• 제목/요약/키워드: Parallel Transfer

검색결과 546건 처리시간 0.028초

PF 열교환기의 열전달과 압력강하 특성 실험 연구 (Experimental of Study on Heat Transfer and Pressure drop of PF Heat Exchangers)

  • 엄유식;서동남;박경만;이상재;김대훈;권영철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.519-524
    • /
    • 2008
  • In the present study, the air-side heat transfer and pressure drop characteristics of the fin-tube and PF heat exchangers have been experimentally investigated under the cooling standard condition. Fin type of PF heat exchanger is a triangler and squarer form. The experimental data of the slit fin-tube and two kinds of PF heat exchangers are measured using the air-enthalpy calorimeter and the constant temperature water bath. As the inlet air velocity increases, the heat transfer rate and pressure drop of the heat exchanger increased. The heat transfer rate and pressure drop of PF-2 heat exchanger of the squarer fin is larger than that of PF-1 heat exchanger of the triangler fin. As the inlet air temperature increases, the heat transfer rate decreases and the pressure drop is nearly uniform.

  • PDF

기존 시스템 환경에서의 병렬 미디어 서버의 설계 및 구현 (Design and Implementation of parallel Media server in current system environment)

  • 김경훈;류재상;김서균;남지승
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(3)
    • /
    • pp.97-100
    • /
    • 2000
  • As network resources have become faster and demands for multimedia service through network have increased, the demand for Media server system has increased. These kinds of media server solve their bottle neck problem of internal storage device by using parallel system which takes advantage of fast network resource. Many vendors have suggested each of their media server system to solve these problem radically, but most of them require major modification of infra component and additional drawback has added. For example, storage mechanism for specific media requires new file system which is totally different from traditional one, and algorithm for enhancing performance may not suit for traditional operating system environment. In this paper, we designed a parallel media server based on web interface of traditional system and implemented a program for media server. Implemented server system performs parallel processing through web interface without any modification of traditional system, and controls which is related to merging load by distributed data is charged only to client and control server and consequently load of storage server can be minimized. And also, data transfer protocol for streaming media includes Retransfer algorithm and client Admission control policy relevant to performance of whole system.

  • PDF

CPU-GPU 메모리 계층을 고려한 고처리율 병렬 KMP 알고리즘 (High Throughput Parallel KMP Algorithm Considering CPU-GPU Memory Hierarchy)

  • 박소은;김대희;이명호;박능수
    • 전기학회논문지
    • /
    • 제67권5호
    • /
    • pp.656-662
    • /
    • 2018
  • Pattern matching algorithm is widely used in many application fields such as bio-informatics, intrusion detection, etc. Among many string matching algorithms, KMP (Knuth-Morris-Pratt) algorithm is commonly used because of its fast execution time when using large texts. However, the processing speed of KMP algorithm is also limited when the text size increases significantly. In this paper, we propose a high throughput parallel KMP algorithm considering CPU-GPU memory hierarchy based on OpenCL in GPGPU (General Purpose computing on Graphic Processing Unit). We focus on the optimization for the allocation of work-times and work-groups, the local memory copy of the pattern data and the failure table, and the overlapping of the data transfer with the string matching operations. The experimental results show that the execution time of the optimized parallel KMP algorithm is about 3.6 times faster than that of the non-optimized parallel KMP algorithm.

Analysis of Facilitied Transport through Fixed Site Carrier Membranes

  • Kang, Yong-Soo;Hong, Jae-Min;Kim, Un-Young
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1995년도 제3회 심포지움 (분리막 연구의 최신동향)
    • /
    • pp.57-71
    • /
    • 1995
  • A simple mathematical model for gacilitated mass transport with a fixed site carrier membrane was derived by assuming an instantaneous, microscopic concentration (activity) fluctuation, The concentration fluctuation, developed due to reversible chemical reaction between carrier and solute, could acuse the higher chemical potential gradient and the facilitated transport. For mathematical formulation, an analogy was employed between the mass transfer for the facilitated transport with fixed site carrier membrane and the electron transfer in a parallel resistor-capacitor (RC) circuit. For the single RC model, it was assumed that a single capacitor represented the total carrier and a solute could not inter-diffuse between matrix and carrier, allowing only two diffusional pathways, This assumption was relaxed by adopting a serial combination of the parallel RC circuit. Here, a solute diffuses in two elements (matrix or carrier) can exchange its pathway, exhibiting four diffusional pathways. The current models were examined against experimental data and the agreement was exceptional.

  • PDF

An Interference Isolation Method for Wireless Power and Signal Parallel Transmissions on CPT Systems

  • Zhou, Wei;Su, Yu-Gang;Xie, Shi-Yun;Chen, Long;Dai, Xin;Zhao, Yu-Ming
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.305-313
    • /
    • 2017
  • A novel interference isolation method is proposed by using several designed coils in capacitive power transfer systems as isolation impedances. For each designed coil, its stray parameters such as the inter-turn capacitance, coil resistance and capacitance between the coil and the core, etc. are taken into account. An equivalent circuit model of the designed coil is established. According to this equivalent circuit, the impedance characteristic of the coil is calculated. In addition, the maximum impedance point and the corresponding excitation frequency of the coil are obtained. Based on this analysis, six designed coils are adopted to isolate the interference from power delivery. The proposed method is verified through experiments with a power carrier frequency of 1MHz and a data carrier frequency of 8.7MHz. The power and data are transferred parrallelly with a data carrier attenuation lower than -5dB and a power attenuation on the sensing resistor higher than -45dB.

