• 제목/요약/키워드: Park Yoo-jeon

검색결과 321건 처리시간 0.028초

Sulfuretin Prevents Obesity and Metabolic Diseases in Diet Induced Obese Mice

  • Kim, Suji;Song, No-Joon;Chang, Seo-Hyuk;Bahn, Gahee;Choi, Yuri;Rhee, Dong- Kwon;Yun, Ui Jeong;Choi, Jinhee;Lee, Jeon;Yoo, Jae Hyuk;Shin, Donghan;Park, Ki-Moon;Kang, Hee;Lee, Sukchan;Ku, Jin-Mo;Cho, Yoon Shin;Park, Kye Won
    • Biomolecules & Therapeutics
    • /
    • 제27권1호
    • /
    • pp.107-116
    • /
    • 2019
  • The global obesity epidemic and associated metabolic diseases require alternative biological targets for new therapeutic strategies. In this study, we show that a phytochemical sulfuretin suppressed adipocyte differentiation of preadipocytes and administration of sulfuretin to high fat diet-fed obese mice prevented obesity and increased insulin sensitivity. These effects were associated with a suppressed expression of inflammatory markers, induced expression of adiponectin, and increased levels of phosphorylated ERK and AKT. To elucidate the molecular mechanism of sulfuretin in adipocytes, we performed microarray analysis and identified activating transcription factor 3 (Atf3) as a sulfuretin-responsive gene. Sulfuretin elevated Atf3 mRNA and protein levels in white adipose tissue and adipocytes. Consistently, deficiency of Atf3 promoted lipid accumulation and the expression of adipocyte markers. Sulfuretin's but not resveratrol's anti-adipogenic effects were diminished in Atf3 deficient cells, indicating that Atf3 is an essential factor in the effects of sulfuretin. These results highlight the usefulness of sulfuretin as a new anti-obesity intervention for the prevention of obesity and its associated metabolic diseases.

유수분리를 위한 3D 프린팅 기술 기반의 마이크로하이드로사이클론 (3D-Printed Microhydrocyclone for Oil/Water Separation)

  • 김주완;김원진;박승;박채리;유정흠;지인서;강전웅;김태영;홍지우
    • Korean Chemical Engineering Research
    • /
    • 제60권2호
    • /
    • pp.289-294
    • /
    • 2022
  • 생활 폐수나 산업 폐수에 포함된 오일이나 해양 유출유 등은 수질오염 및 생태계 파괴 등의 심각한 환경오염 문제를 야기하고 있다. 대표적인 유수분리기술인 필터(또는 멤브레인)를 사용하는 경우에 분리막의 파울링, 낮은 처리용량 등의 기술적 제약이 있다. 본 연구에서는 원심력을 이용하여 유체내의 입자상 물질이나 밀도가 다른 액체-액체 혼합물을 분리하는 장치인 하이드로사이클론의 장점을 활용하며, 동시에 분리 효율을 증대시키 위하여 고해상도의 3D 프린팅 기술을 도입하여 스케일 다운된 마이크로하이드로사이클론을 제작하였다. 본 연구에서 개발한 마이크로하이드로사이클론을 통해 탈이온수와 올리브유로 이루어져 있는 수중유상 에멀젼을 효과적으로 분리할 수 있음을 증명하였다.

Comparison of Digital PCR and Quantitative PCR with Various SARS-CoV-2 Primer-Probe Sets

  • Park, Changwoo;Lee, Jina;Hassan, Zohaib ul;Ku, Keun Bon;Kim, Seong-Jun;Kim, Hong Gi;Park, Edmond Changkyun;Park, Gun-Soo;Park, Daeui;Baek, Seung-Hwa;Park, Dongju;Lee, Jihye;Jeon, Sangeun;Kim, Seungtaek;Lee, Chang-Seop;Yoo, Hee Min;Kim, Seil
    • Journal of Microbiology and Biotechnology
    • /
    • 제31권3호
    • /
    • pp.358-367
    • /
    • 2021
  • The World Health Organization (WHO) has declared the coronavirus disease 2019 (COVID-19) as an international health emergency. Current diagnostic tests are based on the reverse transcription-quantitative polymerase chain reaction (RT-qPCR) method, which is the gold standard test that involves the amplification of viral RNA. However, the RT-qPCR assay has limitations in terms of sensitivity and quantification. In this study, we tested both qPCR and droplet digital PCR (ddPCR) to detect low amounts of viral RNA. The cycle threshold (CT) of the viral RNA by RT-PCR significantly varied according to the sequences of the primer and probe sets with in vitro transcript (IVT) RNA or viral RNA as templates, whereas the copy number of the viral RNA by ddPCR was effectively quantified with IVT RNA, cultured viral RNA, and RNA from clinical samples. Furthermore, the clinical samples were assayed via both methods, and the sensitivity of the ddPCR was determined to be equal to or more than that of the RT-qPCR. However, the ddPCR assay is more suitable for determining the copy number of reference materials. These findings suggest that the qPCR assay with the ddPCR defined reference materials could be used as a highly sensitive and compatible diagnostic method for viral RNA detection.

