• Title/Summary/Keyword: Parallel connecting

Search Result 154, Processing Time 0.022 seconds

Parallel Multiple Electric Power Conversion System Constructed by Connecting Three Power Converters

  • Nakai, Mitsuki;Inaba, Hiromi;Kishine, Keiji;Ishikura, Keisuke
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.3
    • /
    • pp.276-281
    • /
    • 2014
  • The electric power conversion system constructed by connecting two or more power converters in parallel is an advantageous method for making to large capacity and standardization. In this paper, the control method of cross current when three power converters are operated is examined, and it reexamined a preferable system construction method.

Numerical Investigation of the Flow Pulsation in the Gap connecting with Two Parallel Rectangular Channels with Different Cross-section Areas (크기가 다른 단면을 가진 평행한 사각 유로를 연결하는 협소유로의 맥동유동에 관한 수치해석)

  • Seo, Jeong-Sik;Shin, Jong-Kuen;Choi, Young-Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.7
    • /
    • pp.512-519
    • /
    • 2009
  • Flow pulsation in the gap connecting with two parallel channels is investigated by RANS and URANS approaches. The two parallel channels are connected by a small channel called for a gap. The parallel channels are designed to have different cross section area with its ratio of 0.5. Computations are conducted using a CFX 11.0 code. The bulk Reynolds number is 60,000. Predicted results are compared with the previous experimental data. Mean velocity profile at the center of gap region are compared with experiments for its validation. Spectral analysis on the lateral velocity in the center of the gap was performed. Auto correlation for the axial-flow velocity pattern was presented. The unsteady structure of the flow pulsation was visualized in the region of the gap in the parallel channel.

Numerical Investigation of the Flow Pulsation in the Gap connecting with Two Parallel Channels with Different Cross-section Areas (크기가 다른 단면을 가진 평행한 두 채널을 연결하는 협소유로의 맥동유동에 관한 수치해석)

  • Seo, Jeong-Sik;Hong, Seong-Ho;Shin, Jong-Kuen;Choi, Young-Don
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2810-2815
    • /
    • 2008
  • Flow pulsation in the gap connecting with two parallel channels is investigated by RANS and URANS approaches. The two parallel channels are connected by a small channel called for a gap. The parallel channels are designed to have different cross section area with its ratio of 0.5. Computations are conducted using a CFX 11.0 code. The bulk Reynolds number is 60,000. Predicted results are compared with the previous experimental result. Mean velocity profile at the center of gap region are compared with experiments for its validation. Spectral analysis on the lateral velocity in the center of the gap is presented. Auto and cross correlation for the axial-flow velocity pattern are presented. The unsteady structure of the flow pulsation was visualized in the region of the gap in the parallel channel.

  • PDF

Development of Two Types of Novel Planar Translational Parallel Manipulators by Using Parallelogram Mechanism (평행사변형 기구를 이용한 평면 병렬형 병진운동 기구 개발)

  • Kim, Han-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.8 s.197
    • /
    • pp.50-57
    • /
    • 2007
  • In this paper, two types of novel planar Translational Parallel Manipulators (TPMs) by using parallelogram mechanism are conceived. One is made up of two Pa-P (Parallelogram-Prismatic) legs connecting the base to the moving platform. The other consists of two P-Pa legs, which is the kinematic inversion of the former. Since connecting links in a parallelogram mechanism are subject to only tensile/compressive load and all the heavy actuators are mounted at the base, the proposed manipulators can be applied for planar positioning/assembly tasks requiring high stiffness and high speed. The position, velocity, and statics are analyzed, and the design methodology using prescribed workspace and velocity transmission capability is presented. Finally, two types of prototype manipulators have been developed.

A Study on the Converter Drive by Means of Series and Parallel Connection (콘버어터 직병렬 접속 운전에 관한 연구)

  • Chung, Yon-Tack;Seo, Yong-Soo;Hwang, Lak-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.9
    • /
    • pp.347-354
    • /
    • 1984
  • This paper presents a method of improving the power factor and , the waveform of A.C line currents and the output waveforms of AC to DC fully bridge converter systems which is achieved by connecting CON I.II and CON III.IV in series and parallel. The basic principle of the CON I.II.III.IV's operation is simple and feasibility of thease converter is proved by experiments. CON I and CON III are constructed of natural commutation, CON II and CON IV are constructed of forced commutation. The experimental results show that the power factor and waveform of the source currents and the output waveforms are improved by the method of connecting converter in series and parallel and driving it in I, II, III, IV quadrant.

