• Title/Summary/Keyword: Partial defect

Search Result 448, Processing Time 0.021 seconds

A study on the reduction of PD generated in the PT for 25.8 kV (25.8 kV용 PT에서 발생하는 부분방전 저감에 관한 연구)

  • 송재주;이중근;김성홍;서용균;나도간;한병성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.631-635
    • /
    • 2000
  • Recently, the epoxy molded type PT for indoor and applied 25.8kV was often distroyed by degradation of insulation that effected many electric stress and defect of manufactured goods. therefore In this work, We can present a method of solution in the process of produce the PT through analysis of experiments. In order to reduce the PD (Partial Discharge) which was occurred at the insulation material of epoxy resin, we has many tried to remove faults In the process of the products,

  • PDF

Analysis of the Insulation aging for the stator winding (고정자권선의 절연열화 특성분석)

  • Oh, Bong-Keun;Choi, Kyo-Nam;Han, Chang-Dong;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.23-24
    • /
    • 2006
  • Stator winding of hydro generator is gradually deteriorated by multi-stress and steady degradation of insulation results in insulation breakdown. The region where insulation breakdown occurs in stator winding is part where the multi-stress causes the defect of insulation material and electrical stress has been concentrated. Therefore, we judged locations of insulation breakdown to be varied according to various stress factors in service. In this paper, we drew the stator winding of hydro generators which has run for a long time and separated it into 3 parts(central part, end winding part, drawing part) according to the positions laid on the core. We performed electrical and thermal stress on these specimens for 1000 hrs under the same condition, measured the condition regularlyand analyzed the insulation status of each winding by performing partial discharge test. In addition, we analyzed the trend of partial discharge concerning specimens that caused the insulation breakdown during aging.

  • PDF

One case of surgical treatment for chylopericardium following cardiac surgery (개심술후 유미심낭 (Chylopericardium) 합병증의 수술치험 1예)

  • 김삼현
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.695-698
    • /
    • 1986
  • Only five instances of chylopericardium following cardiac surgery have been reported in the literature previously. We encounted this complication in a patient who was operated on for secundum atrial septal defect. The patient readmitted one month after discharge because of large amount of chylous pericardial effusion. Conservative treatment of pericardiostomy drainage and parenteral hyperalimentation was continued for 3 weeks without improvement. Partial pericardiectomy and pericardiopleural window was done with success and no recurrence of chylopericardium was observed upto 3 months after surgery. We think this is the first case report of chylopericardium after open heart surgery in Korea.

  • PDF

Inferior Orbital Wall Reconstruction with Vascularized Partial Thickness Calvarial Bone Flap in Three Cases of Maxillary Tumor (혈행화된 부분층 두개골피판을 이용한 상악골 종양 적출 환자에서의 안와하벽 재건술 증례)

  • Shin, Sang Ho;Lee, Yoon Jung;Kim, Jun Sik;Kim, Nam Gyun;Lee, Kyung Suk
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.1
    • /
    • pp.49-54
    • /
    • 2009
  • Purpose: Inevitably, Maxillary structural defect follows maxillary cancer extirpation. Maxillary reconstruction is over every surgeon's head. Every physician tried to overcome limited donor site of craniofacial defect. We considered to suggest optimal method of inferior orbital wall defect in functional point as well as esthetic point. Methods: We performed wide excision of maxilla and vascularized partial thickness calvarial bone flap to reconstruct the defect from cancer extirpation in three cases. We select ipsilateral superficial temporal artery, vein and outer cortex of parietal bone flap as donor. And we applied bone flap as inferior orbital wall structure. The bony surface was wrapped with fascia to prevent direct contact between orbital contents and rough bony flap surface. Computed tomography image was checked during follolw up period. Results: We can observe these patients for over two years. In all three cases, We can get fair inferior orbital wall structure. Even though they got radiation therapy, there was no limitation of extraocular movements, no diplopia. no enophthalmos. Also there was minimal donor site morbidity. Conclusion: We suggest vascularized calvarial bone flap is practically excellent strategy for inferior orbital wall reconstruction.

Electrical Conductivity of S$m_2O_3-ZrO_2$ Systems (S$m_2O_3-ZrO_2$계의 전기전도성)

  • Jeong Hwan Cho;Keum Hwi Chang;Keu Hong Kim;Yong Bae Kim;Jae Shi Choi
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.6
    • /
    • pp.608-614
    • /
    • 1985
  • Electrical conductivities of $ZrO_2-Sm_2O_3$ systems containing 10, 20, 30, 40, and 50 mol% of $ZrO_2$ have been measured as a function of temperature and of oxygen partial pressure at temperature from 500 to 1000${\circ}C$ and oxygen partial pressures from 1 ${\times}10^{-5}to 1{\times}10^{-1}$ atm. Plots of log conductivity vs. 1/T are found to be linear with an inflection point at around 650$^{\circ}C$ and the temperature dependence of conductivity shows two different defect structures. The conductivities are increased with increasing pressure, slowing a p-type character. The electrical conductivity dependences on $Po_2$ are found to be ${\sigma}{\propto}Po_2^{1/5.3}$ at 650∼1000$^{\circ}C$ and ${\sigma}{\propto}Po_2^{1/6}$ at 500∼650$^{\circ}C$, respectively, The defect structures are Oi" at 650-1000$^{\circ}C$ and $Vs_m$"' at 500-650$^{\circ}C$. The electron hole is main carrier type, however ionic contribution is found at low temperature portion. Ionic contributions increased with the increasing amount of $ZrO_2$ dopant. In 60mol% $ZrO_2-Sm_2O_3$ system, the conductivity is increased with decreasing oxygen pressure.

