• 제목/요약/키워드: Parametric Evaluation

검색결과 404건 처리시간 0.026초

간이 모델을 이용한 헤밍 공정 변수 연구 및 헤밍 품질 평가 (Parametric Study of Hemming Process and Evaluation of Hem Quality Using Simple Models)

  • 최원목;임재규;박춘달;김형종
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 추계학술대회논문집
    • /
    • pp.113-116
    • /
    • 2003
  • Hem quality can be determined mainly by turn-down and roll-in. Turn-down, that is created by the elastic recovery, can't be easily detected and measured since it is usually as small as 0.03 m. This study is focused on the precise evaluation of the hemming defects through analytical and experimetal approaches, and on the investigation of the influence of process parameters on the final hem quality. Implicit finite element analysis of plane-strain hemming process is performed by using a commercial code ABAQUS/Standard. Experiment and measurement is also carried out for steel and aluminium sheet metals, and the results are compared with those of analysis.

  • PDF

객체지향 3D캐드를 이용한 공동주택 환경(일조, 조망)분석에 관한 디지털적 분석방법 연구 (A Study on the Analysis of Residential Environment based on Object-oriented 3D CAD System)

  • 유정원
    • 한국디지털건축인테리어학회논문집
    • /
    • 제5권2호
    • /
    • pp.9-14
    • /
    • 2005
  • The analysis system has been needed to pre-evaluate and analyze the right for sunlight and the right for view in a residential environment since the urban high density and high rise residentinal building types have been prevailing these days. The purpose of this study is to propose an digital analysis method to evaluate sunlight and view conditions in a residential environment to improve the system performance in the sense of speed and accuracy. The digital analysis method using the object-oriented 3D CAD system and parametric library is studied and applied in the system and the various outputs of the analysis system makes possible to modify the design with the speed and accuracy as a result of the analysis. The study includes the evaluation for a daylight and view condition of each unit, and the interruption degree to a vicinity environment in terms of sunlight and view conditions comparing before and after construction.

  • PDF

Extended Fuzzy DEA

  • Guo, Peijun;Tanaka, Hideo
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1998년도 The Third Asian Fuzzy Systems Symposium
    • /
    • pp.517-521
    • /
    • 1998
  • DEA(data envelopment analysis) is a non-parametric technique for measuring and evaluating the relative efficiencies of a set of entities with common crisp inputs and outputs. In fact, in a real evaluation problem input and output data of entities often flucturate. These fluctuating data can be represented as linguistic variables characterized by fuzzy numbers. Based on a fundamental CCR model, a fuzzy DEA model is proposed to deal with fuzzy input and output data, Furthermore, a model that extends a fuzzy DEA to a more general case is also proposed with considering the relation between DEA and RA (regression analysis) . the crisp efficiency in CCR modelis extended to an L-R fuzzy number in fuzzy DEA problems to reflect some uncertainty in real evaluation problems.

  • PDF

Rapid evaluation of in-plane seismic capacity of masonry arch bridges through limit analysis

  • Breccolotti, Marco;Severini, Laura;Cavalagli, Nicola;Bonfigli, Federico M.;Gusella, Vittorio
    • Earthquakes and Structures
    • /
    • 제15권5호
    • /
    • pp.541-553
    • /
    • 2018
  • In this paper a limit analysis based procedure for the rapid evaluation of the in-plane seismic capacity of masonry arch bridges is carried out. Attention has been paid to the effect of the backfill on the collapse load. A parametric investigation has been performed by varying the rise/span ratio and the results have been compared with those obtained by finite element modelling. The comparison highlights the conservative feature of the proposed model in terms of ultimate loads and a good agreement in terms of collapse mechanisms.

몬테카를로 방법에 의한 제어기의 강건성 해석 (A analysis of the robustness of a controller by Monte-Carlo method)

  • 정우용;홍성경;김종성
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.630-635
    • /
    • 1993
  • In this paper, the Monte-Carlo method was applied to the controller robustness evaluation problems with respect to the uncertainty of critical plant parameters. The plant studied is a aerial vehicle. The-variable parameters are nondimensional stability derivatives, inertias. The nominal nondimensional stability derivatives ,were obtained from wind tunnel test. Also the nominal inertia parameters were calculated from the mass distribution along the vehicle axes. But the parameters obtained from the test or calculations are at best probable and always contain some uncertainties which one can not figure out. So some kinds of robustness evaluation method should be applied. The parametric robustness of the designed classical controller evaluated by the method turned out to be satisfactory.

