• Title/Summary/Keyword: Parallel-circuit line

Search Result 125, Processing Time 0.023 seconds

Current Limiting Characteristics of a Flux-Lock Type SFCL for a Single-Line-to-Ground Fault

  • Oh, Geum-Kon;Jun, Hyung-Seok;Lee, Na-Young;Choi, Hyo-Sang;Nam, Gueng-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.9
    • /
    • pp.70-77
    • /
    • 2006
  • We have fabricated an integrated three-phase flux-lock type SFCL, which consists of an YBCO($YB_a2Cu_3O_7$) thin film and a flux-lock reactor wound around an iron core of each phase. In order to apply the SFCL in a real power system, fault analyses for the three-phase system are essential. The short-circuit currents were effectively limited by adjusting the numbers of winding of each secondary coil and their winding directions. The flux flow generated in the iron core cancelled out under the normal operation due to the parallel connection between primary and secondary windings. However, the flux-lock type SFCL with same iron core was operated just after the fault due to the flux generating in the iron core. To analyze the current limiting characteristics, the additive polarity winding was compared with the subtractive one in the flux lock reactor. Whenever a single line-to-ground fault occurred in any phase, the peak value of the line current of the fault phase in the additive polarity winding increased up to about 12.87 times during the first-half cycle. On the other hand, the peak value in the subtractive polarity winding increased up to about 34.07 times under the same conditions. This is because the current flow between the primary and the secondary windings changed to additive or subtractive status according to the winding direction. We confirmed that the current limiting behavior in the additive polarity winding was more effective for a single-line-to-ground fault

Microwave Group Delay Time Adjuster Using Resonance Circuit (공진 회로를 이용한 마이크로파 군지연 시간 조정기)

  • Seo Su-Jin;Park Sang-Keun;Choi Heung-Jae;Jeong Yong-Chae;Yun Jae-Hun;Kim Chul-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.8 s.111
    • /
    • pp.739-745
    • /
    • 2006
  • This paper presents a method to control group delay tine using a resonance circuit. The group delay time adjuster(GDTA) that can control signal group delay time comprises a variable capacitance and a variable equivalent inductor. These are coupled in parallel at a node and also controlled by two bias voltages separately, A variable equivalent inductor is realized a transmission line terminated a variable capacitor. Group delay time can be controlled by change of capacitance and inductance, but the resonating frequency is fixed. When the proposed GDTA is fabricated on RFID Korean frequency band$(908.5{\sim}914 MHz)$, a group delay variation is obtained about 3 ns.

The analysis of the operating characteristic for the wideband coaxial line impedance transformer (광대역 동축선로 임피던스 변환회로의 동작 특성 분석)

  • Park, Ung-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.2
    • /
    • pp.165-172
    • /
    • 2019
  • Using two or more coaxial lines, if one port is connected in series and the other port is connected in parallel, it can be implemented the wideband transmission line transformer(TLT). Because the wideband TLT utilizes the outer conductor of the coaxial line, it is difficult to predict the characteristics. In this paper, based on the analysis for the transfer characteristic(S21) according to the loss of the each line in ${\lambda}/4$-microstrip line TLT, the operating characteristic of the fabricated wideband 4:1 TLT using two $25{\Omega}$-coaxial lines is investigated. The fabricated wideband TLT shows the notch characteristic in which the transfer signal sharply decreases at ${\lambda}/4$ frequency of the coaxial line and has a value within -0.2dB of the transfer characteristic(S21) in $0.06{\sim}0.2{\lambda}$ frequency range of the coaxial line. This transfer characteristics(S21) can change the operating frequency range slightly and set the optimum transfer characteristic(S21) at the desired frequency by changing the length of the microstrip line.

