• 제목/요약/키워드: Parallel impedance

검색결과 293건 처리시간 0.027초

$RuO_2$계 후막저항체의 교류 임피던스특성 (A.C. Impedance Properties on $RuO_2$-Based Thick Film Resistors.)

  • 구본급;김호기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.215-220
    • /
    • 1990
  • A.C. impedance properties of $RuO_2$ based thick film resistors which having different resistivity value (DuPont 1721 : $100{\Omega}$/ sq., 1741 : $10K{\Omega}$/sq.) were investigated using by impedance analyzer. In case of lower resistivity 1721 system, the complex impedance was composed nearly R component for all speciman sintered at above $600^{\circ}C$, and the frequency dependancy on impedance was not affected very much up to 5MHz and again gradually increase with increasing the frequency. In case of higher resistivity 1741 resistor system, impedance properties were very depandant on sintering temperature. When sintering temperature was $600^{\circ}C$, the complex impedance plot shows a vertical line, which correspond to lone capacitance equivalant circuit, and the impedance linearly decreased with increasing frequency. In case of speciman sintered at $700-900^{\circ}C$, the complex impedance plot shows semi-circular are correspond to a lumped RC combination, and the impedance shows constant value to 5MHz, again decreased with increasing frequency. But the complex impedance behavior of speciman sintered at $1000^{\circ}C$ was shows the equivalent circuit correspont to parallel combined LCR component, and the impedance was not varied with frequency.

  • PDF

A Virtual RLC Active Damping Method for LCL-Type Grid-Connected Inverters

  • Geng, Yiwen;Qi, Yawen;Zheng, Pengfei;Guo, Fei;Gao, Xiang
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1555-1566
    • /
    • 2018
  • Proportional capacitor-current-feedback active damping (AD) is a common damping method for the resonance of LCL-type grid-connected inverters. Proportional capacitor-current-feedback AD behaves as a virtual resistor in parallel with the capacitor. However, the existence of delay in the actual control system causes impedance in the virtual resistor. Impedance is manifested as negative resistance when the resonance frequency exceeds one-sixth of the sampling frequency ($f_s/6$). As a result, the damping effect disappears. To extend the system damping region, this study proposes a virtual resistor-inductor-capacitor (RLC) AD method. The method is implemented by feeding the filter capacitor current passing through a band-pass filter, which functions as a virtual RLC in parallel with the filter capacitor to achieve positive resistance in a wide resonance frequency range. A combination of Nyquist theory and system close-loop pole-zero diagrams is used for damping parameter design to obtain optimal damping parameters. An experiment is performed with a 10 kW grid-connected inverter. The effectiveness of the proposed AD method and the system's robustness against grid impedance variation are demonstrated.

$CF_4$ 플라즈마 처리된 ITO박막을 이용한 유기 EL 소자의 성능향상에 관한 임피던스 분석 (Impedance spectroscopy analysis of organic light emitting diodes with the $CF_4$ anode plasma treatment)

  • 박형준;김현민;이준신;손선영;정동근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.320-321
    • /
    • 2006
  • In this work, impedance Spectroscopic analysis was applied to study the effect of plasma treatment on the surface of indium-tin oxide (ITO) anodes using $CF_4g$ as and to model the equivalent circuit for organic light emitting diodes (OLEDs) with the $CF_4$ plasma treatment of ITO surface at the anodes. This device with ITO/TPD/$Alq_3$/LiF/Al structure can be modeled as a simple combination of a resistor and a capacitor. The $CF_4$ plasma treatment on the surface of ITO shifts the vacuum level of the ITO as a result of which the barrier height for hole injection at the ITO/organic interface is reduced. The Impedance spectroscopy measurement of the devices with the $CF_4$ plasma treatment on the surface of ITO anodes shows change of values in parallel resistance ($R_p$) and parallel capacitance ($C_p$).

