• Title/Summary/Keyword: Partial Field

Search Result 928, Processing Time 0.024 seconds

Non-linear distributed parameter system estimation using two dimension Haar functions

  • Park Joon-Hoon;Sidhu T.S.
    • Journal of information and communication convergence engineering
    • /
    • v.2 no.3
    • /
    • pp.187-192
    • /
    • 2004
  • A method using two dimension Haar functions approximation for solving the problem of a partial differential equation and estimating the parameters of a non-linear distributed parameter system (DPS) is presented. The applications of orthogonal functions, including Haar functions, and their transforms have been given much attention in system control and communication engineering field since 1970's. The Haar functions set forms a complete set of orthogonal rectangular functions similar in several respects to the Walsh functions. The algorithm adopted in this paper is that of estimating the parameters of non-linear DPS by converting and transforming a partial differential equation into a simple algebraic equation. Two dimension Haar functions approximation method is introduced newly to represent and solve a partial differential equation. The proposed method is supported by numerical examples for demonstration the fast, convenient capabilities of the method.

Partial Discharge Distribution Analysis on Interlace Defects of Cable Joint using K-means Clustering (K-means 클러스터링을 이용한 케이블 접속재 계면결함의 부분방전 분포 해석)

  • Cho, Kyung-Soon;Hong, Jin-Woong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.11
    • /
    • pp.959-964
    • /
    • 2007
  • To investigate the influence of partial discharge(PD) distribution characteristics due to various defects on the power cable joints interface, we used the K-means clustering method. As the result of PD number(n) distribution analyzing on $\Phi-n$ graph, the phase angle($\Phi$) of cluster centroid shifted to $0^{\circ}\;and\;180^{\circ}$ increasing with applying voltage. It was confirmed that the PD quantify(q) and euclidean distance of centroid were increased with applying voltage from the centroid distribution analyzing of $\Phi-q$ plane. The dispersion degree was increased with calculated standard deviation of the $\Phi-q$ cluster centroid. The PD number and mean value on $\Phi-q$ graph were some different by electric field concentration with defect types.

Updates to the wind tunnel method for determining design loads in ASCE 49-21

  • Gregory A. Kopp
    • Wind and Structures
    • /
    • v.37 no.2
    • /
    • pp.163-178
    • /
    • 2023
  • The paper reviews and discusses the substantive changes to the ASCE 49-21 Standard, Wind Tunnel Testing for Buildings and Other Structures. The most significant changes are the requirements for wind field simulations that utilize (i) partial turbulence simulations, (ii) partial model simulations for the flow around building Appurtenances, along with requirements for determining wind loads on products that are used at multiple sites in various configurations. These modifications tend to have the effect of easing the precise scaling requirements for flow simulations because it is not generally possible to construct accurate models for small elements placed, for example, on large buildings at the scales typically available in boundary layer wind tunnels. Additional discussion is provided on changes to the Standard with respect to measurement accuracy and data acquisition parameters, such as duration of tests, which are also related to scaling requirements. Finally, research needs with respect to aerodynamic mechanisms are proposed, with the goal of improving the understanding of the role of turbulence on separated-reattaching flows on building surfaces in order to continue to improve the wind tunnel method for determining design wind loads.

CONTROL FUNCTION BASED COUPLED AND COMMON COUPLED FIXED POINT THEOREMS IN PARTIAL METRIC SPACES

  • H. K. Nashine;G. S. Saluja;G. V. V. Jagannadha Rao;W. H. Lim
    • Nonlinear Functional Analysis and Applications
    • /
    • v.29 no.2
    • /
    • pp.559-580
    • /
    • 2024
  • In this paper, we aim to prove coupled and common coupled fixed point theorems for contractive type conditions in the context of partial metric spaces by means of a control function, and to provide some corollaries of the established results. This paper presents a number of results that generalize and extend previous work in the field. In order to better illustrate the process, we provide examples.

Study into prosodic morphological analysis in Korean and Standard Chinese partial reduplication and contrastive analysis using optimality theory (한국어와 표준 중국어 부분 중첩 의성·의태어에 대한 운율 형태론적 분석의 문제와 최적성 이론적 분석을 통한 대조 분석)

  • Chang, Jae-Woong
    • Cross-Cultural Studies
    • /
    • v.49
    • /
    • pp.275-301
    • /
    • 2017
  • Based on the previous analysis by Wanghongjun(2008), this paper applies Optimality Theory (OT) to the field of partial reduplication in Korea to increase its scientific validity. Toward this end, I propose an alternative analysis of Korean partial reduplication, applied as a single process of prefixation. Reduplicated words by prefixation are divided into two types: with a heavy syllable of the stem, and another with the stem. The two types of partial reduplication are closely related by the sound features. In addition, I discussed Chinese partial reduplication from a prefixation perspective within the framework of OT and performed contrastive analysis of Korean and Standard Chinese processes of reduplication by focusing on constrained rankings. As a result, the alternative analysis showed a systematic relationship among the reduplicated words in Korean and Standard Chinese. Lastly, I explained that the coronal /t/ and liquid /l/ have a special functional hierarchy in both languages. This study can be re-explained based on the framework of OT according to a few major constraints, involving MAX-BR, MAX-IO. Their rankings show the adequacy of analysis.