고속라우터에 대한 고찰(I)-STC104의 레이블링 알고리즘 (Study on High Speed Routers(I)-Labeling Algorithms for STC104)

  • 이효종
    • 정보처리학회논문지A
    • /
    • 제8A권2호
    • /
    • pp.147-156
    • /
    • 2001
  • A high performance routing switch is an essential device to either the high performance parallel processing or communication networks that handle multimedia transfer systems such as VOD. The high performance routing chip called STC104 is a typical example in the technical aspect which has 32 bidirectional links of 100Mbps transfer sped. It has exploited new technologies, such as wormhole routing, interval labeling, and adaptive routing method. The high speed router has been applied into some parallel processing system as a single chip. However, its performance over the various interconnection networks with multiple routing chips has not been studied. In this paper, the strucrtures and characteristics of the STC104 have been investigated in order to evaluate the high speed router. Various topology of the STC104, such as meshes, torus, and N-cube are defined and constructed. Algorithms of packet transmission have been proposed based on the interval labeling and the group adaptive routing method implemented in the interconnected network. Multicast algorithms, which are often requited to the processor networks and broadcasting systems, modified from U-mesh and U-torus algorithms have also been proposed overcoming the problems of point-to-point communication.

  • PDF

수직 평행평판에서의 혼합대류 열전달 (Combined Convective Heat Transfer from Vertical Parallel Plates)

  • 양성환;권순석
    • 대한기계학회논문집
    • /
    • 제13권2호
    • /
    • pp.299-306
    • /
    • 1989
  • 본 연구에서는 밀집형 열교환기에 사용되고 있는 루우버 핀에 해당되는 간단한 형상인 등온, 수직, 평행평판에서의 혼합대류 열전달에 관하여 Pr=0.7, Gr=$10^{4}$ 및 50<Re$_{L}$<500인 경유 평판간격과 평판길이를 변수로 하여 유한차분법으로 수치해석하였다. 속도분포, 온도분포 및 Nusselt수를 구하여 평판의 간격과 길이가 열전달에 미치는 영향에 관하여 연구하였다.

엔진발전기와 연계된 BESS의 무순단 모드 전환 기법 (Seamless Transfer Method of BESS Connected by Engine Generator)

  • 신은석;김현준;김교민;유승영;한병문
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1709-1717
    • /
    • 2015
  • In remote islands PV (Photo Voltaic) panel with BESS (Battery Energy Storage System) supplies electric power to the customers in parallel operation with EG (Engine Generator) to save fuel consumption and to mitigate environmental load. BESS operates in voltage control mode when it supplies power to the load alone, while it operates in current control mode when it supplies power to the load in parallel with EG. This paper proposes a smooth mode change scheme from current control to voltage control of BESS by adding proper initial value to the integral part of voltage control, and a smooth mode change scheme from voltage control to current control by tracking the EG output voltage to the BESS output voltage using PLL (Phase-Locked Loop). The feasibility of proposed schemes was verified through computer simulations with PSCAD/EMTDC, and the feasibility of actual hardware system was verified by experiments with scaled prototype. It was confirmed that the proposed schemes offer a seamless operation in the stand-alone power system in remote islands.

복합각도 요철을 가지는 사각 덕트 내의 열전달 및 압력강하 특성 (Characteristics of Heat/Mass Transfer and Pressure Drop in a Square Duct with Compound-Angled Rib Turbulaters)

  • 최청;이동호;조형희
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.325-333
    • /
    • 2001
  • The present study investigates convective heat/mass transfer and flow characteristics inside the cooling passage of the gas-turbine blades. It is important to increase not only the heat transfer rates but also the uniformity of heat transfer in the cooling passage. The square duct has compound-angled ribs with $60^{\circ},\;70^{\circ}$ and $90^{\circ}$ attack angles, which are installed on the test plate surfaces. a naphthalene sublimation technique is employed to determine the detailed local heat transfer coefficients using the heat and mass transfer analogy. The ribs disturb the main flow resulting in the recirculation and secondary flows near the ribbed wall and the vertices near the side-wall. The local heat transfer and the secondary flow in the duct are changed largely according to the rib orientation. Therefore, geometry and arrangement of the ribs are important fur the advantageous cooling performance. The angled ribs increase the heat transfer discrepancy between the wall and center regions because of the interaction of the secondary flows. The average heat/mass transfer coefficient and pressure drop of the ribs with the $60^{\circ}$ $-90^{\circ}$ compound-angle are higher than those with the $60^{\circ}$ attack angle. Also, the thermal efficiency of the compound-angled rib is higher than that with the $60^{\circ}$ attack angle. The uniformity of heat/mass transfer coefficient on the cross ribs may is higher than that on the parallel ribs array.

  • PDF