  • PDF

냉방열원의 경제성 평가를 위한 건물에너지 회귀식 산출 (Energy Regression Analysis for Economic Evaluation of Cooling Plants)

  • 김영섭;김강수
    • 설비공학논문집
    • /
    • 제14권5호
    • /
    • pp.377-384
    • /
    • 2002
  • For economic evaluation of cooling plant equipments, it is necessary to simplify energy Prediction method, which should includes efficiency corrected by part-load ratio. This study proposed simplified method with regression equations of time-average partial loads and refrigerator capacity. DOE-2 Program was used to carry out a parametric study of twelve design variables. Five input variables were considered to be significant and were used in the regression equations. To test accuracy of simplified method, calculated results were compared with DOE-2 simulated results. Test result showes a good agreement with the simulation result with an error of 5.9∼7.6%. It is expected that this method can be used as an easy prediction tool for comparing energy use of different cooling plants during the early design stage.

Stochastic analysis of a non-identical two-unit parallel system with common-cause failure, critical human error, non-critical human error, preventive maintenance and two type of repair

  • El-Sherbeny, M.S.
    • International Journal of Reliability and Applications
    • /
    • 제11권2호
    • /
    • pp.123-138
    • /
    • 2010
  • This paper investigates a mathematical model of a system composed of two non-identical unit parallel system with common-cause failure, critical human error, non-critical human error, preventive maintenance and two type of repair, i.e. cheaper and costlier. This system goes for preventive maintenance at random epochs. We assume that the failure, repair and maintenance times are independent random variables. The failure rates, repair rates and preventive maintenance rate are constant for each unit. The system is analyzed by using the graphical evaluation and review technique (GERT) to obtain various related measures and we study the effect of the preventive maintenance preventive maintenance on the system performance. Certain important results have been derived as special cases. The plots for the mean time to system failure and the steady-state availability A(${\infty}$) of the system are drawn for different parametric values.

  • PDF

직접변위설계법을 이용한 건축물의 지진응답 산정 (Seismic performance evaluation of a building structure using direct displacement-based design method)

  • 김진구;방성혁
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.569-576
    • /
    • 2001
  • In this study a procedure for evaluation of performance point using direct displacement-based design method was developed to enhance the applicability of the method. Parametric study has been performed for the natural period of the structure, yield strength, and the stiffness after the first yield. The proposed method was also applied to a 10-story steel frame. To verify the accuracy of the result, the results from capacity spectrum analysis and time history analysis were compared. The results of the proposed method turned out to match well with the results of capacity spectrum method and the time history analysis.

  • PDF

LRB 교좌장치를 사용한 교량의 장대레일 축력안정성 평가 (Stability evaluation of CWR on the bridge with lead Rubber Bearing(LRB))

  • 양신추;윤철균;이진우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.787-792
    • /
    • 2004
  • LRB(Lead rubber bearing) has small resistance force against slowly acting loadings such as temporal and creep loadings vice versa large resistance force against rapid loadings such as earthquake and braking loadings. By those mechanical characteristics, it has the advantage to reduce longitudinal load acting on abutments and piers, and moreover to in1prove the running stability of train by restricting the behavior of bridge under the required level. In this study, a stability evaluation method of CWR on the bridge with LRB is presented. Several parametric studies are carried to investigate how LRB contributes to the improvement of CWR stability.

  • PDF

배전계통 보호시스템의 보호능력의 평가방법 (A Protective Effectiveness Measure for Distribution Systems)

  • 현승호;이승재;임성일;최인선;신재항;최면송
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권5호
    • /
    • pp.249-256
    • /
    • 2004
  • This paper suggests a novel evaluation scheme of protective effectiveness in distribution systems. The adequacy of every parameter in a protective device is evaluated for the setting or correction rules. Then, the protective effectiveness of a device, device-wise effectiveness, is obtained by the combination of the parametric evaluation results. The coordination-wise effectiveness between devices can be calculated by evaluating the parameters which contribute the performance of coordination. The protective effectiveness of the whole system can be obtained by combining the device-wise and coordination-wise effectiveness values. The rules, in this paper, are categorized into three groups; rules for single parameter, rules for coordination between parameters, and rules for coordination between protective devices to form a hierarchical calculation model. The proposed method is applied to a typical distribution network to show its effectiveness.