• Title/Summary/Keyword: Partial Discharges

Search Result 206, Processing Time 0.025 seconds

A New Possible Partial Discharge Detection Technique using Electro-optic Effect (전기광학 효과를 이용한 부분방전 신호의 검출)

  • Noh, S.S.;Chang, Y.M.;Lee, J.H.;Koo, J.Y.;Oh, C.H.;Kim, J.T.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1929-1931
    • /
    • 1996
  • In this work, it is proposed new PD(partial discharge) detection technique using electro-optic effect, for which partial discharges generated from needle-plane electrode in air were detected through optical measuring system by use of $LiNbO3_3$ electro-optic crystal. As a result, it is noticed that PD measurable phase intervals are limited by the asymmetrical D-E hysteresis loop of the crystal with defects and half-wave voltage. However, both number of measured PD pulses and their amplitude were increased with applied voltage, which likely implies that it is possible to detect PD through newly proposed electro-optic method.

  • PDF

The Analysis and Diagnosis on Location of Partial Discharge in Underground Distribution Cable (지중 배전케이블 부분방전 위치추정 진단 및 분석)

  • Yoon, Ji-Sub;Kim, Woo-Bin;Yoon, Sung-Ho;Choi, Won;Kim, Jeong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1160-1161
    • /
    • 2015
  • In order to analyze and diagnosis on Location of partial discharge in underground distribution cable, partial discharges were measured using eletromagnetic sensors, oscilloscope, PDMS system at on-site underground multi-circuit switches. Throughout the analysis using 3-phase simultaneous pulse analysis and pulse polarity comparison of circuits, it is possible to separate noises and PD pulses and to find out the location of the pulses.

  • PDF

Ultra-fast meseurement of partial discharge current due to conducting particle in Gas-insulated System (GIS) (가스절연기기 내부의 금속 이물질에 의한 초고속 부분방전량 및 전류 측정)

  • Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.160-164
    • /
    • 2002
  • A special discharge cell containing a free conducting particle was used to generate the discharges in $SF_6$. The analog bandwidth of the measurement system exceeded 5 GHz. The measured signals were processed to compensate for the response of the measurement system. The discharge current rise time was in the range of 70 ps, while its full-width half-maximum was 120 ps. Single and double current pulses of positive and negative polarities were measured. Likewise, these pulses were compared with the measurement obtained using a conventional partial discharge detector of the IEC60270 type

  • PDF

Analysis of On-Line Partial Discharge in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 운전중 부분방전 분석)

  • Lee, Sang-Kil;Kim, Hee-Dong;Kim, Kwang-Hun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.152-155
    • /
    • 2002
  • During normal operation, partial discharge(PD) tests were performed using turbine generator analyzer(TGA) in high voltage motor. Epoxy-mica couplers are installed at motor terminal and analyzed PD signal using TGA. #A motor stator insulation is good because small partial discharges are detected PD pattern show that PD occurs in insulation. PD of #B motor is larger than that of #A motor and PD pattern show that positive PD larger than negative PD. It means that PD occurs between insulation and slot. And A phase PD magnitude of #B motor is large and high compare with any other phase. Therefore wedge, core and slot of #B motor need to check and repair.

  • PDF

Analysis of On-Line Partial Discharge in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 운전중 부분방전 분석)

  • Lee, Sang-Kil;Kim, Hee-Dong;Kim, Kwang-Hun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.199-202
    • /
    • 2002
  • During normal operation, partial discharge(PD) tests were performed using turbine generator analyzer(TGA) in high voltage motor. Epoxy-mica couplers are installed at motor terminal and analyzed PD signal using TGA. #A motor stator insulation is good because small partial discharges are detected. PD pattern show that PD occurs in insulation. PD of #B motor is larger than that of #A motor and PD pattern show that positive PD larger than negative PD. It means that PD occurs between insulation and slot. And A phase PD magnitude of #B motor is large and high compare with any other phase. Therefore wedge, core and slot of #B motor need to check and repair.

