• 제목/요약/키워드: Parallel connecting

검색결과 154건 처리시간 0.027초

The Dual Design of Fuel Cell Hybrid Power System using Dual Converter PCS (1.5kW 연료전지 복합발전 시스템의 듀얼 컨버터 설계)

  • Shin, Soo-Cheol;Lee, Hee-Jun;Hong, Suk-Jin;Kim, Hak-Sung;Won, Chung-Yuen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제27권7호
    • /
    • pp.67-75
    • /
    • 2013
  • In this paper, parallel input/serial output dual converter is designed appropriately for fuel cell hybrid power system. In case of proposed converter, zero voltage switching condition is designed without additional resonance device using leakage inductance of transformer and output capacitance of switch, and zero voltage switching method is used. Also, the system method is for increasing power by connecting half-bridge in parallel and increasing output voltage by connecting secondary output of transformer in serial. Through this method we can increase power and decrease volume of system. So in this paper, dual converter is designed. 1.5kW fuel cell hybrid power system was implemented, and system operation and stability was verified through experiment.

A Study on the Correlationship between Spatial Structure and Shop Composition in Mixed-Use Facilities - Focused on the Typological Analysis about Lower Part of the Facilities Built After the Year 2000 - (복합상업시설 실내 공간구조와 매장구성 성향간 상관성 분석 - 2000년대 건립사례 저층부의 유형학적 분석을 중심으로 -)

  • Hyun, Chang-Yong
    • Korean Institute of Interior Design Journal
    • /
    • 제26권6호
    • /
    • pp.62-70
    • /
    • 2017
  • This study has a purpose that definitize correlationship of spatial structure and sales strategies in mixed-use complexes which established in Korea since year 2000. For this purpose, this study tries to analysis spatial structure of mixed-use facilities through space syntax theory and makes an typological categorization based on their space composition. As a result of categorization, Korean mixed-use facilities can be classed as three types. First type is integrated stacking type. Second one is parallel connecting type. Third type is room to room type. According to differences between categories, their spatial structures show different meaning with different sales strategies. Integrated stacking type sales luxury brands and expensive stuffs and it also has deep and complicated structure. That means theses spaces usually make a strategy of exclusion. Parallel connecting type sales special categories and it also has shallow and easy spatial structure. That means these facilities want to make a smooth connection between apposed volumes. Room to room type sales cheap and fancy objects and it also has simple and shallow structure. That means simple spatial structure can be lead contact customer to stuffs. These results mean spatial structure have a effect on design of sales space.

Real time simulation using multiple DSPs for fossil power plants (병렬처리를 이용한 화력발전소의 실시간 시뮬레이션)

  • 박희준;김병국
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.480-483
    • /
    • 1997
  • A fossil power plant can be modeled by a lot of algebraic equations and differential equations. When we simulate a large, complicated fossil power plant by a computer such as workstation or PC, it takes much time until overall equations are completely calculated. Therefore, new processing systems which have high computing speed is ultimately needed to develope real-time simulators. Vital points of real-time simulators are accuracy, computing speed, and deadline observing. In this paper, we present a enhanced strategy in which we can provide powerful computing power by parallel processing of DSP processors with communication links. We designed general purpose DSP modules, and a VME interface module. Because the DSP module is designed for general purpose, we can easily expand the parallel system by just connecting new DSP modules to the system. Additionally we propose methods about downloading programs, initial data to each DSP module via VME bus, DPRAM and processing sequences about computing and updating values between DSP modules and CPU30 board when the simulator is working.

  • PDF

Imperfections in $LiTaO_3$ Crystal ($LiTaO_3$ 단결정의 결함)

  • 김한균;박승익;박현민;정수진
    • Journal of the Korean Ceramic Society
    • /
    • 제31권2호
    • /
    • pp.147-154
    • /
    • 1994
  • The imperfections of LiTaO3 crystals grown from the Pt-Rh and the Ir crucible were investigated with X-ray diffraction, optical and electron microscope. The growth direction was <100>h and the plane parallel to the plane connecting two main growth ridges was (012)h which would be the main cleavage plane. The dislocation density in the specimen cut parallel to (012)h plane increased with polishing time and the inverted ferroelectric microdomains were induced based on this dislocations. Such imperfections as 180$^{\circ}$ domains, microcracks, dislocations and stacking faults. could be found in the LiTaO3 crytals. The crystal contaminated with lots of Rh form Pt-Rh crucible during the crystal growing under air atmosphere contained more imperfections. The main cleavage plane and subgrain boundary parallel to its growing axis might be the main source of reducing the mechnical strength during the wafering process.

  • PDF

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Choi Y.K.;Ko T.G.
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.987-993
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Furthermore, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristic.

