• 제목/요약/키워드: Part load operation

검색결과 227건 처리시간 0.023초

2MWe 순환유동상 보일러의 부분 부하 운전 성능 모사 (Performance Simulation of Part Load Operation for 2MWe Circulating Fluidized Bed Boiler)

  • 김태현;최상민;현주수
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.35-36
    • /
    • 2012
  • Part load operation usually covers large periods of the total operation time on the economic ground and electricity demand in small-scale boilers. Performance analysis of part load behavior is very important for the purpose of boiler operation optimization. A simple thermal calculation approach is applied to predict performance of a pilot-scale circulating fluidized bed (CFB) boiler at part load operation. Verification has been carried out by comparing between calculation results an operation data of the boiler.

  • PDF

부하추종 운전방법에 따른 고체산화물 연료전지/가스터빈 하이브리드 동력 시스템의 부분부하 성능특성 (Part-load Performance Characteristics of a Solid Oxide Fuel Cell/Gas Turbine Hybrid Power System Operating with Various Load-following Operation Modes)

  • 김재훈;양진식;노승탁;손정락
    • 대한기계학회논문집B
    • /
    • 제30권3호
    • /
    • pp.193-200
    • /
    • 2006
  • The purpose of this study is to compare the part-load performance of a SOFC/GT hybrid power system with three different kinds of load-following operation modes. The primary mode for the part load operation of a hybrid power system is the reduction of supplied fuel (e.g., fuel control mode) to the hybrid system. The other two options, i.e., variable speed and VIGV controls, are related to the reduction of supplied air simultaneously with the reduction of supplied fuel to the system. With the performance analysis of a SOFC/GT hybrid power system, it is concluded that the variable speed con佐ol mode Provides the best performance for the part-load operations. It is also found that the VIGV control mode, with its better performance behavior than the fuel control mode, can be used as an important option for the part-load operation especially in case that the variable speed control mode can not be adopted.

배열회수보일러의 부분부하 운전에 따른 유동불균일이 과열기의 성능에 미치는 영향 (Effect on Thermal Performance of Superheater Module under Part Load Operation in HRSG)

  • 정재헌;송정일
    • 에너지공학
    • /
    • 제17권3호
    • /
    • pp.161-166
    • /
    • 2008
  • 본 논문은 배열회수보일러에서 부분부하 운전이 과열기 열성능에 미치는 영향을 조사하였다. 첫 단계로 가스터빈 최대부하와 부분부하 운전시 배열회수보일러 형태에 따른 가스터빈 배가스의 유동 특성을 전산유체해석을 통해 조사하였다. 다음으로는 수직형 배열회수보일러 과열기 튜브관군의 가스터빈 최대부하와 부분부하 운전 시 온도분포를 전산유동해석 결과를 이용해 계산하였으며, 이 결과와 실제 발전소 측정을 통해 획득한 온도분포 결과를 비교하였다. 마지막으로 부분부하 운전이 과열기 열성능에 미치는 영향을 살펴보았으며, 또한 부분부하 운전시에 유동의 불균일 현상을 제거할 수 있는 장치를 고안하였다.

사무소 건물에서 냉동기의 부분부하율 및 냉방 에너지 성능 특성 분석 (A Detailed Analysis of the Part Load Ratio and Cooling Energy Characteristics of Chiller Operation in an Office Building)

  • 서병모;유병호;이광호
    • 설비공학논문집
    • /
    • 제27권11호
    • /
    • pp.567-573
    • /
    • 2015
  • Commercial buildings account for significant portions of the total building energy in Korea, and thus, a variety of research on chiller operation has been carried out. However, most of the studies were carried out on the chiller itself, i.e., the part load ratio characteristics and the corresponding electricity energy consumption patterns were not analyzed in existing studies. In this study, the part load ratio and the operating characteristics of the vapor compression chiller were analyzed within an office building equipped with the conventional variable air volume system. As a result, significant portions of total operating hours, cooling load, and energy consumption turned out to be in the part load ratio range of 0 through 50%. Thus, energy consumption was significantly affected by the chiller COP at low part load conditions, indicating that chiller operation at the part load is an important factor in commercial buildings.

수소추출기의 부분부하 운전을 위한 PSA 제어전략에 대한 연구 (A Study on PSA Controll Strategy for Part Load Operation of a Hydrogen Generator)

  • 이상호;김선엽;최영
    • 한국수소및신에너지학회논문집
    • /
    • 제33권6호
    • /
    • pp.819-826
    • /
    • 2022
  • Fuel cell systems are being supplied to households and buildings to reduce greenhouse gases. The fuel cell systems have problems of high cost and slow startup due to fuel processors. Greenhouse gas reduction of the fuel cell systems is also limited by using natural gas. The problems can be solved by using a hydrogen generator consisting of a reformer and pressure swing adsorption (PSA). However, part load operation of the hydrogen generator is required depending on the hydrogen consumption. In this paper, PSA operation strategies are investigated for part load of the hydrogen generator. Adsorption and purge time were changed in the range of part load ratio between from 0.5 to 1.0. As adsorption time increased, hydrogen recovery increased from 29.09% to 48.34% at 0.5 of part load ratio. Hydrogen recovery and hydrogen purity were also improved by increasing adsorption and purge time. However, hydrogen recovery dramatically decreased to 35.01% at 0.5 of part load ratio.