  • PDF

저압 산소 플라즈마 처리된 ITO박막을 이용한 유기 EL 소자의 성능 향상에 관한 임피던스 분석 (Impedance spectroscopy analysis of organic light emitting diodes with the $O_2$ anode plasma treatment)

  • 김현민;박형준;이준신;오세명;정동근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.436-437
    • /
    • 2006
  • In this work, impedance Spectroscopic analysis was applied to study the effect of plasma treatment on the surface of indum-tin oxide (ITO) anodes using $O_2$ gas and to model the equivalent circuit for organic light emitting diodes (OLEDs) with the $O_2$ plasma treatment of ITO surface at the anodes. This device with ITO/TPD/Alq3/LiF/Al structure can be modeled as a simple combination of a resistor and a capacitor. The $O_2$ plasma treatment on the surface of ITO shifts the vacuum level of the ITO as a result of which the barrier height for hole injection at the ITO/organic interface is reduced. The impedance spectroscopy measurement of the devices with the $O_2$ plasma treatment on the surface of ITO anodes shows change of values in parallel resistance ($R_p$) and parallel capacitance ($C_p$).

  • PDF

345[kV] 전력용 변압기 %임피던스 변화에 따른 계통영향 분석 (A Study on the Impact of the Impedance Change of 345[kV] Power Transformers on Overall System Performance)

  • 신정훈;남수철;이재걸;백승묵;송지영;김태균
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.140-149
    • /
    • 2011
  • This paper deals with the impact analysis of the impedance change of 345/154[kV] power transformers on the KEPCO system's overall performance. Through the steady-state and dynamic analysis of power system, the maximum available impedance of power transformers were determined. Checking violation of short-circuit current ratings and transformer overload, parallel operation of power transformers, calculation of voltage variation ratio according to the impedance changes of power transformers are included in the steady-state analysis. In addition, transient and voltage stability analysis are also performed in the study. Available magnitudes to be able to change the impedance of the transformers in KEPCO system are finally determined in the paper.

Hybrid acceleration-impedance sensor nodes on Imote2-platform for damage monitoring in steel girder connections

  • Kim, Jeong-Tae;Park, Jae-Hyung;Hong, Dong-Soo;Ho, Duc-Duy
    • Smart Structures and Systems
    • /
    • 제7권5호
    • /
    • pp.393-416
    • /
    • 2011
  • Hybrid acceleration-impedance sensor nodes on Imote2-platform are designed for damage monitoring in steel girder connections. Thus, the feasibility of the sensor nodes is examined about its performance for vibration-based global monitoring and impedance-based local monitoring in the structural systems. To achieve the objective, the following approaches are implemented. First, a damage monitoring scheme is described in parallel with global vibration-based methods and local impedance-based methods. Second, multi-scale sensor nodes that enable combined acceleration-impedance monitoring are described on the design of hardware components and embedded software to operate. Third, the performances of the multi-scale sensor nodes are experimentally evaluated from damage monitoring in a lab-scaled steel girder with bolted connection joints.

자기단 전원 임피던스 추정 기법을 사용한 병행 2회선 송전선로 고장점 표정 알고리즘 (A Fault Location Algorithm Using Adaptively Estimated Local Source Impedance for a Double-Circuit Transmission Line System)

  • 박건호;강상희;김석일;신종한
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.373-379
    • /
    • 2012
  • This paper presents a fault location algorithm based on the adaptively estimated value of the local sequence source impedance for faults on a parallel transmission line. This algorithm uses only the local voltage and current signals of a faulted circuit. The remote current signals and the zero-sequence current of the healthy adjacent circuit are calculated by using the current distribution factors together with the local terminal currents of the faulted circuit. The current distribution factors consist of local equivalent source impedance and the others such as fault distance, line impedance and remote equivalent source impedance. It means that the values of the current distribution factors can change according to the operation condition of a power system. Consequently, the accuracy of the fault location algorithm is affected by the two values of equivalent source impedances, one is local source impedance and the other is remote source impedance. Nevertheless, only the local equivalent impedance can be estimated in this paper. A series of test results using EMTP simulation data show the effectiveness of the proposed algorithm. The proposed algorithm is valid for a double-circuit transmission line system where the equivalent source impedance changes continuously.