Triplexer based on Filter Characteristics of CRLH Transmission Line and Triple-Band Amplifier Applications (CRLH 전송선로의 필터 특성을 이용한 트리플렉서와 삼중대역 증폭기에의 응용)

  • Yun, Jeong-Ho;Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.3
    • /
    • pp.433-439
    • /
    • 2012
  • In this paper, we proposed the triplexer using unit-cell of CRLH transmission line which has a bandpass characteristic to reduce adjacent channel interference. The input impedance of triplexer with each channel filter is operated open-circuit at the resonance frequencies of other channels. Such property is due to the combination a series and parallel resonance circuits of CRLH-TL unit-cell. The measured triplexer results are showed a measured insertion loss of each channel, less than 1.5 dB, matching at each port, less than 15dB and isolation between channel, better than 25 dB. Also, to validate the triplexer, a small signal amplifier with triple-band is designed and tested. the measured amplifier results show good agreements with prediction.

A Study on Slot Coupled Capacitor Resonator for Non-Invasive Glucose Monitoring in Earlobe (귓불에서 비침습 혈당관찰을 위한 슬롯결합 커패시터 공진기 연구)

  • Yun, Gi-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.4
    • /
    • pp.279-285
    • /
    • 2017
  • In this paper, the resonator with a parallel plate capacitor is newly proposed around sub-microwave frequency band and applied to earlobe for non-invasive glucose monitoring the human biological tissue. The capacitor including the earlobe as dielectric material is connected to inductive slot in the ground plane of the microstrip line. Based on the simulation, one port resonator circuit is designed and fabricated as a prototype. Three step glucose concentration levels(0, 250, 500 mg/dL) was tested, and its reflection coefficients($S_{11}$) were measured. Owing to high Q resonator more than 100, resonant frequency shift of about 9 MHz per glucose level of 250 mg/dL has been successfully measured. This proves that the proposed sensor is applicable to a blood glucose sensor.

Dual Utility AC Line Voltage Operated Voltage Source and Soft Switching PWM DC-DC Converter with High Frequency Transformer Link for Arc Welding Equipment

  • Morimoto Keiki;Ahmed NabilA.;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.366-373
    • /
    • 2005
  • This paper presents two new circuit topologies of the dc busline side active resonant snubber assisted voltage source high frequency link soft switching PWM full-bridge dc-dc power converters acceptable for either utility ac 200V-rms or ac 400V-rms input grid. These high frequency switching dc-dc converters proposed in this paper are composed of a typical voltage source-fed full-bridge PWM inverter, high frequency transformer with center tap, high frequency diode rectifier with inductor input filter and dc busline side series switches with the aid of a dc busline parallel capacitive lossless snubber. All the active switches in the full-bridge arms as well as dc busline snubber can achieve ZCS turn-on and ZVS turn-off transition commutation with the aid of a transformer leakage inductive component and consequently the total switching power losses can be effectively reduced. So that, a high switching frequency operation of IGBTs in the voltage source full bridge inverter can be actually designed more than about 20 kHz. It is confirmed that the more the switching frequency of full-bridge soft switching inverter increases, the more soft switching PWM dc-dc converter with a high frequency transformer link has remarkable advantages for its power conversion efficiency and power density implementations as compared with the conventional hard switching PWM inverter type dc-dc power converter. The effectiveness of these new dc-dc power converter topologies can be proved to be more suitable for low voltage and large current dc-dc power supply as arc welding equipment from a practical point of view.

Design and Fabrication of a Minimum Insertion Loss Parallel-Coupled-Line-Filter for the Suppression of LO Harmonics (최소 삽입 손실을 갖는 국부 발진기 고조파 제거를 위한 병렬 결합 전송 선로 대역 여파기의 설계 및 제작)

  • Kim, Hyun-Mi;Yang, Seong-Sik;Oh, Hyun-Seok;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.5 s.120
    • /
    • pp.486-495
    • /
    • 2007
  • In this paper, we present the design procedure of BPF(Band Pass Filter) for the suppression of LO(Local Oscillator) harmonics. The required suppression at given harmonics is the key issues in such a filter design, while the bandwidth and the suppression of the unwanted signals are more important in the conventional RF filter design. In LO filter design the bandwidth is used for the minimization of the insertion loss for the desired signal. In addition, we propose the novel tuning procedure based on Momentum to consider the unknown parasitic effects, which usually are not included in the circuit design step and results in undesirable and frustrating tuning after fabrication.

