• Title/Summary/Keyword: Partial defect

Search Result 446, Processing Time 0.029 seconds

An Analysis of the Partial Discharge Pattern Related to the Artificial Defects Introduced at the Interface in an XLPE Cable Joint using a Laboratory Model

  • Lee, Jeon-Seon;Koo, Ja-Yoon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.2C no.5
    • /
    • pp.239-245
    • /
    • 2002
  • In this work, in order to realize the possible defects at the cable joint interface, four different types of artificial defects are provided : conducting, insulating substances, void and scratches. The analysis related to the PD patterns has been performed by means of conventional Phase Resolved Partial Discharge Analysis (PRPDA) and Chaotic Analysis of Partial Discharge (CAPD) as well which was proposed by our previous communication. As a result, it could be pointed out that each defect has shown particular characteristics in its pattern respectively and that the nature of defect causing partial discharge could be identified more distinctively when the CAPD is combined with the conventional statistic method, PRPDA.

Partial Discharge Distribution Characteristics along Defect of CNC Cable (배전급 CNC케이블의 결함 종류에 따른 부분방전 분포특성)

  • Yoon, Jae-Hun;Kang, Seung-Hwa;Choi, Han-Sick;Lim, Gee-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.102-102
    • /
    • 2010
  • A purpose of this paper is to recognize partial discharge pattern for cable insulation. The classification of PD sources was widely studied for two decades. this research sought to use the partial discharge detection method, and to diagnose the interface of cable, which is deemed vulnerable of cable systems. A research abalyzed faults that can occur in the interface of cable joint as well as accident mechanisms, manufactured test 22.9kV CNC cable, invented artificial faults and carried out partial discharge detection experiments. As a result, various PD pattern along defect measured and distinguished.

  • PDF

Effect of Partial Squeeze on the Quality of Casting Products in the Vacuum Die Casting (진공다이캐스팅시 국부스퀴즈 효과가 주조품질에 미치는 영향)

  • 김억수;김성준;이광학;문영훈
    • Transactions of Materials Processing
    • /
    • v.8 no.5
    • /
    • pp.491-497
    • /
    • 1999
  • The effect of partial squeeze on the quality of casting products in the vacuum die casting was investigated to make defect free casting products with excellent mechanical properties. The partial squeeze and vacuum die casting process was industrially implemented in making reaction shaft support which was made of a hypereutectic Al-15%Si alloy. To combine squeezing and vacuum effects, the plunger injection system was designed and attached on the chill vent type vacuum machinery system. The combination of vacuum effect before injection and partial squeezing effect after injection resulted in defect free die casting products. The uniform distribution of fine eutectic and proeutectic Si obtained from trial process also provided excellent mechanical properties.

  • PDF

Partial Eyebrow Reconstruction with Bilateral Advancement Flap and Tattooing (양측 전진피판과 문신을 이용한 부분 눈썹 결손의 치험례)

  • Yoon, Jung Ho;Hong, Jong Won;Kim, Young Seok;Roh, Tai Suk;Rah, Dong Kyun
    • Archives of Craniofacial Surgery
    • /
    • v.11 no.1
    • /
    • pp.37-40
    • /
    • 2010
  • Purpose: Reconstruction of eyebrow defects after wide excision of the benign and malignant tumors present a cosmetic challenge to the plastic surgeon. There were several methods for reconstruction of partial eyebrow defect with local flaps except hair bearing composite graft. We introduce simple eyebrow reconstruction with bilateral advancement flap and tattooing on the idea that eyebrow tattooing is popular permanent eyebrow makeup among elderly Korean women. Methods: The flaps were designed on both ends of the eyebrow defect along the upper and lower margin of the eyebrow. Both flaps were cut, undermined and were moved centrally to cover the defect. Both flaps were attached along the vertical suturing line. The rest of each flap was sown with dog-ears revised minimally. Scar lines would be hidden along the natural borders of the eyebrow if possible. The resulting vertical scar finally was covered with hair. After 8 months, eyebrow tattooing would be done to camouflage eyebrow shortening and scar. Results: Partial eyebrow defect was reconstructed successfully with bilateral advancement flap and tattooing. The postoperative scar was inconspicuous and eyebrow looked symmetric. Conclusion: We recommend partial eyebrow reconstruction with bilateral advancement flap and tattooing for the elderly Korean female patients after excision of small tumor in and around eyebrow region.