평행 결합 선로를 이용한 복합 광대역 기법 적용 마이크로스트립 안테나에 관한 연구 (A Study on Compound Technique for Increasing the Bandwidth of Microstrip Antennas using the Paralle Coupled Lines)

  • 김정일;한만군;윤영중
    • 한국전자파학회논문지
    • /
    • 제12권5호
    • /
    • pp.713-721
    • /
    • 2001
  • 본 논문에서는 이미 설계된 기생 패치 구조와 적층 구조 광대역 마이크로스트립 안테나에 평행 결합 선로 형태의 광대역 임피던스 정합 회로를 결합하여 쉽게 추가적인 대역폭 증가를 이룰 수 있음을 제안하였다. 평행결합 선로 형태의 광대역 임피던스 정합 회로 설계를 위하여 분포 회로 방식의 반복적인 방법을 제시하였고, 설계.제작한 안테나의 측정 결과 기생 패치 구조와 적층 구조에서 각각 약 1.6배 1.5배의 추가적인 임피던스 대역폭 증가를 이룰 수 있었다. 그리고 방사 패턴과 측정된 이득을 보면 평행 결합 선로의 결합으로 인한 방산 패턴에서의 큰 변화는 보이지 않았지만, 이득에서는 평행 결합 선로 부분의 커플링 손실로 인해 최대 이득이 약 1 dB와 0.5 dB 정도 감소하는 것을 확인할 수 있었다.

  • PDF

도전성지주에 평행한 포울디드.다이폴안테나에 관하여 (Study on a Folded Diple Antenna parallel to Conductive Pole)

  • 박정기
    • 대한전자공학회논문지
    • /
    • 제5권4호
    • /
    • pp.9-19
    • /
    • 1968
  • 길이 3/2λ의 도전성지주에 좁은 간격으로 반파장 다이폴 안테나를 평행하게 놓았을때(앞으로 이와같은 경우를 평행 2선식 안테나계라 함)의 급전임피이던스와, 같은 지주에 역시 좁은 간격으로 포울디드 다이폴 안테나를 평행하게 놓고 포울디드 다이폴 안테나의 급전단이 아닌쪽의 중점과 도전성지주의 중점 사이를 지주에 수직한 도체로 연결한 경우(앞으로 이와같은 경우를 평행 3선식 안테나계라 부름)의 급전임피이던스의 이론식을 각각 구하였다. 위의 두 식의 비교에서 급전임피이던스의 값이 평행 2선식 안테나계의 4배가 되기는 하지만 똑같은 꼴의 급전임피이던스를 갖는, 즉, 평행 2선식 안테나계와 똑같은 모양의 방사를 하는 평행 3선식 안테나계를 얻는데 필요한 조건을 유도했다. 위의 평행 2선식에 등가한 평행 3선식 안테나계로 수직편파전방향성 안테나계를 실현할 수 있다는 것에 착목하여 도체주에 포울디드 다이폴 안테나 1단을 취부하였을 때의 급전임피이던스를 측정고찰하였다.

  • PDF

바이오센서를 위한 PC 기반의 휴대용 고속 임피던스 분석기 개발 (Development of PC-based and portable high speed impedance analyzer for biosensor)

  • 김기련;김광년;허승덕;이승훈;최병철;김철한;전계록;정동근
    • 센서학회지
    • /
    • 제14권1호
    • /
    • pp.33-41
    • /
    • 2005
  • For more convenient electrode-electrolyte interface impedance analysis in biosensor, a stand-alone impedance measurement system is required. In our study, we developed a PC-based portable system to analyze impedance of the electrochemical cell using microprocessor. The devised system consists of signal generator, programmable amplifiers, A/D converter, low pass filter, potentiostat, I/V converter, microprocessor, and PC interface. As a microprocessor, PIC16F877 which has the processing speed of 5 MIPS was used. For data acquisition, the sampling rate at 40 k samples/sec, resolution of 12 bit is used. RS-232 with 115.2 kbps speed is used for the PC communication. The square wave was used as stimuli signal for impedance analysis and voltage-controlled current measurement method of three-electrode-method were adopted. Acquired voltage and current data are calculated to multifrequency impedance signal after Fourier transform. To evaluate the implemented system, we set up the dummy cell as equivalent circuit of which was composed of resistor, parallel circuit of capacitor and resistor connected in parallel and measured the impedance of the dummy cell; the result showed that there exist accuracy within 5 % errors and reproduction within 1 % errors compared to output of Hioki LCR tester and HP impedance analyzer as a standard product. These results imply that it is possible to analyze electrode-electrolyte interface impedance quantitatively in biosensor and to implement the more portable high speed impedance analysis system compared to existing systems.