• Title/Summary/Keyword: Park's Vector Method

Search Result 212, Processing Time 0.033 seconds

Study on Distortion Ratio Calculation of Park's Vector Pattern for Diagnosis of Stator Winding Fault of Induction Motor (유도전동기의 고정자 권선고장 진단을 위한 팍스벡터 패턴의 왜곡률 연산에 대한 연구)

  • Yang, Chul-Oh;Park, Kyu-Nam;Song, Myung-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.643-649
    • /
    • 2012
  • The diagnosis technique of stator winding faults based on Motor Current Signature Analysis(MCSA) was suggested. Park's vector pattern, the circle that is drawn by d-q transformed currents($i_d$, $i_q$), is widely used for stator winding faults detection. The current Distortion Ratio(DR), defined by the ratio of max axis and min axis of ellipse of Park's vector's pattern, was more simple and powerful method than the Park's vector pattern. In this study, a calculation method of distortion ratio of Park's vector pattern was suggested for auto diagnosis of stator winding short fault and usefulness of suggested calculation method of distortion ratio was verified through simulation using LabVIEW program.

Stator Winding Fault Diagnosis in Small Three-Phase Induction Motors by Park's Vector Approach (Park's Vector 기법을 이용한 소형 3상 유도 전동기의 권선 고장 진단)

  • 박규남;한민관;우혁재;송명현
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.6
    • /
    • pp.1291-1296
    • /
    • 2003
  • This paper deals with efficient diagnostic for stator winding fault of 3-phase induction motor using a current Park's vector approach. This method firstly transforms 3-phase stator current to vertical axis current and horizontal axis current of Park's Vector, and then obtains the each Park's Vector Pattern and detects stator winding fault by comparing to Park's Vector Pattern of healthy and fault. Experimental results, obtained by using induction motor having inter-turn fault of 2, 10, 20 turn, demonstrate the effectiveness of the proposed technique, for detecting the presence of stator winding fault under 25%, 50%, and 100% of full load condition.

A New Hybrid "Park's Vector - Time Synchronous Averaging" Approach to the Induction Motor-fault Monitoring and Diagnosis

  • Ngote, Nabil;Guedira, Said;Cherkaoui, Mohamed;Ouassaid, Mohammed
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.559-568
    • /
    • 2014
  • Induction motors are critical components in industrial processes since their failure usually lead to an unexpected interruption at the industrial plant. The studies of induction motor behavior during abnormal conditions and the possibility to diagnose different types of faults have been a challenging topic for many electrical machine researchers. In this regard, an efficient and new method to detect the induction motor-fault may be the application of the Time Synchronous Averaging (TSA) to the stator current Park's Vector. The aim of this paper is to present a methodology by which defects in a three-phase wound rotor induction motor can be diagnosed. By exploiting the cyclostationarity characteristics of electrical signals, the TSA method is applied to the stator current Park's Vector, allowing the monitoring of the induction motor operation. Simulation and experimental results are presented in order to show the effectiveness of the proposed method. The obtained results are largely satisfactory, indicating a promising industrial application of the hybrid Park's Vector-TSA approach.

Auto-Diagnosis for Stator Winding Faults Using Distortion Ratio of Park's Vector Pattern (Park's 벡터 패턴의 왜곡률을 이용한 고정자 권선 고장 자동진단)

  • Song, Myung-Hyun;Park, Kyu-Nam;Han, Dong-Gi;Yang, Chul-Oh
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.160-163
    • /
    • 2008
  • In this paper, an auto-diagnosis method of the stator winding fault for small induction motor is suggested. 3-phase stator currents are sampled, filtered, and transformed with Park's vector transformation. After then Park's vector patterns are obtained. To detect the stator winding fault automatically, a distortion ratio is newly defined and compared with the one of healthy motor, and the threshold levels of distortion ratio are suggested. The 2-turn, 4-turn, 8-turn winding fault are tested with no load, 25%, 50%, 75%, and 100% rated load. The distortion ratio of the Park's vector patterns are increased as the increase of the faulted turns, but are same as the increase of the load.

Auto-Detection of Stator Winding Fault of Small Induction Motor using LabVIEW (LabVIEW를 이용한 소형 유도전동기의 권선고장 자동진단)

  • Song, Myung-Hyun;Park, Kyu-Nam;Han, Dong-Gi;Woo, Hyeok-Jae
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.4
    • /
    • pp.202-206
    • /
    • 2006
  • In this paper, an auto detection method of stator winding fault of small induction motor is suggested. The Park's vector pattern which is obtained from 3-phase current signal by d-q transforming, is very good to detect winding fault. Comparing the Park's vector pattern of testing motor with its of healthy motor, the Park's vector pattern of fault motor is became an ellipse and the asymmetry is increased by the winding fault series. So for detecting the dis-symmetry, id-filtered function, Min-value, and Max-value are suggested for auto detecting. Using LabVIEW programing, 3-phase healthy motor and several kind of winding fault motors are tested and the test results are shown that the suggested method can gives us a possibility of an auto detecting winding fault.

