulation fiber and water impregnated insulation fiber are planted between the interfaces. A high frequency partial discharge detection system was used for measuring PD signals. An analysis of the PD patterns is focused on the shape of PD pattern, phase, width and time-dependence for each artificial defect. The PD Patterns in each defect show the different behaviors and it is suggested that the precise discrimination of PD patterns could be used for the diagnosis of deterioration in the insulation systems.

Sputtering yield and defect energy level characteristics MgO protective layer according to $O_2$ partial pressure in AC-PDPs

  • Jung, S.J.;Son, C.G.;Song, K.B.;Cho, S.H.;Oh, H.J.;Cho, G.S.;Kang, S.O.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1384-1387
    • /
    • 2007
  • We have investigated the sputtering and secondary electron emission characteristics of MgO protective layer according to the $O_2$ partial pressure. The MgO layer have been deposited by electron beam evaporation method and have varied the $O_2$ partial pressure as 0, $5.2{\times}10^{-5}$, $1.0{\times}10^{-4}$, and $4.1{\times}10^{-4}$ Torr. It has been known that the secondary electron emission coefficient and the number of defect energy levels increased as the $O_2$ partial pressure increases. So we have investigated the property of sputtering yield according to the $O_2$ partial pressure. We have known that the sputtering yield deceases as the $O_2$ partial pressure increases by using the FIB system.

  • PDF

Surgical Repair of Partial Atrioventricular Canal Defect (부분심내막상 결손증의 교정수술치험 3례)

  • Kim, Yeong-Ho;Kim, Gong-Su
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.299-304
    • /
    • 1985
  • The partial A-V canal defect consist of ostium primum type atrial septal defect with a cleft mitral anterior leaflet. The clinical findings depend upon the site and size of the left-to-right shunt, the degree of A-V valvular regurgitation, and the degree of resultant pulmonary artery hypertension. We experienced 3 cases of similar condition. The data were as follow: 1. Chest P-A showed increased pulmonary vascularity and moderate cardiomegaly with left atrial enlargement. 2. E.K.G. showed left axis deviation, left atrial enlargement, and left ventricular hypertrophy. 3. Right heart catheterization showed significant 02 step up of SVC-RA and left-to-right shunt. 4. Left ventriculogram showed mitral regurgitation and filling of both atrium. Operative findings were as follow: 1. Primum type atrial septal defect [2x2 cm]. 2. Cleft in the anterior leaflet of the mitral vave. 3. No evidence of ventricular septal defect and tricuspid anomaly. Through a right atriotomy with moderate hypothermia, the mitral cleft was approximated with interrupted sutures. The interatrial communication was closed by a patch of Dacron/pericardium. The patch was attached to junction of the mitral and tricuspid valves along the crest of the ventricular septum using interrupted sutures and the other site using continuous sutures. Postoperative course was uneventful and discharged in good general condition except postoperative bleeding in case 3.

  • PDF

Case Report of Partial Endocardial Cushion Defect with Mild Pulmonary Hypertension in Old Age (경증의 폐동맥 고혈압을 동반한 고령에서의 심내막상 결손 환자 치험 1예)

  • Kim Woo-Shik;An Jae-Bum;Song Chang-Min;Kim Mi-Jung;Jung Sung-Chol;Shin Yong-Chul;Kim Byung-Yul;Kim In-Sub
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.633-636
    • /
    • 2006
  • The partial endocardial cushion defect including ostium primum atrial septal defect and anterior mitral leaflet cleft, presents less significant clinical symptoms than complete endocardial cushion defect. But, as mitral insufficiency develops, cardiomegaly, congestive heart failure, pulmonary arterial hypypertension appear. So, partial endocardial cushion defect has poor prognosis and is rarely seen in elderly patients. A 67 years old woman admitted at our hospital for operative treatment with partial endocardial cushion defect. She had increased pulmonary pressure of 45/22 mmHg, mean 32 mmHg. She had repair of ostium primum defect with patch, and the mitral valve was treated with valve replacement. Because advanced atrioventricular block developed postoperatively, she received permanent pacemaker.

Thigh Perforator Free Flap for Reconstruction of the Soft Tissue Defect of the Lower Extremity (하지의 연부조직 결손 재건을 위한 대퇴부 천공지 유리 피판술)

  • Kong, Byeong-Seon;Seo, Moo-Sam;Ha, Jung-Min
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.2
    • /
    • pp.232-237
    • /
    • 2007
  • Introduction: To report the result of the thigh perforator free flap for the reconstruction of the soft tissue defect of the lower extremities and usefulness of this flap. Materials and Methods: We have performed 23 cases of thigh perforator free flap to reconstruct the soft tissue defect of the lower extremities between February 2004 and July 2005. The anterior aspect of the legs were 9 cases, the ankle joints were 4 cases, the dorsal aspect of the feet were 6 cases, the sole of the feet were 4 cases as recipient sites. The anterolateral thighs were 13 cases, the anteromedial thighs were 10 cases as donor sites. The size of the flap ranged from $4{\times}5\;cm$ to $12{\times}18\;cm$. The mean flap area was $73.2\;cm^2$. The length of the pedicle ranged from 5 cm to 15 cm. Every patient except children was operated under the spinal anesthesia. Results: 21 flaps (91.3%) survived, 2 flaps (8.7%) failed. In the 21 flaps that had survived, there were partial necrosis in 4 cases, which healed without any additional operation. In the 13 anterolateral thigh perforator flaps, 9 cases survived totally, 3 cases had the partial necrosis, 1 case failed. In the 10 anteromedial thigh perforator flaps, 8 cases survived totally, 1 case had the partial necrosis, 1 case failed. Conclusion: The authors had a good result with the thigh perforator free flap and believe that this flap is a good option for the reconstruction of the soft tissue defect of the lower extremities, because this flap has a thin thickness and it is easy to dissect the vessels. Moreover the patients can be operated with supine position.

  • PDF

Design and Fabrication of Rogowski-type Partial Discharge Sensor for Insulation Diagnosis of Cast-Resin Transformers (몰드 변압기의 절연 진단을 위한 로고우스키형 부분방전 센서의 설계 및 제작)

  • Lee, Gyeong-Yeol;Kim, Sung-Wook;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.6
    • /
    • pp.594-602
    • /
    • 2022
  • Cast-resin transformers are widely installed in various electrical power systems because of their low operating cost and low influence on external environmental factors. However, when they have an internal defect during the manufacturing process or operation, a partial discharge (PD) occurs, and eventually destroys the insulation. In this paper, a Rogowski-type PD sensor was studied to replace commercial PD sensors used for the insulation diagnosis of power apparatus. The proposed PD sensor was manufactured with four different types of PCB-based winding structures, and it was analyzed in terms of the detection characteristics for standard calibration pulses and the changes of the output voltage according to the distance. The output increased linearly in accordance with the applied discharge amount. It was confirmed that the hexagon structure sensor had the highest sensitivity, because the winding cross-sectional area of the sensor was larger than others. In addition, as the distance from the defect increased, the output voltage of the sensors decreased by 7.32% on average. It was also confirmed that the attenuation rate according to the distance decreased as the input discharge amount increased. For the application of this new type sensor, PD electrode system was designed to simulate the void defect. Waveforms and PRPD patterns measured by the proposed PD sensors at DIV and 120% of DIV were the same as the results measured by MPD 600 based on IEC 60270. The proposed PD sensors can be installed on the inner wall of the transformer tank by coating its surfaces with a non-conductive material; therefore, it is possible to detect internal defects more effectively at a closer distance from the defect than the conventional sensors.