A Study on the Serial-Parallel Resonant DC/DC Converter for Contactless Power Supply System (비접촉 전원장치에 적용한 직.병렬 공진 DC/DC 컨버터에 관한 연구)

  • Hwang, Gye-Ho;Lee, Bong-Sub;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.31-40
    • /
    • 2008
  • Recently, Contactless Power Supply(CPS) system has been broadly studied as a power supply system for Flat Panel Display(FPD) material transfer equipments. In mass production line, CPS systems on material transfer equipment are applied only in the straight sections with single operating vehicle. The formal CPS system was not adequate for curved section nor multiple operating vehicles. Therefore, this paper presents CPS system that consists of straight and curved section with multiple operation vehicles. The circuit topology of CPS system consists of full bridge configured serial-parallel resonant DC/DC converter. The control method for CPS system consists of duty control method on the primary power supply system to maintain constant resonant current. And the secondary power supply systems of multiple vehicles are self controled to maintain constant output voltage. Practically, the test result of dual vehicles on straight and curved section of material transfer equipments were satisfactory, and proved it's applicability on commercial use.

Fabrication and Test of the Three-Phase 6.6 kV Resistive Superconducting Fault Current Limiter Using YBCO Thin Films (YBCO 박막을 이용한 3상 6.6kV 저항형 초전도 한류기 제작 및 시험)

  • Sim J.;Kim H. R.;Park K. B.;Kang J. S.;Lee B. W.;Oh I. S.;Hyun O. B.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.3
    • /
    • pp.50-55
    • /
    • 2004
  • We fabricated and tested a resistive type superconducting fault current limiter (SFCL) of three-phase 6.6 $kV_{rms}/200 A_{rms}$ rating based on YBCO thin films grown on sapphire substrates with a diameter of 4 inches, Short circuit tests were carried out at a accredited test facility for single line-to- ground faults, phase-to-phase faults and three-phase faults, Each phase of the SFCL was composed of 8${\times}$6 elements connected in series and parallel respectively. Each element was designed to have the rated voltage of 600 $V_{rms}$. A NiCr shunt resistor of 23 Ω was connected to each element for simultaneous quenches. Firstly, single phase-to-ground fault tests were carried out. The SFCL successfully developed the impedance in the circuit within 0.12 msec after fault and controlled the fault current of 10 $kA_{rms} below 816 A_{peak}$ at the first half cycle. In addition, in case of phase-to-phase fault and three- phase fault test. simultaneous quenches among the SFCLs of the phases successfully accomplished. In conclusion. the SFCL showed excellent performance of current limitation upon fault and stable operation regardless of the amplitude of fault currents.

A Study on Control and Compensating Characteristics of Active Series Voltage Compensator with Harmonic Current Compensating Capability (고조파전류 보상 기능을 갖는 능동 직렬 전압보상기의 제어 및 보상특성에 관한 연구)

  • 이승요;김홍성;최규하;신우석;김홍근
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.5
    • /
    • pp.484-492
    • /
    • 2000
  • In this paper, a voltage compensator with harmonic current compensating capability is studied and its compensating characteristics are analyzed. Like the hybrid active power filter, the proposed system is composed of parallel LC passive filter and series PWM converter connected to power line through series transformer. It is shown that the compensation of harmonic current generated due to nonlinear loads such as diode rectifier and instantaneous voltage compensation of the source are performed through the proposed compensating system. The operating principle of the proposed system is described through a single-phase equivalent circuit and the control strategy is suggested on the d-q rotating reference frame of the 3-phase system. Also, experiment is carried out to verify compensating characteristics of the proposed system.

  • PDF