  • PDF

Numerical Investigation on Turbulent Flow Characteristics in the Gap connecting with Two parallel Channels using Large Eddy Simulation (평행한 두 사각유로를 연결하는 협소유로내의 난류유동 특성에 관한 대형 와 수치 모사)

  • Hong, Seong-Ho;Seo, Jeong-Sik;Shin, Jong-Keun;Choi, Young-Don
    • Proceedings of the SAREK Conference
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.55-60
    • /
    • 2008
  • Turbulent flow characteristics on the gap of two parallel channels are investigated using LES(large eddy simulation) approach. Two parallel channels have the same cross-section area and are connected by the narrow channel named the gap. Turbulent flow near the gap makes the flow pulsation along the streamwise direction of two channels. The flow condition is the Reynolds number of $2.5{\times}10^{-5}$. We compared the predicted results with the previous experimental results and presented the axial mean velocity, turbulent intensities, Reynolds shear stresses and turbulent kinetic energy.

  • PDF

Module UPS of multi-parallel operation for use in information & telecommunication systems (정보통신용 다병렬 운전의 모듈식 무정전전원장치)

  • Koo, Tae-Geun;Ryu, Ji-Su;Bae, Sang-Gyu;Park, Keun-Kap
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2007년도 학술대회
    • /
    • pp.390-393
    • /
    • 2007
  • The reliability as well as the power capability of the UPS system can be increased by replacing a single UPS unit with multiple small UPS units in parallel, resulting in a so-called module UPS. This module UPS system allows that a new module can be added or replaced while maintaining power to loads, which is a hot-swappable operation. In addition, it has desirable features such as ease of output power expandability, convenience of maintenance and repair, and high reliability. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. 5kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the module UPS system has a high power factor, a low distortion of output voltage and input current, hot-swappable operations and good load sharing characteristics.

  • PDF

A Study on Improvement of Powerfactor and Source Waveform Converter System of Power Supply for HVDC Transmission (HVDC 송전을 위한 전원용 컨버터 시스템의 역률 및 파형개선에 관한 연구)

  • Hwang, Lak-Hoon;Lee, Chun-Sang;Lee, Sang-Yong;Na, Seng-Kwon;Cho, Moon-Taek
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.395-397
    • /
    • 1999
  • This paper presents a method of improving the power factor and the waveform of A.C line currents and the out waveforms of AC to DC fully bridge converter systems which is achieved by connecting converters in series and parallel. The results of simulation show that the power factor and the source voltage and current waveforms are improved by the method of connecting converter in series, and the controlled input voltage and current waveform using a current limit controller.

  • PDF

Design of a High Stiffness Machining Robot Arm with Double Parallel Mechanism (기계가공작업을 위한 강성이 큰 2단 평행구조 로보트 암 설계)

  • 이민기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제19권1호
    • /
    • pp.22-37
    • /
    • 1995
  • Industrial robot has played a central role in the production automation such as welding, assembling, and painting. There has been, however, little effort to the application of robots in machining work(grinding, cutting, milling, etc.) which is typical 3D work. The machining automation requires a high stiffness robot arm to reduce deformation and vibration. Conventional articulated robots have serially connecting links from the base to the gripper. So, they have very weak structure for he machining work. Stewart Platform is a typical parallel robotic mechanism with a very high stiffness but it has a small work space and a large installation space. This research proposes a new machining robot arm with a double parallel mechanism. It is composed of two platforms and a central axis. The central axis will connect the motions between the first and the second platforms. Therefore, the robot has a large range of work space as well as a high stiffness. This paper will introduce the machining work using the robot and design the proposed robot arm.

Analyzing and Designing a Current Controller for Circulating Current Reduction in Parallel Three-Phase Voltage-Source Inverters

  • Kim, Kiryong;Shin, Dongsul;Kim, Hee-Je;Lee, Jong-Pil
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.502-510
    • /
    • 2018
  • A circulating current is a major problem caused by directly connecting voltage-source inverters (VSIs) in parallel. This circulating current occurs as a zero-sequence current between the inverters by specific switch states. Several studies have presented alternatives using hardware and software methods. When coupled inductors (CIs) are employed for the high-frequency circulating current, a controller is required to prevent the low-frequency circulating current from saturating the CIs. In this study, the zero-sequence circulating current and its alternatives are investigated using hardware and mathematical description. A high-performance circulating current controller is proposed by applying a repetitive controller to the zero-sequence current control loop. The proposed controller can effectively minimize the low-frequency circulating current without any data sharing between the inverters in unfavorable conditions. It can also be applicable to the modular configuration of parallel three-phase VSIs. Experimental results verify the performance of the proposed controller.