Analysis of Parameters on Partial Discharges from Insulation Defects of used Hydro Generator Stator Windings (수력발전기 고정자 노후권선의 모의결함 시편에 대한 부분방전 파라미터 변화 분석)

  • Oh, Bong-Keun;Kim, Hyun-Il;Kang, Seong-Hwa;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.7
    • /
    • pp.645-649
    • /
    • 2007
  • Partial discharge(PD) test for simulated insulation defects of used hydro generator stator winding was conducted to analyze the PD Parameters. Simulated insulation defects are classified by 5 types corona, slot, internal, multi and aging defect. Phase resolved partial discharge, statistical parameter (skewness, kurtosis), PD magnitude as a function of the test voltage(Q-V curve) and PD magnitude change under test voltage for 2 minutes are used as PD parameters. The analysis of PD parameters by 4 types are proved to be useful methods. In particular, PD parameter characteristics of aging defect could help to assess the aging condition of stator winding because aging defect has more weak insulation strength than other insulation defects : PD distribution is wide and flat, PD rises rapidly near $0^{\circ}\;and\;180^{\circ}$ and Q-V curve rises sharply and then gently drops.

The Comparison between Anterolateral Thigh Free Flap and Radial Forearm Free Flap in Partial Glossectomy Defect - An Evaluation of Donor Site Morbidity and Functional Outcome (유리 전외측 대퇴부 피판과 유리 요측 전박피판을 이용한 설재건 시공여부 및 기능적 결과 비교)

  • Cho, Sang Hyun;Lee, Won Jai;Lew, Dae Hyun;Tark, Kwan Chul
    • Archives of Plastic Surgery
    • /
    • v.34 no.3
    • /
    • pp.330-335
    • /
    • 2007
  • Purpose: The purpose of this study is to evaluate the functional outcome and donor site morbidity of anterolateral thigh free flap(ALT) compared to Radial forearm free flap(RFFF) for the reconstruction of partial glossectomy defect. Methods: 5 ALT free flap (group I) were attempted for partial glossectomy patients. We compared patients undergone ALT flap with those(n=11) of similar size defect reconstructed with RFFF (Group II). Rating scales for articulation and swallowing function were applied and donor site morbidity have been evaluated. Results: The scales for speech function showed no difference between the two groups (average score; group I - 6.4, group II - 6.45). Swallowing function also showed no difference between the two groups(average score; Group I - 6.6, Group II - 6.27). ALT group had one patient with donor site morbidity(numbness). All of the RFFF patients(11/11) complained and suffered from hypertrophic scar, retraction, numbness or hyperpigmentation on forearm donor site. Based on our study, ALT free flap is comparable to that of RFFF in terms of functional assessment in tongue reconstruction. Conclusion: Considering the donor site morbidity, ALT flap is to be valuable to reconstruct partial glossectomy defect.

UHF Partial Discharge Measurement Technology using a Dual Bands Methods to have the Frequency Characteristics in GIS (GIS에서 주파수 특성을 갖는 이중 대역법에 의한 UHF 부분방전 측정기술)

  • Yi, Sang-Hwa;Sun, Jong-Ho;Kang, Dong-Sik;Kim, Kwang-Hwa
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.3
    • /
    • pp.127-133
    • /
    • 2006
  • This Paper describes a dual bands PD measurement method which has two different bandwidths. The one bandwidth is 0.5 - 2 GHz and the other is 1 - 2GHz. This method is used for GIS diagnosis. In the experiment, it shows that the ratios between two PD quantities in dual bands depend on the defect types and gas pressures. The variations of ratios in different pressures are more sensitive than ones in defect types. And These ratios increase with increasing SF6 gas pressures. As these ratios give us additive information of PD we can analyze the defect type as well as risk assessment for the GIS reliably. Therefore the above result shows that these ratios are one of parameters for diagnosing GIS.