  • PDF

Partial Discharge Process and Characteristics of Oil-Paper Insulation under Pulsating DC Voltage

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Jiang, Tianyan;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.436-444
    • /
    • 2016
  • Oil-paper insulation of valve-side windings in converter transformers withstand electrical stresses combining with AC, DC and strong harmonic components. This paper presents the physical mechanisms and experimental researches on partial discharge (PD) of oil-paper insulation at pulsating DC voltage. Theoretical analysis showed that the phase-resolved distributions of PDs generated from different insulated models varied as the increase of the applied voltages following a certain rule. Four artificial insulation defect models were designed to generate PD signals at pulsating DC voltages. Theoretical statements and experimental results show that the PD pulses first appear at the maximum value of the applied pulsating DC voltage, and the resolved PD phase distribution became wider as the applied voltage increased. The PD phase-resolved distributions generated from the different discharge models are also different in the phase-resolved distributions and development progress. It implies that the theoretical analysis is suitable for interpretation of PD at pulsating DC voltage.

A method to reject noise signals in partial discharge signals of turbine generator (터빈 발전기의 부분방전 신호 중 노이즈 제거 방법)

  • Park, Y.H.;Park, P.G.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.240-242
    • /
    • 2005
  • It is well known that the PD (Partial Discharge) signals are generated if insulators have some defects such as voids in electrical facility and various PD detection methods are developed for preventing electrical troubles. So, an interest for the PD signals is higher and higher according to the high concern for the defects detection method of the aging electrical facility. When the equipment to detect PD signals installed at site and it works, a lot of noises flow in the equipment from surrounding situation and it will be mixed with original PD waveform. So we can not get the desired PD waveform. Therefore, there are many trial to reject or suppress the noise from the PD signals from long times ago. The greater of them used the hardware such as bridge circuits and frequency filters to suppress the noise. This paper proposed a novel noise rejection method in acquired data from PD detection equipment. The noise has the irregular phase and higher signal level than real PD, and noise decision is performed after inspection of pulse distribution in ${\Phi}$-q-n graph of acquired data from PD detection equipments. By experimental results on high voltage electric equipments, it is shown that proposed method has good performance. It is expected that this noise rejection technology is useful in numeric calculation and trend management of PD level.

  • PDF

Surgical Management of Coarctation of the Aorta with a Ventricular Septal Defect and Coexisting Partial Anomalous Pulmonary Venous Connection -A case report- (부분 폐정맥 환류 이상과 심실 중격 결손을 동반한 대동맥 축착증의 완전교정 -1예 보고-)

  • Kim Si-Ho;Lee Young-Seok;Woo Jong-Soo;Cho Kwang-Jo
    • Journal of Chest Surgery
    • /
    • v.39 no.6 s.263
    • /
    • pp.479-481
    • /
    • 2006
  • A newborn girl with a partial anomalous pulmonary venous connection, coarctation of the aorta, and ventricular and atrial septal defects underwent a complete repair successfully at 49 days of age. In this case, the left upper pulmonary vein was connected to the left innominate vein via an atypical vertical vein.

Analysis of Off-Line and On-Line Partial Discharge in High Voltage Motor Stator Windings

  • Kim, Hee-Dong;Kong, Tae-Sik;Lee, Sang-Kil;Kim, Beom-Soo;Kim, Doo-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1086-1092
    • /
    • 2015
  • The off-line and on-line partial discharge (PD) in the stator winding of three high-voltage (HV) motors (1,400 HP, 6.6 kV) is measured and analyzed in this paper. The off-line PD is measured at high values between 24,300 ~ 36,100 pC after 18 years of motor operation. Spare replacement motors were not available for testing the degree of deterioration of the stator windings in standstill status. Therefore, on-line periodic analysis was conducted to monitor the trend of PD after installing a ceramic sensor (110 pF, 6.6 kV) in the terminal box for each phase of each motor. In the stator winding of the No.1 and No.2 HV motors, which showed high magnitudes of off-line PD and low magnitudes of on-line PD, defects are expected to appear in the neutral end of the winding. On the contrary, in the stator windings of the No.3 HV motor, which exhibits high off-line and on-line PD magnitude, defects are expected to appear in the terminal end of the winding where a voltage close to the phase voltage is applied.

Analysis of Partial Discharge in High Voltage Motor Model Coils (고압전동기 모델 코일에서 부분방전 분석)

  • Kim, Hee-Dong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.178-182
    • /
    • 2006
  • Five model coils of 6.6 kV motor were manufactured with several defects. These stator coils have artificial defects such as void of groundwall insulation, removal of semi-conductive coating and damage of strand insulation. Epoxy-mica coupler(80 pF) was connected to five model coil terminals. The voltage applied to the coils was 3.81 kV, 4.76 kV, 6.0 kV and 6.6 kV, respectively. Partial discharge(PD) tests performed in the laboratory and shield room. Digital PD detector(PDD) and turbine generator analyzer(TGA) were used to measure PD activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of model coils were indicated the internal and slot discharges. PD patterns are consistent with the result of measurement using PDD and TGA instruments. AC breakdown test was performed on five model coils in order to confirm the result of PD measurements. All the failures were located in a line-end coil at the exit from the core slot.