• Title/Summary/Keyword: Parotid gland sparing

Search Result 6, Processing Time 0.023 seconds

Parotid gland sparing effect by computed tomography-based modified lower field margin in whole brain radiotherapy

  • Cho, Oyeon;Chun, Mison;Park, Sung Ho;Oh, Young-Taek;Kim, Mi-Hwa;Park, Hae-Jin;Nam, Sang Soo;Heo, Jaesung;Noh, O Kyu
    • Radiation Oncology Journal
    • /
    • v.31 no.1
    • /
    • pp.12-17
    • /
    • 2013
  • Purpose: Parotid gland can be considered as a risk organ in whole brain radiotherapy (WBRT). The purpose of this study is to evaluate the parotid gland sparing effect of computed tomography (CT)-based WBRT compared to 2-dimensional plan with conventional field margin. Materials and Methods: From January 2008 to April 2011, 53 patients underwent WBRT using CT-based simulation. Bilateral two-field arrangement was used and the prescribed dose was 30 Gy in 10 fractions. We compared the parotid dose between 2 radiotherapy plans using different lower field margins: conventional field to the lower level of the atlas (CF) and modified field fitted to the brain tissue (MF). Results: Averages of mean parotid dose of the 2 protocols with CF and MF were 17.4 Gy and 8.7 Gy, respectively (p < 0.001). Mean parotid dose of both glands ${\geq}20$ Gy were observed in 15 (28.3%) for CF and in 0 (0.0%) for MF. The whole brain percentage volumes receiving >98% of prescribed dose were 99.7% for CF and 99.5% for MF. Conclusion: Compared to WBRT with CF, CT-based lower field margin modification is a simple and effective technique for sparing the parotid gland, while providing similar dose coverage of the whole brain.

Whole brain radiotherapy using four-field box technique with tilting baseplate for parotid gland sparing

  • Park, Jaehyeon;Yea, Ji Woon
    • Radiation Oncology Journal
    • /
    • v.37 no.1
    • /
    • pp.22-29
    • /
    • 2019
  • Purpose: The aim of this study is to evaluate the efficacy and feasibility of four-field box whole brain radiotherapy (FB-WBRT) with tilting baseplate by comparing bilateral WBRT (B-WBRT). Methods and Materials: Between March 2016 and September 2018, 20 patients with brain metastases underwent WBRT using the four-field box technique. WBRT is performed with a dose of 30 Gy in 10 fractions daily. Two computed tomography simulations per person were performed. One was in the traditional supine position for B-WBRT and the other by applying the tilting acrylic supine baseplate to elevate the head by 40° for FB-WBRT. The B-WBRT used the field-in-field technique, which is the most commonly used method in our institution. The FB-WBRT comprised anterior, posterior, and bilateral beams. A wedge was applied in anterior and posterior fields to compensate for skull convexity. Results: The average of Dmean of both parotid glands was 10.2 Gy (range, 3.8 to 17.8 Gy) in B-WBRT and 5.4 Gy (range, 2.0 to 11.7 Gy) in FB-WBRT (p < 0.05). Compared to B-WBRT, FB-WBRT reduced the mean dose of the right and left parotid glands from 10.1 Gy to 4.9 Gy and from 10.4 Gy to 5.8 Gy, respectively (p < 0.05). Further, V5, V10, V15, V20, and V25 for the parotid gland decreased significantly in FB-WBRT (p < 0.05). The Dmax and Dmean of lens decreased according to the dose-volume histogram. Conclusion: Compared to B-WBRT, FB-WBRT with a tilting baseplate is a simple and effective method that takes feature of noncoplanar beam to protect the parotid gland.

Non-coplanar whole brain radiotherapy is an effective modality for parotid sparing

  • Park, Jaehyeon;Park, Jae Won;Yea, Ji Woon
    • Journal of Yeungnam Medical Science
    • /
    • v.36 no.1
    • /
    • pp.36-42
    • /
    • 2019
  • Background: The purpose of this study was to evaluate the efficacy and feasibility of non- coplanar whole brain radiotherapy (NC-WBRT) for parotid sparing. Methods: Fifteen cases, previously treated with WBRT were selected. NC-WBRT plans were generated. The beam arrangement for the non-coplanar plans consisted of superior anterior, right, and left beams. After generation of the non-coplanar plans a field-in-field technique was applied to the bilateral parallel opposed beams in order to reduce maximum dose and increase dose homogeneity. The NC-WBRT plans were subsequently compared with the previously generated bilateral WBRT (B-WBRT) plans. A field-in-field technique was also used with the B-WBRT plans according to our departmental protocol. As per our institutional practice a total dose of 30 Gy in 10 fractions of WBRT was administered 5 days a week. Results: The mean dose to the parotid gland for the two different plans were 16.2 Gy with B-WBRT and 13.7 Gy with NC-WBRT (p<0.05). In the NC-WBRT plan, the V5Gy, V10Gy, V15Gy, V20Gy, and V25Gy of the parotid were significantly lower (p<0.05) than those of the B-WBRT plan. The $D_{max}$ of the lens was also lower by 10% with NC-WBRT. Conclusion: The use of NC-WBRT plans could be a simple and effective method to reduce irradiated volumes and improve the dose-volume parameters of the parotid gland.