Maxillary Sinus Grafts for Endosseous Implant Placement: A Literature Review

  • Park, Seung-Byung;Kim, Su-Gwan;Baek, Sung-Moon;Ahn, Yu-Seok;Moon, Kyung-Nam;Jeon, Woo-Jin;Oh, Ji-Su;Lee, Jeong-Hoon;Im, Jae-Hyung;Yoo, Kyung-Hwan;Kim, Jin-Ha
    • Journal of Korean Dental Science
    • /
    • 제3권1호
    • /
    • pp.25-31
    • /
    • 2010
  • This study sought to evaluate the effect of the type of grafts used in sinus lifting. A review of literature through MEDLINE search covering the period 1980 ~ 2006 was performed. After screening, this study was narrowed down to 2,452 patients receiving sinus lift grafts wherein 7,151 implants were placed. In this study, the types of grafts used in sinus augmentation were autogenous bone, allogenic bone, corticocancellous block bone, and various alloplastic materials. The success rate varied from 69% to 100% depending on the graft material type. The highest success rate was reported for the autogenous bone, with high success rates recorded for the most part in most studies.

  • PDF

대면적 OLED 면광원을 위한 PEDOT : PSS 슬롯다이 코팅 (Slot-Die Coating of PEDOT : PSS for Large-Area OLED Lighting Sources)

  • 최광준;이진영;전경준;유수호;박종운;서화일;서유석
    • 반도체디스플레이기술학회지
    • /
    • 제14권1호
    • /
    • pp.61-65
    • /
    • 2015
  • We have fabricated poly(3,4-ethylenedioxythiophene) : poly(4-styrenesulfonate) (PEDOT : PSS) thin films using a slotdie coater for the applications of OLED lightings. It is demonstrated that the properties of slot-die coated PEDOT : PSS films are comparable with those of spin-coated ones. Namely, the average and peak-to-peak roughness of the slot-die coated 50-nm-thick PEDOT : PSS film are measured to be as low as 0.247 nm and 1.3 nm, respectively. Moreover, we have obtained excellent thickness uniformity (~1.91%). With the slot-die coated PEDOT : PSS films, we have fabricated green phosphorescent OLED devices. For comparison, we have also fabricated OLED devices with spin-coated PEDOT : PSS films. Both show almost no discrepancy in device performance. The power efficiency (25.4 lm/W) and emission uniformity (77%) of OLEDs with slot-die coated PEDOT : PSS films are shown to be slightly lower than those (27.3 lm/W, 80%) of OLEDs with spin-coated PEDOT : PSS films at the luminance of 1,000nit, increasing the feasibility of using a slot-die coating process for the fabrication of large-area OLED lighting sources at a competitive price.

당뇨환자에 있어서 녹용추출물의 섭취가 혈압, 혈당 및 임파구 DNA 손상에 미치는 영향 (Effect of Deer Antler Drink Supplementation on Blood Pressure, Blood Glucose and Lymphocyte DNA Damage in Type 2 Diabetic Patients)

  • 김혜영;전은재;박유경;강명희
    • Journal of Nutrition and Health
    • /
    • 제37권9호
    • /
    • pp.794-800
    • /
    • 2004
  • Deer Antler has been known for its traditional oriental medicinal properties and has been widely used to promote growth, boost immune function, treat blood loss and chronic joint pain. Recent study showed imported (New Zealand) Deer Antler was beneficial in reducing the side effects of cancer treatments. However, there was no intervention study conducted on the effect of Korean Deer Antler on reducing the oxidative stress to patients with diabetes. One of the sensitive ways to measure endogenous oxidative stress is by measuring cellular DNA damage using single cell gel electrophoresis (COMET assay). This study was conducted to investigate the possible beneficial effect of commercial Deer Antler drink (provided by Chung-yang Deer Farm) on lymphocyte DNA damage and blood glucose of diabetic patients. Ten patients (4 men, 6 women) participated in the study and consumed 2 pouches of Deer Antler drink every day for 20 days. Blood was collected on the morning before and after the intervention for lymphocyte isolation and blood glucose analysis. Both systolic and diastolic blood pressure showed a tendency to decrease but did not reach statistical significance after the trial. Blood glucose level was not affected by the supplementation. After the intervention, over 50% reduction were noted in the cellular DNA damage, expressed as tail length (TL) and tail moment (TM: tail length ${\times}$ percent tail DNA) . Although we did not obtain beneficial effect on lowering blood glucose levels in the patients, this results suggest that Deer Antler may initially act in protecting endogenous DNA damage in short-term experiment.