A Stator Fault Diagnosis of an Induction Motor based on the Phase Angle of Park's Vector Approach (Park's Vector Approach의 위상각 변이를 활용한 유도전동기 고정자 고장진단)

  • Go, Young-Jin;Lee, Buhm;Song, Myung-Hyun;Kim, Kyoung-Min
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.4
    • /
    • pp.408-413
    • /
    • 2014
  • In this paper, we propose a fault diagnosis method based on Park's Vector Approach using the Euler's theorem. If we interpreted it as Euler's theorem, it is possible to easily find the phase angle difference between the healthy condition and the fault condition. And, we analyzed the variation of the phase angle and performed the diagnostic method of the induction motor using feature vectors that were obtained by using a Fourier transform. The analysis of time and speed variation of the motor was performed and, as a result, we could find more soft variations than rough variations. In particular, the analysis of the distortion through each phase shows that two-turn and four-turn shorted motors are linearly separable. In this experiment, we know that the maximum breakdown threshold value for determining steady-state fault detection is 49.0788. Simulation and experimental results show the more detectable than conventional method.

A Study on the Maximizing Coverage for Recommender System

  • Lee, Hee-Choon;Lee, Seok-Jun;Park, Ji-Won;Kim, Chul-Seoung
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.119-128
    • /
    • 2006
  • The similarity weight, the pearson's correlation coefficient, which is used in the recommender system has a weak point that it cannot predict all of the prediction value. The similarity weight, the vector similarity, has a weak point of the high MAE although the prediction coverage using the vector similarity is higher than that using the pearson's correlation coefficient. The purpose of this study is to suggest how to raise the prediction coverage. Also, the MAE using the suggested method in this study was compared both with the MAE using the pearson's correlation coefficient and with the MAE using the vector similarity, so was the prediction coverage. As a result, it was found that the low of the MAE in the case of using the suggested method was higher than that using the pearson's correlation coefficient. However, it was also shown that it was lower than that using the vector similarity In terms of the prediction coverage, when the suggested method was compared with two similarity weights as I mentioned above, it was found that its prediction coverage was higher than that pearson's correlation coefficient as well as vector similarity.

  • PDF

Diagnosis Method for Stator-Faults in Induction Motor using Park's Vector Pattern and Convolution Neural Network (Park's Vector 패턴과 CNN을 이용한 유도전동기 고정자 고장진단방법)

  • Goh, Yeong-Jin;Kim, Gwi-Nam;Kim, YongHyeon;Lee, Buhm;Kim, Kyoung-Min
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.883-889
    • /
    • 2020
  • In this paper, we propose a method to use PV(Park's Vector) pattern for inductive motor stator fault diagnosis using CNN(Convolution Neural Network). The conventional CNN based fault diagnosis method was performed by imaging three-phase currents, but this method was troublesome to perform normalization by artificially setting the starting point and phase of current. However, when using PV pattern, the problem of normalization could be solved because the 3-phase current shows a certain circular pattern. In addition, the proposed method is proved to be superior in the accuracy of CNN by 18.18[%] compared to the previous current data image due to the autonomic normalization.

A Study on Control Method for Built-in Type Spindle (Built-in Type 스핀들 구동을 위한 제어방법에 관한 연구)

  • Han S. Y.;Yoon J. M.;Park S. H.;Won C. Y.;Kim Y. R.;Choi C.;Lee S. H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.51-55
    • /
    • 2003
  • In this paper, the authors propose a new high performance Built-in Type spindle motor drive using vector-controlled technique at 15,000 r/min. Control method is changed by variation of motor speed in a conventional Built-in type spindle drive. In the drive system to be presented, the conventional vector control is used in the low-speed range, and the vector control without encoder is used in the high-speed range. Furthermore, in order to drive the motor from 0 to 15,000 rpm smoothly, the vector control with encoder in the low-speed range (from 0 to 8,000 rpm) is utilized and the vector control without encoder in the high-speed range (from 8,000 to 15,000 rpm) is utilized. This paper describes problem of control method in conventional spindle drive and proposes control method as variation of motor speed

  • PDF

A study on Sensorless Vector Control for Spindle Induction Motor (스핀들용 유도전동기 센서리스 벡터제어에 관한 연구)

  • Park, S.H.;Yoon, J.M.;You, J.S.;Shin, S.C.;Won, C.Y.;Choi, C.;Lee, S.H.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.119-124
    • /
    • 2004
  • A new control method of spindle induction motor drive is proposed in this paper. In a conventional control method, the vector control was employed in the low speed range, while the constant V/f(volt-per-hertz) PWM control was employed in the high speed range. The two control modes were automatically selected at an intermediate speed. In a proposed control method, the direct vector-control with an encoder is employed in the low speed range(from 0 to 8,000rpm), and the vector control without an encoder is employed in th high speed(from 8,000 to 15,000rpm) by using flux observer and speed estimator. This paper describes problem of control method in a conventional spindle induction motor drive and proposes contort method as variation of motor speed.

  • PDF