  • PDF

Improvement of Available Battery Capacity in Electric Vehicles

  • Liu, Yow-Chyi
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.497-506
    • /
    • 2013
  • This paper proposes a new method to improve the available battery capacity in electric vehicles by connecting lead-acid batteries with lithium-ion battery in parallel to supply power. In addition, this method combines the discharge characteristics of batteries to improve their efficiency and lower their cost for electric vehicles. A lithium-ion battery set is used to connect with N sets of lead-acid batteries in parallel. The lead-acid battery supplies the initial power. When the lead-acid battery is discharged by the load current until its output voltage drops to the cut-off voltage, the power management unit controls the lead-acid battery and changes it to discharge continuously with a small current. This discharge can be achieved by connecting the lead-acid battery to a lithium-ion battery in parallel to supply the load power or to discharge its current to another lead-acid or lithium-ion battery. Experimental results demonstrates that the available capacity can be improved by up to 30% of the rated capacity of the lead-acid batteries.

Output Characteristics of Parallel or Serially Connected Helical Magneto-Cumulative Generators (병렬 또는 직렬로 결합한 나선형 자장압축발전기의 출력특성 분석)

  • Kuk Jeong-Hyeon;Lee Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.11
    • /
    • pp.647-657
    • /
    • 2004
  • Helical magneto-cumulative generator(HMCG)s are very useful devices in suppling pulsed high current to inductance loads. To apply fast high voltage pulses to high impedance loads, high current outputs of HMCGs are required to be conditioned to higher voltages by using various pulse components such as opening/closing switches and pulse transformer. In this paper, stepping with the trends of requirements for ever-increasing energy in pulsed power applications coupling methods is investigated to obtain higher output energy by connecting several HMCGs in series or parallel way. The coil dimension of HMCGs used in series or parallel connections was 50 mm in diameter and 150 mm in length. The coil was fabricated by using enamel-coated copper wire of 1 mm in diameter. The highest energy amplification ratio and peak voltage of load were achieved from the serially connected four-barrel HMCG system. They were 68 and 34 kV, respectively, when the initial energy of 0.36 kJ was supplied into that system with the load of 0.4 μH. Within the tested range of inductance ratio, energy amplification ratio was found to be highly dependent on the inductance ratio of serial- and parallel-connected HMCG systems to load, which to be optimal around 500 was turned out. The experimental results showed that the output energy and voltage of load are controlled by connecting HMCGs in series or parallel.

A Numerical Study on the Reinforcement Method of a Pillar Using Tension Bolts at the Connecting Part between 2-Arch Tunnels and Parallel Tunnels (2-Arch 터널과 병렬 터널 접속부에서의 텐션볼트를 사용한 필라 보강 방법에 대한 수치해석)

  • Park, Yeon-Jun;Choi, Jae-Jin
    • Tunnel and Underground Space
    • /
    • v.25 no.5
    • /
    • pp.470-486
    • /
    • 2015
  • Two-arch tunnels require minimal spacing between the 2 tunnels and thus occupy small amount of land compared to parallel tunnels. But it is rather expensive. The parallel tunnel is not as expensive, but it requires more land than 2-arch tunnels. This may cause a problem when there is a land shortage. The new design is to connect these two types of tunnels by another pair of parallel tunnels where the separation distance is gradually increasing. The applicability of this new design to the cases where rock condition is not even fair has to be verified since the width of the pillar between the connecting tunnels can be quite narrow. Therefore both two and three dimensional numerical analyses were conducted and pillar stability was examined for rock classes IV and V in two different ways. Results showed that this new design is still effective for poor rock conditions if central pillar is properly reinforced by tension bolts as long as overburden is less than five times of the tunnel diameter.

Hardware Simulator Development for a 3-Parallel Grid-Connected PMSG Wind Power System

  • Park, Ki-Woo;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.555-562
    • /
    • 2010
  • This paper presents the development of a hardware simulator for a 3-parallel grid-connected PMSG wind power system. With the development of permanent magnetic materials in recent years, the capacity of a PMSG based wind turbine system, which requires a full-scale power converter, has been raised up to a few MW. Since it is limited by the available semiconductor technology, such large amounts of power cannot be delivered with only one power converter. Hence, a parallel connecting technique for converters is required to reduce the ratings of the converters. In this paper, a hardware simulator with 3-parallel converters is described and its control issues are presented as well. Some experimental results are given to illustrate the performance of the simulator system.

Applications of Parallel Coordinate Plots for Visualizing Gene Expression Data (평행좌표 플롯을 활용한 유전자발현 자료의 시각화)

  • Park, Mi-Ra;Kwak, Il-Youp;Huh, Myung-Hoe
    • The Korean Journal of Applied Statistics
    • /
    • v.21 no.6
    • /
    • pp.911-921
    • /
    • 2008
  • Visualization of the gene expression data on a low-dimensional graph is helpful in uncovering biological information contained in the data. In this study, we focus on two modified versions of the parallel coordinate plot. First one is the ePCP(enhanced parallel coordinate plot) which shows "near smooth" connecting curves between axes spaced proportionately to the proximity of re-ordered variables. Second one is APCP(Andrews' type parallel coordinate plot) which is obtained by rotating Andrews' plot that has a form of the parallel coordinate plot. Visualization procdures using ePCP and APCP are given for the lymphoma data case.