PMMA 유기 게이트 절연막의 농도와 두께에 따른 특성 (Properties of Organic PMMA Gate Insulator Film at Various Concentration and Film Thickness)

  • 유병철;공수철;신익섭;신상배;이학민;박형호;전형탁;장영철;장호정
    • 반도체디스플레이기술학회지
    • /
    • 제6권4호
    • /
    • pp.69-73
    • /
    • 2007
  • The MIM(metal-insulator-metal) capacitors with the Al/PMMA/ITO/Glass structures were manufactured according to various PMMA concentration of 1, 2, 4, 6, 8 wt%. The lowest leakage current and the largest capacitance were found to be 2.3 pA and 1.2 nF, respectively, for the device with 2 wt% PMMA concentration. The measured capacitance of the devices was almost same values with the calculated one. The optimum film thickness was obtained at the value of 48 nm, showing that the capacitance and leakage current were 1.92 nF, 0.3 pA at 2 wt%, respectively. From this experiment, the PMMA gate insulator films can be applicable to the organic thin film transistors.

  • PDF

MCM-41 촉매 합성법이 선형 저밀도 폴리에틸렌의 촉매 열분해 동역학에 미치는 영향 (Effect of MCM-41 Preparation Methods on the Kinetics of Catalytic Pyrolysis of Linear Low Density Polyethylene)

  • 박영권;김주식;전종기;임정은;김지만;유경선
    • 폴리머
    • /
    • 제29권2호
    • /
    • pp.122-126
    • /
    • 2005
  • Al-MCM-41의 제조방법이 선형 저밀도 폴리에틸렌(LLDPE)의 촉매 분해 활성에 어떠한 영향을 주는지 조사하였다 이를 위해 Al-MCM41은 직접 합성법(Al-MCM41-D)과 후처리법(Al-MCM-41-P)의 두 가지 방법으로 제조되었으며, XRD, BET, $NH_3\;TPD,\;^{27}Al$ MAS NMR 등을 이용하여 이들 촉매 특성을 규명하였다. TGA 동역학 방법을 사용하여 Al-MCM-41-D와 Al-MCM-41-P의 LLDPE촉매 분해 활성화 에너지를 구한 결과 각각 197.54, 174.26 kJ/mol로 나타났다. 이처럼 시-MCM-41-P가 시-MCM-41-D보다 촉매 활성이 높은 이유는 접근 가능한 산점수가 훨씬 많고 상대적으로 기공 크기도 작은 것에 기인한 것으로 여겨진다.

함치성 낭종의 조대술 후 미맹출 변위 영구치의 교정적 정출: 증례보고 (Forced Eruption of Severe Angulated and Impacted Permanent Teeth after Marsupialization of Dentigerous Cyst: Case Report)

  • 남정훈;노경록;유우근;이병민;전지현;박수현;안장훈;김정희
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제33권1호
    • /
    • pp.83-88
    • /
    • 2011
  • The goal of this treatment is the surgical-orthodontic eruption of impacted permanent teeth associated with a large dentigerous cyst in a preadolescent patient. Although enucleation of the entire cyst and the extraction of impacted teeth are common treatments, missing permanent teeth cause several problems in young patients. In this report, an 11-year-old female visited with the chief complaint of a large radiolucent lesion from the mandibular anterior area to the left mandibular posterior area. The permanent left canine and premolars were displaced toward the mandibular inferior border area. The extraction of infected deciduous teeth and marsupialization were performed. After 4 months, orthodontic buttons for forced eruption were applied to the impacted permanent teeth. The teeth emerged into the oral cavity 3 months after the orthodontic treatment. Although the root form was abnormal, there were no other pathogenic signs. The alveolar bone had a normal trabecular pattern and the teeth appeared to be well maintained at postoperative 24 months.

Synthesis of CaS:Eu2+ Phosphor by using a Sealing Vessel and its Photoluminescence Properties

  • Yoo, Hyoung-Sun;Park, Bong-Je;Kang, Jong-Hyuk;Im, Won-Bin;Jeon, Duk-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권6호
    • /
    • pp.255-259
    • /
    • 2007
  • We have synthesized $CaS:Eu^{2+}$ phosphor by using a sealing vessel and evaluated its photoluminescence properties. The method using a sealing vessel is simple and economical in comparison with other methods reported up to date. As an activator concentration was increased from 0.1 mol% to 4 mol%, the main emission wavelength of the phosphor was increased from 642 nm to 651 nm due to the crystal field splitting of 5d levels of $Eu^{2+}$ ion. Although the same amount of $Eu_2O_3$ was used, the concentration of the activator ions, which were reduced from $Eu^{3+}\;to\;Eu^{2+}$ and substituted $Ca^{2+}$ ions, was increased with increase of firing temperature. Therefore, the main emission wavelength was also. shifted from 645 nm to 651 nm with increase of firing temperature from $1100^{\circ}C\;to\;1300^{\circ}C$. The critical distance($R_{c1}=20.65\;{\AA}$) between $Eu^{2+}$ ions calculated from the critical concentration was well matched with that($R_{c2}=19.17\;{\AA}$) calculated from the Dexter formula.