• Title/Summary/Keyword: Parametric Information

Search Result 742, Processing Time 0.025 seconds

A Study of New DC Pin-to-pin Parametric Test of VLSI Device using Communication (통신용 VLSI 소자의 새로운 편간 DC 파라메터 테스트 연구)

  • 박용수;유흥균
    • The Journal of Information Technology
    • /
    • v.2 no.2
    • /
    • pp.235-250
    • /
    • 1999
  • The test of digital VLSI devices is to insure that the device will perform all of its designed functions while in the worst-case environments. According to increasing the integration of the communication device, there are important consideration about the improvement of the reliability in the product. To improve the reliability of the device, the test parameters and test time are increased. There are basically three kinds of tests: functional, DC parametric, and AC parametric. There are no pin-to-pin short test and pin-to-pin leakage test in the present test items to analysis the characteristics and reliability of the device. The purpose of the paper is to model the pin-to-pin phenomenon and propose to modify the test method and to test the new pin-to-pin DC parameters. These modified and additive test items were applied to product test and confirmed to improve the reliability of product test.

  • PDF

Analysis of Highly Directional Sonar Communication System (고지향 소나 시스템 통신 성능분석)

  • Lee, Jaeil;Lee, Chong Hyun;Lee, Seung Wook;Shin, Jungchae;Jung, Jin Woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.3-9
    • /
    • 2012
  • In this paper, we present novel analysis results of sonar communication using parametric array. We consider transducer diameter, primary frequency, difference frequency and acoustic power as analysis parameters of communication performance. We calculate theoretical BER(Bit Error Rate) and channel capacity of MIMO(Multi Input and Multi Output) communication system. By considering practical parameters, we obtain optimum difference frequency generation condition. The obtained primary frequency is 560 kHz, difference frequency 45kHz and acoustic power is 28.05Watt. For BER of $10^{-4}$, the range gain of parametric array communication is 3.35km compared to primary frequency communication. For channel capacity of 10bps/Hz, the SISO and $2{\times}2$ MIMO communication range of parametric array communication are 3.8km and 3.98km respectively, while primary frequency communication range is 0.83km.

Power study for 4 × 4 graeco-latin square design (4 × 4 그레코라틴방격모형의 검정력 연구)

  • Choi, Young-Hun
    • Journal of the Korean Data and Information Science Society
    • /
    • v.23 no.4
    • /
    • pp.683-691
    • /
    • 2012
  • In $4{\times}4$ graeco-latin square design, powers of rank transformed statistic for testing the main effect are superior to powers of parametric statistic without regard to the effect structure with equally or unequally spaced effect levels as well as the type of population distributions such as exponential, double exponential, normal and uniform distribution. As numbers of block effect or effect sizes are decreased, powers of rank transformed statistic are much higher than powers of parametric statistic. In case that block effects are smaller than a main effect or one block effect is higher than other block effects, powers of rank transformed statistic are much higher than powers of parametric statistic in $4{\times}4$ graeco-latin square design with three block effects and one main effect.

A Restoration of Degraded Medicine Images Based on Optimized Parametric Wiener Filter (최적화된 매개변수 위너필터를 이용한 훼손된 의료영상의 복원)

  • Shin, Choong-Ho;Jung, Chai-Yeoung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.5
    • /
    • pp.1055-1063
    • /
    • 2012
  • The noise of image is added by many environmental factors. Therefore, we need to remove these noises using the conventional filtering methods, which are optimized based on the statistical characteristic of noise. In direct restoration method, there is an inverse filter and the wiener filter. Here, the wiener filter is the optimized filter in the view of least square method. First, we are going to study the inverse filter, wiener filter, constraint least square filter. Second, in order to control the quantity, we use the parameters instead of the power spectrum ratio. But, these parameters have the conflicting condition, therefore, we optimized the variables using parametric wiener filter which adjust the application appropriately. In the simulation results, the contrast of the degraded image was enhanced and the noise was removed. Comparative experimentation was demonstrated edge preserving and noise removing property.

Development of Automatic Drawing Program for Elevator Installation Drawing to Strengthen Competitiveness of The Elevator Industry (승강기 산업의 영업설계 경쟁력 강화를 위한 승강기 설치도면 자동생성 프로그램 개발)

  • Ko, Young-joon;Kim, Byoung-ik;Han, Kwan-hee
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.2
    • /
    • pp.172-179
    • /
    • 2019
  • Recently, design automation of installation drawings and design elements has been required in the elevator industry. This is recognized as an important role in securing adaptability on site, reducing design errors, and enhancing export competitiveness. However, in case of a small company doesn't have enough resources to develop the program, and it is difficult to develop a design automation program. Therefore, it is necessary to have an automatic drawing generation program that enables small companies to easily invest and use, while allowing users to concentrate on productive tasks. In this paper, we propose an automatic drawing generation program using parametric coding technique. This program is linked with the web service and automatically creates the drawing when the user enters the site information on the web. This is useful for elevator installation and maintenance due to reduced drawing time for elevator drawings.