Parotid Gland Sparing Radiotherapy Technique Using 3-D Conformal Radiotherapy for Nasopharyngeal CarcinomB (비인강암에서 방사선 구강 건조증 발생 감소를 위한 3차원 입체조형치료)

  • Lim Jihoon;Kim Gwi Eon;Keum Ki Chang;Suh Chang Ok;Lee Sang-wook;Park Hee Chul;Cho Jae Ho;Lee Sang Hoon;Chang Sei Kyung;Loh Juhn Kyu
    • Radiation Oncology Journal
    • /
    • v.18 no.1
    • /
    • pp.1-10
    • /
    • 2000
  • Purpose : Although using the high energy Photon beam with conventional Parallel-opposed beams radiotherapy for nasopharyngeal carcinoma, radiation-induced xerostomia is a troublesome problem for patients. We conducted this study to explore a new parotid gland sparing technique in 3-D conformal radiotherapy (3-D CRT) in an effort to prevent the radiation-induced xerostomia. Materials and Methods : We peformed three different planning for four clinically node-negative nasopharyngeal cancer patients with different location of tumor(intracranial extension, nasal cavity extension, oropharyngeal extension, parapharyngeal extension), and intercompared the plans. Total prescription dose was 70.2 Gy to the isocenter. For plan-A, 2-D parallel opposing fields, a conventional radiotherapy technique, were employed. For plan-B, 2-D parallel opposing fields were used up until 54 Gy and afterwards 3-D non-coplanar beams were used. For plan-C, the new technique, 54 Gy was delivered by 3-D conformal 3-port beams (AP and both lateral ports with wedge compensator; shielding both superficial lobes of parotid glands at the AP beam using BEV) from the beginning of the treatment and early spinal cord block (at 36 Gy) was peformed. And bilateral posterior necks were treated with electron after 36 Gy. After 54 Gy, non-coplanar beams were used for cone-down plan. We intercompared dose statistics (Dmax, Dmin, Dmean, D95, DO5, V95, VOS, Volume receiving 46 Gy) and dose volume histograms (DVH) of tumor and normal tissues and NTCP values of parotid glands for the above three plans. Results : For all patients, the new technique (plan-C) was comparable or superior to the other plans in target volume isodose distribution and dose statistics and it has more homogenous target volume coverage. The new technique was most superior to the other plans in parotid glands sparing (volume receiving 46 Gy: 100, 98, 69$\%$ for each plan-A, B and C). And it showed the lowest NTCP value of parotid glands in all patients (range of NTCP; 96$\~$100$\%$, 79$\~$99$\%$, 51$\~$72$\%$ for each plan-A, B and C). Conclusion : We conclude that the new technique employing 3-D conformal radiotherapy at the beginning of radiotherapy and cone down using non-coplanar beams with early spinal cord block is highly recommended to spare parotid glands for node-negative nasopharygeal cancer patients.

  • PDF

Evaluation of Xerostomia Following Intensity Modulated Radiotherapy (IMRT) for Head and Neck Cancer Patients (세기조절방사선치료를 시행받은 두경부암 환자군에서 구강건조증지표 분석)