Optimum Design of Glass Net in 2[MVA] Mold Transformer (2[MVA] 배전용 몰드변압기의 글라스넷 형상 최적설계)

  • Jeon, Mun-Ho;Kim, Chang-Eob
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.107-112
    • /
    • 2011
  • In this paper, the optimum design of the glass net shape was studied to minimize the electric field of mold transformer. The glass net is used for reinforcement in structure between coils and epoxy, but it can cause to increase the electric field and the partial discharge. Therefore, the optimum design of glass net is required to minimize the electric field. In this paper, the objective function was approximated by using response surface method and then Zoom-in method was used for optimal design to minimize the electric field. The electric field was analysed using finite element method for each shape of glass nets.

Analysis of Partial Discharge Phenomena by means of CAPD (CAPD기법을 이용한 부분방전 현상 해석에 관한 연구)

  • Kim, Sung-Hong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.939-944
    • /
    • 2002
  • PD phenomena can be regarded as a deterministic dynamical process where PD should be occurred if the local electric field be reached to be sufficiently high. And thus, its mathematical model can be described by either difference equations or differential equations using several state variables obtained from the time sequential measured data of PD signals. These variables can provide rich and complex behavior of detectable time series, for which Chaos theory can be employed. In this respect, a new PD pattern recognition method is proposed and named as 'Chaotic Analysis of Partial Discharges (CAPD)' for this work. For this purpose, six types of specimen are designed and made as the models of the possible defects that may cause sudden failures of the underground power transmission cables under service, and partial discharge signals, generated from those samples, are detected and then analyzed by means of CAPD. Throughout the work, qualitative and quantitative properties related to the PD signals from different defects are analyzed by use of attractor in phase space, information dimensions ($D_0$ and D2), Lyapunov exponents and K-S entropy as well. Based on these results, it could be pointed out that the nature of defect seems to be identified more distinctively when the CAPD is combined with traditional statistical method such as PRPDA. Furthermore, the relationship between PD magnitude and the occurrence timing is investigated with a view to simulating PD phenomena.

  • PDF

The Characteristics of PV module under the Partial Shading Condition and with a Failure of Bypass Diode with Short (PV모듈의 음영 상태 및 바이패스 다이오드 단락 고장 특성 분석)

  • Ko, Suk-Whan;Ju, Young-Chul;So, Jung-Hun;Hwang, Hye-Mi;Jung, Young-Seok;Kang, Gi-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.4
    • /
    • pp.41-47
    • /
    • 2016
  • A bypass diode is connected in parallel to solar cells with opposite polarity. The advantage of using the bypass diode is circumvented a destructive efforts of hot-spot heating in the photovoltaic(PV) module. In addition, it is possible to reduce a energy loss under the partial shading on the PV module. This paper presents a characteristic of photovoltaic module under partial shading condition and with defective bypass diode by using the experimental data. The results of field testing for each photovoltaic modules, when photovoltaic system which is connected power grid is operating, the inner junction-box temperature of shading photovoltaic module is high $5^{\circ}C$ because of difference of flowing current through into bypass diode. And incase of not operating photovoltaic system, the inner junction-box temperature of module with defective bypass diode is greatly higher than partial shading PV module.

Aerodynamic Shape Design of a Partial Admission Turbine Using CFD (CFD를 이용한 부분흡입형 터빈 공력형상 설계)

  • Lee, Eun-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.11 s.254
    • /
    • pp.1131-1138
    • /
    • 2006
  • Aerodynamic shape design of a partial admission turbine using CFD has been performed. Two step approaches are adopted in this study. Firstly, two-dimensional blade shape is optimized using CFD and genetic algorithm. Initially, the turbine cascade shape is represented by four design parameters. By controlling the design parameters as variables, the non-gradient search is analyzed for obtaining the maximum efficiency. The final two-dimensional blade proved to have a more blade power than the initial blade. Secondly, the three-dimensional CFD analysis including the nozzle, rotor and stator has been conducted. To avoid a heavy computational load due to an unsteady calculation, the frozen rotor method is implemented in steady calculation. The frozen rotor method can detect a variation of the flow-field dependent upon the blade's circumferential position relative to the nozzle. It gives a better idea of wake loss mechanism starting from the lip of the nozzle than the mixing plane concept. Finally, the combination of two and three dimensional design method of the partial admission turbine in this study has proven to be a robust tool in development phase.

Partial Discharge Characteristics in LLDPE-Natural Rubber Blends: Correlating Electrical Quantities with Surface Degradation

  • Aulia, Aulia;Ahmad, Mohd Hafizi;Abdul-Malek, Zulkurnain;Arief, Yanuar Z.;Lau, KwanYiew;Novizon, Novizon
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.699-706
    • /
    • 2016
  • Partial discharges (PD) lead to the degradation of high voltage cables and accessories. PD activities occur due to the existence of impurities, voids, contaminants, defects and protrusions during the manufacture and installation of power cables. Commonly, insulation failures occur at cable joints and terminations, caused by inhomogeneous electric field distributions. In this work, a blend of natural rubber (NR) and linear low density polyethylene (LLDPE) was investigated, and the optimal formulation of the blend that could resist PD was discussed. The experiments were conducted under a constant high voltage stress test of 6.5 kV AC and the magnitude of partial discharge activities was recorded using the CIGRE method II. Pattern analysis of PD signals was performed along with the interpretation of morphological changes. The results showed that the addition of 10 wt% of NR and 5 wt% of Alumina Trihydrate (ATH) provided promising results in resisting PD activities. However, as the NR content increased, more micropores existed, thus resulting in increased PD activities within the samples.