하이브리드형 고분자전해질 연료전지 시스템의 부분부하 성능해석 (Analysis of Part Load Performance of a Hybrid PEMFC System)

  • 지승원;유병준;김동섭;손정락;이영덕;안국영
    • 대한기계학회논문집B
    • /
    • 제32권11호
    • /
    • pp.849-855
    • /
    • 2008
  • The paper addresses modeling and analysis of the part load performance of a hybrid fuel cell system integrating a polymer electrolyte membrane fuel cell(PEMFC) and a gas turbine(GT). The system is a pressurized one where the working pressure of the PEMFC is higher than the ambient pressure. In addition to the two major components, the system also includes auxiliary parts such as a steam reformer, a humidifier, and afterburner and so on. Based on design analysis, component off-design models are incorporated in the analysis program and part load operation is simulated. The mode for the part load operation of the PEMFC/GT hybrid system is a variable rotational speed operation. The operating characteristics and variations in the system efficiency and component performance parameters at part load are analyzed.

마이크로 가스터빈의 탈설계 운전 성능특성 (Performance Characteristics for Off-design Operation of Micro Gas Turbines)

  • 김동섭;황성훈
    • 한국유체기계학회 논문집
    • /
    • 제7권3호
    • /
    • pp.39-47
    • /
    • 2004
  • Micro gas turbines are designed with low turbine inlet temperature and pressure ratio. To overcome the efficiency defect of the simple cycle, adoption of the recuperator is an inevitable choice. In addition to the design performance, we should also pay attention to the off-design performance of gas turbines since they usually operate at part-load conditions lot a considerable amount of their lifetime. This study analyzes off-design performance characteristics of micro gas turbines and addresses the importance of the recuperation process doting the part load operation. Comparative analyses have been performed to evaluate the part load performance differences among various design and operating options : simple vs recuperative cycles, single vs two shaft configurations, various operating strategies for the single shaft configuration, and current vs advanced engines. Major finding is that maintaining high turbine exhaust temperature is crucial for efficient operation of micro gas turbines.

마이크로 가스터빈의 탈설계 운전 성능특성 (Performance Characteristics for Off-design Operation of Micro Gas Turbines)

  • 황성훈;김동섭
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.80-87
    • /
    • 2003
  • Micro gas turbines are designed with low turbine inlet temperature and pressure ratio. To overcome the efficiency defect of the simple cycle, adoption of the recuperator is an inevitable choice. In addition to the design performance, we should also pay attention to the off-design performance of gas turbines since they usually operate at part-load conditions for a considerable amount of the time. This study aims at analyzing off-design performance characteristics of micro gas turbines and addressing the importance of the recuperator in the part load operation. Comparative analyses have been performed to evaluate the part load performance differences among various design and operating options : simple vs recuperative cycles, single vs two shaft configurations, various operating strategies for the single shaft configuration (fuel only control, variable speed operation, variable inlet guide vane control), and current vs advanced engines. Major finding is that maintaining turbine at high level is crucial in efficient operation of micro gas turbines.

  • PDF

커먼레일 디젤엔진 발전기의 연소상태 개선에 따른 연비절감을 위한 수치해석 (Numerical Analysis for Reduction of Fuel Consumption by Improvement of Combustion Condition in a Common Rail Diesel Engine Generator)

  • 김승철;김청균
    • 한국가스학회지
    • /
    • 제20권4호
    • /
    • pp.58-64
    • /
    • 2016
  • 차량에 사용되는 주엔진은 부하영역 전체에서 효율을 증가시키기 위해 커먼레일 디젤엔진을 사용하고 있다. 그러나, 발전기용 엔진은 아직도 기계적 구성엔진으로 캠으로 구동되는 연료분사밸브가 사용되어지고 있다. 또한, 발전기용 엔진 대부분은 50%이하의 부분부하가 적용되고 있다. 따라서, 전부하에 세팅된 차량용 디젤엔진을 부분부하에서 효율적인 운전을 하기 위해서는 연료분사시기 재조정이 필요하다. 본 연구에서는 시설물에 사용되는 엔진발전기의 운용특성을 파악하여 연료분사시기를 재조정함으로서 부분부하 연료소비율을 개선시킨 결과를 연구하고자 한다.

가스터빈 열병합발전 시스템의 설계점 설정 및 부분부하 성능해석 (Analysis of Design and Part Load Performance for gas Turbine Cogeneration Systems)

  • 김동섭;노승탁
    • 대한기계학회논문집
    • /
    • 제18권8호
    • /
    • pp.2167-2176
    • /
    • 1994
  • This paper presents some useful design criteria for the turbine cogeneration system through both the design and off-design analysis. Comparative analysis of the part load performance is carried out for several gas turbines which have different design parameters represented by the turbine inlet temperature and pressure ratio. It is shown that the variation in part load efficiency considerably depends on the design parameter. The off-design operation of the heat recovery steam generator is simulated by introducing adequate assumptions for the heat transfer process. It is turned out that the design parameters of heat recovery steam generator should be determined by considering the favorable operation at the off-design conditions.