A Study on the Establishment of Rule-Based Modules for Automating the Design of Interior Finishes in Architectural Buildings (건축 내부 마감 자동 상세화를 위한 규칙 기반 모듈 구축 방안에 관한 연구 - 바닥, 벽 및 천장을 중심으로 -)

  • Ha, Dae-Mok;Yu, Young-Su;Koo, Bon-Sang
    • Journal of KIBIM
    • /
    • v.12 no.1
    • /
    • pp.42-54
    • /
    • 2022
  • BIM facilitates data transparency and consistency through three-dimensional parametric modeling and promotes the accurate managing and sharing of project information. In Korea, however, BIM-based detailed design of architectural interior finishes required during the Construction Documents phase increases the burden on architectural firms due to frequent design changes and manual workload. Therefore, the purpose of this study was to establish rule-based modules using parametric modeling that automates repetitive tasks that occur during the detailed design of interior finishing. Interviews with practitioners were conducted to analyze the major finishing elements. Of these floors, walls, and ceilings, which were the most rudimentary and common items, were selected as the subjects of the study. The modules developed in this study have two functions. One is to create new finish types, and the other is the automatic modeling of new types into rooms. For these functions, parameters that belonged to each finish and room element in a BIM model were analyzed and valid parameters directly used for parametric modeling were derived. Then, based on these parameters, rule-based modules for three elements, I.e., floors, walls, and ceilings were constructed with Revit Dynamo, and the effectiveness of the modules was verified with a pilot test. In conclusion, this study suggested a series of processes for automatic finishing to improve the efficiency of BIM-based architectural detailed design of finishes and to contribute in solving the chronic problems occuring during current design processes.

Bootstrap tack of Fit Test based on the Linear Smoothers

  • Kim, Dae-Hak
    • Journal of the Korean Data and Information Science Society
    • /
    • v.9 no.2
    • /
    • pp.357-363
    • /
    • 1998
  • In this paper we propose a nonparametric lack of fit test based on the bootstrap method for testing the null parametric linear model by using linear smoothers. Most of existing nonparametric test statistics are based on the residuals. Our test is based on the centered bootstrap residuals. Power performance of proposed bootstrap lack of fit test is investigated via Monte carlo simulation.

  • PDF

Truncated Point and Reliability in a Right Truncated Rayleigh Distribution

  • Kim, Joong-Dae
    • Journal of the Korean Data and Information Science Society
    • /
    • v.17 no.4
    • /
    • pp.1343-1348
    • /
    • 2006
  • Parametric estimation of a truncated point in a right truncated Rayleigh distribution will be considered. The MLE, a bias reduced estimator and the ordinary jackknife estimator of the truncated point in the right truncated Rayleigh distribution will be compared by mean square errors. And proposed estimators of the reliability in the right truncated Rayleigh distribution will be compared by their mean squared errors.

  • PDF

Formation of MgO Thick Film Layer for AC-PDP via Electrophoresis Deposition of Nano-sized MgO Powders

  • Ko, Min-Soo;Kim, Yong-Seog
    • Journal of Information Display
    • /
    • v.8 no.2
    • /
    • pp.25-31
    • /
    • 2007
  • MgO thick film for ac-PDPs was formed via electrophoresis deposition process and its effect on luminance and luminance efficiency were evaluated. The electrophoresis deposition process of MgO thick film was optimized through parametric study and defects levels in MgO powders was evaluated using cathodoluminescence spectra measurements. The results demonstrate a possibility of using MgO thick film as electron emission layer for ac-PDPs.

Statistical Discriminant Analysis on the Driving Ability of the Brain-injured

  • Kim, Jae-Hee;Kim, Jeong-A
    • Journal of the Korean Data and Information Science Society
    • /
    • v.16 no.1
    • /
    • pp.19-31
    • /
    • 2005
  • Brain injured patients who had the driver's license before the injury of the brain were tested with the newly developed tool CPAD by Hangyang Medical School and the National Rehabilitation Center. The CPAD contains many variables to measure the ability of driving. Also for each patient the American standard CBDI score was measured and the result was compared with the CPAD results. Of interest is to classify the patients as pass, border, fail group after the CPAD test. To derive the discriminant functions with the group information based on CBDI, parametric/nonparametric and multivariate/univariate discriminant analysis was performed and discussed.

  • PDF