Transport Mechanisms and Defect Structures of the System $\alpha$-Fe$_2O_3$-CoO

  • Kim, Keu-Hong;Lee, Sung-Han;Choi, Jae-Shi
    • Bulletin of the Korean Chemical Society
    • /
    • v.7 no.5
    • /
    • pp.341-346
    • /
    • 1986
  • The electrical conductivity of the system ${\alpha}-Fe_2O_3-CoO$ was measured in the temperature range 200-1000$^{\circ}C$ and PO$_{2}$ range 10$^{-7}-2{\times}10^{-1}$ atm. Possible defect models were suggested on the basis of conductivity data, which were measured as a function of temperature and of oxygen partial pressure. The observed activation energies were 0.50 eV and 1.01 eV in the low- and high-temperature regions, respectively. The observed conductivity dependences on PO$_{2}$ were ${\sigma}\;{\alpha}\;PO_2^{-1/6}$ in the PO$_{2}$ range $10^{-7}-10^{-4}$ atm and ${\sigma}\;{\alpha}\;PO_2^{-1/4}$ at PO$_{2}$ 's of $10^{-4}-2{\times}10^{-1}$ atm at temperatures from 300-1000$^{\circ}C$. An extrinsic electron conduction due to an Vo defect and an intrinsic electron conduction due to an Fei' defect were suggested at different temperature and oxygen partial pressure regions, respectively.

Ability of non-destructive assay techniques to identify sophisticated material partial defects

  • Lloyd, Cody;Goddard, Braden
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1252-1258
    • /
    • 2020
  • This study explores the ability of non-destructive assay techniques to detect a partial material defect in which 100 g of plutonium are diverted from the center of a 1000 g can of PuO2 powder. Four safeguards measurements techniques: neutron multiplicity counting, calorimetry, gravimetry, and gamma ray spectroscopy are used in an attempt to detect the defect. Several materials are added to the partial defect PuO2 can to replicate signatures of the diverted material. 252Cf is used to compensate for the doubles neutron counts, 241Am is used to compensate for the decay heat, and aluminum is used to compensate for the weight. Although, the doubles and triples difference before and after diversion are statistically indistinguishable with the AWCC in fast and thermal mode, the difference in the singles counts are statistically detectable in both modes. The relatively short half-life of 252Cf leads to a decrease (three sigma uncertainty) in the doubles neutron counts after 161 days. Combining this with the precise quantity of 241Am needed (10.7 g) to mimic the heat signature and the extreme precision in 252Cf mass needed to defeat neutron multiplicity measurements gives reassurance in the International Atomic Energy Agency's ability to detect partial material defects.

Defect Structure and Electrical Conductivities of $SrCe_{0.95}Yb_{0.05}O_3$ ($SrCe_{0.95}Yb_{0.05}O_3$의 결함엄개와 전기전도 특성)

  • 최정식;이도권;유한일
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.3
    • /
    • pp.271-279
    • /
    • 2000
  • 5 m/o Yb-doped SrCeO3 proton conductor was prepared by a solid state reaction method and its total electriccal conductivity measured as a function of both oxygen partial pressure and water vapor partial pressure in the temperature range of 500~100$0^{\circ}C$. From the total conductivity have been deconvoluted the partial conductivities of oxide ions, protons, and holes, respectively, on the basis of the defect model proposed. The equilibrium constant of hydrogen-dissolution reaction, proton concentration, and mobilities of oxygen vacancies and protons have subsequently been evaluated. It is verified that SrCe1-xYbxO3 is a mixed conductor of holes, protons and oxide ions and the proton conduction prevails as temperature decreases and water vapor pressure increases. The heat of water dissolution takes a representative value of $\Delta$HoH=-(140$\pm$20) kJ/mol-H2O, but tends to be less negative with increasing temperature. Migration enthalpies of proton and oxygen vacancy are extracted as 0.83$\pm$0.10 eV and 0.81$\pm$0.01 eV, respectively.

  • PDF