Analysis of Harmonic Effects on Substation Power System and its Countermeasure (지하철 전력계통의 고조파 영향 분석 및 그 대책에 관한 연구)

  • Song, Jin-Ho;Hwang, Yu-Mo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.4
    • /
    • pp.210-220
    • /
    • 2002
  • We analysised the effect of harmonics on electric machines of substation power system barred on quantitatively measured harmonics and proposed the methods for prevention of harmonics through checking on transformer, rectifier and cable's capacities against harmonics with reference to KEPCO's electricity service standard. In order to analysis harmoninics of silicon rectifier that is power source in DC substation, computer simulations for a substation with TR of high voltage distribution switchboard are performed. Simulation results show that the total harmonic distortion factor becomes smaller for TR primary and receiving points in order rather than silicon rectifier which is harmonic generation source so that the harmonics generated frets each rectifier are outflowed to power supply and high voltage distribution switchboard The result of higher distortion factors of voltage and current for rectifier with 100% load than those with 50 % and 30% indicates that the waveform of voltage and current for the real substation power system at the office-going and the closing hours with heavy loads might be more distorted. As proposed methods for harmonic reduction, the conventional 6 pulse-type for substation is required to be replaced by 12 pulse-type for reduction of 5th and 7th harmonics. The active filter rather than the passive filter is more effective due to severe variance of rectifier loads, but the high cost is price to be paid. In view of installation area and costs, the use of 12 pulse-type transformer is desirable and then the parallel transformer and the rectifier within the substation must be replaced at the same time. Other substations with parallel feeder can use 6 pulse-type transformer.

Leaky Wave Radiation and Surface Wave Launching Problem in a Dielectrically Covered Periodically Slitted Parallel-Plate Waveguide (주기적인 슬릿을 갖고 유전체층으로 덮힌 평행평판 도파관에서의 누설파 복사 및 표면파 launching)

  • 이종익;이철훈;조영기
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.4
    • /
    • pp.25-33
    • /
    • 1999
  • Leaky wave radiation and surface wave launching problems in a dielectrically covered and periodically slitted parallel-plate waveguide(PPW) are considered for the TEM wave incidence case. Both the infinite and finite periodic geometries are analyzed by use of the method of moments. Some numerical results for the reflected and transmitted powers in the PPW, radiation efficiency into the free space, surface wave launching efficiency into the slab, antenna gain, and radiation patterns against dielectric thickness are presented to show the effect of the dielectric cover on the performances of the slitted leaky wave antenna. In addition, the method for improving surface wave launching efficiency using the proposed periodic geometry is described and maximum launching efficiency of 97.5% is obtained theoretically. So this structure is thought to be promising as an efficient feeder of dielectric grating antenna as well as image guide.

  • PDF

A Study on the Voltage Drop and Earth Leakage Current according to Interval of AT in the AT Feeding Method (AT급전방식에서 AT간격에 따른 전압강하 및 대지누설전류에 대한 연구)

  • Kim, Min-Seok;Choe, Seung-Hyuk;Lee, Jong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1708-1714
    • /
    • 2011
  • AT feeding system of the electric railway system is installed every about 10km at between the feeder and catenary in parallel and the mid-point of the transformer is connected to the rail The supply voltage of this system is doubled than rolling stock voltage. So the voltage drop is smaller than usual. And the other merit of this system is the decreasing inductive disturbance to the communication line because of the reduced current in rail which runs reversed in a point of view of rolling stock. Also, ATP(Auto Transformer Post) is installed to reduce the voltage drop and to mitigate the inductive disturbance, but still now the proper distance between the ATP and AT feeding system is not established which ranges from 2 to 10[km]. The stable result of simulation(which is set that the end of the line AT is installed) to the voltage drop and inductive disturbance can not analyzes the effect to the supply system due to the ATP. This paper analyzes the effect to the system depending on the location of ATP by forecasting the voltage drop and inductive disturbance.

Thirteen-Week Repeated Oral Toxicity Study of Paecilomyces sinclairii in Sprague-Dawely Rats (랫드에서 매미눈꽃동충하초, Paecilomyces sinclairii의 13주 반복투여 독성에 관한 연구)

  • Ahn Mi Young;Jee Sang Duk;Kim Ji Young;Han Jea Woong;Lee Yang Ki;Lee Yang Woo;Ryu Kang Sun;Lee Byung Mu;Jung Na Jin;Kim Sung Nam
    • Toxicological Research
    • /
    • v.20 no.4
    • /
    • pp.339-348
    • /
    • 2004
  • Paecilomyces sinclairii was administered ad libitum feeding at percentage levels of 0, 1.25, 2.5, 5 and 10 percentage (calculated about 8 g/kg)/feeder for a period of 3 months. There was no observed clinical signs or deaths related to treatment in all groups tested. Therefore, the approximate lethal dose of P. sinclairii was considered to be higher than 8 g/kg in rats. Mild decreases in body weight gain were observed dose-dependently in P. sinclairii treated groups in dose response manner after 2 weeks. Interestingly, the weight of abdominal adipose tissues surrounding epididymides were greatly reduced by this Dongchunghacho, in parallel with the mild increase in body weight gain. However, the absolute weight change of other organs was not observed. There were not significantly different from the control group in urinalysis, ocular examination, hematological, serum biochemical value and histopathological examination. From these results, it is concluded that the no-observed-adverse-effect level (NOAEL) of P. sinclairii is less than 1.25% (1 g/kg) in rats in the present study.

Optimal Operation Method and Capacity of Energy Storage System(ESS) in Primary Feeders with Step Voltage Regulator(SVR) (선로전압조정장치(SVR)가 설치된 고압배전선로에서 전기저장장치(ESS)의 최적운용 및 적정용량 산정방안)

  • Kim, Byungki;Ryu, Kyung-Sang;Kim, Dae-Jin;Jang, Moon-seok;Ko, Hee-sang;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.9-20
    • /
    • 2018
  • When a large-scale photovoltaic (PV) system is introduced into a distribution system, the customer's voltage may exceed the allowable limit ($220V{\pm}6%$) due to voltage variations and reverse power flow in the PV system. In order to solve this problem, we propose a method for adjusting the customer voltage using the existing step voltage regulator (SVR) installed in the primary feeder. However, due to the characteristics of a mechanically operating SVR, the customer voltage during the tap changing time of the SVR is likely to deviate from the allowable limit. In this paper, an energy storage system (ESS) with optimal operation strategies, and an appropriate capacity calculation algorithm are proposed, and the parallel driving scheme between the SVR and the ESS is also proposed to solve the customer voltage problem that may occur during the tap changing time of the SVR. The simulation results show that the allowable limit of the customer voltage is verified by the proposed methods during the tap changing time of the SVR when the large-scale PV system is connected to the distribution system.