  • Lee, Seok-Ho;Kim, Tae-Hyun;Chie, Eui-Kyu;Im, Hyun-Shun;Im, En-Shil;Ryu, Jun-Sun;Jung, Yoo-Seok;Park, Sung-Yong;Kim, Joo-Young;Pyo, Hong-Ryull;Shin, Kyung-Hwan;Kim, Dae-Yong;Cho, Kwan-Ho
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.106-114
    • /
    • 2004
  • Purpose : This study was done to evaluate xerostomia fellowing intensity modulated radiotherapy for patients with head and neck cancer, and to analyze the correlation between the dosimetric parameters and xerostomia parameters. Materials and Methods : From February till October 2003, 13 patients with 3 months of follow-up were evaluated for xerostomia after being treated for head and neck cancer with IMRT. Their median age was 57 years(range: 43$\~$77). Xerostomia were assessed with a 4-question xerostomia questionnaire score (XQS) and a test for salivary flow rates (unstimulated and stimulated). The patients were also given a validated LENT SOMA scale (LSC) questionnaire. The evaluations were completed before radiation therapy (pre-RT) and at 1 and, 3 months after radiation therapy (RT). We evaluated xerostomia at pre-RT, 1 and, 3 months after RT. The association between the xerostomia parameters (XQS and LSC) and salivary flow rates (unstimulated and stimulated: USFR and SSFR) was assessed at 1 and 3 months after RT. Resrlts : All 13 patients showed no significant changes in XQS, LSC and Salivary Flow rates. As a result, we couldn't find out about xerostomia development. Based on the total mean parotid dose, 3,500 cGy, we divided these patients into two groups. The 8 patients (<3,500 cGy) showed no significant changes in XQS, LSC and Salivary Flow rates However, in 5 Patients ($\geq$3,500 cOGy), there was a significant increase in USFR and, SSFR at 3 months after RT, and for the XQS and, LSC at 1 and 3 months after RT. The correlation between XQS and, LSC, and USFR and, SSFR in ail patients (13) was significant at 3 months after RT. The correlation had a tendency to the decrease for USFR and, SSFR in proportion to the increase of XQS and, LSC. Conclusion : Based on the results of this study, IMRT seem to be an effective treatment to significantly decrease the xerostomia. XQS and, LSC seem to be a effective tool for predicting the xerostomia. A total parotid gland mean dose of <3,500 cGy should be a planning goal if substantial sparing of the gland function is desired. Furthermore, patients should be enrolled in a study to define a more accurate threshold dose for the parotid gland.

'Simultaneous Modulated Accelerated Radiation Therapy' (SMART) Intensity-Modulated Radiotherapy in the Treatment of Nasopharyngeal Carcinoma : the Asan Medical Center (비인강암의 세기조절방사선치료기술을 이용한 동시차등조사가속치료의 예비성적)

  • Lee Sang-Wook;Back Geum-Mun;Yi Byong-Yong;Choi Eun-Kyung;Kim Jong-Hoon;Ahn Seung-Do;Shin Seong-Soo;Kim Sang-Yoon;Nam Soon-Yuhl;Choi Seung-Ho;Kim Sung-Bae;Song Si-Yeol
    • Korean Journal of Head & Neck Oncology
    • /
    • v.19 no.1
    • /
    • pp.9-15
    • /
    • 2003
  • Purpose: To introduce our early experience with intensity-modulated radiotherapy (IMRT) in the treatment of nasopharyngeal carcinoma. Methods and Materials: Eight patients who underwent IMRT for no disseminated nasopharyngeal carcinoma at the Asan Medical Center between September 2001 and November 2002 were evaluate by prospective analysis. According to the 1997 American Joint Committee on Cancer staging classification, 5 had Stage III, and 3 had Stage IVB disease. The IMRT plans were designed to be delivered as a 'Simultaneous Modulated Accelerated Radiation Therapy' (SMART) using the 'step and shoot' technique with a MLC (multileaf collimator). Daily fractions of 2.2-2.5Gy and 1.9-2Gy were prescribed and delivered to the GTV and CTV and clinically negative neck node, respectively. The prescribed dose was 70A-79.0Gy to the gross tumor volume (GTV), 60Gy to the clinical target volume (CTV) and metastatic nodal station, and 46Gy to the clinically negative neck. All patients also received weekly cisplatin during radiotherapy. Acute and late normal tissue effects were graded according to the Radiation Therapy Oncology Group (RTOG) radiation morbidity scoring criteria. Results: Follow-up period was ranging from 5 to 18 months. All patients showed complete response and loco-regional control rate was 100% but one patient died of malnutrition due to treatment related toxicity. There were no Grade 3 or 4 xerostomia and all patients had experienced improvement of salivary gland function. Conclusion: 'Simultaneous Modulated Accelerated Radiation Therapy' (SMART) boost intensity-modulated radiotherapy technique allows parotid sparing as evidenced both clinically and by dosimetry. Initial tumor response and loco-regional control was promising. It is clinically feasible. A larger population of patients and a long-term follow-up are needed to evaluate ultimate tumor control and late toxicity.