  • PDF

A study on the On-Line Diagnostic Technique of High Voltage Induction Motor by partial discharge Pattern Analysis (부분방전 패턴분석에 의한 고압유도전동기 무정전 진단기법 연구)

  • Jung, Young-Ill;Lee, Eun-Suk;Kim, Duck-Keun;Lim, Yung-Bae;Kim, Jong-Seo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1685-1687
    • /
    • 2002
  • High voltage(H.V.) induction motors have been applied to various industrial applications. But aging and failure of induction motors are initiated by electrical, mechanical, thermal and chemical processes during manufacturing or in-service. These detects reduce locally the dielectric strength of the insulation. At such defects partial discharges can occur, which cause further degradation of the insulation and reduce the life time of the H.V induction motors. Consequently in this paper, we studied the partial discharge pattern analysis of H.V. induction motor for on-site applications.

  • PDF

RECOGNITION OF TREE GROWING USING PD SIGNAL ANALYSIS IN LOW DENSITY POLYERHYLENE BLENDED WITH ANILINE (Aniline이 첨가된 LDPE에서 부분방전 펄스 분석에 의한 트리성장 길이의 인식)

  • 육형상;강성화;임기조;박수길;박대희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.11a
    • /
    • pp.202-205
    • /
    • 1994
  • There is a close relation between electrical treeing and internal partial discharges in solid dielectrics. In this paper, the characteristics of electrical treeing and partial discharge in solid dielectrics are investigated. We carried out the measurements of electrical treeing and PD(partial discharge) characteristics. From the experimental results, we found out that maximum PD magnitude increased linearly with time at first stage, thereafter increased remarkably. These tendencies are very similar to the characteristics of tree growth with time.

A Study on the Affection of Conducting Particle in Cable Splice by Ultrasonic Method (초음파 기법에 의한 케이블 접속재 내부파티클 영향 연구)

  • Park, Chi-Young;Lee, Dong-Zoon;Kwon, Chang-O;Kwak, Hee-Ro;Song, Il-Keun;Park, Ha-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1853-1855
    • /
    • 1997
  • This paper describes the characteristics of partial discharge generated by conducting particle in cable splice using ultrasonic method. For simulating partial discharges generated by defects, outer semi conductor of cable splice as ring share electrode was used. The conductive particle was attached on the surface of cable insulator(XLPE) to examine the affection of conducting particles in cable splice. The correlation between the partial discharge quantity and the magnitude of the ultrasonic signal was investigated as the number, length, diameter and alignment of particle when applied voltage increased.

  • PDF

Insulation Performance Estimation of Main Relays by Partial Discharges (부분방전에 의한 주계전기의 절연성능 평가)

  • Kil, Gyung-Suk;Kim, Il-Kwon;Park, Dae-Won;Song, Jae-Yong;Lee, Gang-Won;Cho, Eun-Je
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.4
    • /
    • pp.388-392
    • /
    • 2007
  • A new dielectric test on main relays of electric traction vehicles, the partial discharge(PD) test, is proposed. The PD test will not affect the insulation performance of specimen during the test and provide much more detailed information on insulation, the types of defects, and so on. Insulation performance of relays is estimated by discharge inception voltage(DIV), discharge extinction voltage (DEV), and apparent charge as a function of test voltage and time. Three main relays of different manufacturing date were estimated by applying AC voltage with three patterns in ranges of $0{\sim}1,200[V]$. From the results, we could estimate insulation state and which types of defects exist in them.

Aging Diagnosis of Model Coil of HV Induction Motor Using HFPD and Neural Networks (HFPD 및 신경회로망을 이용한 고압 유도전동기 모델코일 열화진단)

  • Kim, Deok-Geun;Im, Jang-Seop;Yeo, In-Seon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.8
    • /
    • pp.361-367
    • /
    • 2002
  • Many failures in high voltage equipment are preceded by partial discharge activity. In this paper deals with the application of the high frequency partial discharge measurement technique in motorette. HFPD measurement is very effective method to detect the PD occurred in motorette which is the called name of test specimen for accelerating test of stator winding[1] In this study, CT type HFPD sensor is used to detect the partial discharges and a measured HFPD pattern is analyzed by fractal mathematics. The neural network algorithm is used to pattern recognition and ageing diagnosis. As a result of this study, the fractal dimensions are increased along to applied voltage and HFPD pattern recognition using neural network shown excellent recognition rate. Also, the ageing diagnosis of motorette has been Possible.